Manuscript Offprint
arXiv:2609.06914A visual large language foundational model for medical image recognition using clinician-oriented social media
Author Information
Lingxuan Hou , Yuhua Xie , Yue Hu , Yan Zhuang , Junqi Li , Chengzhi Xia , Binh Phu Nguyen , Abubakar Siddique , Minh Nguyen , Yao Hou , Yanju Bao , Kexin Liu , Ke Chen , Jianjun Sun , Zeqi Li , Trung Nguyen , Jiangli Lin
2 School of Engineering, Computer & Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
3 Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Beijing, China
4 School of Mathematics and Statistics, Victoria University of Wellington, Wellington, New Zealand
5 Jincheng General Hospital, Jincheng, Shanxi, China
*Corresponding author: trung.nguyen@aut.ac.nz (T.N.), zhuangy@scu.edu.cn (Y.Z.), linjiangli@scu.edu.cn (J.L.)
Author Contributions
L.H., Y.X., Y.Z. and J.L. conceived the study. L.H. and T.N. conducted data collection, data analysis, model development and model validation. L.H., T.N., Y.Z. and J.L. drafted the manuscript and supplementary materials. K.C. and T.N. provided computational resources and hardware support. Y.H., J.L., Y.B., K.L. and J.S. provided clinical expertise and contributed to clinical evaluation. T.N., Y.Z. and J.L. supervised the study. All authors critically reviewed the manuscript and approved the final version.
Corresponding author
Correspondence to: Trung Nguyen, Yan Zhuang and Jiangli Lin
Abstract
Large language models (LLMs) have demonstrated strong capabilities across diverse domains, showing considerable potential in medicine. However, their application in medical settings remains limited by the scarcity of visual-question-answering (VQA) datasets that capture clinical reasoning and explicit image-text alignment. Here we leverage de-identified medical images and expert commentaries shared on clinician oriented social media. By combining advanced LLM with clinician-in-the-loop verification, we have established a rigorous pipeline to construct a long-form medical VQA dataset with over one million VQA pairs, named ThoughtMed-1M, designed to capture structured clinical logic and medical image-text alignment. To demonstrate its utility, we developed a FFoundational LLM Trained on ThoughtMed-1M (FOLTMed). FOLTMed achieved state-of-the-art performance on 42 medical VQA benchmark datasets (macro accuracy 85.4%) and generated more clinically coherent responses in ThoughtMed-1M testset, outperforming state-of-the-art models by 3%-5% across factuality and similarity metrics, highlighting a scalable paradigm for advancing research on clinically grounded multimodal LLMs.
Main
Artificial intelligence (AI) has achieved remarkable advances across a broad range of perceptual and reasoning tasks, driven not only by innovations in model architecture but also by the availability of large-scale, high-quality datasets. Among these foundational resources, ImageNet transformed computer vision by enabling standardized benchmarking and supervised pretraining at scale, thereby catalysing the development of modern deep learning models . More recently, multimodal large language models (LLMs) have emerged as a powerful AI paradigm that integrates visual and textual information to support image interpretation, cross-modal reasoning, and question answering . Their adaptation to medicine could extend clinical AI support beyond isolated image classification . By integrating imaging findings with patient histories and medical knowledge, these models could support diagnostic reasoning, report generation, case triage, longitudinal assessment, and clinically meaningful communication , while helping clinicians identify subtle findings or clinically relevant information that might otherwise be overlooked .
Developing these capabilities, however, requires extensive, high-quality training data that explicitly connect visual content with medical domain knowledge and reasoning processes. Unlike conventional vision models trained primarily with category-level annotations, adapting multimodal LLMs to medicine requires large-scale, high-quality paired image-text data and visual question answer (VQA) supervision that encode clinical knowledge, structured reasoning, and explicit image-text alignment. Yet, to the best of our knowledge, the medical multimodal LLM field still lacks an ImageNet-scale resource designed to provide such supervision across diverse medical domains. Several high-quality medical VQA datasets, such as PMC-VQA , SLAKE , and VQA-RAD , have been proposed to adapt LLMs to domain-specific tasks or to supplement medical visual knowledge. However, most existing resources remain dominated by closed-ended questions, such as yes/no responses or modality recognition, and short-answer formats . As a result, they provide limited supervision for learning clinically meaningful image-text alignment, spatially grounded interpretation, and structured diagnostic reasoning. Moreover, the majority of existing datasets are restricted to a single imaging modality, organ system, or narrowly defined task, which limits the generalizability of medical multimodal LLMs across diverse clinical scenarios .
Clinical scenarios continue to grow in complexity, driven by expanding recognition of disease subtypes, rare conditions, and phenotypic heterogeneity , alongside a growing understanding of shared and interacting pathophysiological mechanisms across diseases . This increasing complexity places greater demands on causal reasoning and further exposes limitations in the availability and representation of clinical data. While task-specific data collection and small-sample fine-tuning can partially mitigate these issues, such datasets are often access-restricted, limited in scale, and insufficient to provide the breadth and diversity required for training and evaluating general-purpose medical multimodal LLMs across diverse downstream tasks. These data limitations constrain effective multimodal pretraining, cross-domain generalization, reproducible benchmarking, and efficient adaptation to specific biomedical problems. They also substantially raise the technical and resource barriers to developing and systematically investigating medical multimodal LLMs, thereby slowing methodological innovation and broader progress across the field. Consequently, there remains a critical need for a unified, large-scale, reasoning-oriented medical VQA resource that spans diverse imaging modalities, disease categories, and clinical tasks. Such a resource could serve as an ImageNet-like foundation for medical LLMs, accelerating the development and evaluation of clinically grounded multimodal AI.
Online medical platforms have emerged as valuable sources of large-scale, real-world biomedical data, with continuously expanding repositories of de-identified medical images and expert-authored clinical descriptions that can support the training and evaluation of medical AI models and the adaptation of LLM-based systems to specific clinical applications. These resources position such platforms as a promising yet underexplored foundation for developing medical multimodal LLMs. A substantial volume of such image-text pairs has begun to be selectively explored in specific research domains, demonstrating encouraging performance in downstream tasks. For example, Huang et al. curated approximately 200,000 pathology image-text pairs from social media platforms such as Twitter to construct the OpenPath dataset. Using this dataset, Pathology Language-Image Pretraining model was trained and achieved state-of-the-art (SOTA) performance across multiple pathology benchmarks. Publicly available clinician-authored resources, such as Radiopaedia and figure1.com, contain large collections of real-world medical images accompanied by expert descriptions and clinical discussions that span diverse diseases and imaging modalities . These resources provide medically grounded supervision that closely reflects authentic diagnostic reasoning, however, they have not been systematically leveraged as scalable sources of image-specific medical knowledge for training medical LLMs, partly because of their heterogeneous and unstructured formats and the substantial effort required for data curation, standardization, and validation . This shows that there is a lacks of large-scale, clinically grounded resources capable of supporting medical multimodal LLMs in image understanding, visual grounding, and clinical reasoning, which collectively limits progress.
To address this gap, we introduce ThoughtMed-1M, a large-scale medical VQA dataset that systematically transforms clinician-authored cases from clinician oriented social media into structured training resources for medical multimodal LLM (Fig. 1a). ThoughtMed-1M is among the largest publicly available medical VQA resources, covering diverse diseases and imaging modalities and including clinically grounded reasoning and anatomical localization information (Fig. 1b and 1c). Unlike existing medical VQA datasets, ThoughtMed-1M explicitly embeds anatomical bounding boxes and stepwise clinical reasoning within its answers, providing structured supervision for image-text alignment, spatial grounding, and medical reasoning.
Building on this dataset, we developed a medical multimodal LLM, named FOLTMed, designed for medical image understanding and clinical reasoning (Fig. 1e). The proposed model is evaluated using diverse benchmark datasets, automated assessments, and clinician evaluations. FOLTMed demonstrated strong performance in medical image interpretation and reasoning, supporting the value of ThoughtMed-1M as a scalable resource for clinically grounded multimodal AI research. FOLTMed is intended as a research model for further methodological development and validation and, together with ThoughtMed-1M, it may help accelerate research in clinically grounded multimodal medical AI. Its potential clinical utility and workflow benefits remain to be established through further investigation by the research community, including blinded comparative reader studies and prospective clinical evaluations.
Taken together, this study principally contributes by (1) introducing ThoughtMed-1M, a large-scale, clinically grounded medical VQA dataset that provides structured supervision for medical image understanding, spatial grounding, image-text alignment, and clinical reasoning; (2) presenting FOLTMed, a medical multimodal LLM developed to demonstrate the utility of ThoughtMed-1M for model training and evaluated across diverse benchmark datasets and through clinician assessments; and (3) establishing a scalable end-to-end paradigm for transforming heterogeneous clinician-authored online cases into structured multimodal training data and subsequently leveraging these data for model development and evaluation. This paradigm provides a methodological foundation for future medical multimodal dataset construction and model development, while ThoughtMed-1M may facilitate the adaptation and systematic evaluation of clinically grounded medical multimodal LLM models.

a, Pipeline for data curation from online clinician-discussion platforms, VQA pair generation, and quality control. During quality control process, generated VQA pairs are categorized as correct, incorrect, or needing modification. For cases requiring modification, revisions are made by incorporating feedback from the highest-agreement preliminary model outputs, followed by a second round of LLM-based voting.
b, Distribution of VQA pairs across anatomical regions and organs in ThoughtMed-1M. c, Distribution of VQA pairs across different medical imaging modalities. d, Density plot comparing the answer length distributions of public medical VQA datasets used in this study (PMC-VQA, SLAKE, and VQA-RAD) and ThoughtMed-1M (VQA pairs generated from Radiopaedia and figure1.com cases), highlighting the substantially longer and more informative responses in the proposed dataset. e, Schematic illustration of the training process and example outputs of the FOLTMed model.
Fig. 1: Overview of dataset construction, characteristics, and model training.
Results
Case curation from social media and VQA pairs generation for ThoughtMed-1M
ThoughtMed-1M is derived from clinician-authored cases obtained from Radiopaedia and figure1.com, two large publicly accessible platforms for medical education and professional case discussion. The combined resulting corpus comprises 64,493 Radiopaedia cases containing 219,558 medical images and associated clinician-authored descriptions, together with 4,453 figure1.com discussion posts containing 7,671 images and accompanying clinical narratives. In total, the corpus included 227,229 publicly available medical images across 68,946 clinical cases.
By combining advanced LLMs to generate rigorous VQA pairs, followed by multiple rounds of quality control and filtering (details in Methods), the final ThoughtMed-1M dataset consists of 1,018,472 high-quality VQA pairs (the detailed generation workflow and sample counts at each stage are presented in Extended Data Fig. 1) that collectively cover the full human anatomy (Fig. 1b) and the broad spectrum of clinical imaging modalities (Fig. 1c). Each VQA pair incorporates image-specific clinical reasoning and anatomical grounding through embedded bounding-box annotations. Based on this dataset, we fine-tuned the SOTA model Gemma4-31B-PT as the base to obtain the FOLTMed model (Fig. 1e, as detailed in Methods).
Representative examples of curated clinical cases and generated VQA pairs are provided in Extended Data Fig. 2. Compared with existing corpora such as PMC-VQA, ThoughtMed-1M provides substantially richer clinical reasoning and more rigorous image-text alignment through bounding-box supervision (Fig. 1d).
Evaluation and Selection of LLMs for VQA Generation
To identify the optimal model for large-scale VQA generation, we compared four SOTA LLMs, ChatGPT 5.2, Claude Sonnet 4.5, Qwen3-VL-Max, and DeepSeek-V4, using clinician assessment, with all models accessed through their official APIs (as detailed in Methods). ChatGPT 5.2 achieved the highest overall mean score of 8.05 (95% CI: 7.95-8.15) (Fig. 2a). Claude Sonnet 4.5 scored slightly lower than ChatGPT 5.2, with an overall mean of 7.64 (95% CI: 7.53–7.75). In contrast, Qwen3-VL-Max and DeepSeek-V4 achieved lower overall mean scores of 6.87 and 6.41, respectively, suggesting comparatively weaker performance in our VQA generation setting. Based on these results, ChatGPT 5.2 was selected as the primary model for subsequent large-scale VQA generation.
To obtain finer-grained insights into model capabilities, we computed per-question and per-dimension mean scores. ChatGPT 5.2 consistently outperformed the other models across all metrics, with mean question-level scores ranging from 8.51 to 7.71 (Fig. 2b) and dimension-level means ranging from 8.34 to 7.75 (Fig. 2c).

Performance Comparison by Question
C
d
a–c, Overall and dimension-specific evaluations by clinical experts of VQA pairs generated from 20 clinical cases using ChatGPT 5.2 (n = 194), Claude Sonnet 4.5 (n = 200), Qwen3-VL-Max (n = 211) and DeepSeek-V4 (n=200). Here, n denotes the number of generated VQA pairs included in the evaluation; the numbers differed across models because each model generated a different number of valid VQA pairs for the selected cases. Individual VQA pairs were treated as the statistical unit, with clinician ratings aggregated at the VQA-pair level. Bars represent mean scores, and error bars indicate 95% confidence intervals. The overall mean scores aggregated across all evaluation questions are shown in a. b presents the mean scores for each of the eight individual questions, and c summarizes the mean scores across the four evaluation dimensions (overall quality, answer quality, clinical utility, and relevance & accuracy). d, Stacked bar chart illustrating the distribution of ChatGPT 5.2's scores across the four dimensions.
Fig. 2: Performance comparison of four LLMs in generating VQA pairs from curated cases.
In addition, the distribution of ChatGPT 5.2's ratings across the four evaluation dimensions is shown in Fig. 2d. Compared with the other LLMs (Extended Data Fig. 3), ChatGPT 5.2 exhibited a markedly higher concentration of ratings in the Excellent (9–10) and Good (7–8) categories across all dimensions, underscoring its consistently superior performance. Although a small proportion of generated VQA pairs received lower ratings in Clinical Utility and Relevance & Accuracy, most samples across all four dimensions received scores between 7 and 10. This distribution shows that ChatGPT 5.2-generated VQA pairs were generally rated favourably by clinicians across the four evaluation dimensions, providing additional support for its suitability as the initial model for large-scale VQA generation. Based on this clinician-led preliminary evaluation, ChatGPT 5.2 was identified as the most reliable model for generating high-quality VQA pairs, accordingly, it was selected as the LLM used to construct the ThoughtMed-1M dataset from curated clinical cases.
Evaluation of clinical accuracy across diverse medical multiple-choice VQA tasks
For evaluation of medical image understanding and clinical decision-making, We benchmarked FOLTMed against leading open-source (Gemma4-31B-IT, LLaMA3-70B, LLaVA-Med, and MedGemma-27B) and proprietary (Claude Sonnet 4.5 and ChatGPT 5.2) LLMs on the OmniMedVQA benchmark, which comprises 42 medical VQA datasets (Methods). As shown in Fig. 3a, FOLTMed achieved the best overall performance across all datasets (detailed dataset-level accuracies are provided in Supplementary Table 5), with a macro accuracy of 0.854 (median, 0.870; interquartile range (IQR), 0.129), representing an improvement of over 4% relative to the baseline Gemma4-31B-IT. FOLTMed also surpassed the strongest domain-specific model, MedGemma-27B (macro accuracy, 0.807; median, 0.844; IQR, 0.210), and demonstrated competitive performance compared with the leading proprietary model, ChatGPT-5.2 (macro accuracy, 0.824, median, 0.828; IQR, 0.165). Consistent trends were observed for micro accuracy (Fig. 3b), where FOLTMed achieved the highest performance (0.848), exceeding the second-best model, MedGemma-27B, by 2.6%. Further analysis across imaging modalities and question types showed that FOLTMed maintained consistently strong performance (Fig. 3c; Supplementary Tables 6 and 7). Across imaging modalities, FOLTMed achieved the highest micro accuracy in all categories except dermoscopy, where it was slightly lower than MedGemma-27B by approximately 2%. This difference may partly reflect the limited number of dermoscopy cases in ThoughtMed-1M (3,945 cases), highlighting data imbalance as a potential limitation and an important direction for future dataset expansion. Across question types, FOLTMed achieved the highest micro accuracy among all comparison models. Benefiting from the richer image descriptions and explicit bounding-box grounding provided by ThoughtMed-1M, FOLTMed showed a substantial advantage in anatomy identification, achieving an accuracy of 84.93%, which was 5.78% higher than the second-best model. These results highlight the robustness and generalizability of FOLTMed across heterogeneous clinical scenarios.

a, b, Overall performance comparison across 42 datasets using macro- and micro-accuracy, respectively, among FOLTMed and six SOTA models (Claude-Sonnet-4.5, Gemma31-IT, ChatGPT-5.2, LLaMA-70B, LLaVA-Med, and MedGemma-27B). c, Radar plot illustrating model performance across diverse medical imaging modalities and question types, highlighting differences in capability profiles between FOLTMed and competing approaches. d, Stacked bar chart showing the distribution of Top-7 model rankings across all datasets, reflecting the consistency and dominance of each model.
Fig. 3: Comprehensive evaluation of large language model performance across 42 medical datasets.
We further evaluated the consistency of model performance by analyzing the distribution of Top-7 rankings across all 42 datasets. FOLTMed demonstrates the best performance profile, achieving 17 first-place rankings and maintaining consistent representation across mid-tier (rank 2-3: 21 datasets) and lower top-tier positions (rank 4-5: 4 datasets). This represents a substantial improvement over the baseline Gemma4-31B-IT, which ranked first in only one dataset. MedGemma-27B achieved the second-highest number of first-place rankings (12 datasets); however, its performance was less consistently dominant, ranking only within positions 4-7 in 21 datasets. These results demonstrate that FOLTMed achieves consistently strong performance across diverse imaging modalities and question types, exhibiting superior robustness, the best ranking distribution, and improved generalizability across heterogeneous clinical scenarios compared with existing SOTA models.
Evaluation of reasoning ability and clinical utility of LLMs
We evaluated the open-ended response generation performance of FOLTMed on the ThoughtMed-1M test set using BERTScore, FActScore, and AlignScore (as detailed in Method). Compared with the same baseline models evaluated in the previous section, FOLTMed demonstrated superior factual reliability and logical consistency in clinical response generation (Fig. 4a). It achieved the highest performance across all three metrics, with BERTScore, FActScore, and AlignScore values of 0.66, 0.68, and 0.65, respectively. Among the comparison models, MedGemma-27B and ChatGPT-5.2 showed relatively competitive performance; however, their scores remained consistently lower than those of FOLTMed across all metrics, with gaps of approximately 0.03-0.05. These results indicate that FOLTMed more effectively generates responses that are semantically aligned with reference answers, factually supported by clinical evidence, and contextually consistent with the underlying case information. Further analysis across imaging modalities and question types showed that FOLTMed maintained strong performance in most evaluation categories (Fig. 4b; results for other models are shown in Extended Data Fig. 4). Across the majority of modalities and task types, its three metric scores were generally exceeded 0.65, suggesting stable open-ended reasoning performance across heterogeneous clinical scenarios. Notably, for diagnosis-related questions, FOLTMed achieved BERTScore, FActScore, and AlignScore values of 0.68, 0.77, and 0.74, respectively, highlighting its ability to generate clinically reliable diagnostic responses supported by relevant visual and contextual evidence. However, performance was relatively lower for the fluoroscopy modality and abnormality detection tasks, where FActScore and AlignScore decreased to below 0.60. This reduction reflect data imbalance and the relative scarcity of these categories in ThoughtMed-1M, suggesting that additional data curation and targeted training may be needed to further improve performance in underrepresented modalities and task types.

b
| Performance by modality for ThoughtMed | ||
|---|---|---|
| Angiography | 0.67 | 0.76 |
| Mammography | 0.66 | 0.75 |
| Other | 0.67 | 0.73 |
| Ultrasound | 0.66 | 0.71 |
| PET | 0.66 | 0.69 |
| X-ray | 0.67 | 0.67 |
| CT | 0.66 | 0.67 |
| MRI | 0.66 | 0.67 |
| Fluoroscopy | 0.67 | 0.56 |
| BERTScore | FactScore | AlignScore | |
|---|---|---|---|
| Angiography | 0.67 | 0.76 | 0.76 |
| Mammography | 0.66 | 0.75 | 0.72 |
| Other | 0.67 | 0.73 | 0.73 |
| Ultrasound | 0.66 | 0.71 | 0.68 |
| PET | 0.66 | 0.69 | 0.66 |
| X-ray | 0.67 | 0.67 | 0.65 |
| CT | 0.66 | 0.67 | 0.64 |
| MRI | 0.66 | 0.67 | 0.63 |
| Fluoroscopy | 0.67 | 0.56 | 0.53 |
| Performance by question type for ThoughtMed | ||
|---|---|---|
| Technical Assessment | 0.65 | 0.81 |
| Diagnosis | 0.68 | 0.77 |
| Reasoning | 0.68 | 0.75 |
| Pathophysiology | 0.66 | 0.70 |
| Report Generation | 0.62 | 0.69 |
| Localization | 0.67 | 0.67 |
| Normal Anatomy | 0.66 | 0.66 |
| Abnormality Detection | 0.65 | 0.57 |
| BERTScore | FactScore | |
| 0.80 | 0.74 | |
| 0.75 | 0.75 | |
| 0.70 | 0.66 | |
| 0.67 | 0.66 | |
| 0.63 | 0.53 | |
C
| Clinician evaluation for ThoughtMed | Strongly agree | Agree | Neutral | Disagree | Strongly disagree |
|---|---|---|---|---|---|
| 1. The model's diagnosis is clinically accurate. | |||||
| 2. The model identifies key imaging findings correctly. | |||||
| 3. The model's reasoning is clinically logical. | |||||
| 4. The model links visual evidence to its final answer. | |||||
| 5. The model's response is relevant and complete. | |||||
| 6. The model avoids unsupported or misleading claims. | |||||
| 7. The model can help doctors interpret clinical cases. | |||||
| 8. Willing to use the model as an auxiliary clinical tool. |

Question: This image belong to a 35-year-old male patient with multiple bony aches and pains, describe what you find in this image and find the reason for this symptom.
Ground-truth concepts: Primary hyperparathyroidism; brown tumor; expansile osteolytic lesion; light humeral head involvement; cortical thinning; hyperparathyroid bone disease.
Model Answer: This axial CT image of the upper chest shows a well-defined, expansile lytic lesion in the proximal humeral head/shoulder region, consistent with a brown tumor secondary to primary hyperparathyroidism. The lesion has a relatively low-attenuation center with cortical thinning, reflecting focal osteolytic bone resorption rather than a primary giant cell tumor. This appearance is compatible with the patient's systemic hyperparathyroid bone disease and can explain the bony aches and pain.
a, Overall performance comparison of semantic, factual, and contextual consistency across LLMs using BERTScore, FActScore, and AlignScore. b, Heatmap showing FOLTMed performance across diverse medical imaging modalities and question types. c, Clinician-based questionnaire ratings across multiple evaluation dimensions on 120 clinical cases, illustrating the quality and stability of FOLTMed responses.
d, Representative case example showing the correspondence between ground-truth clinical concepts and model-generated reasoning, with matched concepts highlighted.
Fig. 4: Evaluation of large language model performance on ThoughtMed-1M test set.
Clinician evaluation confirmed the strong clinical performance and practical utility of FOLTMed (as detailed in Methods). Across all assessed dimensions, FOLTMed received consistently high ratings, including for diagnostic accuracy, imaging finding recognition, reasoning consistency, response completeness, visual-textual grounding, and perceived clinical usefulness (Fig. 4c). These results suggest that FOLTMed's responses were not only factually reliable but also clinically interpretable and useful from the perspective of medical experts. A representative model output is shown in Fig. 4d (more example model output are provided in Supplementary Fig. 1), where FOLTMed correctly identified an expansile osteolytic lesion related to primary hyperparathyroidism and brown tumour formation, while explicitly grounding its answer in relevant image findings and clinical concepts. Overall, these findings demonstrate that FOLTMed provides semantically faithful, factually reliable, and contextually aligned clinical responses across diverse medical imaging tasks, while clinician-based evaluation further supports its potential as a clinically grounded auxiliary tool for medical image interpretation and reasoning.
Discussion
Large-scale annotated datasets have driven the rapid progress of computer vision, with ImageNet playing a pivotal role in shaping modern vision research. In the LLM era, the dependence on high-quality data has become even more pronounced—particularly in medicine, where VQA data for training generative medical LLMs remain scarce because their construction requires substantial domain expertise and years of clinical training. Medical LLMs have yet fully exploited publicly available clinician-oriented educational platforms and medical social media, which host extensive de-identified clinical cases and authentic discussions among clinicians. By leveraging these public resources together with advanced LLM-assisted generation and quality control, we constructed ThoughtMed-1M, a large-scale medical
VQA dataset comprising 1,018,472 high-quality VQA pairs with detailed clinical reasoning and anatomical annotations. ThoughtMed-1M was designed to support models in learning medical knowledge, structured reasoning processes, and explicit image-text alignment.
Based on this dataset, we fine-tuned the SOTA LLM Gemma4-31B-PT to develop FOLTMed. Unlike mainstream LLM research developed for narrow medical domains, FOLTMed is designed as a general medical LLM applicable to diverse imaging modalities and clinical question types. Across 42 datasets spanning multiple modalities and task categories, FOLTMed achieved superior performance compared with SOTA models, demonstrating strong generalizability in medical image understanding and clinical decision-making. Its substantial advantage in medical anatomy identification further suggests that ThoughtMed-1M effectively enhances image-text alignment and anatomically grounded visual reasoning. We further evaluated FOLTMed using the ThoughtMed-1M test set and clinician-based assessment to examine its medical reasoning ability, semantic completeness, and clinical applicability. Compared with SOTA models, FOLTMed demonstrated stronger semantic fidelity, factual precision, and contextual alignment across BERTScore, FActScore, and AlignScore (improvements of 3% – 5%). Clinician questionnaire-based evaluation further confirmed its clinical accuracy and practical utility, highlighting FOLTMed's potential as a broadly applicable foundation model for future medical AI research and clinically grounded deployment.
Despite these promising results, this study has several limitations. First, datasets curated from online resources may inevitably contain noise or errors, as reflected in the clinician-based evaluation of generated VQA pairs, where a small proportion of samples received relatively low scores (Fig. 2d). Although we applied rigorous filtering and multi-round quality control, such issues cannot be completely eliminated. Second, the collected data remain imbalanced across imaging modalities and disease categories, which may affect performance in underrepresented domains. For example, FOLTMed showed relatively weaker performance in dermoscopy, likely due to the limited number of dermoscopy VQA pairs in ThoughtMed-1M (3,945 VQA pairs from 741 cases), where its micro-accuracy was approximately 2% lower than that of MedGemma-27B. Nevertheless, its performance in this modality still exceeded that of most SOTA models, suggesting both practical potential and a clear direction for future dataset expansion. Third, although FOLTMed achieved strong promising performance across most modalities and question types, it did not reach perfect accuracy. Most task-level accuracies remained within the range of 80–90%, which is insufficient for use as an independent clinical diagnostic standard. Therefore, the proposed dataset and model should currently be viewed as a foundation for future research rather than a directly deployable clinical decision-making system. Fourth, the performance advantage of FOLTMed was mainly demonstrated against general medical LLMs and broadly applicable multimodal models. Task-specific models optimized for particular clinical domains may still outperform general-purpose models in their respective areas, such as SkinGPT-4 in dermatology. This suggests that further domain-specific fine-tuning may be necessary when applying FOLTMed to specialized clinical scenarios. Overall, the performance gains achieved by FOLTMed across diverse medical domains can be largely attributed to the carefully constructed ThoughtMed-1M dataset. Derived from publicly available clinician-authored clinical cases and discussions, ThoughtMed-1M provides high-quality VQA pairs that incorporate structured medical reasoning, diagnostic decision-making processes, and explicit image-text alignment through bounding-box grounding. To the best of our knowledge, ThoughtMed-1M represents the largest publicly available medical VQA dataset to date. We anticipate that the full open-source release of ThoughtMed-1M and FOLTMed will support the development of foundational medical LLMs and provide a scalable paradigm for future medical VQA dataset construction, and serve as a standardized benchmark to accelerate clinically grounded multimodal AI research.
Methods
ThoughtMed-1M dataset
Release policy
In accordance with the terms of use and licensing policies of Radiopaedia and figure1.com, all case information included in our dataset is referenced through persistent URLs directing users to the original case webpages. Because image URLs on these platforms are dynamically generated, we do not redistribute or directly provide the original image URLs. Instead, to ensure correct alignment between cases and VQA pairs, we supply code that programmatically retrieves the image URLs from the corresponding case webpages. Users who wish to access or download the original images must visit the source platforms and ensure that their intended use complies with the respective terms of use, licensing restrictions, and institutional or regulatory requirements. Our dataset includes the full set of generated question-answer pairs; details regarding these pairs and the associated case-level URLs are provided in the Data Availability section.
Radiopaedia cases collection
We collected all publicly accessible cases available on Radiopaedia from its launch in 2005 through 26 December 2025. Each case contains clinician-verified annotations including patient information, clinical presentation, imaging findings, and expert case discussions. These components were used as the factual grounding to support the generation of reliable VQA pairs based on clinically validated information. For image acquisition, although many radiology uploads on Radiopaedia originate from three-dimensional imaging studies, the first frame of each image series is consistently displayed using a clinically standardized plane selected by the contributing radiologist. In this study, because our dataset and model development focus on two-dimensional medical images, we extracted only the first frame from each image series and used it as the representative image for VQA pair generation.
figure1.com posts collection
To enable the model to capture authentic and diverse clinical reasoning signals that reflect real-world diagnostic workflows, we additionally collected clinician-generated posts from figure1.com, one of the largest global communities for healthcare professionals. Posts on this platform often contain multi-perspective clinical discussions and rare presentations, providing valuable context for training models to reason across complex and heterogeneous clinical scenarios. Under the guidance of clinical experts, we designed a set of 12 keywords covering a broad range of medical imaging modalities to retrieve relevant posts and maximize modality diversity (definitions in Supplementary Table 1). The complete set of keywords and their definitions is provided in Supplementary Table 1. Consistent with the Radiopaedia collection procedure, relevant posts and their associated discussions were collected between 2013 and 26 December 2025 using a predefined search strategy. The first 20 comments associated with each post were additionally retrieved to capture clinician discussions and diagnostic reasoning.
VQA pairs generation from clinical cases
To generate high-quality VQA pairs with strict image-text correspondence, clinical reliability, and educational value from the curated medical foundational corpus, we collaborated with clinical experts to design a comprehensive prompting framework and systematically evaluated several advanced LLMs to identify the most suitable model for VQA generation.
In designing the prompts, we required all the comparative LLMs to ground all generated questions and answers in factual case information, image-specific visual features, and clinically valid reasoning. The model was instructed to use only the clinical presentation, imaging report, and expert discussion provided for each case, together with the visible findings in the provided image. Because each case may contain multiple images, the LLM was strictly prohibited from referencing textual descriptions that did not correspond to the provided image or from fabricating any clinical or imaging details. When image-text correspondence was limited, the LLM was required to rely on purely image-based observations and generate simpler questions such as anatomical identification, basic structural analysis, or abnormality screening, thereby avoiding cross-image contamination. To further encourage clinically meaningful reasoning, the answer-generation prompt required the LLMs to emulate expert radiologist reasoning grounded in clinician-verified case information. This included step-wise diagnostic logic, integration of image findings with clinical context and medical knowledge, and multi-source verification of key observations. The LLM was also required to provide precise spatial descriptions and selective bounding-box annotations to explicitly link textual explanations to specific visual evidence. All outputs were mandated to be fully traceable, image-specific, and free of hallucinated content. To ensure diversity and pedagogical richness, the LLM was instructed to generate multiple types of questions, including observational, analytical, diagnostic, symptom-imaging correlation, and multi-step chain-of-reasoning questions. A structured radiological report could be generated only when the case information and visible findings were sufficiently complete. This prompting framework ensured that the resulting ThoughtMed-1M VQA pairs exhibit high factual fidelity, strong image-text alignment, and clinically meaningful reasoning depth. Full prompts for all LLM-based generation, refinement, and evaluation stages are provided in Supplementary Table 2 and Note 1.
To identify the most suitable LLM for generating high-quality VQA pairs from collected medical cases, we collaborated with clinical experts to design a set of multi-perspective prompts. Four SOTA LLMs, ChatGPT 5.2, Claude Sonnet 4.5, Qwen3-VL-Max and DeepSeek-V4 were evaluated using their official APIs and provided with the same system instruction, case-level clinical information, imaging report, clinical discussion, and individual medical image. Generation settings were harmonized across models, using a temperature of 0.7, a maximum output length of 8,192 tokens, and a shared prompt requiring image-specific, clinically grounded VQA pairs with structured answers, reasoning, and anatomical localization information. All subsequent commercial LLM calls in this study were conducted using these same parameter settings. These models represent leading commercially available LLMs with extensive medical knowledge and strong clinical-reasoning capabilities . From the curated corpus, we selected 20 representative cases spanning multiple radiological imaging modalities. Each of the four LLMs was prompted using the same case information and standardized prompt framework, generating approximately 200 VQA pairs per model for evaluation. Ten radiology clinicians from Guang'anmen Hospital independently assessed the generated outputs using an eight-item evaluation instrument mapped to four key dimensions: overall quality, answer quality, clinical utility, and relevance and accuracy (Supplementary Table 3). For each generated VQA pair, clinicians assigned scores on a 10-point scale across all eight items. This process enabled a multi-dimensional comparison of the models' capability to generate clinically coherent and image-faithful VQA pairs, allowing us to identify the most suitable model for subsequent large-scale data generation.
Using the selected LLM and the clinician-designed prompting framework, we then generated the large-scale VQA corpus that constitutes the foundation of ThoughtMed-1M, based on the medical cases collected from Radiopaedia and figure1.com.
Quality control of the ThoughtMed-1M dataset
To ensure the factual reliability and clinical validity of all generated VQA pairs, we implemented a multi-stage quality control pipeline combining medically specialized LLM refinement and cross-model verification. First, every VQA pair was reviewed using the medically specialised LLM MedGemma-27B-VL, which refined the questions and answers based on the clinician-verified case information to enhance factual grounding, clinical coherence, and diagnostic accuracy. The prompts used for MedGemma-27B-VL and the three voting models are provided in Supplementary Table 2.
Following refinement, we applied a consensus-based quality voting procedure using three advanced LLMs: Claude Sonnet 4.5, ChatGPT 5.2, and DeepSeek V4. Each model independently evaluated whether a VQA pair met the required standards of factual correctness, clinical reasoning validity, and diagnostic appropriateness. A VQA pair was retained only if all three models unanimously judged it to be acceptable across these criteria. Meantime, pairs failing to achieve full consensus were discarded.
Through this rigorous refinement and selection pipeline, only high-quality VQA pairs with stable factual grounding and clinically reliable reasoning were preserved in the final ThoughtMed-1M dataset.
Model construction and training strategy
We developed FOLTMed based on the MiniGPT-4 LLM training framework described by Chen et al. , adopting Gemma4-31B-PT as the foundational multimodal backbone. In contrast to instruction-tuned(IT) Gemma4 variants, we initialize FOLTMed from the pretrained (PT) model to enable domain-specific adaptation through subsequent medical training. For fair comparison, the instruction-tuned counterpart, Gemma4-31B-IT, is used as the baseline model in all experiments. Model training was conducted using full-parameter fine-tuning, in which all trainable parameters of the multimodal backbone were updated during medical domain adaptation. This strategy was used to maximize the model's capacity to absorb large-scale medical vision-language knowledge from ThoughtMed-1M and to better adapt to complex medical VQA tasks involving clinical reasoning, image-text alignment and spatial grounding. The workflow of FOLTMed model construction and training process is shown in Extended Data Fig. 5.
Domain-Adaptive Pre-training for basic medical knowledge learning
To enhance the model's foundational biomedical knowledge, clinical language competence, and medical reasoning capability, we performed Domain-Adaptive Pre-training (DAPT) on two large-scale textual corpora in a sequentially: the Medical Domain Corpus and the MIMIC-III Clinical Database .
Specifically, Medical Domain Corpus is a comprehensive biomedical text collection containing medical encyclopedic entries, disease overviews, treatment descriptions, explanations of biomedical concepts, and clinically oriented narratives. Its broad terminology coverage, structured writing style, and clear factual descriptions make it well suited for establishing the model's initial medical conceptual framework, enabling early adaptation from general-domain linguistic distributions to biomedical discourse. Accordingly, this corpus was used for the first stage of DAPT. We then conducted a second-stage DAPT using the MIMIC-III Clinical Database, a large repository of real intensive-care clinical notes that includes discharge summaries, progress notes, nursing documentation, diagnostic reports, and physician orders. MIMIC-III remains one of the most widely adopted corpora for clinical language modeling and domain-adaptive pretraining of medical LLMs, and has been used by numerous recent foundation medical models. Compared with MIMIC-IV, the linguistic characteristics relevant to DAPT, including discharge summaries, progress notes, and clinician-authored documentation, are largely preserved, making MIMIC-III a suitable resource for learning clinical language patterns and reasoning processes. Given that the objective of this stage was to acquire general clinical language and reasoning knowledge rather than perform temporal or structured EHR prediction tasks, MIMIC-III provided sufficient coverage for domain adaptation. Unlike the more structured biomedical corpus, these texts more closely resemble real-world clinical communication, characterized by unstructured formats, dense clinical abbreviations, and context-dependent reasoning. Training on this dataset further exposes the model to authentic clinical language patterns, information organization, and multi-step diagnostic logic, thereby strengthening its ability to perform context-aware medical reasoning.
During DAPT, the model was trained using the causal language modeling (CLM) objective . Given a corpus where each biomedical or clinical document is represented as a token sequence , the model learns to predict each token based on its preceding context, minimizing the negative log-likelihood
This training objective enables the model to learning domain-specific linguistic structures, clinical terminology, and reasoning conventions, thereby aligning its representation space with biomedical and real-world clinical text.
Two-stage Supervised Fine-tuning (SFT) for medical VQA task
To equip the model with task-aware reasoning and medical question-answering capabilities, we performed Supervised Fine-tuning (SFT) in two stages. In the first stage, FOLTMed was trained on the training subsets of three widely used medical VQA datasets: PMC-VQA , SLAKE , and VQA-RAD . These datasets contain well-structured, short-answer VQA samples that cover essential tasks such as anatomical identification, radiological description, and lesion recognition. Training on these datasets enables the model to acquire fundamental medical VQA patterns, including common question formulations, domain-specific terminologies, and basic image-text correspondences, thereby establishing a solid foundation for higher-level clinical reasoning.
In the second stage, we further refined the model using the proposed ThoughtMed-1M dataset to strengthen its advanced reasoning capabilities in clinically realistic environments. ThoughtMed-1M encompasses a broad spectrum of imaging modalities, complex clinical narratives, and a large number of expert-guided VQA pairs. Its content extends beyond basic disease identification, capturing symptom-imaging associations, multi-step diagnostic reasoning, spatial localization, and clinically grounded integrative judgments. Compared with existing public medical VQA datasets, ThoughtMed-1M provides substantially higher factual density, deeper reasoning structure, and more rigorous image-text alignment. SFT on this dataset enables the model to internalize reasoning patterns that are more closely aligned with real clinical practice, markedly enhancing its applicability to authentic diagnostic scenarios.
Although SFT also adopts the CLM objective, its training formulation fundamentally differs from the text-only DAPT stage. Whereas DAPT applies autoregressive modeling to continuous text sequences, SFT constructs multimodal VQA training instances in which the model generates answers conditioned jointly on the instruction prompt, structured clinical information, and image embeddings produced by the visual encoder. Each target answer sequence is appended with an explicit end-of-sequence symbol EOS to standardize output structure, formally denoted as where T is the sequence length. Padding tokens are masked by setting their target values to -100 (i.e., for padding positions, where represents the target token at position i) to restrict optimization to semantically meaningful regions. Through this task-aligned multimodal SFT strategy, FOLTMed learns task-specific reasoning patterns, image-text alignment mechanisms, and clinically oriented decision logic, thereby achieving substantially improved performance on real-world medical VQA tasks.
Reinforcement fine-tuning (RFT) for VQA output enhancement
Although SFT substantially improves the model's medical reasoning ability, the complexity of the ThoughtMed-1M cases and their multi-step diagnostic chains revealed persistent limitations: the model trained on DAPT and SFT often failed to cover all essential clinical concepts and frequently produced inaccurate or incomplete bounding boxes. To further enhance clinical reasoning consistency and spatial localization accuracy, we introduced a RFT stage following SFT.
RFT was implemented using Group Relative Policy Optimization (GRPO) . For each input query , the current policy generates a group of candidate responses , and a reward is computed for each response. GRPO constructs a group-wise relative advantage , where measures the quality of response relative to its peers. Model parameters are updated by minimizing the following loss:
Responses with increase their likelihood under the policy, whereas lower-quality responses are suppressed. This group-relative formulation avoids scale-sensitivity issues in reward magnitudes and enables stable convergence toward clinically coherent reasoning behaviors.
To translate the essential requirements of medical VQA into optimizable objectives, we designed three complementary reward components targeting spatial localization accuracy, medical-concept completeness, and output quality. (1) Bounding-box reward. This component evaluates the Intersection-over-Union (IoU) between predicted and reference bounding boxes. A soft linear mapping converts IoU values to a reward in via , so that yields -0.5, yields 0, and yields +1.0. When the reference contains no annotated lesion, extra predicted boxes are penalized with a sublinear coefficient (proportional to ) to suppress hallucinated detections without driving reward saturation. When the reference contains lesions but the model predicts none, a mild fixed penalty of -0.2 is applied. (2) Alignment reward. To ensure comprehensive and accurate medical-concept expression, we measure the coverage of key clinical concepts (e.g., symptoms, imaging findings, diagnostic cues) provided in the dataset. A concept is considered covered if at least 70% of its constituent tokens appear in the generated answer. Coverage score is mapped to a reward in [-1, 1], where missing concepts are penalized proportionally. A repetition penalty (weight 0.3) discourages token and bigram redundancy, preventing inflated coverage through trivial repetition. (3) Format reward. Since the training data do not employ explicit uncertainty tags, the calibration component was replaced by a format and quality reward that promotes well-structured, clinically informative responses. It penalizes near-empty outputs (fewer than 5 words, -0.6) and overly short responses (fewer than 20 words, -0.2), rewards answers in the appropriate length range of 20–300 words (+0.3), and penalizes excessively long or repetitive outputs. Pathological repetition is detected through trigram loop analysis and consecutive duplicate sentence detection. Additionally, a small bonus or penalty is applied based on whether the model's bounding-box predictions are consistent with the reference (+0.1 if both include a box, -0.15 if the model omits a box when the reference contains one). The three rewards are combined with weights of 0.3, 0.5, and 0.2, respectively.
The final reward is obtained by a weighted combination of the three components. Optimizing the model with GRPO under this composite reward enables FOLTMed to improve spatial localization accuracy and enhance completeness and correctness of clinical reasoning, ultimately reducing hallucination and substantially strengthening model robustness in complex medical VQA scenarios.
Model validation
For the evaluation of FOLTMed and baseline LLMs in terms of clinical decision accuracy and assistant utility, we conducted a comprehensive assessment combining accuracy-based evaluation, automated semantic and factual consistency evaluation, and clinician judgment-based evaluation to comprehensively assess model performance from objective and practical perspectives. The accuracy-based evaluation focuses on the model's ability to produce correct clinical answers under standardized benchmarks, while the clinician-based evaluation assesses the usefulness, reliability, and reasoning quality of model responses in clinical scenarios.
For accuracy-based evaluation, we benchmarked FOLTMed on the open-access subset of OmniMedVQA , currently the largest closed-ended medical multiple-choice VQA benchmark.
OmniMedVQA comprises 42 sub-datasets spanning diverse imaging modalities, disease categories, and question types, providing a comprehensive testbed for evaluating multimodal medical reasoning. We compared FOLTMed against representative SOTA LLMs, including open-source models (Gemma4-31B-IT , LLaMA3-70B , LLaVA-Med , and MedGemma-27B ) and proprietary models (Claude-Sonnet-4.5 and ChatGPT-5.2 ). These models collectively represent leading approaches across domain-specific medical LLMs (MedGemma-27B, LLaVA-Med), general-purpose open-source LLMs (Gemma4-31B-IT, LLaMA3-70B), and commercial systems (Claude-Sonnet-4.5, ChatGPT-5.2) (LLM information as detailed in Supplementary Table 4). Gemma4-31B-IT was used as the baseline model for direct comparison. Open-source models were evaluated using their official pretrained weights, whereas proprietary models were accessed via their respective APIs in accordance with official documentation. All models were assessed using multiple-choice accuracy as the primary evaluation metric.
For the automated semantic and factual consistency evaluation, we used both standardized public medical VQA benchmarks and newly curated clinical cases. In addition to public benchmark datasets, model-generated responses were evaluated on 120 multimodal clinical cases curated from Radiopaedia from 1 March 2026 to 1 May 2026. These cases were selected to ensure broad coverage of imaging modalities, anatomical regions, and clinical conditions. To ensure methodological consistency with the construction of ThoughtMed-1M, questions for these Radiopaedia cases were generated using the same VQA generation protocol as described for the main dataset. This process yielded a total of 2,158 VQA pairs from the 120 cases. For each VQA pair, the evaluated models generated responses based on the corresponding medical image and question. The generated responses were then assessed against the reference answers and associated clinical evidence using BERTScore, FActScore, and AlignScore, which were used to quantify semantic similarity, factual precision, and contextual alignment, respectively.
For clinician judgment-based evaluation, the same 120 Radiopaedia clinical cases were used to assess model performance in realistic clinical decision-making scenarios. A total of 10 experienced clinicians from Guang'anmen Hospital participated in a questionnaire-based evaluation. For each case, clinicians engaged in multi-round question-answering with each model to simulate real-world clinical interactions and assess the quality of model responses in a clinically meaningful context. Clinicians rated the model outputs across multiple dimensions, including clinical accuracy, relevance, reasoning quality, completeness, and practical utility (definitions provided in Supplementary Table 8). Together, the automated and clinician-based evaluations provided a comprehensive assessment of model performance across both standardized benchmark settings and real-world clinical scenarios.
Statistical information
Macro- and micro-accuracy were used to evaluate model performance in closed-ended clinical decision-making tasks on OmniMedVQA dataset. For the automated evaluation of semantic and factual consistency, we computed BERTScore, FActScore, and AlignScore to assess model-generated responses against reference answers and the corresponding clinical evidence extracted from the curated Radiopaedia cases. BERTScore was calculated using the bert-base-uncased model to quantify semantic similarity. FActScore and AlignScore were used to assess factual precision and contextual alignment, respectively, with ChatGPT-5.2 serving as the evaluator model. For clinician judgment-based evaluation, model responses were rated on a 0–10 scale across multiple dimensions, including clinical accuracy, relevance, reasoning quality, completeness, and practical utility. Mean scores and standard errors were reported for each evaluation dimension. To estimate rating uncertainty and distributional variability, 95% confidence intervals and interquartile ranges were calculated using bootstrap resampling.
Data Availability
During peer review, the generated QA pairs are available to editors and reviewers through a private Figshare link. To comply with the terms of use and licensing policies of Radiopaedia and figure1.com, the original medical images and cases\posts content are not redistributed. Upon acceptance, the complete ThoughtMed-1M dataset, including the generated VQA pairs and corresponding source-case URLs, will be released through Figshare platform. The repository is currently private and will be made publicly accessible upon publication. Users are responsible for ensuring that their use of the original images complies with the terms of use, licensing restrictions, and applicable institutional or regulatory requirements of Radiopaedia and figure1.com.
All other datasets used in this study are publicly available and can be accessed from the following sources: PMC-VQA, https://huggingface.co/datasets/RadGenome/PMC-VQA; SLAKE, https://www.med-vqa.com/slake/; VQA-RAD, https://huggingface.co/datasets/flaviagiammarino/vqa-rad; Medical Domain Corpus, https://www.kaggle.com/datasets/aunanya875/medical-domain-corpus; MIMIC-III Clinical Database, https://physionet.org/content/mimiciii/1.4/; and OmniMedVQA, https://huggingface.co/datasets/foreverbeliever/OmniMedVQA. The open-access subset of OmniMedVQA used in this study includes all 42 validation datasets evaluated in our experiments.
Code Availability
The source code and model weights for FOLTMed can be accessed at https://github.com/2739794696/ThoughtMed. The code is currently maintained in a private repository but will be made available to editors and reviewers upon request during peer review and publicly released upon acceptance.
References
-
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K. & Fei-Fei, L. Imagenet: A large-scale hierarchical image database. in 2009 IEEE conference on computer vision and pattern recognition 248–255 (Ieee, 2009).
-
Li, J., Yang, Y., Bai, Y., Zhou, X., Li, Y., Sun, H., Liu, Y., Si, X., Ye, Y. & Wu, Y. Fundamental capabilities of large language models and their applications in domain scenarios: A survey. in Proceedings of the 62nd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers) 11116–11141 (2024).
-
Lin, H., Wang, X., Yan, R., Huang, B., Ye, H., Zhu, J., Wang, Z., Zou, J., Ma, J. & Liang, Y. Generative evaluation of complex reasoning in large language models. arXiv preprint arXiv:2504.02810 (2025).
-
Deepak, G.D. & Bhat, S.K. A multi-stage deep learning approach for comprehensive lung disease classification from x-ray images. Expert Systems with Applications 277, 127220 (2025).
-
Lu, M.Y., Chen, B., Williamson, D.F., Chen, R.J., Liang, I., Ding, T., Jaume, G., Odintsov, I., Le, L.P. & Gerber, G. A visual-language foundation model for computational pathology. Nature medicine 30, 863–874 (2024).
-
Sellergren, A., Kazemzadeh, S., Jaroensri, T., Kiraly, A., Traverse, M., Kohlberger, T., Xu, S., Jamil, F., Hughes, C. & Lau, C. Medgemma technical report. arXiv preprint arXiv:2507.05201 (2025).
-
Dong, W., Ge, J., Dong, W. & Motani, M. LLaMA32-Med: Parameter-Efficient Adaptation of Multimodal LLMs for Medical Visual Question Answering. in Medical Imaging with Deep Learning (2026).
-
Zhou, J., He, X., Sun, L., Xu, J., Chen, X., Chu, Y., Zhou, L., Liao, X., Zhang, B. & Afvari, S. Pre-trained multimodal large language model enhances dermatological diagnosis using SkinGPT-4. Nature Communications 15, 5649 (2024).
-
Shmatko, A., Jung, A.W., Gaurav, K., Brunak, S., Mortensen, L.H., Birney, E., Fitzgerald, T. & Gerstung, M. Learning the natural history of human disease with generative transformers. Nature, 1–9 (2025).
-
Andersson, H., Hansen, B. & Wassélius, J. Commercial AI Model Diagnostic Accuracy for Intracranial Large-and Medium-Vessel Occlusion at Emergency CT Angiography. Radiology: Artificial Intelligence 8, e250749 (2026).
-
Bentegeac, R., Le Guellec, B., Maanaoui, M., Gerard, E., Amouyel, P., Cheungpasitporn, W., Florens, N. & Hamroun, A. Randomized Controlled Trial of LLM-Assisted Diagnostic Accuracy in Nephrology. Kidney International Reports, 106673 (2026).
-
Zhang, X., Wu, C., Zhao, Z., Lin, W., Zhang, Y., Wang, Y. & Xie, W. Pmc-vqa: Visual instruction tuning for medical visual question answering. arXiv preprint arXiv:2305.10415 (2023).
-
Liu, B., Zhan, L.-M., Xu, L., Ma, L., Yang, Y. & Wu, X.-M. Slake: A semantically-labeled knowledge-enhanced dataset for medical visual question answering. in 2021 IEEE 18th international symposium on biomedical imaging (ISBI) 1650–1654 (IEEE, 2021).
-
Lau, J.J., Gayen, S., Ben Abacha, A. & Demner-Fushman, D. A dataset of clinically generated visual questions and answers about radiology images. Scientific data 5, 1–10 (2018).
-
Hu, X., Gu, L., Kobayashi, K., Liu, L., Zhang, M., Harada, T., Summers, R.M. & Zhu, Y. Interpretable medical image visual question answering via multi-modal relationship graph learning. Medical Image Analysis 97, 103279 (2024).
-
Hu, X., Gu, L., An, Q., Zhang, M., Liu, L., Kobayashi, K., Harada, T., Summers, R. & Zhu, Y. Medicaldiff-vqa: a large-scale medical dataset for difference visual question answering on chest x-ray images. PhysioNet 12, 13 (2023).
-
Seenivasan, L., Islam, M., Krishna, A.K. & Ren, H. Surgical-vqa: Visual question answering in surgical scenes using transformer. in International Conference on Medical Image Computing and Computer-Assisted Intervention 33–43 (Springer, 2022).
-
Laurie, S., Steyaert, W., De Boer, E., Polavarapu, K., Schuermans, N., Sommer, A.K., Demidov, G., Ellwanger, K., Paramonov, I. & Thomas, C. Genomic reanalysis of a pan-European rare-disease resource yields new diagnoses. Nature medicine 31, 478–489 (2025).
-
Svinin, G., Loo, R.T.J., Soudy, M., Nasta, F., Le Bars, S. & Glaab, E. Computational Systems Biology Methods for Cross-Disease Comparison of Omics Data. Wiley Interdisciplinary Reviews: Computational Molecular Science 15, e70042 (2025).
-
Dai, D., Zhang, Y., Xu, L., Yang, Q., Shen, X., Xia, S. & Wang, G. Pa-llava: A large language-vision assistant for human pathology image understanding. in 2024 IEEE International Conference on Bioinformatics and Biomedicine (BIBM) 3138–3143 (IEEE, 2024).
-
Huang, Z., Bianchi, F., Yuksekgonul, M., Montine, T.J. & Zou, J. A visual-language foundation model for pathology image analysis using medical twitter. Nature medicine 29, 2307–2316 (2023).
-
Anderson, T., Gillman, J. & Pantel, A. Radiopaedia. org case playlists to increase trainee access to teaching file cases. (Society of Nuclear Medicine, 2020).
-
Gaillard, F. Radiopaedia: building an online radiology resource. (European Congress of Radiology-RANZCR ASM 2011, 2011).
-
Liu, R., Gupta, S. & Patel, P. The application of the principles of responsible AI on social media marketing for digital health. Information Systems Frontiers 25, 2275–2299 (2023).
-
Singhal, A., Neveditsin, N., Tanveer, H. & Mago, V. Toward fairness, accountability, transparency, and ethics in AI for social media and health care: scoping review. JMIR Medical Informatics 12, e50048 (2024).
-
Owen, D., Lynham, A.J., Smart, S.E., Pardiñas, A.F. & Camacho Collados, J. Ai for analyzing mental health disorders among social media users: Quarter-century narrative review of progress and challenges. Journal of Medical Internet Research 26, e59225 (2024).
-
Wang, Q., Zou, H., Zhang, H., Huang, Y., Tian, J. & Cheng, W. A Survey on Medical Competence Evaluation Benchmarks for Large Language Models. Health Care Science (2026).
-
Chen, J., Zhu, D., Shen, X., Li, X., Liu, Z., Zhang, P., Krishnamoorthi, R., Chandra, V., Xiong, Y. & Elhoseiny, M. Minigpt-v2: large language model as a unified interface for vision-language multi-task learning. arXiv preprint arXiv:2310.09478 (2023).
-
Mahmud, S.A. Medical Domain Corpus, (Kaggle, 2025).
-
Johnson, A., Pollard, T. & Mark, R. MIMIC-III Clinical Database, (PhysioNet, 2016).
-
Radford, A., Narasimhan, K., Salimans, T. & Sutskever, I. Improving language understanding by generative pre-training. (2018).
-
Shao, Z., Wang, P., Zhu, Q., Xu, R., Song, J., Bi, X., Zhang, H., Zhang, M., Li, Y. & Wu, Y. Deepseekmath: Pushing the limits of mathematical reasoning in open language models. arXiv preprint arXiv:2402.03300 (2024).
-
Hu, Y., Li, T., Lu, Q., Shao, W., He, J., Qiao, Y. & Luo, P. Omnimedvqa: A new large-scale comprehensive evaluation benchmark for medical lvlm. in Proceedings of the
IEEE/CVF Conference on Computer Vision and Pattern Recognition 22170–22183 (2024).
-
Team, G., Mesnard, T., Hardin, C., Dadashi, R., Bhupatiraju, S., Pathak, S., Sifre, L., Rivière, M., Kale, M.S. & Love, J. Gemma: Open models based on gemini research and technology. arXiv preprint arXiv:2403.08295 (2024).
-
Grattafori, A., Dubey, A., Jauhri, A., Pandey, A., Kadian, A., Al-Dahle, A., Letman, A., Mathur, A., Schelten, A. & Vaughan, A. The llama 3 herd of models. arXiv preprint arXiv:2407.21783 (2024).
-
Li, C., Wong, C., Zhang, S., Usuyama, N., Liu, H., Yang, J., Naumann, T., Poon, H. & Gao, J. Llava-med: Training a large language-and-vision assistant for biomedicine in one day. Advances in Neural Information Processing Systems 36, 28541–28564 (2023).
-
Bai, Y., Kadavath, S., Kundu, S., Askell, A., Kernion, J., Jones, A., Chen, A., Goldie, A., Mirhoseini, A. & McKinnon, C. Constitutional ai: Harmlessness from ai feedback. arXiv preprint arXiv:2212.08073 (2022).
-
Singh, A., Fry, A., Perelman, A., Tart, A., Ganesh, A., El-Kishky, A., McLaughlin, A., Low, A., Ostrow, A. & Ananthram, A. Openai gpt-5 system card. arXiv preprint arXiv:2601.03267 (2025).
Acknowledgements
This work was supported in part by the National Natural Science Foundation of China (No.62406211), the Natural Science Foundation of Sichuan Province (No.2024NSFSC0654). We gratefully acknowledge the Sichuan University Biomedical Engineering Experimental Teaching Center (Chengdu, China) and the New Zealand eScience Infrastructure for their invaluable support and access to advanced research facilities. We also gratefully acknowledge Radiopaedia and figure1.com for providing valuable clinical and educational resources for the non-commercial academic research conducted in this study. We are particularly grateful to Professor Colin Simpson (University of Auckland) for his thoughtful review of the manuscript and for the insightful and constructive feedback that helped strengthen both the scientific presentation and interpretation of this work.
Ethics declarations
This study used de-identified clinical data obtained from publicly available online sources and involved clinicians as anonymous participants in the evaluation of the dataset and model-generated outputs. The study protocol was approved by the Institutional Review Board of Guang'anmen Hospital, China Academy of Chinese Medical Sciences (approval no. 2026-031-KY).
Competing interests
The authors declare no competing interests.
Extended data
a

b

a, Flowchart of data curation, VQA pair generation, refinement, and voting-based selection for the ThoughtMed-1M training set using Radiopaedia cases and figure1.com discussion posts collected up to 26 December 2025. b, Flowchart of Radiopaedia case curation and VQA pair generation for the ThoughtMed-1M test set, based on cases collected from 1 March to 1 May 2026.
Extended Data Fig. 1. Data curation and VQA pair generation flow for the ThoughtMed-1M training and test sets.
Cases infomation (from Radiopaedia, URL: https://radiopaedia.org/cases/radiation-enteritis-with-small-bowel-obstruction)
Presentation: Nausea and vomiting
Report: Long segment terminal ileum stricture with luminal narrowing and wall thickening/irregularity, nearly leading into the ileocaecal valve. Upstream segmental small bowel dilation and faecalisation without high grade obstruction. Small ascites. Hysterectomy. Sacrum is relatively demineralised due to radiation.
Discussion: Typical appearance of chronic radiation enteritis leading to stricture and partial small bowel obstruction. The stricture can have a variety of appearances, and is related to chronic ischaemia (endarteritis obliterans) in the setting of vascular injury in the radiation field. Even if you do not have the corresponding clinical history, if you see an absent uterus and demineralised (more lucent) appearance of the sacrum and lower lumbar spine, you can suspect this diagnosis.
Q: Identify the transition between dilated and more normal-caliber bowel loops in this slice. Where is this transition zone located, and how does it help localize the level of obstruction?

A: The transition between the more dilated small bowel and the relatively normal-caliber loops is seen in the right mid-abdomen [177,201,243,253]. In this region, the bowel caliber decreases, and the loops appear more collapsed with less intraluminal gas and particulate material compared to the dilated loops on the left and central abdomen [186,125,450,198]. This change in caliber and content suggests that the obstruction is distal to the dilated loops and near this right-sided region, consistent with a transition toward the terminal ileum and ileocaecal area. Localizing this transition zone is key in identifying the approximate level of obstruction in partial small bowel obstruction.
Q: Given the patient's nausea and vomiting, which specific bowel findings on this CT image could explain these symptoms, and how do they support a diagnosis of partial small bowel obstruction?

A: The patient's nausea and vomiting can be explained by the dilated small bowel loops in the mid to right abdomen [110,183,216,323], which indicate impaired downstream transit. These loops are wider and more fluid/gas-filled compared with the relatively narrower distal bowel segments in the right lower quadrant [206,313,327,404]. This pattern of upstream dilatation with a more collapsed distal segment is typical of a partial small bowel obstruction rather than a diffuse ileus. In the context of the known terminal ileal stricture from chronic radiation enteritis, these imaging features provide a direct structural cause for her obstructive gastrointestinal symptoms.
Representative clinician-authored case from Radiopaedia illustrating the construction of ThoughtMed-1M. The original presentation, imaging report and expert discussion were used as clinical grounding to generate VQA pairs that capture image findings, diagnostic reasoning and symptom-imaging associations. Generated answers include bounding-box annotations that explicitly link textual reasoning to relevant image regions, demonstrating the image-grounded and clinically structured nature of the proposed VQA dataset.
Extended Data Fig. 2 Example of curated clinical cases and generated VQA pairs.

b
C
Stacked bar charts showing clinician-assigned rating distributions for VQA pairs generated by a, Claude-Sonnet-4.5, b, Qwen3-VL-Max and c, DeepSeek-V4 across four evaluation dimensions: overall quality, answer quality, clinical utility, and relevance and accuracy, providing complementary evidence for the selection of the final LLM used to construct ThoughtMed-1M.
Extended Data Fig. 3. Distribution of clinician ratings for VQA pairs generated by Claude-Sonnet-4.5, Qwen3-VL-Max and DeepSeek-V4.

Heatmaps showing the performance of six comparison models across medical imaging modalities and clinical question types using BERTScore, FActScore and AlignScore. a–f, Results for MedGemma-27B, ChatGPT-5.2, Claude-Sonnet-4.5, Gemma-4-31B-IT, LLaMA3-70B and LLaVA-Med, respectively. For each model, the left heatmap summarizes performance across imaging modalities, and the right heatmap summarizes performance across question types.
Extended Data Fig. 4. Modality- and task-specific semantic, factual and contextual consistency of baseline LLMs.

The workflow illustrates the construction of FOLTMed from the Gemma4-31B-PT multimodal backbone, followed by sequential DAPT, two-stage SFT and GRPO. DAPT was performed using biomedical and clinical text corpora to establish domain-specific language and reasoning capabilities. SFT was conducted first on public medical VQA datasets and then on ThoughtMed-1M to enhance multimodal question answering, image-text alignment and clinically grounded reasoning. Finally, GRPO-based reinforcement fine-tuning was applied with bounding-box, alignment and format rewards to improve spatial grounding, concept coverage and response quality.
Extended Data Fig. 5. Workflow of FOLTMed model construction and multimodal medical training strategy.
Supplementary Information