Manuscript Offprint
arXiv:2610.09536MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping Feedback
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. XX, NO. XX, XXXX
1
MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping Feedback
Yu Feng, Hao Wu, Haotian Guo, Haoming Liu, William Su, Jingxiang Guo, Jiankun Li, Masayoshi Tomizuka, Life Fellow, IEEE, Wen Jung Li, Fellow, IEEE, and Jianshu Zhou, Member, IEEE
Abstract—Robotic grasping and surface exploration benefit from simultaneous measurement of normal and tangential forces and from surface information obtained through contact. Here, we present a compact magnetociliary tactile sensor (MagCilia) that combines a flexible magnetic-cilia structure with a Hall sensor for 3D force sensing. Quasi-static finite element analysis is used to investigate structural deformation and magnetic responses under multidirectional loading. To reconstruct forces from the coupled magnetic channels, we propose causal history fusion regression (CHFR), which combines current magnetic-field measurements with their recent changes. Five-fold cross-validation grouped by calibration record yields root-mean-square errors of 0.40, 0.57, and 0.69 N for , , and , respectively, with corresponding coefficients of determination of 0.93, 0.90, and 0.92. Robotic experiments demonstrate tangential-force-guided gripper adjustment and multi-axis load monitoring under external perturbations. Frequency-domain features of the reconstructed forces distinguish six surface categories with 99.39% accuracy in three-fold cross-validation grouped by acquisition session. An online robotic demonstration additionally identifies all six tested surfaces. These results demonstrate 3D force reconstruction, grasping feedback, and surface recognition using a single compact tactile unit.
Index Terms—Tactile sensors; 3D force sensing; magnetic cilia; robotic grasping; surface recognition
This work was supported in part by the National University of Singapore under the NUS Start-up Grant (FY2026). Yu Feng, Hao Wu, and Haotian Guo contributed equally. (Corresponding authors: Wen Jung Li and Jianshu Zhou.)
Yu Feng, Hao Wu, Haotian Guo, Haoming Liu, Jingxiang Guo, and Jianshu Zhou are with the Department of Mechanical Engineering, National University of Singapore, Singapore (e-mail: jianshuzhou@nus.edu.sg).
William Su and Masayoshi Tomizuka are with the Department of Mechanical Engineering, University of California, Berkeley, Berkeley, CA, USA.
Jiankun Li and Wen Jung Li are with the Mechanical Engineering Department, City University of Hong Kong, Kowloon, Hong Kong SAR, and CAS-CityU Joint Laboratory for Robotic Research, City University of Hong Kong Shenzhen Research Institute, Shenzhen, China (e-mail: wenjli@cityu.edu.hk).
(a)

MagCilia
10 mm
(b)
Fig. 1. Photograph and layered structure of MagCilia. (a) Sensor prototype with a scale reference; (b) magnetic-cilia skin, buffer layer, readout circuit board, and housing.
In recent years, tactile sensors capable of measuring 3D contact forces have provided richer tactile information for dexterous robotic manipulation by sensing both the direction and magnitude of contact loads [4]. Various approaches have been developed for multi-axis contact force measurement, including piezoresistive [5], capacitive [6], [7], non-vision-based optical [8], [9], visuotactile [10]–[12], and magnetic tactile sensing [13], [14]. Magnetic tactile sensors measure changes in the local magnetic field caused by deformation of flexible magnetic structures under contact loads. Their multi-axis sensing characteristics are closely related to the coupling among the magnetization configuration, structural deformation, and magnetic-field readout [15], [16].
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. XX, NO. XX, XXXX
The design of flexible magnetic structures is a key aspect of multidimensional sensing in magnetic tactile sensors. Existing studies have explored various configurations, including sinusoidally magnetized films [17], stacked orthogonally magnetized films [18], combinations of magnetic films and flexible pillars [19], and magnetic cilia [20]–[24]. Magnetic cilia convert contact loads into changes in the position and orientation of magnetic material through compression and bending, providing a direct mechanical response for sensing contact states and surface features. For magnetic-cilia sensors, quantitative 3D force reconstruction is complicated by coupling between the mechanical deformation and the three magnetic-field channels. In a tactile structure comprising a magnetic-cilia skin and a flexible supporting layer, external loads induce not only compression and bending of the cilia but also displacement of the base membrane and shear deformation of the supporting layer. These deformations jointly alter the local magnetic field, so a force applied along one axis can affect multiple magnetic channels. This coupling limits the use of a direct, channel-by-channel mapping for 3D force reconstruction [25], [26].
Here, we present MagCilia, a compact single-unit magnetociliary tactile sensor for 3D force sensing (key parameters in Supplementary Table ??). The sensor integrates a magnetic-cilia skin, a PDMS buffer layer, and a Hall sensor. CHFR combines the current three-axis magnetic readout with causal history features to jointly reconstruct the normal force and two tangential force components from the coupled responses. Calibration experiments yield root-mean-square errors of 0.40, 0.57, and 0.69 N for , , and , respectively. Signals are acquired at 246 Hz, and the reconstructed forces are used for robotic grasping feedback and active surface recognition. Robotic experiments demonstrate multi-axis force responses during grasping, stepwise loading, and multidirectional perturbations, with the reconstructed forces used to adjust the gripper opening under external loading. Frequency-domain force features distinguish six surface categories with 99.39% accuracy in three-fold offline evaluation grouped by acquisition session, and scan-level recognition is demonstrated online. These experiments examine force reconstruction and two robotic applications using the same tactile unit.
The study combines the sensing mechanism, force reconstruction, and robotic use of the reconstructed signals. The grasping experiments examine load magnitude and direction at the contact interface, whereas surface scanning uses the temporal structure of those same force signals to distinguish surface categories.
II. MAGCILIA STRUCTURE AND SENSING MECHANISM
A. Sensor Structure and Fabrication
The overall structure of MagCilia is shown in Fig. 1. It consists of a magnetic-cilia skin, a PDMS buffer layer, a Hall sensor, and a housing. The upper magnetic-cilia skin contacts the object, and the underlying PDMS buffer layer supports the skin and deforms with it under load. The Hall sensor on the readout circuit board measures the resulting magnetic-field changes. The housing supports and aligns the assembled layers.

Fig. 2. Contact sensing mechanism of MagCilia. Normal, x/y tangential, and oblique loading induce different deformations of the magnetic cilia and supporting structure.
The magnetic-cilia skin has in-plane dimensions of mm, a base-membrane thickness of 1 mm, and a cilia height of 2.5 mm. The skin is magnetized along its surface normal. The underlying PDMS (Sylgard 184) buffer layer has dimensions of mm. The magnetic-cilia skin and buffer layer are bonded through PDMS curing, and the Hall sensor is aligned in-plane with the center of the magnetic-cilia skin. Material preparation and fabrication conditions are provided in Supplementary Note ??.
B. Magnetic Vector Response
Fig. 2 illustrates the typical deformation of MagCilia under normal, tangential, and oblique loading. Normal loading primarily compresses the magnetic cilia and supporting layer, changing the relative position between the magnetic material and the Hall sensing point. Tangential loading bends the cilia and is accompanied by displacement of the magnetic base membrane and shear deformation of the supporting layer, thereby changing both the position and local orientation of the magnetic material. Oblique loading combines normal and tangential components, producing compression, bending, and shear that jointly affect the magnetic-field output.
The magnetization model assumes a relative permeability of , an initial magnetization normal to the skin, and conservation of magnetic moment per reference volume. The magnetic moment rotates with the material according to the local rotation from the polar decomposition of the deformation gradient. The detailed magnetic dipole field integral is provided in Supplementary Note ??. This formulation accounts for changes in the position and orientation of the magnetic material caused by cilia bending, base-membrane displacement, and buffer-layer deformation. Here, denotes the three-axis magnetic-field vector at the Hall sensing point. For a fixed contact condition and in the vicinity of a quasi-static loading state , a local expansion of the magnetic response gives
(1)
S is the local magnetic-response sensitivity matrix, whose off-diagonal terms describe the influence of loading along one direction on the other magnetic channels. Structural deformation simultaneously changes the position and local orientation of the magnetic material relative to the Hall sensing point, resulting in coupling among the three magnetic-field components, with the corresponding sensitivities also varying with the loading state [25]. This state-dependent coupling motivates a joint mapping from the three magnetic channels to the three force components. The reconstruction model described below additionally incorporates recent magnetic changes to represent temporal dependence. The state-dependent cross-channel sensitivities indicate that directional information is distributed across the three magnetic components, motivating joint rather than channel-wise force reconstruction.
C. Finite Element Analysis
Quasi-static finite element analysis is performed in COM-SOL to investigate structural deformation and magnetic-field responses under normal, orthogonal tangential, and oblique loading. The model dimensions are consistent with the actual magnetic skin and buffer layer. Both layers are modeled as nearly incompressible neo-Hookean materials, with a fixed bottom surface and loading through a rigid top plate. To compare directional shear responses under established contact, a 5 m normal pre-indentation is maintained while tangential displacements of up to 2.5 m are applied along , , 45°, and 135° (details in Supplementary Note ??).
The magnetic-field changes are normalized by the remanence parameter and expressed as . The unloaded state is used as the baseline for normal loading, whereas the pre-indented state is used for tangential loading. Fig. 3 shows the magnetic-field changes under different loading directions. Under normal indentation, the magnetic-field change occurs primarily in the component. Under shear along the positive and negative orthogonal directions, the dominant transverse magnetic-field response reverses sign with the loading direction, whereas oblique shear produces changes in both transverse components. Different loading directions therefore produce distinct, coupled magnetic responses. These simulations motivate calibration using the complete magnetic-field vector, although they do not establish a unique inverse mapping from magnetic field to force.
III. 3D FORCE CALIBRATION AND RECONSTRUCTION
A. Synchronized Data Acquisition and Organization
The calibration setup consists of MagCilia and a reference force sensor (Dayang Sensor Y45), as shown in Fig. 4. To calibrate the coupled magnetic response across different contact states, a handheld indenter applies normal compression,
(a)
Normal load

(b)
x shear
Compression ( m)
(c)
y shear
Signed shear ( m)
Fig. 3. Quasi-static deformation and normalized magnetic response. (a) Normal indentation and corresponding magnetic response; (b) x shear deformation (left) and magnetic response under orthogonal shear (right); (c) y shear deformation (left) and magnetic response under oblique shear (right).
lateral loading, and combinations of both, with the direction and magnitude varied during each record. The 3D reference force and magnetic-field signals are acquired synchronously. Five independent loading records are collected, comprising 304,870 synchronized magnetic-field and reference-force sample pairs. The data cover force ranges of N for , N for , and N for , and include continuous loading processes with varying directions and magnitudes. The resulting multidirectional contact data are used to establish the mapping between the magnetic-field response and the 3D contact force.
B. Causal History Features
The response of the flexible structure can depend on its recent loading history. To represent this temporal dependence, the current magnetic readout is augmented with causal history features. Let denote the baseline-corrected three-axis magnetic readout. In addition to the current readout, historical differences at two time scales, 40 ms and 120 ms, are introduced to represent recent changes in the magnetic response. For a time interval , we define
and construct the nine-dimensional input
Historical samples are selected by timestamp using the latest available data point no later than the target historical time. This feature construction uses only current and past information and can therefore be computed point by point during continuous data acquisition. The current readout represents the magnetic
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. XX, NO. XX, XXXX
(a)

(b)
Fig. 4. 3D force calibration setup and data acquisition interface. (a) Sensor installation and contact loading; (b) 3D reference force, magnetic readout, and synchronized recording.
state at the prediction time, while the two difference vectors describe its recent evolution over distinct intervals. Each vector contains all three magnetic channels, preserving cross-channel information in both the instantaneous and historical inputs. These differences are finite changes in the magnetic readout, rather than force derivatives or additional mechanical measurements.
C. 3D Force Reconstruction
CHFR maps the nine-dimensional causal history features to 3D contact forces using two parallel branches (Fig. 5): Extremely Randomized Trees (Extra Trees, ET) [27] and kernel-approximation ridge regression. The ET branch consists of 180 decision trees, with at least 15 samples per leaf, to learn the nonlinear mapping between the magnetic features and contact forces. In the kernel-regression branch, the input features are first standardized using StandardScaler, followed by an approximation of the radial basis function (RBF) kernel using 400 Nyström components [28], with kernel parameter and ridge regularization parameter . Each branch predicts , , and , and the predictions are averaged to obtain the final force estimate:
The ET branch represents the nonlinear mapping through local partitions, while the kernel-based branch provides a smooth nonlinear approximation. Both branches use the same inputs and predict forces in the same mechanical coordinate system.
Five-fold cross-validation holds out one complete calibration record per fold, with the remaining four records used for training. During training, up to 100,000 training points are randomly sampled per fold for the ET branch and up to 70,000 for the kernel-regression branch, while each test record is retained in full. A fixed random seed is used for all

Fig. 5. Causal history fusion regression (CHFR) model for 3D force reconstruction.
random sampling. Model selection follows the same record-level grouping scheme, and the final performance is calculated from the pooled out-of-fold predictions across the five test folds. Reconstruction performance is evaluated using the coefficient of determination , root-mean-square error (RMSE), and mean absolute error (MAE). For force component j, the two error metrics are
Here, N is the number of evaluated sample pairs, is the reference force, and is its prediction. The calibrated model provides three force components for contact monitoring and grasping feedback.
Record-level grouping evaluates transfer between complete loading sequences. This distinction matters for continuously acquired signals, because adjacent samples share similar contact states and overlapping histories. RMSE and MAE quantify force errors in newtons, whereas measures agreement relative to the variation of the reference component. The three metrics therefore provide complementary views of reconstruction performance.
IV. 3D FORCE SENSING PERFORMANCE
A. 3D Force Reconstruction
Fig. 6 summarizes reconstruction performance using the pooled out-of-fold predictions from the five held-out calibration records. The values for , , and are 0.93,
0.90, and 0.92, respectively, with corresponding RMSE values of 0.40, 0.57, and 0.69 N and MAE values of 0.25, 0.36, and 0.45 N. The agreement between predicted and reference forces supports simultaneous reconstruction of the three force components from the coupled magnetic measurements.
(a)

(b)
(c)
Reference (N)
Reference (N)
Reference (N)
Fig. 6. 3D force reconstruction results. (a) Coefficient of determination for each force component; (b) absolute-error distributions; (c) scatter plots of reference forces versus out-of-fold predictions with error metrics.
The dynamic-touch measurements below complement these aggregate metrics by comparing the timing, sign changes, and amplitudes of the reconstructed and reference forces. The robotic demonstrations then examine how the force outputs describe interactions and supply feedback during grasping. These evaluations connect force-estimation errors with the contact processes in which the estimates are used.
B. Dynamic Touch Response
To examine force tracking during dynamic contact, Mag-Cilia is mounted on the reference force sensor and loaded manually with a fingertip (Fig. 7(a)). Repeated pressing and release, lateral interaction, and combined loading are performed with varying contact magnitudes and repetition rates, including rapid successive contacts. The synchronously recorded reference forces are compared with the CHFR predictions in Fig. 7(b-e). During repeated indentation, the reconstructed normal force follows the establishment of contact, increase in load, and unloading. Under lateral interaction, the two tangential force components exhibit corresponding positive and negative variations with the interaction direction, while the normal force continues to reflect the contact compression state. For example, for the record shown in Fig. 7(b), the RMSE values of , , and are 0.05, 0.07, and 0.12 N, respectively. In Fig. 7(c), the predictions also track changes in the sign and magnitude of the tangential forces.
During combined loading, all three force components vary with the contact state and loading direction, and the predictions follow the temporal variations of the corresponding components. Across the valid paired time points in the four records shown in Fig. 7(b-e), the RMSE values range from 0.05 to 0.10 N for , from 0.07 to 0.12 N for , and from 0.12 to 0.19 N for . These records demonstrate tracking of normal and tangential force variations during the tested dynamic interactions.
V. DEMONSTRATION ON ROBOTIC GRASPING
A. CHFR-Based Force Feedback and Gripper Adjustment
MagCilia is mounted on the gripper of a robot (Franka Research 3). CHFR reconstructs , , and from the magnetic readout in real time and supplies these forces to the grasping controller. The experiment tests whether tangential-force feedback can support both grasp retention and handover. After a stable grasp is established, downward disturbances and additional loading are applied to emulate a tendency to drop; a person then supports and pulls the object upward for removal (Fig. 8(a)). The controller adjusts the gripper opening according to these load changes using the state logic in Fig. 8(b).
The reconstructed force signals are low-pass filtered with a time constant of 80 ms. Let denote the tangential force component aligned with the applied vertical loading, and let denote its baseline during stable grasping. The change passes through a deadband and a persistence criterion before entering the control logic. The logic issues closing, opening, or holding commands according to the load direction, normal force, and gripper state. Sustained downward loading triggers additional closure to strengthen the grasp, whereas sustained upward support or pulling triggers opening so that the person can take the object. When the tangential force returns to the baseline region, the gripper holds its current opening. The normal compressive force is defined as . Its raw and filtered values are used to monitor contact and limit further closure during adjustment.
Fig. 8(c) shows the reconstructed forces throughout the interaction. During the initial grasping stage from 2 to 14 s, remains near 1.1 N and the tangential forces remain close to zero. With additional external loading, the controller tightens the grasp, and increases to approximately 1.7 N during 18–24 s while increases to approximately 0.7 N. Further loading produces a peak of 3.91 N, accompanied by changes in the tangential forces. During upward support and object removal, the controller opens the gripper, and all three force components return to near zero after contact is released. The sequence demonstrates force-guided adjustment during loading and handover.
B. Stepwise Loading During Grasping
To examine the response to incremental tangential loading, weights are added to a grasped box in three successive steps, allowing the force response to settle after each addition (Fig. 9(a)). The resulting plateaus are compared in Fig. 9(b). Before loading, the mean reconstructed is 0.04 N. The mean values at the three stable plateaus increase to 0.08, 0.11, and 0.17 N, respectively. Meanwhile, increases from 0.32 to 0.48 N, while remains within a relatively small range. These distinct plateaus demonstrate the response to small load increments transmitted through the grasping interface, complementing the larger load changes in the gripper-adjustment experiment.
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. XX, NO. XX, XXXX
(a)

(b)
(c)
(d)
(e)
Fig. 7. Dynamic-touch response. (a) Fingertip loading and reference-sensor setup; (b-e) reference forces (red dashed) and predictions (blue solid) during contacts with varying magnitudes, directions, and repetition rates.
C. External Perturbations in Different Directions
To examine directional load changes at the grasping interface, the object is perturbed laterally and vertically after a grasp is established, while all three force components are recorded (Fig. 10). During lateral perturbation, varies bidirectionally over a range of N, accompanied by changes in and . Changing the perturbation direction produces different magnitudes and temporal responses across the three force components. During vertical perturbation, and span N and N, respectively, while reaches a peak of 2.41 N. The concurrent changes in normal and tangential forces characterize the combined interface loading caused by these perturbations.
VI. DEMONSTRATION ON SURFACE RECOGNITION
A. Active Scanning and Sample Composition
Beyond load sensing during grasping, active contact can also provide robots with tactile information about object surfaces [29]. Fig. 11(a) and Supplementary Fig. ??(a) show the robotic scanning setup. To acquire surface-dependent force fluctuations, the robot moves MagCilia along each sample surface and then reverses direction while maintaining contact. The three force components are recorded continuously, with each forward-and-return scan forming one trial. A total of 328 scanning trials are collected from six surface categories: acrylic, fabric, paper, PLA, rubber, and sponge.
The recognition pipeline converts the reconstructed force traces into frequency-domain features and classifies them using logistic regression (Fig. 11(b)). The feature construction and evaluation procedure are described below. The force spectra complement the amplitude differences illustrated in Supplementary Fig. ??(b). For example, the peak of the median normal-force curve is 2.50 N for paper and 0.73 N for sponge. Within-channel normalization emphasizes how spectral power is distributed across frequency bands rather than the overall force level.
B. Frequency-Domain Representation
For each scanning direction and force component, the power spectrum is estimated using Welch's method [30] and divided into 14 frequency bands. Each band power is divided by the total power across the 14 bands of that channel and scanning direction. A positive lower bound is applied to the normalized values before the base-10 logarithm to avoid taking the logarithm of zero. This normalization emphasizes relative spectral distributions and reduces dependence on overall signal amplitude. Concatenating features from two directions, three force components, and 14 frequency bands gives an 84-dimensional feature vector. The normalization formula and surface-dependent frequency-band analysis are provided in Supplementary Note ?? and Supplementary Fig. ??.
C. Classification Results
Fig. 11(c) shows the real-time robotic surface recognition experiment using MagCilia. The robot sequentially performs back-and-forth scans over the six surface categories. After each forward-and-return scan, the system extracts the frequency-band features, applies the trained classifier, and outputs the predicted surface category. The online demonstration correctly identified all six tested surfaces.
The complete dataset is further evaluated using three-fold offline cross-validation grouped by acquisition session. The 52
(a)

(b)
w, b
(c)
Fig. 8. Force-guided robotic grasping with MagCilia. (a) Grasping, perturbation, loading, and object-removal stages; (b) force-feedback and state logic for adjusting the gripper opening; (c) corresponding CHFR-reconstructed 3D forces.
(a)

(b)
Fig. 9. Stepwise loading during grasping. (a) Images of the three loading steps; (b) corresponding time series of the CHFR-reconstructed 3D forces.
acquisition sessions are assigned to folds so that no session appears in both the training and test sets within a fold. The 84-dimensional trial features are standardized using StandardScaler and classified using multiclass logistic regression. In each fold, StandardScaler is fitted on the training data and applied to the held-out sessions. After pooling the out-of-fold predictions from the three folds, 326 trials are correctly classified, yielding an overall accuracy of 99.39%, a balanced accuracy of 99.37%, and a macro-averaged F1 score of 0.99. The corresponding row-normalized confusion matrix is shown in Fig. 11(d). The grouped evaluation supports discrimination among the six surface categories across held-out acquisition sessions. The online experiment demonstrates the scan-to-prediction workflow on the robot. Its six tested surfaces
(a)
Lateral perturbation

Vertical perturbation
(b)
Fig. 10. Lateral and vertical perturbations during grasping. (a) Perturbation actions; (b) CHFR-reconstructed 3D forces and corresponding perturbation intervals.
provide a demonstration rather than a separate estimate of classification accuracy. The predicted labels describe the tested surface categories under the acquisition conditions represented in the dataset.
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. XX, NO. XX, XXXX
(a) Robot arm
(b)

Scanning
Material surface
Preprocessing
Trim 0.6 s
246 Hz
Detrend · normalize
Window 1
Welch PSD · log10
14 bands/channel → 42D
Window 2
Welch PSD · log10
14 bands/channel → 42D
Concat.
42 + 42
84D
StandardScaler
Logistic
regression
C = 1
Probabilities
argmax
6 materials
(c)
(d)
Force-domain accuracy: 99.39% (326/328)
Acrylic
Fabric
Paper
PLA
Rubber
Sponge
Fig. 11. Robotic surface scanning and recognition. (a) Robotic scanning setup with MagCilia; (b) 3D force frequency-band features and classification pipeline; (c) real-time robotic recognition demonstration for six surface categories; (d) row-normalized confusion matrix from three-fold session-grouped offline evaluation, with an overall accuracy of 99.39%.
VII. COMPARISON WITH RELATED WORK
Magnetic multi-axis tactile sensors typically combine magnetic-structure design with signal reconstruction to map contact-induced structural deformation to force information along different directions (Table I). Yan et al. used a sinusoidally magnetized film to achieve self-decoupled sensing of the normal force and one tangential force component [17], and further employed two orthogonally magnetized film layers to extend the measurement of a single tactile unit to three force components [18]. Another class of studies exploits the bending and orientation changes of magnetic cilia to acquire contact information. Man et al. combined magnetic-cilia arrays with magnetic-sensor arrays to achieve sliding sensing and object recognition through spatiotemporal magnetic responses [20]. Li et al. used the giant magnetoimpedance effect of amorphous soft-magnetic ribbons to sense weak tangential interactions [21]. Liu et al. also developed a segmented-beam model comprising a nonmagnetic base segment and a magnetic tip to describe cilia deformation and magnetic response, and further applied it to sensing flow direction and surface texture [22].
MagCilia uses a single magnetociliary contact unit and a single Hall sensor to acquire contact-induced changes in the magnetic field, and CHFR simultaneously reconstructs , , and from the coupled magnetic responses. The reconstructed 3D forces are then used for force feedback during robotic grasping and, through frequency-domain features obtained during active scanning, for surface recognition. The reported studies use different sensing tasks and performance metrics, so Table I provides a functional comparison rather than a direct ranking of force accuracy.
VIII. Conclusion
Robotic manipulation requires compact tactile sensors capable of resolving multidirectional contact forces while providing rich information about physical interactions. We present MagCilia, a single-unit magnetociliary tactile sensor that combines a flexible magnetic-cilia structure with a single Hall sensor for 3D force sensing. CHFR reconstructs the three force components with RMSEs of 0.40, 0.57, and 0.69 N for , , and , respectively, in grouped five-fold cross-validation. Robotic experiments demonstrate tangential-force-guided gripper adjustment during external loading and handover, together with monitoring of multidirectional perturbations. Frequency-domain force features classify six surface categories with 99.39% accuracy in three-fold offline cross-validation grouped by acquisition session. The online demonstration correctly identified all six tested surfaces. These results demonstrate how one tactile unit can provide both quantitative contact-force feedback and surface information through the same reconstructed signals. Future work will optimize the magnetic composite and cilia geometry and integrate a Hall-sensor array to enhance force-reconstruction accuracy and spatial resolution, supporting general robotic applications.
REFERENCES
[1] Q. Li, et al., “A review of tactile information: Perception and action through touch,” IEEE Transactions on Robotics, vol. 36, no. 6, pp. 1619–1634, 2020.
[2] Z. Lu et al., “Gtac-hand: A robotic hand with integrated tactile sensing and extrinsic contact sensing capabilities,” IEEE/ASME Transactions on Mechatronics, vol. 28, no. 5, pp. 2919–2929, 2023.
[3] C. Lu, et al., “Dexitac: Soft dexterous tactile gripping,” IEEE/ASME Transactions on Mechatronics, vol. 30, no. 1, pp. 333–344, 2025.
[4] L. Mo, et al., “A highly sensitive, compact, and low-cost soft triaxial optical force (stof) sensor for robotic grasping and human–machine interaction,” IEEE Transactions on Industrial Electronics, vol. 73, no. 1, pp. 1469–1480, 2026.
TABLE I COMPARISON OF MAGCILIA WITH REPRESENTATIVE MAGNETIC TACTILE SENSORS.
| Sensor | Configuration | Capability | Quantitative performance |
|---|---|---|---|
| [17] | Magnetized film with Hall sensing | Normal and 1D tangential force | Sensitivity: 0.01 kPa (normal), 0.10–0.27 kPa (tangential) |
| [18] | Stacked magnetic films with a 3 × 3 Hall array | 3D force sensing | Range: 28 N (normal), ±8 N (tangential) |
| [20] | Magnetic-cilia array with a 2 × 4 sensor array | Tangential force and direction | Resolution: 0.2 mN |
| [21] | Soft-magnetic cilia with an induction coil | Weak tangential force sensing | Sensitivity: 10.03%/mN |
| [22] | Segmented magnetic cilia | Flow and texture sensing | Flow-direction error: < 10° |
| [23] | Magnetic cilia with a single Hall sensor | Normal force and tangential direction | Normal sensitivity: 0.02 N; |
| This work | Magnetic cilia with a single Hall sensor | 3D force sensing | RMSE: 0.40/0.57/0.69 N; : 0.93/0.90/0.92 |
[5] S. Chen, et al., “Flexible piezoresistive three-dimensional force sensor based on interlocked structures,” Sensors and Actuators A: Physical, vol. 330, p. 112857, 2021.
[6] Y. Feng, et al., “Intrinsic force–temperature self-decoupling enables human-like tactile sensing in a soft ionic skin,” ACS Nano, vol. 20, no. 31, pp. 22 195–22 214, 2026.
[7] F. Xiang, et al., “Highly sensitive aquatic iontronic-based tri-axis force sensor array for underwater robotic gripping,” IEEE Transactions on Instrumentation and Measurement, vol. 74, pp. 1–10, 2025.
[8] Y. Feng, et al., “A soft mechanoluminescent skin for high-resolution optical tactile sensing in human–machine interaction,” Advanced Science, vol. 13, no. 42, p. e75507, 2026.
[9] T. Li, et al., “A fingertip optical fiber composite sensor with conformal design for robotic perception of tactile force,” IEEE/ASME Transactions on Mechatronics, vol. 30, no. 2, pp. 1523–1535, 2025.
[10] Y. Wang, et al., “Flexible robotic hand harnesses large deformations for full-coverage human-like multimodal haptic perception,” Nature Communications, vol. 17, no. 1, p. 458, 2026.
[11] S. Cui, et al., “In-hand object localization using a novel high-resolution visuotactile sensor,” IEEE Transactions on Industrial Electronics, vol. 69, no. 6, pp. 6015–6025, 2022.
[12] Y. Wang, et al., “Relaxation-aware multimodal sensing of soft gripper driven by structure-perception-learning,” arXiv preprint arXiv:2608.26622, 2026.
[13] B. Fang, et al., “Soft magnetic fingertip with particle-jamming structure for tactile perception and grasping,” IEEE Transactions on Industrial Electronics, vol. 70, no. 6, pp. 6027–6035, 2023.
[14] M.-J. Gui, et al., “A novel orthogonal halbach bilayer for super-resolution tactile perception,” IEEE/ASME Transactions on Mechatronics, vol. 30, no. 6, pp. 7866–7877, 2025.
[15] J. Man, et al., “Recent progress of biomimetic tactile sensing technology based on magnetic sensors,” Biosensors, vol. 12, no. 11, p. 1054, 2022.
[16] S. Peng, et al., “Flexible magnetic tactile sensors: Materials, working principles, and applications—a review,” Materials Today Physics, vol. 59, p. 101926, 2025.
[17] Y. Yan, et al., “Soft magnetic skin for super-resolution tactile sensing with force self-decoupling,” Science Robotics, vol. 6, no. 51, p. eabc8801, 2021.
[18] Y. Yan, et al., “A soft skin with self-decoupled three-axis force-sensing taxels,” Nature Machine Intelligence, vol. 6, no. 11, pp. 1284–1295, 2024.
[19] J. Li, et al., “A tactile sensor based on magnetic sensing: Design and mechanism,” IEEE Transactions on Instrumentation and Measurement, vol. 73, pp. 1–9, 2024.
[20] J. Man, et al., “Magnetic tactile sensor with bionic hair array for sliding sensing and object recognition,” Advanced Science, vol. 11, no. 12, p. 2306832, 2024.
[21] X. Li, et al., “Bioinspired cilia tactile sensor based on soft magnetic amorphous ribbon,” IEEE Transactions on Instrumentation and Measurement, vol. 74, pp. 1–8, 2025.
[22] K. Liu, et al., “Modeling and optimization of biomimetic magnetic cilia for multifunctional tactile sensor,” Advanced Materials Technologies, vol. 11, no. 3, p. e01095, 2026.
[23] Y. Feng, et al., “A bioinspired soft magnetociliary tactile sensor for direction-sensitive interaction sensing,” IEEE Transactions on Instrumentation and Measurement, vol. 75, pp. 9531 313–9531 313, 2026.
[24] X. Ji, et al., “Design of ndfeb-silicone based magnetic tentacle sensor with texture and shape recognition,” Measurement, vol. 258, p. 119385, 2026.
[25] M.-J. Gui, et al., “Soft magnetic skin’s deformation analysis for tactile perception,” IEEE Transactions on Industrial Electronics, vol. 70, no. 12, pp. 12 883–12 893, 2023.
[26] H. Zhu, et al., “Effect of elastic layer geometry on the range and sensitivity of flexible magnetic tactile sensor,” IEEE Transactions on Instrumentation and Measurement, vol. 75, pp. 1–10, 2026.
[27] P. Geurts, et al., “Extremely randomized trees,” Machine Learning, vol. 63, no. 1, pp. 3–42, 2006.
[28] C. K. I. Williams et al., “Using the nyström method to speed up kernel machines,” in Advances in Neural Information Processing Systems, T. K. Leen, et al., Eds., vol. 13. MIT Press, 2001, pp. 682–688, nIPS 2000 conference.
[29] L. Qin, et al., “Surface recognition with a tactile finger based on automatic features transferred from deep learning,” IEEE Transactions on Instrumentation and Measurement, vol. 73, pp. 1–10, 2024.
[30] P. Welch, “The use of fast fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms,” IEEE Transactions on Audio and Electroacoustics, vol. 15, no. 2, pp. 70–73, 1967.

and robot manipulation.
Yu Feng (Member, IEEE) received the B.Eng. degree in Measurement and Automation from Harbin Engineering University, Harbin, China, in 2020, and the Ph.D. degree in Mechanical Engineering from City University of Hong Kong, Hong Kong SAR, in 2024. He subsequently worked as a postdoctoral fellow at City University of Hong Kong from 2024 to 2026. He is currently a research fellow with the Department of Mechanical Engineering, National University of Singapore, Singapore. His research interests include robotic perception, tactile sensors,

Hao Wu (Student Member, IEEE) received the B.E. degree in Mechanical Engineering from Zhejiang University, China, in 2024. From 2024 to 2026, he worked as a research assistant with the Grasp Lab at Zhejiang University. He is currently pursuing a Ph.D. degree at the National University of Singapore, Singapore, under the supervision of Prof. Jianshu Zhou. His research interests include mechanism design, soft robotics, and multimodal tactile perception.
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. XX, NO. XX, XXXX

Haotian Guo received the B.Eng. degree in micro-electromechanical systems engineering from Northwestern Polytechnical University, Xi'an, China, in 2026. He is currently pursuing a master's degree in mechanical engineering at the National University of Singapore, Singapore. His research interests include tactile sensing, sensor design, and robotic perception.

Haoming Liu received the B.Sc. degree in optoelectronic information science and engineering from Sun Yat-sen University in 2026. He is currently working with the G&M Lab, National University of Singapore, focusing on robot control, robotic manipulation, and multimodal perception.

William Su (Student Member, IEEE) is currently working toward the B.S. degree in aerospace engineering at the University of California, Berkeley, Berkeley, CA, USA. His research interests include dexterous manipulation, robotic end-effector design, and multimodal sensing.

Jingxiang Guo is a Ph.D. student at the National University of Singapore, in the Language and Vision Lab (LV-Lab), advised by Prof. Shuicheng Yan and co-supervised by Prof. Jianshu Zhou (G&M Lab). He received his M.Comp. in AI from NUS and his B.Eng. in Automation from HITSZ.

Jiankun Li (Student Member, IEEE) received the bachelor's degree in automation engineering from Nanjing University of Aeronautics and Astronautics, Nanjing, China, in 2023, and the master's degree in electronic engineering from the University of Hong Kong, Hong Kong SAR, in 2024. He is currently pursuing a Ph.D. degree with the Department of Mechanical Engineering, City University of Hong Kong, Hong Kong SAR. His current research interests include tactile sensors and artificial intelligence.

Masayoshi Tomizuka (Life Fellow, IEEE) was born in Tokyo, Japan, in 1946. He received the B.S. and M.S. degrees in mechanical engineering from Keio University, Tokyo, Japan, in 1968 and 1970, respectively, and the Ph.D. degree in mechanical engineering from the Massachusetts Institute of Technology, Cambridge, MA, USA, in February 1974. In 1974, he joined the Faculty of the Department of Mechanical Engineering, University of California at Berkeley, Berkeley, CA, USA, where he is currently the Cheryl and John Neerhout, Jr., Distinguished
Professorship Chair. At UC Berkeley, he teaches courses in dynamic systems and controls. From 2002 to 2004, he was the Program Director of the Dynamic Systems and Control Program of the Civil and Mechanical Systems Division of NSF. His current research interests are optimal and adaptive control, digital control, signal processing, motion control, and control problems related to robotics, machining, manufacturing, information storage devices, and vehicles. Dr. Tomizuka was the Technical Editor of the ASME Journal of Dynamic Systems, Measurement and Control, J-DSMC (1988–1993), Editor-in-Chief of the IEEE/ASME Transactions on Mechatronics (1997–1999), and Associate Editor for the Journal of the International Federation of Automatic Control, and Automatica. He was the General Chairman of the 1995 American Control Conference and was the President of the American Automatic Control Council (1998–1999). He is a Life Fellow of the ASME and a Fellow of the International Federation of Automatic Control (IFAC) and the Society of Manufacturing Engineers. He was the recipient of the Best J-DSMC Best Paper Award (1995, 2010), DSCD Outstanding Investigator Award (1996), Charles Russ Richards Memorial Award (ASME, 1997), Rufus Oldenburger Medal (ASME, 2002), John R. Ragazzini Award (AACC, 2006), Richard E. Bellman Control Heritage Award (AACC, 2018), Honda Medal (ASME, 2019), and Nathaniel B. Nichols Medal (IFAC, 2020). He is a member of the National Academy of Engineering.

Wen Jung Li (Fellow, IEEE) received the B.S. and M.S. degrees in aerospace engineering from the University of Southern California, Los Angeles, CA, USA, in 1987 and 1989, respectively, and the Ph.D. degree in aerospace engineering from the University of California at Los Angeles, in 1997. He worked in the Department of Mechanical and Automation Engineering, the Chinese University of Hong Kong (CUHK), from 1997 to 2011. Prior to CUHK, he held research and development positions with the NASA/Caltech Jet Propulsion Laboratory, Pasadena, CA, USA; The Aerospace Corporation, El Segundo, CA, USA; and Silicon Microstructures Inc., Fremont, CA, USA. He is honored as an International Fellow of The Canadian Academy of Engineering (CAE), a Fellow of US National Academy of Artificial Intelligence (NAAI), a Fellow of European Academy of Engineering (EAE), an IEEE Fellow, an ASME Fellow, an Asia-Pacific AI Association (AAIA) Fellow, and a 100 Talents of the Chinese Academy of Sciences. He served as the President of the IEEE Nanotechnology Council in 2016 and 2017. He currently holds a Chair Professorship of the Department of Mechanical Engineering and serves as the Vice-President (Talent and International Strategy) with the City University of Hong Kong, Hong Kong. His research interests encompass AI-enabled sensors, multimodal tactile sensing, and intelligent cyber-physical sensors.

Jianshu Zhou (Member, IEEE) received the Ph.D. degree in mechanical engineering from The University of Hong Kong, Hong Kong, in 2020. He is currently an Assistant Professor with the Department of Mechanical Engineering, National University of Singapore, Singapore. Prior to joining NUS, he held research positions at the University of California, Berkeley, and The Chinese University of Hong Kong. His research interests include robotics and mechatronics, robotic grasping and manipulation, embodied intelligence and physical AI, and multi-modal sensing, data acquisition, and interaction. Dr. Zhou was the recipient of several international conference Best Paper Awards and Finalist recognitions and the ASME DSCD Rising Star Award in 2025. He currently serves as an Associate Editor for the IEEE Robotics and Automation Letters and a Technical Editor for the IEEE/ASME Transactions on Mechatronics. He is also a Member of ASME.