MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision

Quanxin Zheng, Shuai Zhao

Quanxin Zheng¹, Shuai Zhao¹

¹China Electronics (Beijing) Information Technology Research Institute Co., Ltd.

Abstract—Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. Dense 3D labels are used only for evaluation and are not involved in patient-specific SDF optimization or threshold selection: volumetric occupancy is defined by ϕ<0\phi < 0, while the surface mesh is extracted at the fixed zero level ϕ=0\phi = 0. We evaluate three weak-mask generators—LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning—and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.906±0.0420.906 \pm 0.042 Dice and 6.41±4.706.41 \pm 4.70 mm HD95 with TransUNet masks, 0.928±0.0250.928 \pm 0.025 and 3.81±2.253.81 \pm 2.25 mm with nnU-Net masks, and 0.928±0.0400.928 \pm 0.040 and 3.80±2.493.80 \pm 2.49 mm with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.

Index Terms— Cardiac MRI, left ventricle, 3D surface reconstruction, implicit neural representation, signed distance field, sparse supervision, weak supervision, reslice consistency

I. INTRODUCTION

Three-dimensional cardiac surface models are useful for quantitative morphology, computational modeling, and intervention planning. Cardiac magnetic resonance (CMR) provides high-quality soft-tissue contrast, but dense and accurate 3D annotation is expensive to obtain. In many annotation-efficient workflows, only a small number of axial planes are labeled even when the CMR volume itself is available.

Reconstructing a continuous LV endocardial surface from these sparse observations is intrinsically ill posed because many 3D shapes can agree with the same 2D masks.

The practical difficulty is compounded when the available masks are generated automatically rather than manually, because segmentation errors in the sparse observations may propagate into the reconstructed 3D geometry. A reconstruction method should therefore satisfy two complementary requirements. First, it should respect the geometric constraints provided by the sparse masks while recovering coherent through-plane geometry without overfitting to their errors. Second, because the weak masks alone cannot reliably determine the boundary between observed slices, the method should exploit independent evidence from the underlying CMR image to guide boundary refinement.

Implicit neural representations provide a natural representation for this problem. A signed distance field (SDF) expresses a surface as the zero level set of a continuous function and supports differentiable geometric regularization. NeuS-style implicit surfaces [2], multiresolution hash encoding [3], and coordinate-based shape representations such as DeepSDF [4] demonstrate the flexibility of continuous fields. In medical imaging, NeSVoR [5] uses a per-case implicit representation for slice-to-volume MRI reconstruction, while NISF and NISF++ [6], [7] learn continuous segmentation/intensity fields from cardiac views. Sparse cardiac shape reconstruction has also been studied with differentiable mesh slicing [9], implicit heart coordinates [8], template-mesh regression [10], multi-view graph decoders [11], and deformable tetrahedra [12]. Among these methods, GHD+DVS is the closest methodological comparator because it likewise performs patient-specific optimization from sparse 2D observations without cohort training. However, GHD+DVS deforms a predefined template mesh from slice-based segmentation constraints, whereas the setting considered here requires a continuous field that can use the underlying CMR image to correct errors in automatically generated weak masks. To the best of our knowledge, prior work has not examined the specific combination considered here: MM-WHS MRI, automatically generated sparse axial masks from heterogeneous upstream segmenters, and patient-specific LV SDF optimization without a cohort-level shape prior.

The source of weak masks is itself important. TransUNet [18] and nnU-Net [19] provide task-specific supervised segmenters when trained under leave-one-out (LOO) splits, whereas Medical SAM3 [20] provides a prompt-driven medical foundation model that can be applied from

Corresponding author: Shuai Zhao (zhaoshuai@cestc.cn). This work was supported by Beijing xxx xxxxx (No. xxxxxxx).

a released pretrained checkpoint without MM-WHS-specific training or fine-tuning. This distinction allows us to test not only reconstruction accuracy, but also whether the proposed reconstruction framework remains effective when the upstream weak-mask generator changes substantially in training regime and error characteristics.

We propose MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction (MR-RS-SDFR), a per-case cross-slice SDF framework for reconstructing the LV blood-pool endocardial surface from a CMR volume under supervision from sparse, weak axial masks. The core idea is to separate reconstruction into a strong geometric initialization and an image-guided refinement stage. The initialization converts sparse masks into a stable continuous SDF prior, while refinement combines two complementary signals: MRI edge-field normal alignment provides a ground-truth-free boundary cue derived from the CMR intensity-gradient magnitude, and differentiable reslicing enforces consistency with the observed masks.

The main contributions are:

  • a per-case sparse-to-continuous SDF reconstruction framework that combines geometry-preserving initialization with MRI-guided refinement to recover continuous LV surfaces from sparse weak masks without dense voxel-level supervision during patient-specific SDF optimization;
  • an MRI edge-field normal alignment objective that uses a gradient-magnitude-derived image pseudo-normal to provide a boundary cue independent of the weak segmentation masks;
  • a differentiable reslice-consistency objective that combines region-level soft Dice with contour-level consistency on the acquired sparse planes to constrain surface drift during refinement.

We evaluate the framework with weak masks generated by LOO TransUNet, LOO nnU-Net, and pretrained Medical SAM3, and vary the number of observed axial planes over K∈{4,8,16,32,64}K \in \{4, 8, 16, 32, 64\}. The expanded evaluation separates three questions: how the upstream segmenters perform directly, how their sparse masks propagate through PCHIP, SDF initialization, and final MRI-guided refinement, and whether the resulting surfaces remain more accurate than a full GHD+DVS reconstruction driven by the same sparse-16 masks. The direct results show that generator quality depends on the metric: 2D Dice follows nnU-Net > Medical SAM3 > TransUNet, whereas dense-volume 3D Dice/HD95 follows nnU-Net > TransUNet > Medical SAM3. After sparse-16 MR-RS-SDFR reconstruction, nnU-Net and Medical SAM3 both reach 0.928 mean Dice, while TransUNet reaches 0.906. MR-RS-SDFR is also numerically better than full GHD+DVS for all three matched mask sources. This design therefore tests both reconstruction accuracy and dependence on the upstream weak-mask generator without assuming that one upstream metric alone determines downstream utility.