Manuscript Offprint

arXiv:2609.04390

Development and Evaluation of Ultrasound Image Learning Pipelines for MASLD Risk Stratification

Guangyi Zhang, Xiaohong Wang, Eugene Cheah, Peng Guo, Brian A. Telfer, Theodore T. Pierce, Anthony E. Samir

Guangyi Zhang1,†^{1,\dagger}, Xiaohong Wang1,†^{1,\dagger}, Eugene Cheah1^{1}, Peng Guo1^{1}

Brian A. Telfer2^{2}, Theodore T. Pierce1^{1}, Anthony E. Samir1,∗^{1,*}

1^{1} Center for Ultrasound Research & Translation, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA

2^{2} Lincoln Laboratory, Massachusetts Institute of Technology, Lexington, MA, USA

Abstract—Metabolic dysfunction-associated steatotic liver disease (MASLD) affects approximately 30% of the general population. Ultrasound-based imaging, including B-mode imaging and shear wave elastography (SWE), is widely used for noninvasive fibrosis assessment; however, the role of deep learning-based ultrasound image learning for MASLD risk stratification remains insufficiently characterized. In this study, we developed and evaluated ultrasound image learning pipelines using B-mode and SWE images for fibrosis staging and identification of patients with at-risk metabolic dysfunction-associated steatohepatitis (MASH). A total of 250 ultrasound examinations, one exam per subject, were included. Model performance was evaluated using 3-fold cross-validation with area under the receiver operating characteristic curve (AUROC). End-to-end SWE image learning achieved performance comparable to operator-guided SWE across fibrosis stages. Overall, SWE-based learning consistently outperformed B-mode image learning in fibrosis staging, with AUROC improvements from 0.64 (95% CI: [0.56, 0.72]) to 0.72 (95% CI: [0.65, 0.79]) for F≥2 (significant fibrosis, p=0.11), from 0.67 (95% CI: [0.58, 0.75]) to 0.78 (95% CI: [0.72, 0.85]) for F≥3 (advanced fibrosis, p=0.02), and from 0.69 (95% CI: [0.56, 0.82]) to 0.80 (95% CI: [0.72, 0.89]) for F4 (cirrhosis, p=0.10). These findings highlight the potential of SWE image learning for MASLD risk stratification.

Index Terms—Ultrasound imaging; Shear wave elastography; deep learning; Metabolic dysfunction-associated steatotic liver disease

I. INTRODUCTION

Metabolic dysfunction-associated steatotic liver disease (MASLD) is defined by hepatic steatosis with at least one cardiometabolic risk factor [1]. Its prevalence has increased rapidly over recent decades and currently affects approximately one-third of the U.S. population [2]. MASLD encompass a broad disease spectrum ranging from simple steatosis to metabolic dysfunction-associated steatohepatitis (MASH), fibrosis, and cirrhosis. A subset of patients with MASH may progress to hepatocellular carcinoma, contributing substantially to morbidity, mortality, and economic burden [3]. Among these patients, liver fibrosis is a major predictor of adverse clinical outcomes. Early detection and assessment on the degree of liver fibrosis is critical, as timely interventions can prevent severe liver-related outcomes [4].

Liver biopsy serves as the reference standard for fibrosis diagnosis and staging. However, the broad clinical application of liver biopsy on MASLD screening has constrained by its invasiveness, high cost, observer dependence, and procedure risks [5]. There is a clear need for noninvasive, reliable, and scalable tool for fibrosis assessment.

Conventional B-mode ultrasound (US) is widely due to its safety, accessibility, and low cost, enabling assessment of liver morphology changes associated with disease progression, while the interpretation of sonographic features is subjective [6], limiting sensitivity for early-stage fibrosis detection.

US elastography, including two-dimensional (2-D) shear wave elastography (SWE), provides quantitative liver stiffness measurement based on Young's modulus (kPa) or shear wave velocity (m/s) and has gained adoption for MASLD risk stratification. Compared with conventional B-mode, SWE offers greater objectivity, though its performance may be impacted by technical factors, patient habitus, and biologic confounders [7]. Furthermore, the current clinical workflow for 2-D SWE imaging on certain vendor platforms requires manual placement of a circular region of interest (ROI) within the elasticity box. This is a time-consuming and operator-dependent step that is a barrier to effective population level screening.

To address these limitations, deep learning (DL), particularly convolutional neural networks, have been explored for prediction of liver fibrosis using US images [8]–[12]. These approaches aim to capture subtle texture or patterns that may not be distinguished by human, potentially enabling improved detection of early fibrosis. Despite promising results, variability in data sets, model architectures, and evaluation protocols has constrained direct comparison with established methods.

In this work, we develop and evaluate DL-based US image learning pipelines using both B-mode and SWE images, and compare these methods within a unified framework, including operator-guided SWE as a reference. This enables systematic assessment of SWE image learning for fibrosis staging and at-risk MASH identification. Our work seeks to lay a foundation for an end-to-end noninvasive screening tool to stratify the risk

†^{\dagger}These authors contributed equally to this work. *Corresponding author: asamir@mgh.harvard.edu. This study was supported in part by NIH R01 DK119860, the 2020 American Roentgen Ray Scholar Award, and 2019 Society of Abdominal Radiology Wylie J. Dodds Research award.

© 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

Figure

Fig. 1: Schematic of data modalities and representations. a, Conventional B-mode ultrasound. Grayscale liver ultrasound images capturing parenchymal echotexture and anatomical structures were used as imaging inputs. b, SWE ultrasound. the elastography map is shown as a rectangular acquisition box overlaid on the B-mode image. Within this SWE box, a circular ROI is placed to sample liver stiffness measurements.

of liver fibrosis in MASLD patients.

References (28)

  • AASLD Practice Guidance on the Clinical Assessment and Management of Nonalcoholic Fatty Liver Disease
  • Estimated Burden of Metabolic Dysfunction-Associated Steatotic Liver Disease in US Adults, 2020 to 2050
  • Projected Global Clinical, Humanistic, and Economic Impact of Metabolic Dysfunction-Associated Steatohepatitis (MASH): The Cost of Inaction Based on Data From Nine Countries
  • Predictors of Fibrosis, Clinical Events and Mortality in MASLD: Data from the Global-MASLD Study
  • Liver Biopsy for Assessment of Chronic Liver Diseases: A Synopsis
  • Non-invasive Diagnosis of Liver Fibrosis and Cirrhosis
  • Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 2, Diagnostic Performance, Confounders, and Future Directions
  • Evaluation of Hepatic Fibrosis using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
  • Automatic Diagnosis of Significant Liver Fibrosis from Ultrasound B-Mode Images Using a Handcrafted Feature-Assisted Deep Convolutional Neural Network
  • Deep Learning for Non-invasive Detection of Steatosis and Fibrosis in MASLD: A Multicenter study with A New Fibroscan-labelled Ultrasound Dataset
  • Liver Fibrosis Classification from Ultrasound Using Machine Learning: A Systematic Literature Review
  • Deep Learning without Borders: Recent Advances in Ultrasound Image Classification for Liver Diseases Diagnosis
  • Prospective Study of Outcomes in Adults with Nonalcoholic Fatty Liver Disease
  • Association between Pattern of Hepatic Iron Deposition and Severity of MASH among Patients Enrolled in the NASH Clinical Research Network
  • Liver Segmentation in Ultrasound Images Using Self-Supervised Learning with Physics-inspired Augmentation and Global-Local Refinement
  • Deep Learning with Ultrasonography: Automated Classification of Liver Fibrosis Using a Deep Convolutional Neural Network
  • Deep Residual Learning for Image Recognition
  • EfficientNet: Rethinking Model Scaling for Convolutional Neural Networks
  • A ConvNet for the 2020s
  • An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
  • BEiT: BERT Pre-Training of Image Transformers
  • Swin Transformer: Hierarchical Vision Transformer Using Shifted Windows
  • MaxViT: Multi-Axis Vision Transformer
  • MambaOut: Do We Really Need Mamba for Vision?
  • Image Processing Pipeline for Liver Fibrosis Classification using Ultrasound Shear Wave Elastography
  • Objective Liver Fibrosis Estimation from Shear Wave Elastography
  • Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
  • Improving Effectiveness of Liver US Shear-Wave Elastography Using A Quality Improvement Framework