arXiv:2609.06810cs.ROSep 2026

Manuscript Offprint

arXiv:2609.06810

OCTN: Neural OCT Representations for Robot-Guided Precision Intervention

Ravi Prakash, Ryan P. McNabb, Patrick J. Codd, Shan Lin

Ravi Prakash, Student Member, IEEE, Ryan P. McNabb Member, IEEE, Patrick J. Codd, and Shan Lin

Project Website

Abstract—Optical coherence tomography (OCT) offers compact, contactless, micron-scale imaging suitable for intraoperative guidance, but native OCT volumes are discretely sampled, anisotropic, and currently inefficient for downstream geometric reasoning and robot integration. We present OCTN (pronounced “octane”), an implicit neural representation framework that converts volumetric OCT scans into a continuous, differentiable, and spatially faithful tissue-intensity field. OCTN uses a two-stage hybrid training strategy that combines supervision from acquired voxels with inter-slice interpolations, preserving B-scan fidelity while improving continuity in sparsely sampled regions. For versatility, we first show that OCTN enables fast volumetric reasoning by storing the learned tissue representation natively on the GPU, supporting intensity-based spatial queries with up to 43× speedup over conventional CPU processing. We then demonstrate OCTN-enabled OCT-guided robotic laser surgery where the continuous tissue representation supports implicit surface discovery and surface-constrained path planning via multiple optimization strategies, including Newton- and SGD-based optimization. Next, OCTN enables reconstruction of dense volumetric structure from sparsely acquired B-scans, while reducing acquisition time by 4× and preserving clinically relevant structures. Across the newly generated Duke TissueOCT dataset and public OCT datasets, OCTN achieves robust high-fidelity reconstruction with PSNR > 30 dB with training time < 10 s and preserves surface consistency within 10μm Chamfer distance relative to baseline reconstruction. The TissueOCT dataset and code are publicly available at raprakashvi.github.io/octn.

Index Terms— Optical Coherence Tomography, Implicit Neural Representation, Robotic Surgery, Image Reconstruction, 3D Reconstruction

I. INTRODUCTION

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible. Manuscript currently under review.

Aspects of the technology described in this manuscript are the subject of the following patent application: R. Prakash, R. P. McNabb, P. J. Codd, and S. Lin, “Systems and methods for neural OCT tissue representations for robot-guided intervention,” U.S. Provisional Patent Application No. 64/045,412, patent pending.

Corresponding author: Ravi Prakash.

Ravi Prakash, Ryan P. McNabb, and Patrick J. Codd are with Duke University, Durham, NC 27705 USA (e-mail: first-name.lastname@duke.edu).

Shan Lin is with Arizona State University, Phoenix, AZ 85287 USA (e-mail: shan.lin.2@asu.edu).

OPTICAL Coherence Tomography (OCT) is a contactless, non-ionizing sensing modality suited for high-resolution, near-real-time surgical imaging [1]. OCT allows micron-scale visualization of surface and shallow subsurface tissue features within a compact form factor. These properties make OCT attractive for intraoperative imaging and robot-guided intervention [2] over conventional counterparts. Although currently intraoperative ultrasound (IOUS) is widely used, it requires acoustic contact and provides limited spatial resolution ( ∼\sim 0.5 mm) compared to OCT. Since its inception, OCT has established clinical use in ophthalmology [3]–[5] and has more recently been explored in neurosurgery [6]–[8], breast imaging [9], [10], dermatology [11], [12], and urology [13]. However, broader adoption remains limited by a restricted field of view (FoV), anisotropic scaling, and a computationally cumbersome discrete volume representation.

Recent advances in robot-mounted OCT [13]–[18] have enabled a larger field of view (FoV), surface-aware high-resolution imaging [19], extending utility. Despite this progress, native OCT volumes remain discretely sampled with anisotropic resolution and sampling, making them cumbersome to use directly for downstream computation. As a result, geometric reasoning and planning over OCT data remain inefficient and slow. Therefore, devising an isotropic and queryable representation of OCT data can overcome these limitations. Implicit neural representation (INR) is a Multi-Layer Perceptron (MLP) based method to parameterize the tissue volume by learning a mapping from spatial coordinates to intensity [20]. This results in a continuous, isotropic, and queryable neural encoding of the volume.

In recent years, INR have gained prominence in medical imaging [20] for reconstruction [21], [22], super-resolution [23], [24], segmentation, and registration [24], [25]. Unlike INR for natural 3D scenes, which often rely on multi-view image capture [26], medical imaging modalities are typically reconstructed from sparsely sampled parallel single-view cross-sectional slices. Methods such as CuNeRF [23] have adapted INRs for CT and MRI scans by learning a mapping from 3D spatial coordinates to voxel intensity, yielding a spatially correct continuous volume representation. When available, auxiliary information such as attenuation can further augment input representation and enhance reconstruction quality [27]. Expanding these methods to OCT requires handling sensor-specific idiosyncrasies and anisotropies under tight computational constraints for relatively small tissue volumes. Prior

IEEE TRANSACTIONS AND JOURNALS TEMPLATE

2

Figure

Fig. 1. System overview. a) OCTN maps discrete, anisotropic OCT voxels to a continuous tissue-intensity field using on-grid samples and off-grid inter-slice supervision. Its multiresolution hash-grid and MLP enable fast training, arbitrary spatial queries, and 4× sparse acquisition. b) OCTN supports smooth, surface-aware robotic laser path planning. c) OCTN balances sparse C-scan reconstruction, image fidelity, fast 3D querying, and surface constraints. d) Its GPU-native representation enables threshold-based tissue queries with up to 43× faster spatial reasoning.

works have addressed OCT sampling anisotropy either through additional sensing modalities such as scanning laser ophthalmoscopy [24] or through physics-informed modeling of A-scan formation [21]. Despite these advances, existing INR-based OCT methods rely on specialized hardware, multimodal sensing, and prolonged training time, limiting their practicality for broader intraoperative deployment.

In this work, we present OCTN, an INR-based method for learning a continuous representation of OCT volumes under anisotropic sampling and speckle noise (Fig. 1a). OCTN enables constraint-based optimization for robot path planning, Fig. 1b, with high-fidelity image reconstruction Fig. 1c, supports fast volumetric queries Fig. 1d, while recovering spatially accurate geometry from a sparsely sampled volume. OCTN enhances the existing OCT experience in terms of resolution, speed, and robotic guidance. Overall, we propose:

  • Hybrid framework for continuous OCT representation: We introduce a two-stage training strategy combining discrete and interpolated voxels to learn a continuous, isotropic OCT representation.

  • Fast query and robot path planning: We demonstrate OCTN enables 19×–43× faster volumetric queries than conventional CPU-based processing through a GPU-native implementation. Furthermore, its continuous representation supports constrained surface-aware path planning using Newton- and Stochastic Gradient Descent (SGD)-based optimization separately, on an OCT-guided robotic laser

platform [18] Fig. 1b.

  • Sparse volume reconstruction: We show that OCTN supports reconstruction from sparsely sampled B-scan stacks, enabling up to 4× reduction in B-scan density within clinical constraints. For a critically sampled volume, this corresponded to reducing acquisition time from 24 s to 6 s.

  • TissueOCT Benchmarking: We release an open-source Duke TissueOCT dataset and comprehensive set of global and local metrics to benchmark learned B-scan fidelity, sparse to dense volume reconstruction quality, visualization speed for volumetric queries, and surface aware path planning over realistic tissue samples. The dataset consists of critically sampled OCT volumes from ex vivo tissues at varying noise and artifact levels, as seen in Table I, together with calibration parameters for 3D reconstruction.

References (41)