Physiological Information Reliability: Cross-Layer Adaptive Resource Allocation for Cardiovascular Sensing

Navaneeth Krishnan Kamalakannan, Janakiraman Kamalakannan, Harinisri Velmurugan

Abstract

Cardiovascular sensing systems must preserve clinically useful information despite signal degradation, wireless packet loss, energy constraints, and edge-computation latency, yet signal quality, delivery reliability, energy, and latency are conventionally optimized as separate, layer-local objectives. We formalize Physiological Information Reliability (PIR), a joint state representation Xt=[Sm,Sw,Se,Sc]X_t = [S_m, S_w, S_e, S_c] that couples a multimodal ECG/PPG physiological information value (PIV) with wireless-channel, energy, and compute-placement state, and instantiate its controller as a LinUCB contextual bandit that adapts network-coding redundancy and edge/local compute placement online. In a controlled, multiseed (n=5n=5) evaluation of 1,200 sequential monitoring windows per seed under a Gilbert–Elliott burst-erasure channel, PIR-LinUCB reaches the lowest steady-state energy draw (0.089±0.0040.089 \pm 0.004 J/window) and the highest mean reward (0.205±0.0650.205 \pm 0.065) among five compared policies, while every policy meets a 150 ms latency deadline; a hand-tuned heuristic baseline is statistically indistinguishable from it on reward. We report the accuracy–energy-latency trade-off honestly, including where the bandit's advantage is condition-dependent rather than universal, and discuss the limits of a synthetic-data, simulated-channel evaluation. Code and configurations are provided for reproducibility.

Keywords: physiological monitoring, contextual bandits, network coding, edge computing, wireless health sensing

Data and Code Availability This study uses no real patient data. All physiological signals are

produced by a documented, parameterized synthetic ECG/PPG generator (Section 4) that reproduces the graded and complete-modality degradation protocol used in prior multimodal fusion work (Kamalakannan and Kamalakannan, 2026); no public corpus offers independently controllable, graded degradation of both modalities simultaneously. Code, configuration files, and the full multiseed experiment logs/figures underlying every number reported here are included as anonymized supplementary material for review, and will be released at a de-anonymized public repository upon acceptance.

Institutional Review Board (IRB) This work involves no human subjects and no real patient data; all evaluation is performed on synthetic waveforms generated in software. No IRB review was required.

1. Introduction

Wearable cardiovascular sensing pipelines chain together sensing, wireless transmission, edge or on-device inference, and clinical decision support. Reliability in such pipelines is conventionally treated as an end-to-end packet-delivery question: did the bits arrive? But not every window of ECG/PPG data carries equal clinical value: a packet spanning a clean, diagnostically usable beat and a packet spanning motion-artifact noise are not equally worth protecting, yet systems that allocate redundancy, compute, or energy by fixed or purely channel-aware rules treat them identically.

Existing work instead optimizes signal quality (Orphanidou et al., 2015; Kamalakannan and Kamalakannan, 2026), transmission reliability (Ho et al., 2006; Kamalakannan and Velmurugan, 2026), or task/semantic relevance of transmitted content (Gündüz et al., 2023) largely in isolation from one another and from the energy and compute budget that a body-worn device actually has. We argue that communication reliability is not the same objective as physiological information reliability, and that a

  • N. Krishnan K. is with the Department of Electronics and Communication Engineering, Saveetha School of Engineering (e-mail: knavaneeth385@gmail.com) and J. K is with the Government Kilpauk Medical College and Hospital (e-mail: kjanaki2408@gmail.com) and Harinisri V. is with the Department of Physics and Nanotechnology, SRM Institute of Science and Technology, Chennai, India (e-mail: harinisriv2003@gmail.com).

cross-layer controller should allocate scarce wireless, energy, and compute resources in proportion to the physiological information at stake, not only to channel conditions.

We formalize this as PIR: a joint state Xt=[Sm(t),Sw(t),Se(t),Sc(t)]X_t = [S_m(t), S_w(t), S_e(t), S_c(t)] spanning medical (signal-quality/fusion), wireless, energy, and compute sub-states (Figure 1), and instantiate its control policy as a contextual bandit that learns, online, which coding redundancy and compute placement to use per monitoring window. PIR bridges two previously separate systems – a multimodal ECG/PPG fusion and signal-quality front end (Kamalakannan and Kamalakannan, 2026) and an adaptive random-linear-network-coding transport layer (Kamalakannan and Velmurugan, 2026) – into one closed-loop, learned controller rather than a hand-tuned heuristic.

Contributions. (1) A formal PIR state representation connecting a physiological information value (PIV) with wireless, energy, and compute conditions (Section 3). (2) A LinUCB contextual-bandit controller that selects network-coding redundancy and edge/local compute placement to maximize a PIV-weighted decode utility net of energy, latency, and power penalties. (3) A controlled, multiseed empirical comparison against four non-learned baselines that reports where the learned controller helps, where it does not, and what a synthetic-data proxy evaluation can and cannot show (Sections 5–7).