arXiv:2611.05936cs.RONov 2026

Manuscript Offprint

arXiv:2611.05936

LumiTac: Compact, High-Rate Six-Axis Optical Tactile Sensing for Human-Robot Interaction

Hao Wu, Haotian Guo, Yu Feng, Yutong Wang, Jianshu Zhou

Hao Wu, Student Member, IEEE, Haotian Guo, Student Member, IEEE, Yu Feng, IEEE/ASME Member, Yutong Wang, and Jianshu Zhou, IEEE/ASME Member

Abstract—Integrating six-axis tactile feedback into robotic interfaces requires compact sensors with accurate load measurement and rapid online reconstruction. This paper presents LumiTac, a low-profile, camera-free optoelectronic tactile sensor combining spatially distributed illumination with spectral encoding. Five photoemitters and five RGBW photoreceivers are mounted on opposing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical channels. Independent testing yielded coefficients of determination (R2R^2) of 0.9657–0.9941, with mean absolute errors of 0.054–0.190 N for forces and 0.304–1.419 mN·m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small forces, and transient response, respectively. Robotic demonstrations further validated its applicability to tactile-guided manipulation and physical human–robot interaction. This study paves the way for compact, high-rate optical tactile sensing in robotic manipulation and human–robot interaction.

Index Terms—Tactile sensors, force/torque sensing, optoelectronic sensors, human-robot interaction, admittance control.

I. INTRODUCTION

ROBOTIC manipulation requires continuous adjustment to contact forces during grasping, alignment, and physical interaction. To enable responsive and adaptive manipulation, embedded sensing [1] and intuitive control interfaces [2], [3] have been explored to enhance robotic perception and interaction. In particular, tactile sensing provides local contact feedback that external vision alone cannot readily supply [4], [5]. Beyond normal and tangential forces, bending and torsional moments characterize rotational loading relevant to contact alignment and orientation control. Measuring the complete six-axis contact wrench therefore supports multidimensional interaction feedback. Integrating this capability into space-constrained robotic interfaces, such as fingertips [6], grippers [7], and wearable devices [8], requires sensing structures with a small footprint, limited thickness, and low mass. Rapid

Figure

Fig. 1. LumiTac prototype and potential applications. (a) Size comparison with a coin; (b) side view of the sensor structure; (c) application concepts for robotic grippers and dexterous hands.

load reconstruction is equally important for timely feedback in contact-rich tasks.

Multi-axis force/torque (F/T) measurement has been implemented using various transduction mechanisms, including capacitive [11], [13], magnetic [14], thermal [6], piezoelectric [15], and optical [9], [16] sensing. Capacitive designs organize deformation-dependent responses through electrode geometry and spacing [13]. Lee et al. improved directional sensitivity through isotropic optimization and redundant measurements [17]. CoinFT achieves a thin, low-cost structure using silicone pillars and configurable electrode readout [11], while HexaTouch reconstructs six-axis loads and contact position from capacitive images [12]. These studies demonstrate the potential of capacitive sensing for compact six-axis measurement. However, parasitic capacitance and electrode misalignment can introduce measurement errors, while cross-axis coupling complicates calibration and the reconstruction of individual force and moment components.

Magnetic tactile sensors infer contact loads from deformation-induced field changes detected by Hall elements [14]. MagCilia combines flexible magnetic cilia with a Hall sensor to reconstruct normal and tangential forces from field changes induced by compression and bending [18]. Veliky et al. use distributed Hall-sensor and magnet pairs to capture translations and rotations of a silicone-supported structure for six-axis load reconstruction [19]. Although magnetic sensing enables

This work was partially supported by the National University of Singapore Start-up Grant (NUS Start-up Grant, FY2026). Hao Wu, Haotian Guo, and Yu Feng contributed equally to this work. (Corresponding author: Jianshu Zhou.) Hao Wu, Haotian Guo, Yu Feng, Yutong Wang, and Jianshu Zhou are with the Department of Mechanical Engineering, National University of Singapore, Singapore (e-mail: jianshuzhou@nus.edu.sg).

WU et al.: LUMITAC FOR SIX-DIMENSIONAL OPTICAL TACTILE SENSING

TABLE I COMPARISON OF REPRESENTATIVE MULTIAxis TACTILE AND FORCE/TORQUE SENSORS.

SensorTransductionSize [mm]Mass (g)Reported load rangesF: N; M: mN·mAccuracyF: N; M: mN·mSampling rateCost(USD)
LiVec finger[7]Optical26.44 × 38.22×12NRF: (±2, ±2, 0–12)M: NRError SDF: (0.112, 0.092, 0.139)M: (1.90, 1.54, 1.26)390 HzNR
El-Azizi et al.[9]Opticalφ27 × 20.8216.4F: ~ (±5, ±5, 0–5)M: ~ (±200, ±200, ±200)MAEF: (0.060, 0.050, 0.070)M: (2.62, 2.68, 0.64)> 2.5 kHz100
F-TOUCH[10]VisuotactileNRNRF: (±1, ±1, 0–8)M: (±20, ±20, ±20)RMSEF: (0.018, 0.016, 0.094)M: (0.657, 1.566, 0.407)30 HzNR
Mao et al.[6]Thermal12 × 15 × 50.30F: (±5, ±5, 0–15)M: (±60, ±60, ±20)RMSEF: (0.180, 0.150, 0.180)M: (0.58, 0.62, 0.26)NRNR
CoinFT[11]Capacitiveφ20 × 22.0F: (±5, ±5, 0–15)M: (±100, ±100, ±80)RMSEF: (0.186, 0.134, 0.186)M: (1.114, 1.322, 0.810)360 Hz< 11
HexaTouch[12]Capacitive15 × 15 × 8NRF: (±5, ±5, 0–25)M: (±100, ±100, ±50)RMSEF: (0.140, 0.130, 0.130)M: (2.48, 2.50, 0.95)NRNR
LumiTac(this work)Opticalφ12 × 4.75< 2F: (±10, ±10, 0–30)M: (±100, ±100, ±20)MAEF: (0.056, 0.054, 0.190)M: (0.774, 1.419, 0.304)~ 300 Hz~ 7

Components are ordered x, y, z. MAE: mean absolute error; RMSE: root-mean-square error; NR: not reported; SD: standard deviation.

compliant multiaxis measurement, external magnetic fields and nearby ferromagnetic objects can distort the measured field, introducing errors that require shielding or compensation.

Thermal and piezoelectric transduction offer further approaches to six-axis sensing. Mao et al. used thin-film thermistors to detect deformation-induced changes in the thermal conductance of a compliant medium, enabling an ultralight design but requiring active heating and temperature compensation [6]. Gong et al. combined an ultrathin piezoceramic shell with patterned electrodes to distinguish load-induced charge distributions. This monolithic architecture supports sensitive dynamic measurements, although its AC-coupled readout limits absolute quasi-static load measurement [15].

Vision-based tactile sensors encode contact-induced deformation in camera images and infer forces from surface appearance or marker displacement, as demonstrated by GelSight, TacTip, and DIGIT Pinki [20]–[22]. Camera-based pose tracking enables six-axis force and moment reconstruction in fiducial-based sensors [23]. Optical feedback has been integrated into compliant grippers for manipulation and force regulation [16], [24], [25]. Despite their high spatial resolution, camera acquisition and image processing can limit update rates. Camera size, optical working distance, and computational demands also complicate integration into thin, compact robotic interfaces.

Camera-free optical sensors recover loads from wavelength shifts or discrete light measurements. Fiber Bragg grating-based designs distribute strain measurements along an optical fiber to achieve low-coupling six-axis sensing, although they require fiber attachment and wavelength interrogation [26]. Discrete optoelectronic designs instead measure deformation-dependent light signals using distributed emitters and receivers [27], [28].

LiVec combines local optical measurements to recover forces, displacements, and resultant moments [7], whereas El-Azizi et al. use LEDs as both emitters and receivers to measure motion between elastomer-connected plates [9]. By avoiding image formation, discrete optical readout supports compact layouts, low-dimensional signal processing, and high-rate acquisition. Ambient light, optical alignment, and elastomer nonlinearity nevertheless remain design and calibration considerations.

A central challenge in compact six-axis optical sensing is to distinguish coupled translations and rotations, since different deformation modes may produce similar changes in received light intensity. Previous studies have explored overlapping light signals and patterned color encoding to introduce spatial and spectral information into deformation measurements [29], [30]. The comparison in Table I further motivates combining informative optical measurements with a low-profile structure and rapid online reconstruction. To address these requirements, we present LumiTac, a camera-free optoelectronic tactile sensor shown in Fig. 1. Five photoemitters and five RGBW photoreceivers are mounted on opposing PCBs coupled through translucent silicone. The spatially offset emitter-receiver layout and multiple LED colors provide spatial and spectral cues associated with load-induced interlayer motion. A compact multilayer perceptron (MLP) jointly processes the resulting 20 optical channels to estimate three force and three moment components, enabling frame-wise online load reconstruction. The main contributions are as follows:

  • A miniaturized hardware design that integrates six-axis tactile sensing into a head measuring 12 mm in diameter and 4.75 mm in thickness, with a mass below 2 g and an estimated component cost of approximately USD 7.

  • An efficient six-axis reconstruction pipeline achieving mean absolute errors (MAEs) of 0.054–0.190 N for forces and 0.304–1.419 mN·m for moments, with coefficients of determination (R2R^2) of 0.9657–0.9941 on an independent test recording. Its online implementation delivers an average prediction update rate of 303.57 Hz with a median software processing latency of 0.722 ms.

  • Experimental validation of load tracking, sensitivity to small forces, and transient response, together with demonstrations of simulated manipulator guidance and physical robot admittance control, establishing a single tactile interface for robot motion and gripper operation.

References (29)