arXiv:2608.14422eess.IVAug 2026

Manuscript Offprint

arXiv:2608.14422

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya

Abstract

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

Mahdi Saberi, Toygan Kiliç, and Mehmet Akçakaya
Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA

Index Terms— Phase regularization, magnitude regularization, data fidelity, partial Fourier, unrolled network

1 Introduction

Magnetic resonance imaging (MRI) is a powerful diagnostic imaging modality, but its relatively slow acquisition may lead to patient discomfort and motion artifacts [31, 6, 5]. Accelerated MRI techniques address this limitation by acquiring undersampled k-space measurements, and performing image reconstruction by solving an ill-posed inverse problem [1, 7]. Parallel imaging (PI) leverages multi-coil sensitivity information [22], while compressed sensing (CS) uses image sparsity through regularized reconstruction [15]. Partial Fourier (PF) imaging provides additional acceleration in Cartesian MRI by acquiring only a fraction of k-space along the phase-encoding direction; however, recovering the omitted measurements is challenging due to the complex-valued nature of MRI data and its dependence on image phase [10]. Recently, deep learning (DL) methods have achieved state-of-the-art performance for accelerated MRI reconstruction [8, 11, 26]. In particular, physics-driven deep learning (PD-DL) methods integrate learned image priors with the MRI forward encoding model through algorithm unrolling, enabling reconstruction of complex-valued images from undersampled measurements [8, 1].

Figure

Fig. 1: Comparison between conventional PD-DL and the UMPIRE-Net architecture for accelerated MRI reconstruction.

Conventional PD-DL methods typically reconstruct complex images directly, thereby coupling magnitude and phase information within a single learned regularizer. Although this strategy has been highly effective for accelerated MRI, directly applying conventional PD-DL to partial Fourier data without PF-specific phase modeling or post-processing may be suboptimal. Since the recovery of the omitted k-space measurements in PF depends on the image phase [20], this causes issues especially for unsupervised training setups [3, 27, 16], where the non-acquired PF region is not directly included in the training loss, providing limited guidance for recovering these omitted k-space samples. On the other hand, classical PF reconstruction methods, such as homodyne reconstruction and POCS, explicitly use phase information to estimate the missing asymmetric k-space region [20, 17]. This suggests that magnitude and phase, which exhibit distinct spatial characteristics and play different roles in PF recovery, may benefit from being modeled separately within a PD-DL reconstruction framework.

Several prior works have explored separate magnitude and phase reconstruction [32, 21, 14]. A separate magnitude and phase reconstruction was proposed in [32] within a CS framework, using dedicated phase regularization to improve stability. Another line of CS-based work modeled magnitude and phase separately, and introduced phase cycling to address phase wrapping [21]. More recently, learning-based methods have used neural networks to reconstruct or refine magnitude and phase components separately [14]. However, these approaches either rely on conventional non-DL optimization frameworks [32, 21] or use neural networks outside a physics-driven unrolled reconstruction framework [14].

In this work, we propose Unrolled Magnitude-Phase In REgularization Network (UMPIRE-Net) for MRI Reconstruction. In particular, we solve the reconstruction inverse problem by independently regularizing magnitude and phase components with a novel data-fidelity unit. We evaluate UMPIRE-Net on accelerated Cartesian acquisitions with PF and in-plane undersampling across multiple datasets and acceleration rates. Results demonstrate that explicitly decoupling magnitude and phase regularization improves reconstruction quality compared to conventional complex-valued PD-DL methods, both quantitatively and qualitatively.