arXiv(opens in a new tab)cs.LGOct 2026Cited by 1 paper on PaperVantage

Manuscript Offprint

arXiv:2610.31315

The Value of System 1 Models in Medicine

Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt, Johannes Moll, Anirudh Narayanan, Frederike Stumpf, Cosmin I. Bercea, Jiawen Wang, Evangelia E. Vassalou, Krischan Braitsch, Sebastian Ziegelmayer, Markus Graf, Marcus R. Makowski, Lisa Adams, Nassir Navab, Michail E. Klontzas, Keno Bressem

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Xiufeng Yang1,∗^{1,*}, Konstantinos Vrettos2,∗^{2,*}, Zeineb Ben Chaaben1^{1}, Fabian Drexel1^{1}, Jannik Lübberstedt1^{1}, Johannes Moll1^{1}, Anirudh Narayanan1^{1}, Frederike Stumpf1^{1}, Cosmin I. Bercea1^{1}, Jiawen Wang1^{1}, Evangelia E. Vassalou3^{3}, Krischan Braitsch4^{4}, Sebastian Ziegelmayer1^{1}, Markus Graf1^{1}, Marcus R. Makowski1^{1}, Lisa Adams1^{1}, Nassir Navab5^{5}, Michail E. Klontzas2,3,6,+^{2,3,6,+}, Keno Bressem1,7,8,9,+^{1,7,8,9,+}

Abstract

Background Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown.

Methods Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging (radiography, CT and MRI). Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models.

Results Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings, with 0.54 for pulmonary embolism on CT. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy.

Conclusions System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

INTRODUCTION

Many clinical decisions represent choices among a few fixed options that must be made quickly and in bulk. A triage nurse assigns one of five acuity levels within minutes of arrival, a radiologist decides whether a CT pulmonary angiogram demonstrates embolism, and a coder selects one procedure code for each of thousands of cases. A model that makes such decisions must also state how certain it is, so that confident answers can be acted on and uncertain cases passed to a clinician. 1−3^{1-3} Generative large language models perform well on a series of medical tasks, 4;5^{4;5} but they write each answer token by token, often following a reasoning trace, which takes several seconds per decision and uses far more energy than a task-specific model. 6^{6} The confidence they state in text is poorly calibrated and barely separates correct from incorrect answers. 7;8^{7;8} On the contrary, System 1 models receive a state, such as a report, an image or both, together with one or more typed questions, and return a probability for every answer option in a single forward pass without generating text. Their name refers to dual-process theory, which separates fast, intuitive System 1 judgement from slow, deliberate System 2 reasoning, the mode that generative models resemble when they reason in text. 9;10^{9;10}

The open question is which clinical decisions such a model can be trusted with. The answer to a clinical case can be stated in a report, recalled from medical knowledge, judged from several findings, or seen in an image. Of 519 studies of large language models in health care, 44.5% tested medical knowledge such as licensing-

1^{1}Department of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany. 2^{2}Artificial Intelligence and Translational Imaging Lab, Department of Radiology, School of Medicine, University of Crete, Heraklion, Greece. 3^{3}Department of Medical Imaging, University Hospital of Heraklion, Heraklion, Crete, Greece. 4^{4}Department of Medicine III, School of Medicine and Health, Technical University of Munich, Munich, Germany. 5^{5}Chair for Computer Aided Medical Procedures and Augmented Reality, School of Computation, Information and Technology, Technical University of Munich, Munich, Germany. 6^{6}Division of Radiology, Department for Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden. 7^{7}National Center for Tumor Diseases West, Essen, Germany. 8^{8}Institute of Artificial Intelligence in Medicine, University Hospital Essen, Essen, Germany. 9^{9}Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany. ∗^{*}These authors contributed equally.

examination questions, and 5% used real patient-care data. 11^{11} Where other tasks were tested, performance fell from more than 86% on licensing-examination questions 12^{12} to lower accuracy on real clinical cases and conversations. 13;14^{13;14} On radiologic images, GPT-4V identified the imaging modality in all 515 images but detected abnormalities in 0% to 90%, depending on the finding, 15^{15} and multimodal models scored lower on volumetric than on two-dimensional images. 16^{16} If performance depends on where the answer lies, a single benchmark score misrepresents a model, a construct-validity problem known from general AI benchmarks. 17^{17}

To evaluate the value of System 1 models in medicine, we tested four models on 86 tasks from 14 clinical domains, with the tasks ordered in six capability tiers from medical knowledge to volumetric findings. We measured which clinical decisions the models can take on, whether their probabilities are calibrated, how they perform outside English, and what their speed costs in time, money, energy and accuracy, against a generative model of the same family.

References (95)