Cross-Model Agreement as a Deployment-Time Reliability Signal for Automatic Polyp Segmentation

Siddharth Gupta, Jitin Singla

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Based Quality Estimation (RBQE), a reference-free framework measuring agreement between a primary segmentation model and an independently trained referee on the same image. RBQE is evaluated on a standardized 1,223-image external benchmark drawn from four public datasets, using four referee configurations chosen to separate two design axes: referee independence and architectural diversity. Using a common Agreement Dice descriptor, a same-architecture referee differing from the primary model only in random initialization already yields a useful reliability signal (ROC-AUC = 0.923), showing that independent training alone is sufficient. Cross-architecture referees improve further: SegFormer-B0 achieves the strongest performance (ROC-AUC = 0.960), significantly outperforming the same-architecture control and UNet++, and exceeding a representative Test-Time Augmentation baseline by 0.055 ROC-AUC under an identical protocol, whereas a prompt-coupled MedSAM referee underperforms despite maximal architectural diversity. Because empty-mask agreement is trivially separable, we also report a restricted evaluation excluding such cases: ROC-AUC falls to 0.876 (SegFormer-B0, 1,046 images) and 0.783 (same-architecture control, 975 images), yet RBQE's margin over both baselines widens on this identical subset. RBQE additionally increases the mean Dice of retained predictions as low-agreement cases are progressively rejected, supporting selective prediction, and requires only one additional deterministic referee forward pass at inference. Our study therefore supports cross-model agreement as a practical, interpretable reliability framework for automated polyp segmentation.

Keywords: Segmentation quality estimation, Polyp segmentation, Reliability estimation, Model agreement, Deep learning, Colonoscopy

1. Introduction

Colorectal cancer (CRC) is the third most commonly diagnosed cancer and the second leading cause of cancer-related death worldwide, with an estimated 1.93 million new cases and 904,000 deaths reported globally in 2022 [1]. Timely detection and removal of precancerous polyps substantially improves patient survival, and colonoscopy remains the gold-standard technique for early polyp detection. However, colonoscopy is resource-intensive, requires specially trained endoscopists, and its diagnostic yield is highly dependent on operator experience — a meta-analysis of 43 tandem-colonoscopy studies (>15,000 procedures) reported an adenoma miss rate of 26% (95% CI: 23-30%) [2].

Deep learning has substantially advanced automatic polyp segmentation, enabling more accurate lesion delineation and supporting computer-aided diagnosis (CAD) systems [3]. Despite this progress, segmentation models continue to fail under challenging imaging conditions such as camera motion, poor illumination,

*Corresponding author Email address: jsingla@bt.iitr.ac.in (Jitin Singla) URL: https://www.jitinsingla.in/ (Jitin Singla) specular artifacts, blur, very small polyps, and domain shift across imaging hardware. Because ground-truth annotations are unavailable at inference, such failures cannot be detected using standard metrics like the Dice Similarity Coefficient (DSC) or Intersection-over-Union (IoU), leaving clinicians and downstream decision-support systems with no reliable mechanism for flagging an unreliable segmentation before it informs diagnosis.

This gap has motivated no-reference Segmentation Quality Estimation (SQE), whose objective is to estimate segmentation reliability when ground-truth annotations are unavailable at inference. As detailed in Section 2, existing SQE approaches derive their quality signal either from a single model's own behavior (confidence scores, predictive entropy, Monte Carlo (MC) Dropout, Test-Time Augmentation(TTA)), from disagreement among ensembles of identically architected models, or from per-image reverse-classifier fitting against a reference atlas; these families respectively inherit the deployed model's calibration errors, a shared architectural inductive bias, and a substantial per-image retraining cost. To date, agreement between architecturally heterogeneous, independently trained segmentation models — decoupled from any single model's calibration and requiring no per-image retraining — has not been systematically investigated as a deployment-time reliability signal for polyp segmentation.

In the present work, we propose Referee-Based Quality Estimation (RBQE), a simple and practical framework that estimates segmentation reliability using agreement between independently trained segmentation models. Rather than relying on a single model's internal confidence, RBQE assesses the coherence between a primary segmentation model and an independently trained referee model applied to the same image. The underlying hypothesis is that when independently trained models converge to similar segmentation masks, the prediction is more likely to be reliable, whereas substantial disagreement indicates an increased likelihood of segmentation failure. We frame the choice of referee along two design axes: (i) independence — whether the referee's training and, crucially, its inference-time output are decoupled from the primary model — and (ii) architectural diversity — whether the referee embodies a different inductive bias. The four referee configurations evaluated in this study (Section 3.4) are chosen to separate these axes: a same-architecture, independently trained control isolates the contribution of independence; two architecturally distinct, independently trained referees add diversity; and a prompt-driven foundation model that is architecturally diverse but functionally coupled to the primary prediction isolates the role of output-level independence. RBQE is not proposed to predict the exact Dice coefficient, nor does it seek to replace supervised quality estimation models; instead, it provides a practical, deployment-time reliability estimate capable of flagging unreliable predictions when ground-truth labels are unavailable.

To evaluate this hypothesis, external validation was performed on a standardized benchmark of 1,223 colonoscopy images drawn from four independent, publicly available datasets, with all headline results additionally reported on restricted subsets that exclude trivially separable empty-mask cases. The proposed framework was compared against representative uncertainty-based (TTA) and morphology-based quality estimation baselines under a standardized evaluation protocol, using ROC-AUC, bootstrap confidence intervals, paired DeLong significance testing, and computational complexity analysis.

The principal contributions of this work are as follows:

  1. Isolating the role of referee independence. Using a same-architecture control referee that differs from the primary model only in random initialization, we demonstrate that independent training alone, without architectural diversity, already provides a meaningful reliability signal (ROC-AUC = 0.923) — to the best of our knowledge, a distinction that has not been explicitly investigated in the SQE literature.

  2. Cross-architecture diversity adds a statistically significant increment. Agreement between the primary model and an independently trained, architecturally distinct referee (SegFormer-B0) provides the strongest deployment-time failure-detection signal (ROC-AUC = 0.960), significantly outperforming the same-architecture control and UNet++, and outperforming representative single-model uncertainty (TTA) and morphology-based baselines.

  3. Diversity without output-level independence fails. A prompt-driven foundation-model referee (MedSAM, ROC-AUC = 0.863), whose inference prompt is derived from the primary model's own prediction, underperforms even the same-architecture control despite maximal architectural diversity.

— identifying genuine output-level independence, rather than architectural difference alone, as the necessary ingredient of the agreement signal.

  1. A dual full/non-degenerate evaluation protocol. Because empty-mask agreement is trivially separable, all headline comparisons are reported both on the full standardized benchmark and on restricted subsets excluding degenerate cases (ROC-AUC 0.960 → 0.876 for SegFormer-B0; 0.923 → 0.783 for the same-architecture control); RBQE's margin over the evaluated baselines widens, rather than narrows, on the restricted subset.

  2. Practical, label-free, single-pass deployment. RBQE requires only one additional deterministic forward pass through a referee model at inference, with no per-image retraining, no quality-labelled training data, and no modification of the deployed primary model; five interpretable agreement descriptors are evaluated and ranked, and the continuous agreement score is shown to support selective prediction.