Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning

Yizhao Qian, Jiayuan Luo, Wanyi Zhu, Yameng Zhang, Max Q. -H. Meng, Yixuan Yuan, Li Liu

Yizhao Qian, Jiayuan Luo, Wanyi Zhu, Yameng Zhang, Max Q.-H. Meng Fellow, IEEE, Yixuan Yuan* Senior Member, IEEE, and Li Liu* Member, IEEE

Abstract—Robotic ultrasound policies operating directly on B-mode images require extensive interaction data, whereas real-robot data acquisition is costly and safety-constrained. Simulation offers a scalable alternative, but zero-shot transfer of raw-B-mode closed-loop policies depends not only on frame realism but also on whether simulated observations reproduce task-relevant changes induced by probe motion. A mismatch in this pose-observation relationship can invalidate the feedback behavior learned in simulation. We term the cross-domain consistency of such motion-induced feature changes task-relevant feature-dynamics fidelity (TR-FDF) and study it as a property of the observation model. A local contraction analysis shows that greater local sensitivity of TR-FDF mismatch to probe motion reduces the local contraction margin, irrespective of the specific observation modality. This analysis motivates a TR-FDF-oriented robotic ultrasound simulator. The simulator updates the probe pose according to policy actions and generates the corresponding structural masks. A structural intermediate domain shared by anatomical masks and ultrasound images constrains pose-driven feature evolution and reduces this sensitivity. Trajectory-level fixed noise suppresses pose-independent sampling jitter, while a low-step conditional flow model provides realistic B-mode observations in real time. In phantom experiments on a robotic ultrasound platform, a policy trained exclusively in simulation succeeded in 390 of 400 zero-shot deployments across four target planes. The simulator maintained competitive single-frame image quality and generated observations at 67.1 Hz. Controlled interventions revealed a clear divergence between simulator-side and real-robot success as this sensitivity increased. Ablation studies and comparisons with external baselines further showed that the proposed design better preserves feature dynamics, image quality, and rollout efficiency than alternative generation strategies. These results indicate that, in the local closed-loop setting studied here, TR-FDF captures a transfer property not measured by single-frame realism.

Index Terms—Robotic ultrasound, sim-to-real transfer, B-

mode imaging, feature dynamics, conditional flow matching, reinforcement learning, medical robotics.

I. INTRODUCTION

In recent years, robotic ultrasound systems have evolved from relying on manual operation and fixed scanning protocols toward machine-learning-driven platforms for perception and closed-loop control. Previous studies have achieved target-plane acquisition [1], anatomical-structure tracking [2], and scan navigation [3], [4]. In these tasks, control policies can estimate the current probe state from continuous B-mode ultrasound images and output motion commands for the robotic arm [2], [4]–[6]. However, learning observation-action relationships from high-dimensional images typically requires a large number of interaction episodes [7], [8]. Reinforcement learning on patients or real robots is constrained by safety and practical feasibility, while expert demonstrations and high-quality annotations are difficult to collect at scale [5]–[9]. Therefore, training image-based control policies in simulation and subsequently deploying them on real robots provides an important means of reducing the need for real-world interaction and annotation.

This study considers zero-shot sim-to-real transfer in the strict sense: the policy is trained exclusively on ultrasound observations generated in simulation, and deployment on the real robot uses no real-robot interaction, online adaptation, or policy fine-tuning. Reliable real-robot closed-loop deployment under this setting remains unestablished. Accordingly, this paper asks: what properties must an ultrasound observation generator possess to enable a raw-B-mode policy trained in simulation to maintain reliable closed-loop behavior on a real robot?

In existing studies of autonomous robotic ultrasound servoing, dependence on real-domain information mainly takes two forms. One line of work introduces vessel segmentation, anatomical masks, or other structured intermediate representations at the perception front end, allowing the policy to learn control through relatively regular interfaces. These methods can achieve good autonomous scanning performance [8], [10]–[12]; however, their policy inputs are no longer raw B-mode images, and the perception process that maps raw images to structured interfaces also typically relies on real ultrasound data for training, calibration, or validation. Therefore, these methods fall outside the scope of this study. Another line

This work was supported by the National Natural Science Foundation of China (Grant 62473192), the Guangdong Regional Cooperation Fund (Grants 2025A1515140001 and 2024A151540132), and the Hong Kong Research Grants Council General Research Fund (Grant 14220622). Corresponding authors: Li Liu (e-mail: liuli@gbu.edu.cn) and Yixuan Yuan (e-mail: yxyuan@ee.cuhk.edu.hk).

Yizhao Qian and Yixuan Yuan is with the Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.

Jiayuan Luo, Wanyi Zhu, and Li Liu are with the School of Advanced Engineering, Great Bay University, and the Dongguan Great Bay Institute for Advanced Study, Dongguan, China.

Yameng Zhang is with the Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China.

Max Q.-H. Meng is with the Shenzhen Key Laboratory of Robotics Perception and Intelligence and the Department of Electronic Engineering, Southern University of Science and Technology, Shenzhen, China. He is also Professor Emeritus in the Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.

of work retains raw B-mode images as the policy input and typically combines simulation frameworks with image-to-image generation to construct the observations required for policy training [9], [13], [14]. Because paired samples acquired from the same anatomy, at the same probe pose, and under the same imaging conditions are difficult to obtain for real and simulated ultrasound [13], [15], [16], these generators commonly use unpaired image translation, with single-frame appearance similarity, content preservation, or domain-distribution alignment as their primary optimization objectives [17], [18]. This approach can improve the realism of generated images and therefore comes closer to directly enabling raw-B-mode zero-shot transfer. However, visual similarity between single frames from the two domains does not guarantee that task-relevant features, such as vessels and anatomical boundaries, undergo consistent changes under the same probe motion [19], [20]. Existing systems therefore often still require real-robot fine-tuning after simulation training [21]. This raises an unresolved question: beyond single-frame realism, what constraints must simulated ultrasound observations satisfy to support stable policy transfer to a real robot?

To answer this question, a simulator must reproduce not only realistic B-mode frames but also task-relevant feature changes induced by probe motion. Because each policy input follows a preceding probe motion [2], [5], discrepancies in the resulting changes between simulation and real ultrasound can lead to an incorrect observation-action relationship. Owing to stochastic ultrasound variations such as speckle, this requirement concerns statistical feature evolution rather than pixel-wise agreement. We refer to this observation-model property as task-relevant feature-dynamics fidelity (TR-FDF). Local closed-loop analysis (see Fig. 1) shows that greater local sensitivity of TR-FDF mismatch to probe motion reduces the effective contraction margin, whereas static target bias and motion-independent perturbations mainly enlarge the ultimate error neighborhood. This distinction is independent of the observation modality. Thus, FID and simulator-side training success alone cannot guarantee stable zero-shot transfer [22].

Building on this analysis, we develop an ultrasound observation generator that jointly targets task-relevant feature evolution, single-frame realism, and rollout efficiency. Given a policy-generated probe pose, a structural renderer first produces multichannel anatomical masks. Stage I maps the masks and ultrasound images into a shared structural intermediate domain, using structural, cross-domain, and local-geometric constraints to preserve pose-driven anatomical changes while suppressing modality-specific factors. Stage II conditionally renders this representation into realistic ultrasound observations, with a frozen ultrasound encoder constraining their structural expression. Fixing the initial noise X0X_{0} along each trajectory suppresses pose-independent frame jitter, while Stage III uses flow reflow and few-step inference to enable real-time rollouts. Together, these components address observation-dynamics mismatch, single-frame realism, and rollout efficiency. To the best of our knowledge, this is the first demonstration of reliable zero-shot sim-to-real transfer for a policy trained exclusively on simulated raw B-mode observations under this strict setting. The contributions of this paper are as follows:

  • We propose task-relevant feature-dynamics fidelity (TR-FDF) to describe the consistency between simulated and real-world feature responses to the same probe motion. Local closed-loop analysis shows that the local sensitivity of TR-FDF mismatch to probe motion reduces the effective contraction margin, whereas static bias and motion-independent perturbations mainly enlarge the ultimate error neighborhood. This conclusion also applies to other observation modalities.

  • We propose a robotic ultrasound simulator for raw-B-mode policy training. Its ultrasound observation generator combines a shared structural intermediate domain, trajectory-level fixed- X0X_{0} conditional rendering, and few-step flow generation to jointly preserve pose-driven feature evolution, single-frame image realism, and rollout efficiency.

  • On a real robotic ultrasound phantom platform, we verify that a raw-B-mode policy trained purely in simulation can be deployed directly on a real robot in a zero-shot manner. Controlled TR-FDF interventions, component ablations, and comparisons with external baselines further show that neither single-frame realism nor simulator-side policy success is sufficient to predict real closed-loop transfer. Under the setting studied in this paper, TR-FDF is an important property closely related to the transferability of the observation model.