Manuscript Offprint
arXiv:2609.06419Separating Capability from Confidence: Grounded Dual-State Calibration for GRPO-Trained Medical Vision-Language Models
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Abstract
Medical vision-language models (VLMs) require confidence that reflects both answer correctness and patient-specific visual evidence. Recent GRPO-based methods optimize verbalized confidence together with answer generation. However, this joint optimization may interfere with answer learning and drive confidence toward near-binary values. Verbalized confidence also provides no explicit assessment of visual support. We therefore separate capability learning from confidence estimation and propose DualRead. DualRead builds on the insight that reliability can be read from the actor's internal states at critical moments in the answering process. It freezes the GRPO-trained actor and combines pre-answer solvability with a post-answer assessment of the generated answer and its visual support. To further assess whether confidence reflects visual grounding, we introduce Counterfactual Confidence Grounding AUC (CCG-AUC). It measures whether confidence decreases when real-image substitution changes the actor from correct to incorrect. Across two VLM backbones and both in- and out-of-distribution medical VQA benchmarks, DualRead improves correctness discrimination and calibration over verbalized confidence while preserving answer accuracy. CCG-AUC reveals whether confidence responds to answer-relevant visual evidence rather than primarily to non-visual cues.
Introduction
Large vision-language models (VLMs) show growing potential for medical visual question answering and clinical decision support. Yet even capable models make errors, and safe deployment requires identifying unreliable answers before they affect clinical decisions. Reliable confidence enables such a selective workflow: high-confidence cases can be handled automatically, while uncertain cases are deferred to clinicians (Geifman and El-Yaniv 2017). This requires confidence to reflect the model's actual probability of correctness—a property that remains elusive in medical VQA, where overconfidence persists across model families and scales (Byun et al. 2026).
A further requirement for medical VLMs is visual grounding. Clinical judgments rely on patient-specific evidence, whereas VLMs may produce correct or highly confident answers primarily from learned linguistic priors rather than the visual input. Reliable confidence should therefore indicate whether an answer is supported by evidence in the input image.

Figure 1: Motivation of DualRead. Reward-shaped GRPO calibration jointly optimizes answer correctness and verbalized confidence, potentially causing confidence collapse (top). DualRead instead keeps the RLVR actor frozen and estimates reliability along the same natural generation trajectory (bottom), preserving the answer policy while producing confidence that better tracks empirical accuracy.
Reinforcement learning from verifiable rewards (RLVR), particularly GRPO, has become an effective post-training paradigm for improving VLM answer capability. Recent efforts introduce verbalized confidence into the GRPO framework, aiming to improve answer correctness and confidence calibration jointly (Ma et al. 2026). However, the model output space is an imperfect interface for correctness confidence. A verbalized score such as “90% confident” is another autoregressive action, affected by prompt wording, output format, and reward design. Optimizing this score jointly with the answer may interfere with correctness learning. Moreover, directly rewarding the score can polarize its distribution toward near-binary values (Figure 1). These limitations motivate separating capability learning from confidence estimation.
We realize this separation with DualRead. The actor is trained only for answer capability with GRPO and is frozen after training. For confidence estimation, rather than asking the actor to report its own confidence, DualRead infers confidence by observing the internal states. Specifically, the actor first produces its natural response. The input and generated response are then replayed under teacher forcing in order to extract the required hidden states. DualRead focuses on two special times in this trajectory: immediately before response generation and after the answer is complete. The pre-answer solvability read (PSR) uses the pre-answer state to estimate whether the actor can solve the input. The post-answer evidence read (PER) reads the completed-answer state and incorporates visual evidence conditioned on the generated answer to assess whether the answer is supported by the image. The logits estimated by PSR and PER are calibrated separately and combined through dual-state fusion to obtain the final confidence probability. In this way, DualRead separates confidence estimation from capability learning while replacing subjective self-reporting with a state-based estimate.
To assess whether confidence is grounded in visual evidence, we introduce Counterfactual Confidence Grounding AUC (CCG-AUC). For each question, the original image is replaced with a real hard negative that has a different reference answer. We focus on cases where the actor's answer changes from correct to incorrect after image replacement. CCG-AUC then evaluates whether confidence decreases accordingly by comparing the original image with its hard negative. This construction keeps the counterfactual inputs in distribution by using only real images. Fixing the question, actor, and decoding rule further isolates the effect of visual evidence on confidence. The metric is also scale-free and supports direct comparison across confidence interfaces on the same actor.
RLVR and calibration under policy optimization. RLVR with GRPO (Shao et al. 2024; Guo et al. 2025) improves reasoning via outcome-verifiable rewards, but offers no supervision for deployment-time confidence—and RL post-training is known to harm calibration (Damani et al. 2026; Ma et al. 2026). Recent calibration-aware variants incorporate confidence into the policy objective: RLCR adds a proper scoring rule (Damani et al. 2026), DCPO decouples confidence from reasoning gradients (Ma et al. 2026), and multimodal extensions include ranking-aware calibration (Cui, Yang, and Zhu 2026) and VL-Calibration (Xiao, Xu, and Gan 2026). Yet all express confidence through the generated token stream of a jointly optimized policy—the same output interface that suffers from prompt sensi-
tivity and format artifacts. Beyond RL, confidence elicitation spans verbalized uncertainty (Lin, Hilton, and Evans 2022; Tian et al. 2023; Xiong et al. 2024), self-evaluation (Kadavath et al. 2022), self-consistency (Wang et al. 2023), semantic uncertainty (Kuhn, Gal, and Farquhar 2023), and hidden-state probes such as SAPLMA (Azaria and Mitchell 2023)—all of which, whether verbalized or probed, still operate through the output interface and are trained to predict correctness directly. What is missing, therefore, is a confidence estimator that is fully decoupled from the policy optimization that produces the answer, that reads internal states at semantically principled points along the generation trajectory rather than treating a single final state as a correctness classifier, and that explicitly accounts for whether the answer is visually grounded—not just whether it happens to be correct.
Evaluating visual grounding. That VQA models can answer from language priors while ignoring the image is well documented (Goyal et al. 2017; Agrawal et al. 2018; Geirhos et al. 2020), motivating counterfactual and contrastive constructions for training and evaluation (Chen et al. 2023; Gokhale et al. 2020; Wu et al. 2022; Gardner et al. 2020). In the medical domain, Zafar et al. (2026) measure answer-side visual reliance with counterfactual images, and Khanmohammadi et al. (2026) rank confidence against blind (image-free) inputs. Existing protocols, however, target the answer or rely on absent or corrupted images, which confounds grounding with novelty detection. CCG-AUC extends counterfactual evaluation to the confidence score itself, using real in-distribution hard negatives and restricting to cases where the image decisively determines correctness. The two repairs are also complementary: Zafar et al. (2026) improve grounding by retraining the actor with a hard-negative contrastive objective, which changes its answers, whereas DualRead leaves the actor and its answers exactly unchanged and repairs only the confidence gap.
DualRead Confidence Calibration
Let , , and denote a medical image, its associated question, and the reference answer. We train an actor with RLVR using GRPO (Shao et al. 2024). For each input , the actor samples a group of responses . Each response receives a verifiable reward based on answer correctness and output format. GRPO derives group-relative advantages from these rewards and optimizes a clipped policy objective, increasing the likelihood of responses that perform better within the group. This produces the trained actor .
The resulting actor improves answer generation, while the correctness probability of each generated response remains unspecified. For a response , DualRead produces a confidence probability that estimates its likelihood of being correct. A calibrated estimate should satisfy , where indicates whether matches the reference answer. Our central design choice is to learn this confidence outside policy optimization. Accordingly, we freeze the GRPO-trained actor and fit a sepa-

(a) DualRead Confidence Calibration
(b) Counterfactual Confidence Grounding Metric
Figure 2: Overview of our framework. (a) DualRead estimates confidence from pre- and post-answer states of a frozen GRPO-trained VLM. (b) CCG-AUC evaluates confidence grounding using real and hard-negative image pairs sharing the same question.
rate confidence proxy to its internal states. Reliability supervision updates only the confidence proxy, with , leaving the actor and its answer policy unchanged.
Natural-response Replay
For each training example, the frozen actor first produces its natural response . We parse this response and assign the realized-correctness label , which provides supervision for the confidence proxies. The original input and the natural response are then fed back into the frozen actor for a teacher-forced replay, allowing us to revisit the internal states. During replay, DualRead extracts final-layer hidden states at two stages: the state immediately before response generation and the states that provide a retrospective view after the answer is complete.
Dual-state Confidence Proxies
DualRead instantiated the two replay views as complementary confidence proxies (Figure 2). The pre-answer solvability read estimates whether the input is solvable by the current actor before any response token is produced. The post-answer evidence read evaluates the particular answer that the actor actually committed to.
Pre-Answer Solvability Read (PSR). Let denote the sequence of -dimensional hidden states produced by the final layer of the frozen actor during replay. PSR extracts the state at the last non-padding prompt position, immediately before the first response token:
, where indexes this position. By causal masking, can access only the input image and question . The state is therefore independent of the wording, length, and fluency of the realized response, and captures the actor's internal representation immediately before answering. A lightweight MLP, termed the PSR proxy, maps this state to a correctness logit, . We train it using with class-weighted binary cross-entropy. The proxy thus models the actor-specific relationship between its pre-answer state and the correctness of its subsequent response. PSR is optimized independently and remains fixed when fitting PER.
Post-Answer Evidence Read (PER). Complementary to PSR, PER operates after the answer is complete. It contains two components: one reads the actor's post-answer state, while the other evaluates the answer against the visual evidence.
-
Answer commitment state (P-State). For the post-answer state, we extract the final-layer hidden state at the closing position of answer tokens: . This position summarizes the image, question, generated reasoning, and complete response, providing a retrospective read after the answer has been formed. P-State applies a linear confidence proxy to obtain the post-answer logit, .
-
Answer-conditioned visual evidence (P-Visual). P-Visual first extracts answer and image states, then applies answer-conditioned visual pooling to summarize the image evidence relevant to the generated answer. We denote the token positions that form the answer by and summarize its content by averaging their final-layer states,
Let be the final-layer states at the image-token positions. Their global mean is
We obtain the answer-conditioned evidence state through cosine-similarity pooling:
where is a fixed pooling temperature. This parameter-free operation summarizes image-token states that are representationally aligned with the answer. We form the visual interaction block:
The interaction block is passed through the P-Visual confidence proxy and connected residually to the answer-state logit. The final post-answer logit is
The proxies and are trained sequentially using with binary cross-entropy and regularization. P-State is fitted first and then frozen while P-Visual learns the residual correction. We exclude decoder likelihood and entropy, as these signals are more closely tied to the fluency and local predictability of the output trajectory than to its visual support.
Calibration and Dual-State Fusion
PSR and PER produce logits at different stages of the response and may operate at different confidence scales. We calibrate them separately using temperature scaling, yielding
where each scalar temperature is selected by minimizing binary cross-entropy while the actor and confidence proxies remain fixed. DualRead then combines the calibrated pre- and post-answer confidence using an equal-weight average in log-odds space:
The resulting is the final confidence estimate for . No parameters are learned during fusion, and the actor and its generated answer remain unchanged.
Counterfactual Confidence Grounding Metric
Calibration alone does not show whether confidence responds to the image. A confidence estimate may reflect question difficulty or language priors without tracking the visual evidence relevant to the answer. We therefore introduce Counterfactual Confidence Grounding AUC (CCG-AUC), which measures whether confidence decreases when answer-relevant visual evidence is replaced.
The counterfactual should remain within the data distribution. Blanking or removing the image creates an artificial input and provides no valid counterfactual answer. Instead, we replace the original image with a real image paired with the same question but a different reference answer. This produces an in-distribution counterfactual in which the image is relevant to the expected answer.
For each item , we select a real hard-negative image associated with the same question and a different reference answer. Items with a valid pairing form the eligible set . Using the same frozen actor and decoding rule, we generate an answer for both and . This yields correctness labels and , evaluated with their respective reference answers, and confidence estimates and . We focus on the decisive set
where image replacement changes the actor from correct to incorrect. Define . CCG-AUC is then
The metric assigns 1 when confidence is higher for the original image, 0 when it is higher for the hard negative, and 0.5 for a tie. Thus, 0.5 indicates no directional response, while 1.0 indicates that confidence always decreases after decisive image replacement. It does not measure pixel-level localization or rationale faithfulness.
We refer to Eq. (10) as Natural CCG-AUC, since the actor generates its response naturally for each image and may therefore change its answer after image replacement. To control for answer changes, let and denote the canonical actor answers. We define the strict decisive set as
Strict CCG-AUC applies Eq. (10) over . It therefore evaluates whether confidence responds to image evidence while holding the canonical answer fixed.
Experiments and Results
Datasets and Evaluation Metrics
We evaluate all methods on SLAKE-test (Liu et al. 2021) with 1,061 questions as the in-distribution benchmark. To assess out-of-distribution generalization, we use six medical VQA datasets: VQA-RAD (Lau et al. 2018) with 600 questions, PathVQA (He et al. 2020) with 1,000 questions, PMC-VQA (Zhang et al. 2024) with 1,000 questions, OmniMed-VQA (Hu et al. 2024) with 920 questions, ReXVQA (Pal et al. 2026) with 1,000 questions, and the closed-answer subset of VQA-Med 2019 (Ben Abacha et al. 2019) with 64 questions, yielding 4,584 OOD examples in total. No OOD examples are used to fit the actors, confidence readers, or calibration temperatures. For the OOD summary, each metric is first computed independently on each domain and then macro-averaged across the six domains, preventing datasets with more examples from dominating the result. We report answer accuracy (Acc.) and the area under the receiver operating characteristic curve (AUROC) for correctness discrimination. Natural CCG-AUC and Strict CCG-AUC are also reported. The ablation and cost analyses add Brier and the tie-aware area under the risk-coverage curve (AURC). All post-hoc confidence proxy use the same frozen RLVR actor and therefore share its answer accuracy while differing only in their confidence estimates. Please refer to the supplementary material for other detailed calibration metrics including ECE and Brier.
Implementation Details
We instantiated the capability actor using Qwen3-VL-2B-Instruct (Qwen Team 2025) and MedGemma1.5-4B (Sellergren et al. 2026) and fully post-trained each backbone on SLAKE-train with GRPO. GRPO used a group size of 8, the AdamW optimizer with a learning rate of , a global batch size of 128, and three passes over the training set. Except for the pretrained Base models, all methods were evaluated over three random seeds. For a fair comparison, all policy baselines shared the same training data, prompts, grader, and optimization protocol, while all hidden-state baselines used the same frozen RLVR actor and its greedily generated answers. For the sampling-based baselines, SC@K measures agreement among K stochastic completions, while semantic uncertainty clusters the same eight completions by canonical answer.
DualRead extracted the pre-answer and post-answer representations through one teacher-forced replay, with the cosine-similarity pooling temperature fixed to throughout all experiments. The post-answer linear heads were fitted sequentially for 1,000 steps using binary cross-entropy with a learning rate of , while the PSR head used an MLP with two hidden layers of 256 and 128 units and early stopping. Reader fitting and temperature scaling used image-disjoint partitions of SLAKE-train without target-domain adaptation. The calibrated branches were fused using a fixed equal-weight mean in log-odds space. All experiments were performed on a single node with 8 NVIDIA H200 GPUs (141 GB each) under Ubuntu 22.04.5 LTS, using PyTorch 2.8.0 with CUDA 12.8.
Results
Table 1 compares DualRead with three families of confidence proxy on Qwen3VL-2B and MedGemma1.5-4B of verbalized-token methods, prompted self-checking methods, and hidden-state probes. Base, RLCR, DCPO, and VL-Calibration use different actor outputs. In contrast, GRPO (RLVR), P(True), self-probing, prompt ensemble, SAPLMA, BICR, and DualRead are evaluated on exactly the same frozen RLVR actor outputs and therefore share the same accuracy. This design isolates confidence estimation from changes in answer generation.
Although RLVR achieves competitive answer accuracy, its verbalized confidence remains weakly aligned with correctness. Prompted self-checking provides only limited improvements, whereas hidden-state methods perform substantially better. DualRead achieves the best ID AUROC and Natural CCG AUC on both backbones, as well as the best Strict CCG AUC on Qwen3VL-2B, demonstrating that its confidence is both reliable and grounded in the relevant visual evidence.
The OOD results further demonstrate the generalizability of DualRead. Without changing the actor predictions, DualRead consistently improves AUROC and both CCG metrics over the confidence verbalized by RLVR. It achieves the strongest OOD grounding performance on MedGemma1.5-4B and remains competitive on Qwen3VL-2B. SAPLMA and BICR perform better on several individual OOD metrics, suggesting that cross-domain confidence estimation remains dependent on the backbone and confidence proxy. Overall, DualRead provides the most consistent improvement in confidence reliability and grounding while fully preserving the accuracy of the underlying RLVR actor.
Ablation study.. To assess the contribution of each component, we conduct an ablation study, as shown in Table 2. Both PSR and P-State provide competitive confidence estimates, indicating that useful correctness information exists both before and after answer generation. Incorporating the visual residual into P-State consistently improves discrimination, calibration, and confidence grounding, demonstrating the importance of answer-conditioned visual evidence. Combining PSR and PER in DualRead further achieves the highest AUROC and lowest Brier score on both backbones, together with the best CCG-AUC on Qwen3VL-2B. Although PER slightly outperforms DualRead in CCG-AUC on MedGemma1.5-4B, DualRead remains superior in overall reliability. These results demonstrate that the pre-answer and post-answer branches capture complementary confidence information.
Deeper Analysis and Discussions
Policy optimization compresses verbalized confidence.. Figure 3 reveals a distinction that is not fully captured by aggregate metrics. The confidence scores produced by the Base model are broadly distributed but poorly calibrated, whereas RLVR concentrates most predictions near the maximum-confidence endpoint. Calibration-aware policy optimization partially changes this distribution, but its
Table 1: Reliability and confidence-grounding results on SLAKE and six OOD medical VQA datasets. OOD Acc./AUROC are equal-domain averages over all six datasets. Confidence proxies from GRPO (RLVR) to DualRead share the same frozen actor and thus identical Acc. Gray and blue denote Base and DualRead, respectively; bold indicates the best non-Acc. result.
| Confidence proxy | Baseline | SLAKE-test (n=1061) | O.O.D. Averaged (n=4584) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Acc. | AUROC | Natural CCG AUC | Strict CCG AUC | Acc. | AUROC | Natural CCG AUC | Strict CCG AUC | |||
| Qwen3VL-2B | Verbalized token | Base | .443 | .579 | .587 | .423 | .450 | .696 | .782 | .622 |
| RLCR | .608±.009 | .822±.014 | .533±.031 | .514±.036 | .492±.012 | .613±.008 | .516±.022 | .509±.028 | ||
| DCPO | .640±.003 | .789±.007 | .554±.021 | .540±.022 | .491±.004 | .622±.005 | .505±.018 | .509±.011 | ||
| VL-Cal. | .591±.010 | .756±.026 | .553±.016 | .500±.034 | .497±.010 | .633±.020 | .566±.045 | .559±.042 | ||
| Prompted self-check | GRPO(RLVR) | .535±.059 | .516±.031 | .507±.018 | .507±.008 | .529±.051 | .516±.027 | |||
| P(True) | .609±.012 | .580±.038 | .533±.052 | .555±.010 | .514±.101 | .412±.101 | ||||
| Self-prob. | .639±.009 | .517±.033 | .532±.050 | .518±.032 | .494±.004 | .508±.028 | .491±.056 | .442±.103 | ||
| Hidden state | Prompt ensemble | .534±.034 | .524±.078 | .488±.051 | .519±.019 | .518±.057 | .453±.072 | |||
| SAPLMA | .942±.004 | .715±.044 | .693±.068 | .697±.006 | .550±.145 | .484±.199 | ||||
| BICR | .934±.002 | .723±.039 | .705±.050 | .644±.005 | .530±.026 | .597±.029 | ||||
| DualRead | .952±.004 | .784±.009 | .738±.039 | .666±.021 | .624±.067 | .561±.099 | ||||
| MedGemma1.5-4B | Verbalized token | Base | .478 | .615 | .535 | .542 | .494 | .590 | .502 | .375 |
| RLCR | .657±.027 | .771±.021 | .527±.020 | .507±.020 | .576±.001 | .601±.025 | .519±.004 | .495±.008 | ||
| DCPO | .678±.003 | .752±.018 | .509±.025 | .519±.033 | .561±.021 | .621±.013 | .568±.012 | .557±.016 | ||
| VL-Cal. | .587±.005 | .851±.005 | .608±.039 | .580±.019 | .560±.005 | .661±.025 | .598±.043 | .554±.027 | ||
| Prompted self-check | GRPO(RLVR) | .506±.011 | .503±.005 | .504±.007 | .502±.003 | .504±.006 | .506±.011 | |||
| P(True) | .574±.026 | .634±.054 | .678±.060 | .594±.015 | .538±.082 | .475±.161 | ||||
| Self-prob. | .677±.011 | .597±.110 | .557±.050 | .561±.046 | .586±.005 | .527±.045 | .558±.055 | .571±.061 | ||
| Hidden state | Prompt ensemble | .626±.073 | .548±.070 | .550±.099 | .537±.031 | .539±.075 | .512±.097 | |||
| SAPLMA | .942±.011 | .814±.063 | .767±.080 | .687±.018 | .550±.143 | .636±.174 | ||||
| BICR | .930±.007 | .801±.023 | .804±.040 | .635±.022 | .630±.053 | .644±.108 | ||||
| DualRead | .947±.005 | .819±.030 | .786±.033 | .647±.034 | .634±.162 | .683±.088 | ||||
Table 2: Component ablation of DualRead. PER combines P-State and P-Visual; DualRead further combines PER with PSR. CCG-AUC here is the Natural variant on SLAKE-test.
| Variant | Components | AUROC↑ | Brier↓ | CCG-AUC↑ | ||
|---|---|---|---|---|---|---|
| PSR State Visual | ||||||
| Qwen3VL-2B | ||||||
| PSR | ✓ | ✗ | ✗ | .926±.008 | .101±.005 | .733±.044 |
| P-State | ✗ | ✓ | ✗ | .928±.006 | .099±.007 | .686±.027 |
| PER | ✗ | ✓ | ✓ | .947±.003 | .084±.001 | .760±.038 |
| DualRead | ✓ | ✓ | ✓ | .952±.004 | .081±.004 | .784±.009 |
| MedGemma1.5-4B | ||||||
| PSR | ✓ | ✗ | ✗ | .914±.009 | .105±.007 | .725±.053 |
| P-State | ✗ | ✓ | ✗ | .934±.002 | .086±.003 | .769±.050 |
| PER | ✗ | ✓ | ✓ | .945±.006 | .079±.005 | .825±.040 |
| DualRead | ✓ | ✓ | ✓ | .947±.005 | .076±.004 | .819±.030 |
verbalized scores remain highly concentrated or nearly binary, limiting their ability to rank intermediate-risk cases. In contrast, DualRead produces a continuous confidence distribution that more closely follows the empirical accuracy curve. This result suggests that RLVR does not necessarily remove correctness-related information from the model; rather, policy optimization compresses the interface through

Figure 3: Reliability diagrams on SLAKE-test. The dashed diagonal denotes perfect calibration.
which this information is verbalized. Reading confidence from the frozen internal states therefore recovers useful resolution without modifying the actor or its answers.
DualRead responds to visual evidence.. The counterfactual examples in Figure 4 illustrate the difference between verbalized confidence and hidden-state confidence. When the original image is replaced by a same-question hard neg-

Figure 4: Qualitative examples of counterfactual confidence grounding. Natural CCG allows the answer to change after same-question image replacement, whereas Strict CCG retains the answer while flipping its correctness.
Table 3: Compute-reliability trade-off. is the required greedy generation, one prompt-only view, and Dual-Read's natural-trajectory replay. Lower AURC means better selective-prediction risk at matched coverage.
| Methods | Cost | AUROC↑ | Brier↓ | AURC↓ |
|---|---|---|---|---|
| Qwen3VL-2B, ID: SLAKE-test | ||||
| SC@2 | 2t | 0.742±.006 | 0.165±.002 | 0.234±.005 |
| SC@8 | 8t | 0.831±.003 | 0.140±.003 | 0.179±.006 |
| Semantic unc. | 8t | 0.831±.002 | 0.135±.001 | 0.179±.007 |
| BICR | t+2ρ | 0.934±.002 | 0.099±.003 | 0.101±.004 |
| DualRead | t+τ | 0.952±.004 | 0.083±.002 | 0.094±.003 |
| Qwen3VL-2B, OOD: VQA-RAD | ||||
| SC@2 | 2t | 0.699±.011 | 0.226±.007 | 0.428±.009 |
| SC@8 | 8t | 0.765±.016 | 0.207±.010 | 0.379±.007 |
| Semantic unc. | 8t | 0.766±.017 | 0.205±.011 | 0.380±.009 |
| BICR | t+2ρ | 0.686±.019 | 0.266±.020 | 0.413±.011 |
| DualRead | t+τ | 0.728±.010 | 0.234±.006 | 0.387±.009 |
| MedGemma1.5-4B, ID: SLAKE-test | ||||
| SC@2 | 2t | 0.659±.034 | 0.181±.010 | 0.248±.007 |
| SC@8 | 8t | 0.740±.040 | 0.165±.013 | 0.205±.012 |
| Semantic unc. | 8t | 0.740±.040 | 0.161±.014 | 0.205±.012 |
| BICR | t+2ρ | 0.930±.007 | 0.100±.007 | 0.084±.006 |
| DualRead | t+τ | 0.947±.005 | 0.082±.002 | 0.079±.005 |
| MedGemma1.5-4B, OOD: VQA-RAD | ||||
| SC@2 | 2t | 0.678±.011 | 0.232±.007 | 0.399±.019 |
| SC@8 | 8t | 0.739±.009 | 0.218±.005 | 0.354±.010 |
| Semantic unc. | 8t | 0.746±.005 | 0.209±.003 | 0.352±.010 |
| BICR | t+2ρ | 0.723±.002 | 0.288±.023 | 0.358±.008 |
| DualRead | t+τ | 0.756±.016 | 0.217±.017 | 0.331±.006 |
ative, the actor may retain the same answer and report the same near-maximum verbalized confidence even though the answer becomes incorrect. DualRead instead assigns substantially lower confidence to the replaced image. Because
the question and canonical answer remain unchanged, the confidence difference cannot be explained solely by question difficulty or answer wording. These examples provide an intuitive view of the behavior measured by Strict CCG-AUC: confidence decreases when the visual evidence supporting an otherwise identical answer is removed. The examples are illustrative rather than standalone evidence and should be interpreted together with the aggregate CCG-AUC results.
DualRead provides an efficient compute-reliability trade-off. Table 3 further compares DualRead with repeated-sampling and counterfactual-view baselines under their corresponding inference costs. DualRead achieves a favorable reliability-compute trade-off on the in-domain setting without requiring multiple full generations. Under distribution shift, repeated sampling remains competitive on some metrics, whereas DualRead provides consistently strong reliability with substantially lower additional inference. These results indicate that the benefit of DualRead arises from extracting complementary evidence along the natural trajectory rather than merely increasing the number of model queries.
Conclusion
Reliable confidence can be obtained from hidden state, rather than generated by a GRPO-trained medical VLM. DualRead freezes the actor and fuses PSR with PER, improving discrimination, calibration, and selective prediction without changing its answers. Under same-question hard negatives, the resulting confidence responds to decisive visual evidence while the same actor's verbalized token does not, consistently across both backbones. Our evidence is limited to short-answer medical VQA on 2-4B models; larger models, report generation, and non-uniform open/closed behavior re-main open. Future work should test state-based training signals without recreating token-interface collapse and extend the counterfactual protocol to entity-level claims in clinical reports.
References
Agrawal, A.; Batra, D.; Parikh, D.; and Kembhavi, A. 2018. Don't Just Assume; Look and Answer: Overcoming Priors for Visual Question Answering. In IEEE Conference on Computer Vision and Pattern Recognition (CVPR).
Azaria, A.; and Mitchell, T. 2023. The Internal State of an LLM Knows When It's Lying. In Findings of the Association for Computational Linguistics: EMNLP 2023, 967–976. Association for Computational Linguistics.
Ben Abacha, A.; Hasan, S. A.; Datla, V. V.; Liu, J.; Demner-Fushman, D.; and Müller, H. 2019. VQA-Med: Overview of the Medical Visual Question Answering Task at Image-CLEF 2019. In Working Notes of CLEF 2019—Conference and Labs of the Evaluation Forum, volume 2380 of CEUR Workshop Proceedings. CEUR-WS.org.
Byun, J. Y.; Park, Y.-J.; Corbeil, J.-P.; and Ben Abacha, A. 2026. Overconfidence and Calibration in Medical VQA: Empirical Findings and Hallucination-Aware Mitigation. arXiv preprint arXiv:2604.02543.
Chen, L.; Zheng, Y.; Niu, Y.; Zhang, H.; and Xiao, J. 2023. Counterfactual Samples Synthesizing and Training for Robust Visual Question Answering. IEEE Transactions on Pattern Analysis and Machine Intelligence, 45(11): 13218–13234.
Cui, P.; Yang, B.; and Zhu, J. 2026. Ranking-Aware Calibration for Reliable Multimodal Reinforcement Learning. arXiv preprint arXiv:2605.16999.
Damani, M.; Puri, I.; Slocum, S.; Shenfeld, I.; Choshen, L.; Kim, Y.; and Andreas, J. 2026. Beyond Binary Rewards: Training LMs to Reason About Their Uncertainty. In International Conference on Learning Representations (ICLR).
Gardner, M.; Artzi, Y.; Basmov, V.; Berant, J.; Bogin, B.; Chen, S.; Dasigi, P.; Dua, D.; Elazar, Y.; Gottumukkala, A.; Gupta, N.; Hajishirzi, H.; Ilharco, G.; Khashabi, D.; Lin, K.; Liu, J.; Liu, N. F.; Mulcaire, P.; Ning, Q.; Singh, S.; Smith, N. A.; Subramanian, S.; Tsarfaty, R.; Wallace, E.; Zhang, A.; and Zhou, B. 2020. Evaluating Models' Local Decision Boundaries via Contrast Sets. In Findings of the Association for Computational Linguistics: EMNLP.
Geifman, Y.; and El-Yaniv, R. 2017. Selective Classification for Deep Neural Networks. In Advances in Neural Information Processing Systems (NeurIPS).
Geirhos, R.; Jacobsen, J.-H.; Michaelis, C.; Zemel, R.; Brendel, W.; Bethge, M.; and Wichmann, F. A. 2020. Shortcut Learning in Deep Neural Networks. Nature Machine Intelligence, 2(11): 665–673.
Gokhale, T.; Banerjee, P.; Baral, C.; and Yang, Y. 2020. MUTANT: A Training Paradigm for Out-of-Distribution Generalization in Visual Question Answering. In Proceedings of the 2020 Conference on Empirical Methods in Natural Language Processing (EMNLP), 878–892.
Goyal, Y.; Khot, T.; Summers-Stay, D.; Batra, D.; and Parikh, D. 2017. Making the V in VQA Matter: Elevating the Role of Image Understanding in Visual Question Answering. In IEEE Conference on Computer Vision and Pattern Recognition (CVPR).
Guo, D.; Yang, D.; Zhang, H.; Song, J.; Zhang, R.; Xu, R.; Zhu, Q.; Ma, S.; Wang, P.; Bi, X.; et al. 2025. DeepSeek-R1 Incentivizes Reasoning in LLMs through Reinforcement Learning. Nature, 645(8081): 633–638.
He, X.; Zhang, Y.; Mou, L.; Xing, E.; and Xie, P. 2020. PathVQA: 30000+ Questions for Medical Visual Question Answering. arXiv preprint arXiv:2003.10286.
Hu, Y.; Li, T.; Lu, Q.; Shao, W.; He, J.; Qiao, Y.; and Luo, P. 2024. OmniMedVQA: A New Large-Scale Comprehensive Evaluation Benchmark for Medical LVLM. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 22170–22183.
Kadavath, S.; Conerly, T.; Askell, A.; Henighan, T.; Drain, D.; Perez, E.; Schiefer, N.; Hatfield-Dodds, Z.; DasSarma, N.; Tran-Johnson, E.; et al. 2022. Language Models (Mostly) Know What They Know. arXiv preprint arXiv:2207.05221.
Khanmohammadi, R.; Miahí, E.; Kaur, S.; Smiley, C. H.; Brugere, I.; Thind, K.; and Ghassemi, M. M. 2026. Grounded or Guessing? LVLM Confidence Estimation via Blind-Image Contrastive Ranking. arXiv preprint arXiv:2605.10893.
Kuhn, L.; Gal, Y.; and Farquhar, S. 2023. Semantic Uncertainty: Linguistic Invariances for Uncertainty Estimation in Natural Language Generation. In International Conference on Learning Representations (ICLR).
Lau, J. J.; Gayen, S.; Ben Abacha, A.; and Demner-Fushman, D. 2018. A dataset of clinically generated visual questions and answers about radiology images. Scientific Data, 5(1): 180251.
Li, C.; Wong, C.; Zhang, S.; Usuyama, N.; Liu, H.; Yang, J.; Naumann, T.; Poon, H.; and Gao, J. 2023. LLaVA-Med: Training a Large Language-and-Vision Assistant for Biomedicine in One Day. In Advances in Neural Information Processing Systems (NeurIPS).
Lin, S.; Hilton, J.; and Evans, O. 2022. Teaching Models to Express Their Uncertainty in Words. Transactions on Machine Learning Research (TMLR).
Liu, B.; Zhan, L.-M.; Xu, L.; Ma, L.; Yang, Y.; and Wu, X.-M. 2021. SLAKE: A Semantically-Labeled Knowledge-Enhanced Dataset for Medical Visual Question Answering.
In 2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI), 1650–1654.
Ma, Z.; Wen, X.; Cao, B.; Lu, Y.; Lin, H.; Yang, J.; He, M.; Han, X.; and Sun, L. 2026. Decoupling Reasoning and Confidence: Resurrecting Calibration in Reinforcement Learning from Verifiable Rewards. arXiv preprint arXiv:2603.09117.
Pal, A.; Lee, J.-O.; Zhang, X.; Sankarasubbu, M.; Roh, S.; Kim, W. J.; Lee, M.; and Rajpurkar, P. 2026. ReXVQA: A Large-scale Visual Question Answering Benchmark for Generalist Chest X-ray Understanding. In Pacific Symposium on Biocomputing 2026, volume 31, 251–264.
Qwen Team. 2025. Qwen3 Technical Report. arXiv preprint arXiv:2505.09388.
Sellergren, A.; Gao, C.; Mahvar, F.; Kohlberger, T.; Jamil, F.; Traverse, M.; Tono, A.; Sadjad, B.; Yang, L.; Lau, C.; et al. 2026. MedGemma 1.5 Technical Report. arXiv preprint arXiv:2604.05081.
Senoglu, E.; Toschi, F.; Brunello, N.; Sassella, A.; and Carman, M. J. 2026. Just How Sure Are You? Improving Verbalized Uncertainty Calibration in Medical VQA. arXiv preprint arXiv:2606.27023.
Shao, Z.; Wang, P.; Zhu, Q.; Xu, R.; Song, J.; Bi, X.; Zhang, H.; Zhang, M.; Li, Y. K.; Wu, Y.; and Guo, D. 2024. DeepSeekMath: Pushing the Limits of Mathematical Reasoning in Open Language Models. arXiv preprint arXiv:2402.03300.
Tian, K.; Mitchell, E.; Zhou, A.; Sharma, A.; Rafailov, R.; Yao, H.; Finn, C.; and Manning, C. D. 2023. Just Ask for Calibration: Strategies for Eliciting Calibrated Confidence Scores from Language Models Fine-Tuned with Human Feedback. In Conference on Empirical Methods in Natural Language Processing (EMNLP).
Wang, X.; Wei, J.; Schuurmans, D.; Le, Q.; Chi, E.; Narang, S.; Chowdhery, A.; and Zhou, D. 2023. Self-Consistency Improves Chain of Thought Reasoning in Language Models. In International Conference on Learning Representations (ICLR).
Wu, Y.; Zhao, Y.; Zhao, S.; Zhang, Y.; Yuan, X.; Zhao, G.; and Jiang, N. 2022. Overcoming Language Priors in Visual Question Answering via Distinguishing Superficially Similar Instances. In Proceedings of the 29th International Conference on Computational Linguistics (COLING), 5721–5729.
Xiao, W.; Xu, X.; and Gan, L. 2026. VL-Calibration: Decoupled Confidence Calibration for Large Vision-Language Models Reasoning. arXiv preprint arXiv:2604.09529.
Xiong, M.; Hu, Z.; Lu, X.; Li, Y.; Fu, J.; He, J.; and Hooi, B. 2024. Can LLMs Express Their Uncertainty? An Empirical Evaluation of Confidence Elicitation in LLMs. In International Conference on Learning Representations (ICLR).
Zafar, A.; Murali, L. K.; Bharadwaj, S.; Vashist, A.; and Wu, J. 2026. Do Medical Vision Language Models Actually See? A Counterfactual Grounding Framework and Hard-Negative Contrastive Training for Visually-Reliant Medical VLMs. arXiv preprint arXiv:2607.03647.
Zhang, X.; Wu, C.; Zhao, Z.; Lin, W.; Zhang, Y.; Wang, Y.; and Xie, W. 2024. Development of a large-scale medical visual question-answering dataset. Communications Medicine, 4(1): 277.
Zhao, Y.; Zhang, R.; Xiao, J.; Hou, R.; Guo, J.; Zhang, Z.; Hao, Y.; and Chen, Y. 2025. Object-Level Verbalized Confidence Calibration in Vision-Language Models via Semantic Perturbation. arXiv preprint arXiv:2504.14848.
Technical Supplement
This supplement documents the frozen protocol, the exact configurations, and the extended measurements behind the main paper.
A. GRPO Formulation
For each input , the actor samples a group of responses . Each response receives a verifiable task reward
where denotes answer correctness and penalizes malformed responses. GRPO converts these rewards into group-relative advantages,
and applies a clipped policy objective to increase the likelihood of responses that outperform others sampled for the same input, yielding the trained actor .
B. Hyperparameters
Table 4 lists the complete frozen configuration for GRPO actor training, DualRead head fitting, and evaluation.
C. Dataset Details
Table 5 gives the exact partitions consumed by the experiments: SLAKE, VQA-RAD, PathVQA, PMC-VQA, OmniMedVQA, ReXVQA, and VQA-Med 2019. Every split is represented by a frozen manifest with one row per question and an image identifier used for disjoint fitting, subgroup analysis, and clustered resampling.
SLAKE. Each question carries answer_type in {open, closed} and a content family (modality, organ, plane, position, abnormality, size, shape, color, quantity, knowledge). Metrics are recomputed from item-level predictions inside each subgroup rather than derived from the overall value. SLAKE validation is used only for checkpoint/model selection and deployable threshold selection; it never enters a test metric.
VQA-RAD. The frozen 600-question manifest contains 270 images and preserves the short free-form answer contract used by SLAKE. It is used as a zero-touch transport test.
PathVQA. The complete PathVQA test manifest contains 6719 questions. Before model evaluation we drew an answer-type-balanced subset: 500 open and 500 closed questions, at most two questions per image, uniform sampling within answer type, with the corpus mixture otherwise preserved. The resulting set contains 706 unique pathology images and retains the same free-form short-answer output contract as SLAKE/VQA-RAD. Its content-family counts
are 10 modality, 51 position, 429 presence, 4 size, and 506 other questions. The selection rule, IDs, and images are fixed across all methods and seeds.
Option-visible OOD datasets. PMC-VQA, OmniMed-VQA, and ReXVQA use the semantic-answer multiple-choice interface: the actor sees all four options and places the complete selected option text in the answer span. The respective frozen factual manifests contain 1000, 920, and 1000 questions. They are part of the six-domain OOD average in the main paper; shuffled-image variants remain supplementary controls only. Per-domain results are given in Tables 8 and 9.
VQA-Med 2019 closed subset. The de-duplicated VQA-Med 2019 test view contains 496 questions after removing four images duplicated in VQA-RAD. We uses only its frozen 64-question closed subset, selected by question identity before scoring for every method and seed.
D. Evaluation Details
One deterministic correctness grader. Training rewards and all reported labels use the same non-LLM grader. It lowers cases, trims punctuation and whitespace, drops one leading article, applies a guarded singular/plural fold, and maps a small frozen set of equivalences (e.g., xray/radiograph, CT/computed tomography, and yes/no variants). Laterality is never collapsed. A prediction is correct iff its non-empty canonical form exactly matches the canonical gold answer. Empty, duplicated, or unparseable answers score zero. No synonym was added after test/OOD inspection and no LLM judge is used for headline results.
Output and confidence parsing. The shared contract is <reasoning>.../<reasoning><answer>.../<answer> <confidence>NN</confidence>, where NN is one integer in [0, 100]. Exactly one non-empty answer block and one integer confidence block are required. Floats, percentages, out-of-range values, missing tags, or duplicated tags make confidence invalid. Invalid rows are retained and assigned for evaluation; the valid fraction is reported in Table 6. VL-Calibration retains its native vision/reasoning confidence blocks in [0, 10] and uses the method's fixed harmonic aggregation. Base uses normalized logits over the elicited confidence vocabulary, so token parse rate is not applicable. State readers always return a finite scalar and consequently have parse rate one.
Metric definitions. For confidence and correctness , Accuracy is and Brier is . AUROC is the probability that a randomly selected correct item has higher confidence than a randomly selected incorrect item, with a tie contributing 0.5. ECE-15 uses the fixed intervals and computes , skipping empty bins. AURC sorts confidence from high to low; all equal-confidence items form
| GRPO actor training (shared; reward differs per method) | |
|---|---|
| Advantage estimator | GRPO, group size G = 8 |
| Rollout temperature / top-p | 1.0 / 1.0 |
| PPO clip (low / high) | 0.2 / 0.2 |
| KL penalty | disabled (coef = 0) |
| Optimizer | AdamW, lr 1 × 10⁻⁶, β = (0.9, 0.95) |
| LR schedule / warmup | constant, 5% warmup |
| Weight decay / grad-norm clip | 1 × 10⁻² / 1.0 |
| Precision / attention | BF16 / SDPA |
| Trainable params | full model incl. vision tower |
| Prompt batch / global batch | 128 / 128 |
| Max prompt / completion length | 4096 / 256 (Qwen)† |
| Training exposure | 3 passes over SLAKE-train (117 steps) |
| Seeds | {17, 29, 43} |
| Hardware | one node with 8×H200 (141 GB); each run uses 4 GPUs (Qwen) or 2 GPUs (MedGemma) |
| Software | Ubuntu 22.04.5 LTS, PyTorch 2.8.0, CUDA 12.8 |
| Hidden-state head fitting (DualRead) | |
| PSR head (pre-answer) | MLP 256–128, BCE, AdamW lr 1.276 × 10⁻⁴, weight decay 2.017 × 10⁻⁶, batch 32, ≤ 200 epochs, early stopping (patience 20); architecture frozen |
| PER heads (post-answer) | P-State then P-Visual, linear pointwise BCE, 1000 full-batch steps, lr 1 × 10⁻³ |
| L2 (P-State / P-Visual) | 1 × 10⁻⁴ / 1 × 10⁻³ |
| Visual pooling | cosine-similarity pooling, temperature κ = 0.1 |
| Fusion | log-odds mean of calibrated PSR and PER, weight 0.5 (frozen a priori) |
| Calibration | one scalar temperature per branch, fit on held-out SLAKE-train images |
| Evaluation | |
| Decoding | greedy (temperature 0) |
| Invalid-confidence policy | retain, impute c = 0.5, report parse rate |
| Bootstrap | paired image-cluster, B = 10,000, 95% percentile |
Table 4: Frozen hyperparameters. †MedGemma uses a 512-token prompt limit without SLAKE truncation.
| Dataset | Role | QA | Images | Open | Closed |
|---|---|---|---|---|---|
| SLAKE-train | actor/head fit | 4919 | 450 | 2976 | 1943 |
| SLAKE-val. | selection only | 1053 | 96 | 631 | 422 |
| SLAKE-test | ID report | 1061 | 96 | 645 | 416 |
| VQA-RAD | OOD report | 600 | 270 | 236 | 364 |
| PathVQA | OOD report | 1000 | 706 | 500 | 500 |
| PMC-VQA | OOD report | 1000 | 1000 | 994 | 6 |
| OmniMedVQA | OOD report | 920 | 920 | 0 | 920 |
| ReXVQA | OOD report | 1000 | 1000 | 0 | 1000 |
| VQA-Med 2019 (closed) | OOD report | 64 | 64 | 0 | 64 |
Table 5: Frozen dataset inventory; images are unique identifiers for leakage control and clustered resampling.
an indivisible block, and we use the exact expected risk under a uniform random order within that block. HCE@0.9 = is error mass in the entire evaluation set, not conditional error among accepted cases.
Calibration and uncertainty. Reader weights and standardization never see calibration, validation, test, or OOD images. Scalar temperatures are fit by binary cross-entropy on the image-disjoint SLAKE-train calibration partition and then frozen. No temperature is refit on any of the six OOD datasets. Reported uncertainty is the standard deviation over actor seeds {17, 29, 43} as recorded by each frozen experiment artifact; the OOD6 aggregation uses the sample standard deviation. Paired claims additionally resample unique source images with replacement and retain all questions from a sampled image; grounding uses 10,000 percentile-bootstrap replicates.
E. Baseline Implementation Details
Two categories are distinguished throughout: a GRPO baseline and an Estimator baseline. Base, RLVR, RLCR, DCPO, and VL-Calibration have their own generated answers.
(a) Frozen data inventory
| Dataset | Role | QA | Images | Open | Closed |
|---|---|---|---|---|---|
| SLAKE-train | fit | 4919 | 450 | 2976 | 1943 |
| SLAKE-val. | select | 1053 | 96 | 631 | 422 |
| SLAKE-test | ID | 1061 | 96 | 645 | 416 |
| VQA-RAD | OOD | 600 | 270 | 236 | 364 |
| PathVQA | OOD | 1000 | 706 | 500 | 500 |
| PMC-VQA | OOD | 1000 | 1000 | 994 | 6 |
| OmniMedVQA | OOD | 920 | 920 | 0 | 920 |
| ReXVQA | OOD | 1000 | 1000 | 0 | 1000 |
| VQA-Med19-C | OOD | 64 | 64 | 0 | 64 |
(b) Confidence-channel audit
| Backbone | Interface | Parse rate | Support | ||
|---|---|---|---|---|---|
| SLAKE | VQA-RAD | Unique | Endpt. | ||
| Qwen | RLVR token | 1.000 | 1.000 | 2 | 1.000 |
| RLCR token | 1.000 | 1.000 | 2 | 1.000 | |
| BICR / DualRead | 1.000 | 1.000 | 1061 | 0.000 | |
| MedGemma | RLVR token | 1.000 | 1.000 | 1 | 1.000 |
| RLCR token | 1.000 | 1.000 | 2 | 1.000 | |
| BICR / DualRead | 1.000 | 1.000 | 1061 | 0.000 | |
Table 6: Frozen data and confidence-channel audits; invalid confidence is retained at .
P(True), self-probing, prompt ensemble, SAPLMA, BICR, sequence likelihood, self-consistency, semantic uncertainty, and DualRead all read the frozen RLVR actor's already committed natural answer. Consequently the latter family shares RLVR accuracy exactly; only its confidence score can change.
Policy baselines. Base is the instruction-tuned checkpoint without task RL, evaluated under the same question and answer contract. RLVR is the capability actor: the task term is and confidence receives no calibration reward. RLCR adds a pointwise proper-scoring term with (calibration weight one). DCPO keeps its constitutive segmented answer/confidence credit, hybrid group target , asymmetric clipping 0.2/0.28, and policy KL coefficient . VL-Calibration keeps dual vision/reasoning confidences, fixed harmonic aggregation, token shaping in [0.9, 1.1], the clean/augmented visual forward, and policy KL . Its native five-part output requires 512 completion tokens, versus 256 for the shared short format; this budget follows the method's own output contract and is reported here as part of its cost. Actor exposure, batch size, group size, optimizer, grader, training data, and three seeds otherwise follow Table 4.
Prompted self-check baselines. P(True) shows the frozen actor the image, question, and its own answer, asks for a one-word Yes/No judgment, and normalizes the two first-token probabilities. It uses one follow-up forward pass and never changes the original answer. Self-probing instead requests one integer probability from 0 to 100; the last valid integer is used because the actor may reason before giving the score. Prompt ensemble averages valid scores from four fixed paraphrases of that request. If none parses, the item is retained at 0.5. The first ensemble prompt is exactly the self-probing prompt, so the ensemble strictly contains rather than replaces the single-prompt baseline.
Hidden state baselines. SAPLMA is implemented as a mid-layer statement probe: one teacher-forced replay of the frozen completion, the last-token activation at 0.625 of model depth (fixed before evaluation), and a 256-128-64 ReLU classifier. It uses the same image-disjoint fit/calibration partitions and temperature protocol as Dual-Read. BICR contrasts real-image and black-image states from the same actor. Its 1024-512 MLP was selected once in a 50-trial seed-43 study; the architecture was then frozen and only weights were refit for each seed. Sequence likelihood is the geometric mean of generated answer-token probabilities, temperature-scaled only on SLAKE-train calibration images.
Sampling baselines. Self-consistency (SC@K) draws completions at temperature one and scores the deployed greedy answer by the fraction of canonical sampled answers that match it; invalid samples count as disagreement. A positive-slope Platt map is fitted on SLAKE validation and then frozen. Semantic uncertainty partitions the same completions by the shared grader's canonical answer form, computes normalized semantic entropy, and Platt-calibrates its negative on SLAKE validation. No external NLI model or target-domain labels enter the clustering.
Comparison costs. The RLVR token and sequence likelihood need no extra actor pass beyond natural generation; P(True) and self-probing need one follow-up pass; the prompt ensemble needs four; SAPLMA, BICR, and Dual-Read need one parallel teacher-forced replay; SC and semantic uncertainty need stochastic generations.
Exact Prompt Templates
We reproduce the exact model-visible instructions below. {QUESTION}, {ANSWER}, and {OPTION_TEXT} denote per-example substitutions, not literal strings. Qwen and MedGemma receive the same visible text. Their processors then apply the checkpoint's native chat template to one user message containing the image followed by the text; we add no handwritten system message. Vendor chat delimiters are therefore backbone-specific and are not part of our experimental manipulation. Automatic wrapping inside each frame is typographic only; explicit displayed line breaks are model-visible.
Shared natural-answer prompt. Base, RLVR, RLCR, DCPO, DualRead feature extraction, SAPLMA, BICR, sequence-likelihood, SC@K, semantic uncertainty, and every SLAKE/VQA-RAD/ PathVQA natural generation use:
Model-visible prompt
Examine the medical image and answer the question.
Give concise image-grounded reasoning, then one final answer and one confidence.
Use exactly:
<reasoning>...</reasoning>
<answer>...</answer>
<confidence>NN</confidence>
NN must be one integer from 0 to 100.
Question: {QUESTION}
Training and inference instantiate this template through their respective data pipelines, but after substituting the question they present byte-identical model-visible user messages. Greedy evaluation uses the instruction unchanged. SC and semantic uncertainty alter only the decoding rule (temperature one and K samples), not the prompt.
P(True). The image is shown again together with the frozen actor's already generated answer. One token is generated, and the reported score is the normalized first-token probability of Yes against No:
Model-visible prompt
Question: {QUESTION}
Proposed answer: {ANSWER}
Is the proposed answer correct for this medical image? Respond with a single word: Yes or No.
The original answer is never regenerated or modified by this follow-up.
Self-probing and prompt ensemble. The first template is the self-probing baseline. Prompt ensemble evaluates all four templates independently and averages the valid parsed probabilities: Template 1 (self-probing).
Model-visible prompt
Question: {QUESTION}
Proposed answer: {ANSWER}
How likely is the proposed answer to be correct for this medical image? Reply with a single integer from 0 to 100.
Template 2.
Model-visible prompt
Look at the image. A radiology question was asked: {QUESTION}
Someone answered: {ANSWER}
On a scale of 0 to 100, how confident are you that this answer is right? Reply with the number only.
Template 3.
Model-visible prompt
Medical image question: {QUESTION}
Candidate answer: {ANSWER}
Estimate the probability (0-100) that the candidate answer is correct. Answer with just the number.
Template 4.
Model-visible prompt
{QUESTION}
An assistant replied: {ANSWER}
Rate the chance that the reply is correct, from 0 (certainly wrong) to 100 (certainly right). Give only the integer.
Generation is greedy with at most 96 new tokens. If a completion contains a valid explicit <confidence>NN</confidence> block, that integer is used; otherwise the last integer in [0,100] is used. An invalid self-probe is retained at 0.5; the ensemble averages its valid members and returns 0.5 only when none parses.
Option-visible multiple-choice prompt. For the PMC-VQA, OmniMedVQA, and ReXVQA, the shared natural-answer instruction remains in force and the question field is:
Model-visible prompt
{QUESTION}
A. {OPTION_TEXT_A}
B. {OPTION_TEXT_B}
C. {OPTION_TEXT_C}
D. {OPTION_TEXT_D}
Select the single best option. In <answer>, write the complete text of the selected option exactly as shown; do not write only its letter.
If a source question already contains all four labeled options, the option block is not duplicated. The appended selection instruction is identical.
VL-Calibration native prompt. VL-Calibration retains its method-specific five-part interface. Its two confidence values are nested inside one confidence block, which makes the contract line 110 characters wide. That line is a single unbroken line in the model-visible prompt; inside the box it is permitted to wrap at tag boundaries, and such a wrap inserts no character.
Model-visible prompt
Examine the medical image and answer the question.
Reply with ALL FIVE parts below, in this order, using these exact tags:
<vision>what you actually see in the image, at most two sentences</vision>
<reasoning>why that supports your answer, at most two sentences</reasoning>
<answer>the final answer only: a single word or a short phrase</answer>
<analysis>one short sentence</analysis>
<confidence><vision_confidence>
N</vision_confidence>
<reasoning_confidence>
N</reasoning_confidence></confidence>
All five parts are required. Do not stop after the reasoning.
The last part must contain BOTH inner tags. Never write a single number such as <confidence>9</confidence> - it must be <confidence><vision_confidence>
8</vision_confidence>
<reasoning_confidence>
6</reasoning_confidence></confidence>,
where the first integer is how confident you are in what you saw and the second is how
confident you are in the reasoning. Both are integers from 0 to 10.
Write your own content, never copy this template.
Question: {QUESTION}
Only this baseline uses the native five-part prompt. Its two confidence values are combined by the frozen harmonic aggregation described in §E; all other policy actors use the shared prompt above. Fixed-prefix and strict-same-answer controls introduce no new elicitation: they reuse the shared prompt and teacher-force the cached natural prefix specified by each control.
F. Properties and Scope of CCG-AUC
This section restates the construction of the main paper in the form used by the supplementary tables. Donor denotes the hard-negative image ; source denotes the original image . For each source item, candidate donors have the same normalized question, a different canonical gold answer, a different image identifier, and a real image from the same evaluation distribution. The donor assignment is frozen before confidence scoring. The actor is greedily decoded on the source image and on its donor image with the question unchanged. With and the actor-defined decisive set , Natural CCG-AUC is
which is Eq. (10) of the main paper. Strict CCG-AUC applies the same rule over
, i.e. it additionally requires equal, non-empty canonical generated answers under the two images. Both variants are reported throughout this supplement. The primary DualRead/token comparison uses the same RLVR actor and therefore exactly the same answers, labels, image pairs, and decisive set.
Actor-side compatibility diagnostics. For completeness, we also report two answer-side quantities. Let be the complete frozen set of source/hard-negative pairs, before conditioning on either confidence or actor correctness. We define
VRS is the actor's net accuracy change and can be offset by pairs that flip in the opposite direction; VBR is the incidence of the decisive failure event used to define CCG eligibility. Neither quantity contains a confidence score. They are consequently identical for the RLVR token, PSR, P-Visual, DualRead, and every other methods attached to the same frozen RLVR actor. They are reported as actor-side diagnostics and carry no information about any confidence interface.
A parameter-, scale-, and model-free rule. CCG-AUC applies no post-processing or calibration to the model's outputs. It is parameter-free: it fits nothing, uses no validation split, and has no free coefficient or temperature. It is scale-free: depends only on the sign of the within-item difference , so the score is invariant to any strictly increasing reparameterization of the confidence scale (probability versus log-odds, arbitrary temperature). It is model-agnostic: the rule consumes only per-item pairs and evaluates any confidence signal—a verbalized token, hidden state, or sequence likelihood—as a black box. Because and come from the same estimator on the same item, comparisons across estimators need no cross-model normalization.
Preconditions and transferability. These properties make the metric portable but place the burden on the data construction. CCG-AUC requires that the dataset admit same-question hard negatives: a repeated-question structure (the same normalized question asked of multiple images), gold answers (to select a donor image with a different answer and to compute ), and a shared grader. It further requires statistical power: we admit a cell only when spans at least 30 independent source and donor images, and otherwise flag it underpowered and report an interval only. Consequently CCG-AUC transfers to any VLM that exposes a confidence signal and any VQA dataset with groupable QA structure and labels, without retuning; conversely it is not constructible—or is underpowered—on datasets of near-unique questions or without gold. The construction uses real in-distribution hard negatives rather than blanked or shuffled images, so the substituted input stays inside the evaluation distribution and the measured response is not a response to input novelty.
Inference and scope. Because multiple questions can share a source image, we use a paired source-image-cluster bootstrap for confidence intervals and paired system comparisons. CCG-AUC measures whether the confidence score tracks answer-decisive visual evidence; it is not pixel localization, clinical causal attribution, or a claim that the actor's answer is more grounded (the latter is a separate actor-level precondition).
G. Paired Bootstrap Contrasts
Table 7 summarizes paired image-cluster bootstrap contrasts for P-Visual versus P-State on SLAKE validation and for DualRead versus RLCR on the ID and OOD evaluation splits.
H. Extended Reliability Results
Calibration metrics corresponding to the main table
The main-paper table prioritizes discrimination and grounding and therefore omits two calibration columns. Tables 8 and 9 restore ECE-15 and Brier alongside Acc./AUROC. The SLAKE columns are computed on the ID test set. For six OOD test sets, each metric is first computed separately on VQA-RAD, PathVQA, PMC-VQA, OmniMed-VQA, ReXVQA, and the closed subset of VQA-Med 2019; the six values are then averaged with equal domain weight for each seed, followed by the across-seed summary. Base is one frozen zero-shot run; other rows summarize actor seeds {17, 29, 43}.
Per-domain OOD reliability diagrams
Figures 5–10 show the calibration behavior behind the six per-domain OOD rows above, for the complete roster of eight confidence interfaces rather than a two-method excerpt. Every panel uses the exact frozen per-item predictions used to compute Tables 8 and 9; no OOD example is used to fit a reader, temperature, bin edge, or other parameter. Each figure carries one domain, with the first two rows for Qwen3VL-2B and the last two for MedGemma1.5-4B, and the same left-to-right method order in every row pair. The three equal-size seed arrays are concatenated only to make each reliability diagram readable, so the ECE printed inside a panel is the pooled diagnostic ECE, whereas the tables report the mean and sample standard deviation of the three separately computed seed-level ECE values. All panels use 15 fixed equal-width bins on the full [0, 1] confidence range; empty bins carry no mass and do not enter ECE. Panels are drawn on a common axis so that the occupied confidence support of each interface is directly comparable.
Confidence-support audit. Reliability diagrams bin the confidence axis and therefore do not show how many distinct values a confidence channel emits. Table 6 records that quantity directly for the seed-43 SLAKE-test predictions.
Qwen RLVR assigns confidence one to 1060/1061 examples and MedGemma RLVR assigns one to all 1061 examples; RLCR emits two distinct endpoint values; DualRead emits a distinct non-endpoint score for every example. This audit measures score resolution only, separately from how the scores rank correctness. For this mechanism audit, support statistics are computed over valid parsed scores and the valid rate is reported separately; the deployment metrics retain invalid examples and impute confidence 0.5 as specified in Section D.
Answer-type reliability. Table 10 compares open- and closed-question reliability and selective prediction.
I. Grounding Details
Table 11 consolidates per-domain OOD grounding, the paired SLAKE actor/confidence audit, and decisive-set eligibility under the frozen CCG-AUC protocol in Section F. Confidence readers and temperatures are not refit on these evaluation sets.
J. Reproducibility and Scope
For each seed, the order is greedy generation, deterministic grading, one teacher-forced replay, reader fitting on SLAKE-train fitting images, temperature fitting on disjoint SLAKE-train calibration images, and frozen evaluation on ID/OOD manifests. Two frozen aggregate records back the reported numbers: one holding the method × domain × seed matrix behind the OOD6 averages, and one holding the three-domain CCG decomposition. Both are released with the code. Readers are actor-specific and require internal-state access. OOD temperatures remain frozen. CCG is conditional on an actor-defined decisive set, is underpowered below 30 independent source/donor images, and does not measure pixel localization or clinical causality.




Figure 5: VQA-RAD reliability (n = 600; short answer). Qwen rows precede MedGemma rows.




Figure 6: PathVQA reliability (n = 1000; short answer). Qwen rows precede MedGemma rows.




Figure 7: PMC-VQA reliability (n = 1000; option visible). Qwen rows precede MedGemma rows.




Figure 8: OmniMedVQA reliability (n = 920; option visible). Qwen rows precede MedGemma rows.




Figure 9: ReXVQA reliability (n = 1000; option visible). Qwen rows precede MedGemma rows.

Figure 10: VQA-Med 2019 reliability (; closed answer). Qwen rows precede MedGemma rows.
| Backbone | Contrast (split) | AUROC | Brier |
|---|---|---|---|
| Qwen3VL-2B | P-Visual – P-State (val.) | ||
| DualRead – RLCR (ID) | |||
| DualRead – RLCR (OOD) | |||
| MedGemma1.5-4B | P-Visual – P-State (val.) | — | |
| DualRead – RLCR (ID) | |||
| DualRead – RLCR (OOD) |
Table 7: Paired image-cluster bootstrap contrasts (mean std).
| Backbone | Method | SLAKE Acc./AUROC (top); ECE-15/Brier (bottom) | VQA-RAD | PathVQA |
|---|---|---|---|---|
| Qwen3VL-2B | Base | |||
| RLCR | .608 009/.822 014\n.150 012/.150 012 | .440 009/.709 006\n.312 010/.312 010 | .330 007/.820 008\n.218 019/.218 019 | |
| DCPO | .640 003/.789 007\n.190 016/.189 016\n.591 010/.756 026 | .448 011/.731 010\n.277 003/.277 003\n.443 017/.709 006 | .335 010/.800 019\n.214 009/.214 009\n.332 012/.775 007 | |
| VL-Cal. | .183 048/.207 036\n.639 009/.535 059 | .282 057/.294 034\n.453 006/.490 019 | .276 085/.273 060\n.339 003/.465 061 | |
| GRPO (RLVR) | .359 012/.365 005\n.639 009/.609 012 | .538 017/.531 028\n.453 006/.444 005 | .634 044/.621 067\n.339 003/.344 019 | |
| P(True) | .381 013/.385 011\n.639 009/.517 033 | .433 016/.460 012\n.453 006/.447 020 | .504 028/.530 025\n.339 003/.379 009 | |
| Self-prob. | .408 023/.411 018\n.639 009/.534 034 | .567 030/.561 034\n.453 006/.459 012 | .653 032/.646 040\n.339 003/.372 005 | |
| Prompt ens. | .348 003/.362 002\n.639 009/.942 004 | .457 009/.483 013\n.453 006/.747 008 | .599 027/.600 042\n.339 003/.833 024 | |
| SAPLMA | .042 007/.095 005\n.639 009/.934 002 | .118 012/.215 008\n.453 006/.686 019 | .157 060/.189 038\n.339 003/.704 024 | |
| BICR | .035 015/.099 003\n.639 009/.952 004 | .190 050/.266 020\n.453 006/.731 008 | .143 052/.224 024\n.339 003/.784 078 | |
| DualRead | .031 007/.083 002 | .160 017/.233 008 | .170 094/.224 073 | |
| Base | ||||
| RLCR | .657 027/.771 021\n.172 019/.172 019 | .468 039/.676 044\n.340 026/.340 026 | .351 011/.663 067\n.429 088/.429 088 | |
| DCPO | .678 003/.752 018\n.187 011/.187 012\n.587 005/.851 005 | .445 078/.691 038\n.342 080/.342 081\n.477 013/.754 012 | .318 060/.765 027\n.313 027/.313 026\n.343 015/.713 031 | |
| VL-Cal. | .085 028/.127 015\n.677 011/.506 011 | .161 068/.215 027\n.498 011/.504 007 | .202 040/.234 013\n.354 010/.503 004 | |
| GRPO (RLVR) | .229 100/.278 051\n.677 011/.574 026 | .316 243/.389 124\n.498 011/.558 013 | .460 236/.477 195\n.354 010/.439 045 | |
| P(True) | .362 019/.362 019\n.677 011/.597 110 | .478 023/.478 024\n.498 011/.551 055 | .655 013/.654 011\n.354 010/.444 025 | |
| Self-prob. | .289 039/.298 037\n.677 011/.626 073 | .437 036/.445 039\n.498 011/.553 013 | .580 020/.592 029\n.354 010/.454 006 | |
| Prompt ens. | .242 047/.272 034\n.677 011/.942 011 | .397 066/.415 054\n.498 011/.736 010 | .560 049/.554 061\n.354 010/.743 059 | |
| SAPLMA | .035 004/.087 010\n.677 011/.930 007 | .138 020/.228 005\n.498 011/.723 002 | .162 077/.238 055\n.354 010/.723 091 | |
| BICR | .040 007/.100 007\n.677 011/.947 005 | .271 039/.288 023\n.498 011/.754 016 | .176 071/.239 055\n.354 010/.807 034 | |
| DualRead | .038 008/.082 002 | .142 030/.219 017 | .144 046/.196 025 |
Table 8: Reliability on SLAKE, VQA-RAD, and PathVQA. Cells show Acc./AUROC over ECE-15/Brier; bold excludes Acc.
| Backbone Method | PMC-VQA | OmniMed Acc./AUROC (top); ECE-15/Brier (bottom) | ReXVQA | VQA-Med19-C | OOD6 | |
|---|---|---|---|---|---|---|
| Qwen3VL-2B | Base | .449/.681 | .714/.705 | .493/.617 | .406/.799 | .450/.696 |
| .468/.437 | .225/.228 | .441/.426 | .429/.361 | .438/.399 | ||
| RLCR | .511 010/.563 005 | .709 003/.561 020 | .285 044/.500 014 | .677 039/.523 024 | .492 012/.613 008 | |
| .433 001/.432 001 | .289 005/.289 005 | .615 022/.615 022 | .312 031/.312 031 | .363 003/.363 003 | ||
| .501 005/.588 023 | .700 012/.613 011 | .275 030/.488 022 | .688 031/.512 001 | .491 004/.622 005 | ||
| DCPO | .413 024/.411 025 | .289 021/.288 021 | .572 034/.571 034 | .323 018/.323 018 | .348 006/.347 007 | |
| .480 008/.622 029 | .716 010/.648 047 | .352 025/.508 008 | .661 039/.538 053 | .497 010/.633 020 | ||
| VL-Cal. | .343 027/.354 025 | .240 084/.276 070 | .444 067/.436 066 | .253 028/.278 017 | .306 024/.318 016 | |
| .514 006/.532 045 | .709 008/.567 105 | .283 007/.492 012 | .667 018/.495 008 | .494 004/.507 008 | ||
| GRPO (RLVR) | .409 132/.427 099 | .244 080/.269 037 | .642 134/.629 156 | .368 070/.373 079 | .472 056/.475 051 | |
| .514 006/.689 010 | .709 008/.787 008 | .283 007/.591 055 | .667 018/.471 032 | .494 004/.555 010 | ||
| P(True) | .388 021/.396 014 | .222 002/.232 003 | .522 045/.515 049 | .440 033/.421 037 | .418 018/.426 014 | |
| .514 006/.600 034 | .709 008/.666 031 | .283 007/.441 066 | .667 018/.513 029 | .494 004/.508 028 | ||
| Self-prob. | .380 055/.387 045 | .205 037/.231 014 | .555 091/.559 103 | .511 010/.508 007 | .479 039/.482 038 | |
| .514 006/.625 015 | .709 008/.717 019 | .283 007/.402 071 | .667 018/.538 032 | .494 004/.519 019 | ||
| Prompt ens. | .362 052/.374 038 | .191 034/.222 012 | .556 069/.552 077 | .276 040/.297 042 | .407 027/.421 023 | |
| .514 006/.645 005 | .709 008/.755 006 | .283 007/.537 033 | .667 018/.666 025 | .494 004/.697 006 | ||
| SAPLMA | .289 032/.328 022 | .162 030/.208 011 | .317 115/.344 090 | .210 017/.231 015 | .209 042/.253 027 | |
| .514 006/.619 015 | .709 008/.643 008 | .283 007/.513 014 | .667 018/.700 048 | .494 004/.644 005 | ||
| BICR | .443 012/.445 011 | .282 014/.285 012 | .689 016/.679 021 | .241 017/.255 013 | .332 011/.359 007 | |
| .514 006/.612 011 | .709 008/.667 014 | .283 007/.520 040 | .667 018/.683 034 | .494 004/.666 021 | ||
| DualRead | .249 024/.311 010 | .166 027/.229 014 | .305 020/.342 020 | .253 027/.262 023 | .217 028/.267 021 | |
| MedGenmal.5-4B | Base | .365/.698 | .586/.641 | .693/.564 | .562/.581 | .494/.590 |
| .476/.418 | .247/.276 | .188/.242 | .357/.365 | .371/.378 | ||
| RLCR | .490 010/.590 005 | .653 043/.609 042 | .858 010/.578 010 | .635 033/.492 013 | .576 001/.601 025 | |
| .415 002/.414 002 | .377 034/.377 034 | .308 024/.308 024 | .375 016/.375 016 | .374 019/.374 019 | ||
| .490 012/.570 038 | .660 034/.629 007 | .850 008/.565 017 | .604 039/.507 013 | .561 021/.621 013 | ||
| DCPO | .436 032/.435 032 | .347 016/.347 016 | .251 012/.251 012 | .393 043/.392 045 | .347 022/.347 023 | |
| .468 004/.643 044 | .639 053/.665 065 | .816 010/.661 047 | .615 018/.532 049 | .560 005/.661 025 | ||
| VL-Cal. | .271 065/.308 041 | .355 071/.361 071 | .330 019/.328 033 | .266 117/.308 070 | .264 056/.292 039 | |
| .493 005/.501 002 | .703 020/.502 003 | .850 002/.500 000 | .620 039/.505 008 | .586 005/.502 003 | ||
| GRPO (RLVR) | .320 238/.390 128 | .234 064/.265 037 | .171 132/.168 049 | .219 160/.300 050 | .286 138/.331 082 | |
| .493 005/.589 004 | .703 020/.738 017 | .850 002/.784 012 | .620 039/.453 073 | .586 005/.594 015 | ||
| P(True) | .499 007/.498 007 | .283 020/.280 020 | .147 003/.146 004 | .459 083/.446 082 | .420 016/.417 015 | |
| .493 005/.552 040 | .703 020/.560 049 | .850 002/.505 038 | .620 039/.548 094 | .586 005/.527 045 | ||
| Self-prob. | .422 026/.441 025 | .229 064/.263 043 | .154 058/.165 021 | .347 027/.351 026 | .362 034/.376 026 | |
| .493 005/.539 034 | .703 020/.559 049 | .850 002/.571 061 | .620 039/.545 078 | .586 005/.537 031 | ||
| Prompt ens. | .399 034/.421 021 | .218 048/.252 032 | .105 026/.137 008 | .314 012/.329 012 | .332 027/.351 023 | |
| .493 005/.651 023 | .703 020/.689 065 | .850 002/.651 049 | .620 039/.653 058 | .586 005/.687 018 | ||
| SAPLMA | .274 062/.315 042 | .352 203/.362 167 | .410 262/.384 231 | .234 066/.269 035 | .262 084/.299 068 | |
| .493 005/.587 026 | .703 020/.580 054 | .850 002/.552 103 | .620 039/.649 051 | .586 005/.635 022 | ||
| BICR | .228 072/.308 038 | .262 118/.305 074 | .411 270/.371 200 | .299 073/.313 061 | .274 045/.304 028 | |
| .493 005/.619 025 | .703 020/.535 063 | .850 002/.546 061 | .620 039/.623 076 | .586 005/.647 034 | ||
| DualRead | .244 118/.312 064 | .376 175/.395 137 | .445 259/.393 207 | .187 030/.251 017 | .256 075/.294 059 | |
Table 9: Reliability on PMC-VQA, OmniMedVQA, ReXVQA, VQA-Med 2019, and OOD6; see Table 8 for format.
| Backbone | Dataset | Method | Acc | AUROC | ECE | Brier | AURC | HCE@.9 |
|---|---|---|---|---|---|---|---|---|
| Open questions | ||||||||
| Qwen3VL-2B | SLAKE | RLCR | .480 .011 | .885 .016 | .117 .018 | .117 .018 | .261 .026 | .083 .023 |
| DualRead | .518 .004 | .973 .006 | .039 .001 | .063 .005 | .155 .003 | .005 .003 | ||
| VQA-RAD | RLCR | .143 .009 | .630 .013 | .210 .016 | .210 .016 | .792 .013 | .126 .027 | |
| DualRead | .158 .005 | .554 .047 | .223 .029 | .205 .025 | .775 .018 | .071 .009 | ||
| MedGemma1.5-4B | SLAKE | RLCR | .552 .034 | .828 .024 | .164 .024 | .164 .024 | .247 .046 | .124 .041 |
| DualRead | .581 .023 | .970 .005 | .053 .015 | .069 .003 | .117 .013 | .003 .002 | ||
| VQA-RAD | RLCR | .143 .025 | .635 .093 | .394 .092 | .394 .092 | .811 .004 | .346 .081 | |
| DualRead | .151 .017 | .640 .028 | .209 .023 | .202 .038 | .758 .021 | .072 .039 | ||
| Closed questions | ||||||||
| Qwen3VL-2B | SLAKE | RLCR | .808 .006 | .516 .008 | .200 .007 | .200 .007 | .187 .009 | .182 .010 |
| DualRead | .828 .018 | .841 .010 | .065 .004 | .114 .005 | .047 .005 | .010 .004 | ||
| VQA-RAD | RLCR | .633 .011 | .506 .011 | .377 .014 | .377 .014 | .364 .013 | .342 .017 | |
| DualRead | .644 .007 | .641 .009 | .174 .016 | .254 .010 | .235 .014 | .020 .010 | ||
| MedGemma1.5-4B | SLAKE | RLCR | .819 .017 | .517 .016 | .183 .014 | .183 .014 | .176 .015 | .172 .015 |
| DualRead | .825 .009 | .851 .011 | .044 .017 | .103 .004 | .049 .003 | .022 .003 | ||
| VQA-RAD | RLCR | .679 .049 | .528 .039 | .305 .017 | .305 .017 | .308 .030 | .298 .019 | |
| DualRead | .723 .015 | .617 .013 | .151 .014 | .227 .016 | .201 .007 | .060 .037 | ||
Table 10: Open/closed reliability for RLCR and DualRead; bold excludes Acc.
(a) Per-domain OOD CCG-AUC
| Backbone | Method | VQA-RAD | PathVQA | VQA-Med 2019 closed | |||
|---|---|---|---|---|---|---|---|
| Nat.↑ | Strict↑ | Nat.↑ | Strict↑ | Nat.↑ | Strict↑ | ||
| Qwen3VL-2B | Base | .786 | .700 | .692 | .500 | .867 | .667 |
| RLCR | .500±000 | .500±000 | .521±043 | .499±040 | .528±048 | .528±048 | |
| DCPO | .519±032 | .533±058 | .492±013 | .487±022 | .506±092 | .506±092 | |
| VL-Cal. | .495±064 | .486±105 | .608±065 | .593±085 | .595±135 | .597±134 | |
| GRPO (RLVR) | .521±036 | .500±000 | .567±115 | .548±082 | .500±000 | .500±000 | |
| P(True) | .419±038 | .250±000 | .692±095 | .556±076 | .431±237 | .431±237 | |
| Self-prob. | .421±028 | .292±144 | .518±055 | .500±071 | .535±107 | .535±107 | |
| Prompt ens. | .440±004 | .292±072 | .560±104 | .512±055 | .556±136 | .556±136 | |
| SAPLMA | .509±264 | .333±382 | .709±010 | .687±048 | .431±214 | .431±214 | |
| BICR | .593±160 | .833±144 | .455±161 | .415±137 | .542±072 | .542±072 | |
| DualRead | .556±096 | .417±144 | .511±140 | .461±091 | .806±173 | .806±173 | |
| MedGemma1.5-4B | Base | .429 | .375 | .542 | .250 | .536 | .500 |
| RLCR | .500±000 | .500±000 | .557±013 | .486±024 | .500±000 | .500±000 | |
| DCPO | .500±000 | .500±000 | .705±036 | .671±049 | .500±000 | .500±000 | |
| VL-Cal. | .524±041 | .542±072 | .675±027 | .597±020 | .596±084 | .524±100 | |
| GRPO (RLVR) | .500±000 | .500±000 | .511±019 | .519±032 | .500±000 | .500±000 | |
| P(True) | .387±049 | .244±214 | .605±071 | .558±128 | .623±167 | .623±167 | |
| Self-prob. | .493±061 | .500±000 | .606±108 | .636±127 | .576±084 | .576±084 | |
| Prompt ens. | .491±159 | .411±084 | .575±206 | .574±247 | .550±109 | .550±109 | |
| SAPLMA | .381±206 | .644±336 | .667±185 | .661±179 | .602±040 | .602±040 | |
| BICR | .646±067 | .656±150 | .541±096 | .574±085 | .701±221 | .701±221 | |
| DualRead | .595±367 | .756±214 | .540±062 | .524±099 | .769±184 | .769±184 | |
(b) SLAKE actor audit and paired confidence comparison
| Backbone | Acc.real | Acc.hn | VRS | |ε| | Src/Dnr | VBR | DualRead | Token | Paired Δ |
|---|---|---|---|---|---|---|---|---|---|
| Qwen3VL-2B | .584±020 | .532±014 | .053±007 | 109.7±3.1 | 59.7±1.5/47.7±2.1 | .248±007 | .784±009 | .516±031 | + .269±.022 |
| MedGemma1.5-4B | .600±010 | .566±018 | .034±015 | 111.0±8.7 | 59.7±2.5/48.0±3.6 | .251±020 | .819±030 | .503±005 | + .316±.032 |
(c) Natural/strict decisive-set audit
| Actor | Qwen3VL-2B | MedGemma1.5-4B | ||||
|---|---|---|---|---|---|---|
| |ε| | Strict | Retained | |ε| | Strict | Retained | |
| RLVR | 109.7±3.1 | 75.0±5.3 | 65–72% | 111.0±8.7 | 77.7±8.5 | 67–72% |
| RLCR | 101.0±3.0 | 79.0±2.0 | 74–83% | 102.7±8.1 | 67.0±1.7 | 61–69% |
| DCPO | 110.3±8.5 | 81.0±7.0 | 73–74% | 96.7±8.1 | 61.7±4.5 | 62–67% |
| VL-Cal. | 94.0±5.3 | 66.3±2.1 | 69–73% | 75.0±3.0 | 54.0±1.0 | 71–74% |
Table 11: Grounding evidence: (a) OOD CCG-AUC, (b) paired SLAKE audit, and (c) eligibility. Bold marks the best confidence score.