arXiv:2609.06382stat.MLSep 2026

Manuscript Offprint

arXiv:2609.06382

Recovering Weak Signals with Normalizing Flows

Sarod Yatawatta

Sarod Yatawatta*

ASTRON, Netherlands Institute for Radio Astronomy,

Oude Hoogeveensedijk 4, 7991 PD,

Dwingeloo, The Netherlands.

(Dated: September 9, 2026)

In many scientific disciplines, weak signals of interest are obscured by dominant nuisance signals that are several orders of magnitude stronger. Recovering these weak signals requires subtracting the dominant ones; however, this calibration process inherently distorts or partially suppresses the underlying signal of interest. To address this problem, we propose the use of normalizing flow models to reconstruct calibration-affected weak signals. By leveraging the statistical invariance of the target signals and assuming minimal initial suppression, our framework effectively recovers the lost signal components. We provide a comprehensive theoretical overview of this normalizing flow-based recovery method and demonstrate its efficacy using simulated data.

Keywords: Deep learning, Generative models, Cosmology, Radio telescopes, Cosmic microwave background

I. INTRODUCTION

Many disciplines in physics rely on the accumulation of observational data and the recovery of weak, hidden signals in that data. A case in point are the signals that originate from the Universe that feed several research areas in cosmology. Such signals have statistical stability as an advantage but they are overwhelmed by nuisance signals that are of many orders of magnitudes higher in power level (e.g., Galactic and extra-Galactic foregrounds).

The estimation and the removal of nuisance signals from the observed data are performed by many specialized techniques unique to each scientific discipline but in this paper, we broadly consider them to be a form of calibration. In calibration, a parameterized model for the nuisance signals are constructed and subtracted from the data (see Fig. 1). The desired weak signals are assumed to remain intact in the residual. Due to the statistical stability of the weak, hidden signals, it is generally assumed that the residual data can be accumulated without any limit to reach the desired dynamic range for their detection.

The statistical performance of calibration (in radio interferometry) has been studied both theoretically [e.g., 1, 2] and empirically [e.g., 3–5]. Its effect on the residual and on the weak signals hidden in the residual is well known. However, no method exists that can recover the original weak signals hidden in the residual. This work intends to improve on that.

In this paper, we propose the use of normalizing flows [6] to recover the undistorted weak signals in the residual after calibration. Normalizing flows have been used in many data processing applications such as cosmological parameter estimation and model construction [e.g., 7–11] and simulations [e.g., 12–15]. There are many more potential application areas [16, 17] and our work covers one

Figure

FIG. 1. A schematic of the signal flow. The nuisance signals are subtracted from the observed data x\mathbf{x} by calibration to get the residual y\mathbf{y}.

such application. The statistical relationship between the input data and the output residual can be described by using the influence function [1, 18–20]. This relationship enables the closed form calculation of the Jacobian of the mapping between the input and the output residuals. We incorporate this into a normalizing flow model to train the base distribution which enables the determination of the statistics (mainly first order) of the hidden weak signals.

Existing work based on flow models mostly learn the Jacobian (or its inverse) as part of the training process. In contrast, we work with a flow model where the Jacobian of the mapping is externally provided and hence we are not constrained to a bijective mapping. Calibration is a computationally demanding task in data processing and this is performed by specialized and highly optimized software to cope with large data volumes. As a bi-product of calibration, the Jacobian of the mapping from data to residual is also produced. In contrast, common applications of normalizing flows [e.g., contractive residual flows 21] need to learn it themselves. Parameter estimation in (ill-constrained) linear models has some similarity to this work. Prior distributions are trained using flow models in [22] while stochastic differential equa-

tions for structured noise are combined with parameter estimation in [23]. Contrastive flows for signal and background separation (in event classification) are studied in [24] where the background signal is considered a nuisance parameter. A separate flow model for nuisance parameters is trained in [25] for interventional (causal) density estimation. Similarly, in [26], factorized flow models are used to directly estimate the distribution of interest as well as the nuisance parameters. Note that in our method, the nuisance parameters are handled by calibration, without having to train a flow model for computational efficiency. Normalizing flows that flow in both directions (from data to noise and from noise to data) are considered in [27] that uses learnt approximate inverse mappings for heteroscedastic noise modeling in image processing. Flow models with non-invertible Jacobians are considered in [28] where the flow is embedding the data onto a low dimensional manifold.

In this paper, we propose a method that uses a normalizing flow for density estimation where the Jacobian of the forward mapping is explicitly provided. Existing work use normalizing flows for profiling systematic uncertainties in simulation-based inference or act as explicit priors for inverse problems. In this work, we focus on the structural degradation of the signal of interest downstream by calibration. We consider the signal in the traditional sense to be a nuisance (Fig. 1) and the true signal of interest to be hidden in the noise. We do not have the freedom to select the nuisance model (that depends on the physics of the observational setup). The nuisance model is generally considered to be non-linear and non-invertible. A major assumption of our method is that the signal hidden in the noise is weak compared to the nuisance signal and the noise is independent of the nuisance signal. Moreover, we assume statistically stable noise compared to the nuisance signal that may have variations temporally, spatially and spectrally (for example, we can consider the noise to be of cosmological origin while the nuisance to be of Galactic and instrumental origin). Under these assumptions (that are reasonable for experiments measuring signals of cosmological origin), we illustrate a method to recover the weak signals hidden in the noise in this paper. The remainder of this paper is organized as follows: in section II, we provide a theoretical overview of calibration and the statistical relationship between the input and the output residual. In section III, we provide an overview of normalizing flows and the setup we use to train the flow model. Next in section IV, we provide results using a linear regression example as well as using a non-linear example (radio interferometric calibration) before drawing our conclusions in section V.

Notation: Lowercase bold letters refer to column vectors (e.g., y\mathbf{y}). Uppercase bold letters refer to matrices (e.g., C\mathbf{C}). Unless otherwise stated, all variables are real numbers. The set of complex numbers is given as C\mathbb{C} and the set of real numbers is given as R\mathbb{R}. The matrix inverse, pseudo-inverse, transpose, and Hermitian transpose are

referred to as (⋅)−1,(⋅)†,(⋅)T(\cdot)^{-1}, (\cdot)^{\dagger}, (\cdot)^{T}, and (⋅)H(\cdot)^{H}, respectively. The matrix Kronecker product is given by ⊗\otimes. The identity matrix is given by I\mathbf{I} (size depends on the context). The Frobenius norm (for a matrix) or the L-2 norm (for a vector) is given by ∥⋅∥\|\cdot\| and the L-1 norm is given by ∥⋅∥1\|\cdot\|_{1}. The vectorization of a matrix is represented by vec(⋅)\mathrm{vec}(\cdot).