arXiv:2609.08043cs.CVSep 2026

Manuscript Offprint

arXiv:2609.08043

A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation

Jiyoo Noh, Jonathan H. Chan

Jiyoo Noh¹ and Jonathan H. Chan²

¹ University of Toronto, Canada

² King Mongkut's University of Technology Thonburi, Thailand

jiyoo.noh@mail.utoronto.ca, jonathan@sit.kmutt.ac.th

Abstract. Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.

Keywords: Explainable Artificial Intelligence · Temporal Explainability · Echocardiography · Medical Video Segmentation · Grad-CAM.

1 Introduction

Deep learning has become the dominant approach for medical image segmentation, achieving state-of-the-art performance across many imaging modalities [10, 4]. In echocardiography, convolutional neural networks accurately segment the left ventricle (LV) to enable automated estimation of clinically important indices such as ejection fraction [9, 13]. More recently, temporal architectures such as ConvLSTMs [12] have been introduced to exploit motion information across consecutive frames.

J. Noh et al.

Despite these advances, the interpretability of temporal segmentation models remains largely unexplored [5, 4]. Explainable artificial intelligence (XAI) methods such as Gradient-weighted Class Activation Mapping (Grad-CAM) [11] were originally developed for static images and are typically applied independently to each video frame [5]. Consequently, existing evaluations rely primarily on qualitative visualization, providing limited insight into how explanations evolve throughout a cardiac cycle.

To address this gap, we propose a quantitative framework for evaluating temporal explainability in echocardiographic video segmentation. Unlike prior work that relies primarily on qualitative visualization, our framework provides a reproducible quantitative protocol for comparing temporal explanations across video segmentation models. We evaluate Grad-CAM explanations using four complementary temporal saliency metrics that measure explanation stability, spatial motion, anatomical localization, and temporal overlap.

To demonstrate the framework, we compare a conventional 2D U-Net [10] and a ConvLSTM U-Net [12] trained on the EchoNet-Dynamic dataset [9] using multiple temporal sampling intervals. These models were intentionally selected as representative spatial and temporal baselines, as the primary contribution of this work is the evaluation of temporal explainability rather than the development of a new segmentation architecture.

The main contributions of this work are as follows:

  • We introduce a quantitative framework for evaluating temporal Grad-CAM explanations in echocardiographic video segmentation using complementary temporal saliency metrics.
  • We compare representative spatial (2D U-Net) and temporal (ConvLSTM U-Net) segmentation models to investigate how temporal modeling influences explanation dynamics.
  • We establish a preliminary evaluation protocol for temporal explainability in echocardiographic segmentation, providing a foundation for future temporal XAI methods.