Manuscript Offprint

arXiv:2609.07244

Towards a Resilience-Theoretic Foundation for Adversarial Robustness in Industrial Control System Anomaly Detection

Branka Stojanović, Andreas Flatscher, Michael Somma

Abstract

Anomaly-based intrusion detection systems in industrial control systems (ICS) and operational technology (OT) environments are increasingly required to meet formal resilience criteria: absorbed adversarial disturbances, graceful degradation under sustained attack, and certified system-level guarantees. Existing resilience frameworks for cyber-physical systems define absorb-recover-adapt trajectories at the architectural level but do not treat machine learning anomaly detectors as first-class components, leaving a gap between component-level robustness evaluation and system-level resilience certification.

In this paper, we establish that adversarial robustness in ICS anomaly detection is a specific instantiation of system resilience, and formalise this connection by mapping four resilience constructs, i.e. disturbance class, absorption capacity, recovery trajectory, and degradation function, onto the adversarial machine learning setting. We derive a compositional resilience bound for heterogeneous ICS detection networks, showing that the binding constraint on system-level resilience is the coupling-adjusted absorption capacity of each node along the attack path, not the per-node capacity – so the binding node need not be the weakest one. Empirical validation on the BATADAL water distribution system benchmark demonstrates that the resulting metrics surface operationally significant phenomena invisible to standard benchmarks: the absorption-degradation divergence under adversarial training, and the paradox that hardening the binding node in isolation reduces system-level resilience. Implications for ICS architecture design and certification standards are discussed.

Keywords: Resilience theory, Adversarial robustness, Industrial anomaly detection, Compositional security, Industrial control systems, Intrusion detection systems, Operational technology, Critical infrastructure

1 Introduction

Industrial control systems (ICS) and operational technology (OT) environments are among the most consequential deployment contexts for machine learning: anomaly detectors operate continuously on sensor streams, protect physical processes from adversarial manipulation, and underpin the security posture of critical infrastructure ranging from water treatment to power distribution. Standards bodies and operators increasingly require that these detectors meet formal resilience criteria, not only that they perform well on clean data, but that they absorb adversarial disturbances without catastrophic degradation, recover reliably after attack occurrence, and permit system-level certification from component-level evaluation. Existing resilience frameworks for cyber-physical systems (CPS) define absorb-recover-adapt trajectories at an architectural level and have been operationalised for infrastructure under physical disruption [21, 8], but they do not treat ML-based anomaly detectors as first-class components: there is no formal connection between adversarial ML robustness constructs and the resilience curves, absorption capacities, and recovery trajectories that quantitative CPS resilience theory provides.

On the adversarial ML side, the gap is equally sharp. Adversarial robustness in ICS anomaly detection has attracted sustained research attention [1, 2] and produced a well-established vocabulary of attack

*This work was supported by the European Union's Horizon Research and Innovation Programme under GA No. 101119681 (project ResilMesh).

strategies and defences. Yet robustness is currently treated as a scalar property to be measured on an individual detector, not a compositional property to be derived, bounded, or certified across a deployed system. There is no formal language to ask how the robustness of a heterogeneous ICS network relates to the robustness of its constituent detection nodes, no dynamic model of how detection performance evolves as an attack persists or ceases, and no framework that connects benchmark results to the resilience standards bodies [39].

We argue that both gaps share a common cause: adversarial robustness, as currently formalised, is a special and highly restrictive instantiation of a more general concept that engineering and ecological sciences have studied for decades under the name of system resilience. The ℓp\ell_{p}-norm perturbation budget that defines the adversarial robustness threat model is a degenerate disturbance class that excludes the semantically structured, temporally extended, and physically constrained attacks characteristic of the actual ICS threat landscape. The certified radius is a single point on an absorption curve, not the full profile. The binary robust/not-robust classification collapses a degradation function to a step function, a poor model for systems where graceful degradation under sustained attack matters more than sharp threshold behaviour. Resilience theory, by contrast, provides precisely the constructs that adversarial robustness lacks: disturbance class, absorption capacity, recovery trajectory, and degradation function, as the literature reviewed in Section 2 makes clear. The reframing this paper proposes is consequently structural, and it enables the compositional reasoning that ICS resilience certification requires.

This paper makes three main contributions. First, we provide a formal mapping of the core constructs of resilience theory, i.e. disturbance class, absorption capacity, recovery trajectory, and degradation function, onto the adversarial ML setting for OT anomaly detection, showing in each case that the standard adversarial robustness formalism captures only a degenerate special case of the corresponding resilience construct (Section 3). Second, we derive a compositional resilience bound: we model a heterogeneous ICS network as a directed graph of anomaly detection nodes and show that the system-level resilience under a multi-point attack is bounded above by a function of the minimum node-level absorption capacity weighted by coupling strength along the attack path (Section 4). This result demonstrates formally that the binding constraint on system-level resilience is the coupling-adjusted absorption capacity of each node along the attack path, so that the binding node need not coincide with the minimum-capacity node and its identification requires the network coupling structure that node-level evaluation cannot observe. Third, we introduce and empirically validate a set of domain-appropriate resilience metrics for OT anomaly detection, grounded in (a) extended adversarial robustness experiments based on methodology and architecture from our previous work [34, 11, 32], and (b) new adversarial attack and training experiments on the three-zone edge network conducted for this paper, showing that the metrics capture phenomena, in particular the absorption-degradation divergence under adversarial training, the campaign-level threat model for sustained attacks, and vulnerability amplification along coupled detection paths, that standard adversarial robustness benchmarks miss (Section 5).

The remainder of this paper is structured as follows. Section 2 surveys the empirical literature on adversarial robustness in OT intrusion detection, reviews resilience theory as applied to cyber-physical systems, and states the precise gap that motivates this work. Section 3 formalises the mapping between resilience-theoretic constructs and the adversarial ML setting. Section 4 develops the network model and derives the compositional resilience bound. Section 5 presents experimental validation. Section 6 discusses implications for IDS architecture, certification standards, and open problems. Section 7 concludes.

References (40)