Manuscript Offprint

arXiv:2611.01631

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

Bradley J Erickson, Sara Salehi

Abstract

Purpose. To compare two multimodal System 1 decision models, Clef 27B and d1 3B, with Clef's generative backbone read out with no fine-tuning (zero-shot), with a traditional LLM (Qwen 3.8-27B) operating in single token output mode on seven radiology tasks covering text, radiographs, CT and MRI.

Methods. Three models were run locally on a single NVIDIA DGX Spark (GB10): Clef, a 27B System 1 decision model based on Qwen3.8-27B; its backbone Qwen3.8-27B; and d1, a 3B System 1 decision model. Clef and d1 returned a probability for every option in one non-autoregressive pass. Qwen3.8-27B was forced to output a single token as the probability distribution over the option letters specified in the prompt. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports (n = 1,000, 18 findings); 2. Presence of finding in PadChest chest radiograph reports (n = 1,000, 20 findings); 3. the same 18 findings on CT-RATE chest CT but 3D volumes (n = 100); 4. MR safety status of devices from FDA AccessGUDID device records (n = 999); 5. line and tube position on RANZCR CLIp chest radiographs (n = 500, 11 labels); 6. motion-artifact severity on MR-ART T1-weighted brain MRI (n = 436) and 7. sequence identification on BraTS 2021 brain MRI (n = 400). The primary endpoint was AUROC with a 95% case-bootstrap confidence interval. These are all 'One-shot'--there was no fine-tuning of the models on the tasks.

Results. All three models completed all 4,435 tests without a failed request. All three retrieved findings from reports almost perfectly (AUROC 0.95–0.99). Clef ranked higher than its Qwen backbone on CT-RATE volumes (0.749 vs 0.668; paired Δ\Delta +0.082, 95% CI +0.045 to +0.119) and RANZCR (0.812 vs 0.766; Δ\Delta +0.046, +0.021 to +0.074) and lower on MR-ART (0.625 vs 0.709; Δ\Delta -0.084, -0.103 to -0.065). The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. Clef changed decisions more than ranking. On BraTS it correctly identified 90 of 100 FLAIR volumes, a class its backbone never chose, and accuracy rose from 0.615 to 0.888. On CT-RATE volumes and RANZCR, its backbone answered "yes" to 88% and 65% of finding questions against prevalence of 17% and 13%. Clef answered "yes" to 19% and 3%, and expected calibration error fell from 0.436 to 0.072 and from 0.255 to 0.025. The 3B model d1 ranked lower than Clef on six of seven tasks, by 0.03–0.04 on reports and by 0.13–0.28 on BraTS, GUDID, CT-RATE volumes and RANZCR. No model handled motion severity: each labelled at least 99% of MR-ART scans "none or minimal". Clef was 1.5 to 2.9 times faster per request than its backbone on tasks with 18 or 20 questions per input, where one pass replaced many calls, but slower on single-question tasks. d1 used 3 to 9 times less energy per request than Clef.

Conclusion. System 1 models can perform important tasks in radiology with high accuracy, at far lower compute cost than LLMs used in the usual way, with reasoning and free-text answers. When an LLM is constrained to a single answer token, its cost per question is similar to System 1 models, and a System 1 model is faster only when it answers several questions in one pass. A System 1 head on the same backbone added little discrimination on report text, but it gave more usable decisions on MRI sequences and better calibration on chest radiograph and CT findings. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity, and rare findings still needed per-label thresholds for satisfactory performance. Probability readouts, whether from a dedicated head or a general-purpose model, need local calibration before they can act as decision components in radiology.

Introduction

Many radiology decisions are a choice among a few fixed options made in large numbers: which sequence a series is, whether a line is in the right place, whether motion makes a scan non-diagnostic, and whether an implant is safe for MRI scanning. A model that makes such decisions must also say how certain it is, so that confident answers can be acted on and uncertain ones routed to a radiologist. Generative language models answer in free text, often after 'reasoning', which is slow, costly and gives poorly calibrated confidence. System 1 models instead return a probability for every option in a single forward pass through a model.

Decision models, also known as 'System 1' models, have recently gained attention (https://docs.typesafe.ai/introduction) because of their speed and reduced cost for making decisions as opposed to generating free text. Yang, Vrettos et al. recently evaluated four System 1 models zero-shot on 86 public tasks across medicine (arXiv:2610.31315). They found that findings stated in radiology reports were retrieved almost perfectly (AUROC up to 1.00), while performance fell with each step from radiograph perception (mean AUROC 0.89) to 2D findings (0.84) to 3D CT and MRI volumes (0.69). Three of their tasks are repeated here: MR safety status of devices, their weakest text task (best AUROC 0.66), MRI motion-artifact severity (about 0.71), and line and tube position on chest radiographs. They also compared each open System 1 model with its own generative backbone. The backbones were 3 to 5 percentage points more accurate but worse calibrated, and 11 to 76 times slower.

In this manuscript, we refer to the “backbone” as the pretrained vision-language model, here Qwen3.8-27B. It turns the image and text into an internal representation. The “head” is the final stage that turns that representation into an answer, and the two models’ heads work differently:

  • Generative head: predicts the next token over its whole vocabulary. Each token (~ word) generated requires at least one pass through the model (more with reasoning). To get a forced choice as a single token out, you prompt it to answer using one of the choices and read the probabilities it gives each option. That’s the readout used for Qwen3.8-27B.
  • System 1 decision head (Clef, d1): predicts among the question’s declared options directly, returning one probability per option in a single pass. It can also answer multiple questions in a single pass.

This manuscript addresses three questions open for radiology. First, does a dedicated decision head perform better than its backbone, when the backbone's thinking is turned off and it generates a single answer token? Second, can a much smaller (3 billion parameters) System 1 model stand in for a larger one (27 billion parameters)? Third, how much does the choice of backbone matter? The open System 1 model Clef is fine-tuned from Queen 3.8-27B, so the two can be run side by side on the same weights. This study compared Clef, Qwen3.8-27B and the 3B System 1 model d1 on seven tasks: finding presence in chest CT reports, chest radiograph reports and chest CT volumes, MR safety from device records, line and tube position on chest radiographs, motion severity on brain MRI, and sequence identification on brain MRI. The question was whether the head, model size or a newer backbone improves discrimination, and whether better discrimination carries over to usable decisions. We also describe the use of a traditional generative large language model (LLM) running in a single output token mode rather than the usual free text output form.