Manuscript Offprint
arXiv:2609.04598PetQA: Benchmarking Veterinary Knowledge and Clinical Reasoning
Abstract
We introduce PETQA, a Korean long-form question-answering (QA) benchmark for evaluating veterinary knowledge and clinical reasoning in large language models (LLMs) and large vision-language models (LVLMs). PETQA contains 10,076 text-only and 8,751 multimodal QA pairs derived from real-world questions about dogs and cats, paired with answers from expert veterinarians. Its test split, PETQA-BENCH, further includes annotations for question types and clinical conditions. We evaluate eighteen models using ROUGE, BERTScore, and LLM-as-a-judge metrics for factuality and helpfulness under three settings: zero-shot inference, retrieval-augmented generation (RAG), and supervised fine-tuning (SFT). The benchmarking results provide an overview of the strengths and limitations of current models in addressing veterinary clinical queries and highlight the need for more effective adaptation methods to develop clinically reliable AI systems for veterinary care. To facilitate broader use, we additionally provide translated versions of PETQA-BENCH in five languages.
1 Introduction
With advances in LLMs and LVLMs, their adoption in high-stakes domains such as healthcare has grown substantially (Jeong et al., 2024; Singhal et al., 2023; Li et al., 2023). Despite the increasing number of households with companion animals and the growing demand for pet care and health management (American Pet Products Association, 2025), most existing benchmarks for medical AI evaluation have primarily focused on human medicine (Jin et al., 2022; Wang et al., 2025), leaving limited resources for evaluating clinical knowledge and reasoning capabilities in specialized domains such as veterinary medicine (Luo et al., 2025). Pet owners often seek advice from AI systems about abnormal symptoms observed in
their companion animals (Royal Society for the Prevention of Cruelty to Animals, 2026), highlighting the need to systematically assess models' veterinary knowledge and clinical reasoning capabilities in realistic scenarios.
To address this gap, we present PETQA, a Korean long-form QA dataset for veterinary medicine, comprising 10,076 QA pairs with text-only questions and 8,751 QA pairs with multimodal questions. We collect diverse real-world questions about dogs and cats from a major QA platform in South Korea, along with high-quality answers provided by verified experts. The data undergo a series of preprocessing steps and a quality assessment conducted with a veterinary expert holding a Ph.D. The test split, referred to as PETQA-BENCH, contains 2,000 QA pairs per modality and includes annotations for question types and clinical conditions. The combination of a large-scale collection of real-world questions, long-form reference answers from veterinary experts, and both text-only and multimodal questions enables the systematic evaluation of LLMs' and LVLM's veterinary knowledge and clinical reasoning abilities in realistic scenarios.
For initial benchmarking, we evaluate eighteen models—categorized as closed LVLMs, open-weight LVLMs, and open-weight LLMs—using two traditional metrics (ROUGE and BERTScore) and two LLM-as-a-judge metrics (factuality and helpfulness). ROUGE, BERTScore, and factuality are reference-based metrics evaluated against veterinary expert-provided answers, whereas helpfulness is assessed in a reference-free manner. We examine zero-shot inference, retrieval-augmented generation (RAG), and supervised fine-tuning (SFT) as three model evaluation settings. We find that closed models generally outperform open-weight models, particularly in factuality and helpfulness; all models perform consistently worse on multimodal questions than on text-only questions; and RAG and SFT yield inconsistent improvements
| Dataset | Source | Answer Format | Language | Modality | Size | Target Subject |
|---|---|---|---|---|---|---|
| BioASQ (Tsatsaronis et al., 2015) | Medical | Span-based, | En | Text | 4,721 | Human |
| PubMedQA (Jin et al., 2019) | Article | Binary | En | Text | 1,000 | |
| MMLU (Med.) (Hendrycks et al., 2021) | En | Text | 1,089 | |||
| MedQA (Jin et al., 2021) | En, Zh | Text | 61,097 | |||
| MedMCQA (Pal et al., 2022) | En | Text | 193,155 | |||
| CMExam (Liu et al., 2023) | Medical | Multiple-choice | Zh | Text | 68,119 | |
| MedBench (Liu et al., 2024) | Licensing | Zh | Text | 40,041 | ||
| KorMedMCQA (Kweon et al., 2024) | Examination | Ko | Text | 7,469 | ||
| MLEC-QA (Li et al., 2021) | Zh | Multimodal | 136,236 | |||
| MedXpertQA (Zuo et al., 2025) | En | Multimodal | 4,460 | |||
| K-QA (Manes et al., 2024) | Online Platform | Open-ended(long-form) | En | Text | 1,212 | |
| Hosseini et al. (2024) | En | Text | 1,077 | |||
| PETQA (Ours) | Online Platform | Open-ended(long-form) | Ko | Multimodal | 18,827 | Companion Animals(Dogs and Cats) |
Table 1: Comparison of PETQA with existing medical benchmarks.
in LLM-as-a-judge metrics. These findings characterize the capabilities and limitations of current models for veterinary clinical QA and underscore the need for more effective methods to enable more reliable AI support for veterinary care.
Our contributions are summarized as follows:
-
We introduce PETQA, a Korean long-form QA dataset designed to evaluate the ability of LLMs and LVLMs to respond to veterinary clinical queries. To the best of our knowledge, PETQA is the first long-form QA dataset for veterinary medicine.
-
We present initial benchmarking results for eighteen models using two traditional and two LLM-as-a-judge metrics under zero-shot, RAG, and SFT settings.
-
We publicly release PETQA through our GitHub repository¹. To facilitate broader research in the NLP community, we additionally provide translated versions of PETQA-BENCH in five languages.
Multiple-choice question answering (MCQA) benchmarks (Kweon et al., 2024; Zuo et al., 2025) are widely used because they enable straightforward quantitative evaluation of medical knowledge. However, recent studies suggest that MCQA may overestimate clinical reasoning ability, as models can exploit superficial patterns among answer choices rather than demonstrate genuine understanding (Griot et al., 2025). Moreover, physicians are not provided with predefined options when making clinical decisions (Cocchieri et al., 2026). To address these limitations, recent studies have explored long-form QA, which requires detailed answers to open-ended questions (Fan et al., 2019). Manes et al. (2024) constructed K-QA, comprising 1,212 patient questions and 201 curated physician answers, and introduced NLI-based metrics for clinical comprehensiveness and hallucination. Similarly, Hosseini et al. (2024) introduced a benchmark with 1,077 real-world consumer queries and long-form answers evaluated by medical doctors.
Existing medical QA benchmarks have largely focused on human healthcare and have been primarily developed in English and Chinese (Li et al., 2021; Liu et al., 2023, 2024). In veterinary medicine, benchmark resources remain scarce, with existing benchmarks limited to MCQA (Luo et al., 2025; Tam et al., 2026). To bridge this gap, we present PETQA, a Korean long-form QA benchmark for veterinary medicine that enables comprehensive evaluation of QA systems for dogs and cats, two of the most common companion animals in veterinary practice. A comparison between PETQA and existing medical QA resources is provided in Table 1.
3 Dataset: PETQA
We introduce PETQA, a long-form QA dataset designed to benchmark the veterinary knowledge
¹https://github.com/ssu-humane/PetQA
Raw Data
PetQA

Figure 1: A raw data sample (left) and its corresponding example from PETQA (right).
and clinical reasoning capabilities of LLMs and LVLMs. PETQA comprises both text-only and multimodal questions about dogs and cats in realistic clinical scenarios, with answers provided by expert veterinarians. Figure 1 illustrates how a raw data sample was processed and labeled. Further dataset details are provided in Appendix B.
3.1 Data Collection and Preprocessing
Data Collection We collected question-answer pairs related to veterinary care from Naver Knowledge iN, one of the major community-driven online QA platforms in South Korea. Users can post questions to topic-specific boards and receive answers. Among multiple answers, the questioner can select one or more as helpful answers. The platform also provides expert answers through collaborations with affiliated organizations; users who possess nationally authorized professional licenses and association memberships can participate as experts (Choi et al., 2025). Verification status is displayed through badges.
The target board for pet medical consultation contains a wide range of pet health inquiries, from general veterinary knowledge to real-world clinical questions such as symptom diagnosis and disease treatment. Each post consists of a question title, a question body that may include images, and a set of answers. Our initial data collection comprised 83,509 posts published between 2014 and 2024, each containing at least one answer selected as helpful by the questioner. The answers were provided either by anonymized users without verification or by 23 experts, all of whom are veterinarians whose
identities were verified by the platform.
Rule-based Preprocessing We focused on dogs and cats because they are the two most common companion animals both globally (Hoffmann et al., 2018) and on the platform. After filtering out posts with duplicate questions or corrupted images, we retained 27,124 posts about the target animals, with answers selected by verified experts. Based on our preliminary investigation and preprocessing practices adopted in previous QA research (Nguyen et al., 2023; Wang et al., 2026), we applied additional filtering and preprocessing steps to these posts.
LLM-based Preprocessing Following recent work (Arias-Duart et al., 2025; Baumgärtner et al., 2025), we leveraged an LLM-based preprocessing pipeline to construct a coherent set of QA pairs while reducing noisy expressions. We first prompted GPT-4o-mini (Hurst et al., 2024) to filter out irrelevant posts, including questions unrelated to pet medical consultation (e.g., seeking advice on admission to veterinary school), answers based on unsupported speculation, and uninformative answers such as generic recommendations to visit a clinic. We further sanitized the text by removing personally identifiable information, correcting grammatical and spelling errors, and removing promotional content.
To assess the reliability of the LLM-based preprocessing, we manually evaluated 100 randomly sampled instances using two criteria: coherence and completeness. The results showed that 97 samples were coherent and 92 preserved all essential information without omission. The prompts and detailed evaluation guidelines are provided in Appendix G and H, respectively.
Data Split We split both the text-only and multi-modal subsets into training, validation, and test sets, following the configurations of existing resources (Table 1).
-
Text: Text-only questions with text answers (6,076 / 2,000 / 2,000)
-
Multimodal: Questions with an image and text answers (4,751 / 2,000 / 2,000)
The test sets, collectively referred to as PETQA-BENCH, are used primarily for benchmarking experiments, whereas the training and validation sets are used for supervised fine-tuning experiments.
3.2 Label Annotation
For PETQA-BENCH, we annotated each questions with two labels: question type and clinical condition. These labels were designed to assess model performance across different clinical scenarios and to determine whether model responses contain key clinical conditions, respectively.
The first step involved constructing a reliable annotation scheme and training the annotators. The initial guideline was carefully reviewed by the fourth author, a veterinary expert holding a Ph.D. Using 50 randomly sampled examples from the test set, six annotators participated in a pilot task in which they labeled the samples according to the initial guideline. Inter-annotator agreement was measured using Krippendorff's (Krippendorff, 2018), and the process was repeated until exceeded 0.7. This indicated that the refined guideline yielded reliable annotations. When agreement was low, the annotators and authors discussed disagreements to resolve them and refine the guideline.
In the second step, the remaining samples in the test set were divided among the six annotators and independently labeled. We hired the annotators from the authors' institution and paid them in accordance with local wage laws. All annotators were students majoring in AI (four master's students and two undergraduate students), and two had experience caring for dogs and/or cats.
Question Type Each question was assigned a single label based on the perceived intent of the questioner. Following prior research in medical
| Metric | Text | Multimodal |
|---|---|---|
| Target species | ||
| Dog | 1,672 | 1,650 |
| Cat | 328 | 350 |
| Question type | ||
| Diagnosis | 1,231 | 1,699 |
| Treatment | 377 | 129 |
| Basic veterinary knowledge | 221 | 60 |
| Miscellaneous | 171 | 112 |
| Text tokens | ||
| Questions | ||
| - Max. | 838.0 | 819.0 |
| - Mean. | 143.6 | 104.3 |
| - Min. | 10.0 | 9.0 |
| Answers | ||
| - Max. | 430.0 | 796.0 |
| - Mean. | 119.6 | 141.7 |
| - Min. | 11.0 | 16.0 |
Table 2: Descriptive statistics of PETQA-BENCH.
QA (Zuo et al., 2025), we established four categories: (1) Diagnosis, which includes the identification of diseases based on symptoms and the inference of possible causes; (2) Treatment, which includes treatment methods and preventive measures; (3) Basic veterinary knowledge, which covers general knowledge such as medical concepts and disease mechanisms; (4) Miscellaneous, which includes questions unrelated to pet medical consultation or administrative queries (e.g., hospital information and costs).
Clinical Condition For questions labeled as diagnosis, annotators labeled the corresponding clinical conditions based on the selected answer. Clinical conditions include diseases, syndromes, and clinical states (Tresker, 2020). To support the annotation process, we provided a deduplicated list of 5,378 clinical-condition entries compiled from three reputable sources, including an official animal disease classification system (Ministry of Agriculture, Food and Rural Affairs, 2025). Entries include conditions such as vomiting and diarrhea.
Quality Check The fourth author, a veterinary expert, reviewed 100 randomly sampled QA pairs and their labels, with 50 from each of the Text and Multimodal sets. The evaluation used two criteria: relevance, which assesses whether the answer appropriately addresses the question, and correctness, which assesses whether the answer is factually accurate. The results showed that 99 samples were relevant and 85 were correct, supporting the

Figure 2: Distribution of the top-five clinical conditions in PETQA-BENCH.
dataset's overall reliability. Further details of the expert verification are provided in Appendix H.
3.3 Descriptive Analysis
Table 2 shows the descriptive statistics of PETQA-BENCH. Questions about dogs are more frequent than those about cats. In terms of question type, Diagnosis is the most frequent category, followed by Treatment, indicating that our benchmark contains a substantial proportion of queries involving clinical scenarios. In particular, Diagnosis is the most frequent category in both the Text and Multimodal sets, with a higher proportion in the Multimodal set. This trend suggests that images may help questioners convey symptoms.
Figure 2 shows the distributions of the five most frequent clinical conditions in PETQA-BENCH, with proportions calculated separately for the Text and Multimodal sets. Vomiting is the most prevalent condition in both sets, followed by diarrhea and pancreatitis. In contrast, dermatitis ranks among the most frequent clinical conditions primarily in the Multimodal set. The Text and Multimodal sets cover 243 and 233 unique conditions, respectively, and 352 unique conditions when combined. These results highlight the broad range of clinical conditions represented in our dataset.
3.4 Multilingual Extensions
To improve the dataset's global applicability and broaden its potential impact, we translated PETQA-BENCH into five widely spoken languages—English, German, Chinese, Indonesian, and Arabic—using an LLM-based machine translation pipeline. We selected these target languages based on their broad speaker coverage and linguistic diversity (Schneider and Sitaram, 2024). We used GPT-4o-mini with a translation prompt adapted from Lee et al. (2025). Further details on the translation process and analysis are provided in Appendix F.
4 Experiments
This section describes the experimental configuration, target models, and evaluation metrics used in the benchmarking experiments.
4.1 Configuration
Using PETQA-BENCH, we assessed the veterinary knowledge and clinical reasoning capabilities of LLMs and LVLMs under three settings. For closed-book QA, we evaluated their zero-shot abilities based on the knowledge encoded in their parameters. For open-book QA, we employed a RAG (Lewis et al., 2020) pipeline using a veterinary reference widely used in clinical practice as the knowledge source. For SFT, we trained the models using the training set of PETQA. We used greedy decoding with a temperature of 0 for all models, resulting in deterministic outputs for open-weight models. For closed models, we reported scores averaged over three runs. Further details on the experimental configurations are provided in Appendix D.
4.2 Models
We evaluated eighteen models that support Korean. Based on their vision capabilities and weight availability, we categorized the models into three groups: (1) Closed LVLMs: GPT-4.1 mini, GPT-4.1, Gemini 2.5 Flash, and Gemini 2.5 Pro; (2) Open-weight LVLMs: Qwen3-VL-8B, Qwen3-VL-32B, Gemma-3-12B, Gemma-3-27B, MedGemma-27B, A.X-4.0-VL-Light, and HCX-SEED-Vision-3B; and (3) Open-weight LLMs: Qwen3-8B, Qwen3-32B, Gemma-2-9B, Gemma-2-27B, MedGemma-27B-Text, A.X-4.0-Light, and HCX-SEED-Text-1.5B. Model checkpoints and additional details are provided in Appendix D.
4.3 Evaluation
We used four evaluation metrics to assess whether model-generated responses align with expert-provided answers and provide helpful information. Specifically, we adopted two traditional metrics and two LLM-as-a-judge metrics, following recent practices in medical QA (Zhang et al., 2025b; He et al., 2025). Additional details are provided in Appendix C.
| Model | Text | Multimodal | ||||||
|---|---|---|---|---|---|---|---|---|
| ROUGE | BERTScore | Factuality | Helpfulness | ROUGE | BERTScore | Factuality | Helpfulness | |
| Closed large vision-language models | ||||||||
| GPT-4.1 mini | ||||||||
| GPT-4.1 | ||||||||
| Gemini 2.5 Flash | ||||||||
| Gemini 2.5 Pro | ||||||||
| Open-weight large vision-language models | ||||||||
| Qwen3-VL-8B | 0.271 | 0.737 | 0.499 | 3.961 | 0.204 | 0.721 | 0.461 | 3.076 |
| Qwen3-VL-32B | 0.258 | 0.730 | 0.513 | 4.867 | 0.215 | 0.712 | 0.489 | |
| Gemma-3-12B | 0.287 | 0.740 | 0.510 | 4.561 | 0.243 | 0.723 | 0.490 | 4.255 |
| Gemma-3-27B | 0.280 | 0.737 | 0.519 | 4.870 | 0.496 | 4.626 | ||
| MedGemma-27B | 0.259 | 0.715 | 0.503 | 4.872 | 0.220 | 0.702 | 0.442 | 4.634 |
| A.X-4.0-VL-Light | 0.277 | 0.727 | 0.482 | 3.731 | 0.238 | 0.722 | 0.461 | 3.623 |
| HCX-SEED-Vision-3B | 0.284 | 0.735 | 0.493 | 3.776 | 0.230 | 0.718 | 0.451 | 3.671 |
| Open-weight large language models | ||||||||
| Qwen3-8B | 0.294 | 0.514 | 3.754 | |||||
| Qwen3-32B | 0.282 | 0.742 | 0.530 | 4.433 | ||||
| Gemma-2-9B | 0.288 | 0.733 | 0.518 | 4.176 | ||||
| Gemma-2-27B | 0.275 | 0.716 | 0.489 | 4.554 | ||||
| MedGemma-27B-Text | 0.288 | 0.739 | 0.546 | 4.794 | ||||
| A.X-4.0-Light | 0.289 | 0.730 | 0.502 | 4.212 | ||||
| HCX-SEED-Text-1.5B | 0.483 | 3.479 | ||||||
Table 3: Zero-shot performance measured on PETQA-BENCH. Bold and underlined values indicate the best and second-best results, respectively. Results for closed LVLMs are averaged over three runs.
ROUGE A reference-based metric widely used to measure lexical overlap between model-generated and reference answers (Lin, 2004). We used ROUGE-L in this study.
BERTScore A metric that captures semantic similarity between generated and reference answers using BERT-based contextual embeddings (Zhang et al., 2020), thereby complementing the lexical evaluation provided by ROUGE.
Factuality A reference-based LLM-as-a-judge metric (Akhtar et al., 2026) using Gemini 2.5 Flash as the judge. Following FactScore (Min et al., 2023), the judge decomposes the reference and model-generated answers into atomic facts and measures their factual alignment.
Helpfulness A reference-free LLM-as-a-judge metric (Zhang et al., 2025a). GPT-4o (Hurst et al., 2024) served as the judge, rating the relevance and informativeness of each model-generated answer with respect to the question on a five-point Likert scale.
5 Benchmarking Results
We present the benchmarking results of eighteen models on PETQA-BENCH, focusing on veterinary knowledge and clinical reasoning. We report the zero-shot performance of the target models as our main results and then investigate the effects of RAG and SFT as alternative strategies for model adaptation. Qualitative case studies are provided in Appendix E. We additionally report benchmarking results for the English version of PETQA-BENCH in Table A8 and for the German, Chinese, Indonesian, and Arabic versions in Table A9.
5.1 Zero-Shot Performance
We summarize three key findings from Table 3. We conducted Wilcoxon signed-rank tests to assess the statistical significance of pairwise performance differences. Claims in the text regarding performance differences were made only when the corresponding pairwise comparison was statistically significant. All findings identified below are statistically significant ().
Closed models achieved the highest performance in most cases. Closed models achieved the highest performance in most cases across both datasets. In the Text set, GPT-4.1 mini achieved the highest ROUGE score (0.303) and BERTScore (0.746), while Qwen3-8B achieved a comparable BERTScore. GPT-4.1 achieved the highest factuality score (0.569), and Gemini 2.5 Pro achieved the highest helpfulness score (4.923). In the Multimodal set, Gemini 2.5 Pro ranked highest in ROUGE (0.246) and helpfulness (4.814) and was one of the top-performing models in

Figure 3: Performance by question type on PETQA-BENCH. For each metric, the x-axis denotes question type: D (Diagnosis), T (Treatment), B (Basic veterinary knowledge), and M (Miscellaneous).
terms of BERTScore (0.726). GPT-4.1 and GPT-4.1 mini achieved the highest factuality scores (0.531). Some open-weight models remained competitive. In the Text set, MedGemma-27B-Text performed comparably to the best-performing models across metrics. Qwen3-8B achieved the highest BERTScore (0.746), but its LLM-as-a-judge scores were substantially lower than those of the top-performing models. Gemma-3-27B showed a similar trend in the Multimodal set, achieving competitive scores only on traditional metrics.
Factuality and helpfulness increased with model size, whereas ROUGE and BERTScore did not. Within the same model family, factuality and helpfulness scores generally increased with model size, as exemplified by Qwen3-VL. There were several exceptions, including Gemma-2 for factuality. In contrast, ROUGE and BERTScore showed no consistent relationship with model size, suggesting the limitations of traditional metrics and the value of complementary LLM-as-a-judge evaluations.
LVLMs underperformed on the Multimodal set. Across model comparisons, performance on the Multimodal set was consistently lower than that on the Text set. To examine whether differences in question-type distributions contributed to this trend, we conducted additional comparisons using only questions from the most frequent question type and

Figure 4: Clinical condition inclusion performance on the Text set.
sets resampled to match the question-type distribution; the same trend persisted (Appendix F). Thus, the observed differences may reflect the greater difficulty of the multimodal questions, limitations of current LVLMs, or both, rather than differences in question-type distributions.
5.1.1 Performance by Question Type
Figure 3 presents heatmaps illustrating model performance by question type on the Text and Multimodal sets. Using the Kruskal–Wallis test, we found statistically significant differences in scores for every metric-set combination ().
On the Text set, the target models tended to achieve the best ROUGE and BERTScore perfor-

Figure 5: factuality between RAG and zero-shot inference, where positive values indicate the superiority of RAG.
mance on questions about basic veterinary knowledge. In contrast, they achieved the highest factuality scores on diagnosis questions. For helpfulness, we did not observe consistent differences across question types. When comparing model groups, closed LVLMs consistently outperformed the other models across question types, indicating greater robustness in generating helpful responses. By contrast, most open-weight models substantially underperformed in terms of helpfulness, except for Qwen3-VL-32B, MedGemma-27B, and MedGemma-27B-Text.
On the Multimodal set, all LVLMs achieved the highest factuality scores on diagnosis questions, consistent with the findings on the Text set. They achieved the highest ROUGE scores on miscellaneous questions. For BERTScore, we observed no substantial differences across question types, again consistent with the findings on the Text set.
5.1.2 Clinical Condition Inclusion
To further assess the helpfulness of model-generated responses to diagnosis questions while complementing reference-based metrics that consider the entire response, we examined whether model responses included relevant clinical conditions, such as disease names or symptoms. We used the partial match (PM) score (Li et al., 2022), which measures overlap between model responses and ground-truth clinical conditions.
Figure 4 shows performance on the Text set, ranked by PM score. Gemini 2.5 Pro performed best, outperforming the second-best model by 0.018. Notably, MedGemma-27B-Text and Gemma-3-27B ranked second and third, outperforming the other closed models. To investigate whether the inclusion of clinical conditions was
associated with performance on the four primary evaluation metrics, we further divided the diagnosis responses generated by Gemini 2.5 Pro for 694 QA pairs with non-empty ground-truth clinical conditions into matched (PM > 0; N = 510) and unmatched (PM = 0; N = 184) groups. The matched group obtained higher ROUGE (0.296 > 0.277), BERTScore (0.744 > 0.739), factuality (0.607 > 0.571), and helpfulness (4.947 > 4.929). These results suggest that the inclusion of relevant clinical conditions may be an important characteristic of accurate and helpful responses in veterinary QA.
The corresponding results for the Multimodal set are shown in Figure A1 and discussed in Appendix F.
5.2 Retrieval-Augmented Generation
RAG produced model-, metric, and modality-dependent effects. On the Text set, factuality improved for 12 of 18 models, whereas ROUGE and BERTScore decreased for 12 and 11 models, respectively; helpfulness decreased for 10 models. On the Multimodal set, factuality and helpfulness each improved for 8 of 11 models, while ROUGE and BERTScore decreased for 8 and 9 models, respectively. GPT-4.1 achieved the highest factuality score (0.571) and helpfulness score (4.931) on the Text set. For ROUGE, GPT-4.1 mini and Gemma-2-9B achieved the highest performance (0.299), while Qwen3-8B achieved the highest BERTScore (0.746). Gemini 2.5 Pro led all metrics on the Multimodal set. Full results are provided in Table A10.
Figure 5 shows the change in factuality, a core dimension in medical scenarios (Wang et al., 2025; Wu et al., 2025). On the Text set, Gemma-2-27B and GPT-4.1 mini showed the largest gains, whereas MedGemma-27B-Text and Gemma-2-9B showed performance degradation. On the Multimodal set, the largest gain was comparable to that observed on the Text set, whereas the largest decrease was 0.033 for Gemma-3-12B. Qualitative examples illustrate that successful retrieval of relevant information helped the model correct a zero-shot misdiagnosis (Figure A2), whereas irrelevant retrieved evidence led to an incorrect diagnosis by causing the model to prioritize textual evidence while disregarding the input image (Figure A3).
5.3 Supervised Fine-Tuning
SFT produced a trade-off across metrics. On the Text set, ROUGE and BERTScore improved for all 14 models, whereas factuality decreased for 11 and helpfulness decreased for all 14. On the Multimodal set, ROUGE improved for all 7 models and BERTScore improved for 6, while factuality decreased for 6 and helpfulness decreased for all 7. On the Text set, MedGemma-27B-Text achieved the best performance with a BERTScore of 0.780, a factuality score of 0.524, and a helpfulness score of 2.943. For ROUGE, Gemma-3-27B ranked highest at 0.366, followed by MedGemma-27B-Text at 0.362. On the Multimodal set, MedGemma-27B ranked highest across all metrics. Full results are provided in Table A11.
Compared to the zero-shot setting, factuality improved only for Gemma-2-27B (+0.028) and MedGemma-27B (+0.015) on the Text set, and only for MedGemma-27B (+0.034) on the Multimodal set. To examine this trade-off, we qualitatively analyzed 100 randomly sampled responses from Qwen3-VL-32B on the Multimodal set, where factuality decreased after SFT (Figure A4). After SFT, the model responses became shorter, more generic, and more conservative. These changes improved surface-level similarity but reduced explanatory richness and coverage. This observation aligns with prior findings that a fine-tuned model may mimic response styles while remaining factually unreliable (Gudibande et al., 2024).
6 Conclusion
This study introduces PETQA, a Korean QA benchmark designed to evaluate the veterinary knowledge and clinical reasoning capabilities of LLMs and LVLMs. PETQA comprises both text-only and image-based questions, along with answers provided by expert veterinarians, based on real-world cases involving dogs and cats. PETQA-BENCH, the test set of PETQA, additionally includes annotations for question type and clinical condition. To the best of our knowledge, PETQA is the first long-form QA resource for veterinary medicine. To support the broader NLP community, we release translated versions of PETQA-BENCH in English, German, Chinese, Indonesian, and Arabic.
We conduct benchmarking experiments for eighteen models categorized as closed LVLMs, open-weight LVLMs, and open-weight LLMs. Two traditional metrics and two LLM-as-a-judge metrics are used to measure the alignment between model responses and expert-annotated references and to assess the helpfulness of the responses. The results reveal three key findings. First, closed models generally outperformed open-weight models across the four metrics, with larger gaps observed for the LLM-as-a-judge metrics of factuality and helpfulness. Second, all models showed consistent performance degradation on image-based questions. Third, alternative model adaptation strategies, such as RAG and SFT, yielded inconsistent improvements on both the Text and Multimodal sets. Overall, these benchmarking results highlight the limitations of current models and the need for more effective adaptation methods to develop clinically reliable AI systems for veterinary care.
Limitations
Dataset Coverage Our dataset focuses on two companion animals, dogs and cats, which account for a substantial proportion of real-world pet-related queries. Given Naver Knowledge iN's significant user base, the dataset likely encompasses a wide range of clinical queries about these target animals. As identified in Section 3.3, PETQA-BENCH covers 352 clinical conditions across 4,000 QA pairs, further demonstrating its diversity. Future work could extend the dataset to a broader range of species and investigate the generalizability of our findings across languages. We hope that the data collection, preprocessing, and annotation protocols documented in this study can facilitate the development of resources covering a wider range of species and languages.
Evaluation Metrics Results measured by reference-based metrics may be misleading when the reference answers are incorrect. To assess the reliability of the expert-provided answers, we verified the medical accuracy of responses collected from the online QA platform through manual validation by the fourth author, a veterinary expert holding a Ph.D. (Section 3.2). These results suggest that expert-based quality checks should be incorporated into future efforts to construct similar resources.
Ethical Considerations
This study was approved by the Institutional Review Board at Soongsil University (SSU-202604-HR-805-1).
Copyright and Privacy Issues To comply with the restrictions specified in the Terms of Service of Naver Knowledge iN, we release the dataset for research purposes only under the CC BY-NC-ND 4.0 license, which restricts commercial use and the distribution of derivative works. We manually confirmed that PETQA-BENCH do not contain personally identifiable information.
Annotator Information Label annotation for PETQA-BENCH (Section 3.2) was conducted by six students majoring in AI recruited from two institutions: four master's students and two undergraduate students. The annotation task primarily involved reading text instances and assigning labels. Therefore, the annotation task was considered minimal risk, with no anticipated physical or psychological harm to participants. In compliance with local wage regulations, the annotators were compensated at approximately USD 7 per hour. The quality check described in the same section was performed by a veterinary expert holding a Ph.D. Screenshots of the annotation interfaces are available in Figures A10a and A10b.
AI Assistant Use We used AI-assisted language-editing tools, primarily ChatGPT, exclusively for checking grammar and improving readability.
Acknowledgements
This research was supported by the IITP (Institute of Information & Communications Technology Planning & Evaluation), funded by the Korea government (MSIT) (IITP-2026-RS-2022-00156360, IITP-2026-RS-2024-00430997, IITP-2026-RS-2020-II201602). This work was also supported by a grant from the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, the Republic of Korea (Grant No. HI22C0646). KP and SP are the corresponding authors.
References
Mubashara Akhtar, Michael Schlichtkrull, and Andreas Vlachos. 2026. Ev2r: Evaluating evidence retrieval in automated fact-checking. Transactions of the Association for Computational Linguistics, 14:530–561.
American Pet Products Association. 2025. The american pet products association (appa) releases 2025 state of the industry report.
Soyoung An, Kyunghoon Bae, Eunbi Choi, Kibong Choi, Stanley Jungkyu Choi, Seokhee Hong, Junwon Hwang, Hyojin Jeon, Gerrard Jeongwon Jo, Hyunjik Jo, and 1 others. 2024. Exaone 3.5: Series of large language models for real-world use cases. arXiv preprint arXiv:2412.04862.
Anna Arias-Duart, Pablo Agustin Martin-Torres, Daniel Hinjos, Pablo Bernabeu-Perez, Lucia Urcelay Ganzabal, Marta Gonzalez Mallo, Ashwin Kumar Gurajan, Enrique Lopez-Cuena, Sergio Alvarez-Napagao, and Dario Garcia-Gasulla. 2025. Automatic evaluation of healthcare llms beyond question-answering. In Proceedings of the 2025 Conference of the Nations of the Americas Chapter of the Association for Computational Linguistics: Human Language Technologies (Volume 2: Short Papers), pages 108–130.
Asan Medical Center. n.d. Disease Encyclopedia. Accessed: 2026-04-21.
Shuai Bai, Yuxuan Cai, Ruizhe Chen, Keqin Chen, Xionghui Chen, Zesen Cheng, Lianghao Deng, Wei Ding, Chang Gao, Chunjiang Ge, and 1 others. 2025. Qwen3-vl technical report. arXiv preprint arXiv:2511.21631.
Tim Baumgärtner, Ted Briscoe, and Iryna Gurevych. 2025. Peerqa: A scientific question answering dataset from peer reviews. In Proceedings of the 2025 Conference of the Nations of the Americas Chapter of the Association for Computational Linguistics: Human Language Technologies (Volume 1: Long Papers), pages 508–544.
Seul Ki Choi, Yunseo Moon, and Hyunggu Jung. 2025. Chatgpt and human dietitian responses to diet-related questions on an online q&a platform: A comparative study. Digital Health, 11:20552076251361381.
Alessio Cocchieri, Luca Ragazzi, Giuseppe Tagliavini, and Gianluca Moro. 2026. Remedqa: Are we done with medical multiple-choice benchmarks? In Proceedings of the 19th Conference of the European Chapter of the Association for Computational Linguistics (Volume 1: Long Papers), pages 2706–2738.
Gheorghe Comanici, Eric Bieber, Mike Schaekermann, Ice Pasupat, Noveen Sachdeva, Inderjit Dhillon, Marcel Blistein, Ori Ram, Dan Zhang, Evan Rosen, and
1 others. 2025. Gemini 2.5: Pushing the frontier with advanced reasoning, multimodality, long context, and next generation agentic capabilities. arXiv preprint arXiv:2507.06261.
NAVER Corporation and NAVER Cloud Corporation. 2025. Hyperclova x seed model license agreement.
Sumanth Doddapaneni, Mohammed Safi Ur Rahman Khan, Dilip Venkatesh, Raj Dabre, Anoop Kunchukuttan, and Mitesh M Khapra. 2025. Cross-lingual auto evaluation for assessing multilingual LLMs. In Proceedings of the 63rd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers), pages 29297–29329.
Angela Fan, Yacine Jernite, Ethan Perez, David Grangier, Jason Weston, and Michael Auli. 2019. Eli5: Long form question answering. In Proceedings of the 57th annual meeting of the association for computational linguistics, pages 3558–3567.
Gemma Team. 2025. Gemma 3 technical report. arXiv preprint arXiv:2503.19786.
Ariel Gera, Odellia Boni, Yotam Perlitz, Roy Bar-Haim, Lilach Eden, and Asaf Yehudai. 2025. JuStRank: Benchmarking LLM judges for system ranking. In Proceedings of the 63rd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers), pages 682–712.
Google. 2024. Health ai developer foundations terms of use.
Google. 2026a. Gemma terms of use.
Google. 2026b. Google apis terms of service.
Maxime Griot, Jean Vanderdonckt, Demet Yuksel, and Coralie Hemptinne. 2025. Pattern recognition or medical knowledge? the problem with multiple-choice questions in medicine. In Proceedings of the 63rd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers), pages 5321–5341.
Arnav Gudibande, Eric Wallace, Charlie Victor Snell, Xinyang Geng, Hao Liu, Pieter Abbeel, Sergey Levine, and Dawn Song. 2024. The false promise of imitating proprietary language models. In The Twelfth International Conference on Learning Representations.
Yajie Vera He, Mohita Chowdhury, Jared Joselowitz, Aisling Higham, and Ernest Lim. 2025. ASTRID - an automated and scalable TRIaD for the evaluation of RAG-based clinical question answering systems. In Findings of the Association for Computational Linguistics: ACL 2025, pages 16700–16716.
Dan Hendrycks, Collin Burns, Steven Basart, Andy Zou, Mantas Mazeika, Dawn Song, and Jacob Steinhardt. 2021. Measuring massive multitask language understanding. In International Conference on Learning Representations.
Ruben Hoffmann, Carl Johan Lagerkvist, Malin Hagberg Gustavsson, and Bodil S Holst. 2018. An empirical examination of the conceptualization of companion animals. BMC psychology, 6(1):15.
Pedram Hosseini, Jessica M. Sin, Bing Ren, Bryceton G. Thomas, Elnaz Nouri, Ali Farahanchi, and Saeed Hassanpour. 2024. A benchmark for long-form medical question answering. In Advancements In Medical Foundation Models: Explainability, Robustness, Security, and Beyond.
Edward J Hu, yelong shen, Phillip Wallis, Zeyuan Allen-Zhu, Yuanzhi Li, Shean Wang, Lu Wang, and Weizhu Chen. 2022. LoRA: Low-rank adaptation of large language models. In International Conference on Learning Representations.
Aaron Hurst, Adam Lerer, Adam P Goucher, Adam Perelman, Aditya Ramesh, Aidan Clark, AJ Ostrow, Akila Welihinda, Alan Hayes, Alec Radford, and 1 others. 2024. Gpt-4o system card. arXiv preprint arXiv:2410.21276.
Daniel P Jeong, Saurabh Garg, Zachary Chase Lipton, and Michael Oberst. 2024. Medical adaptation of large language and vision-language models: Are we making progress? In Proceedings of the 2024 Conference on Empirical Methods in Natural Language Processing, pages 12143–12170.
Di Jin, Eileen Pan, Nassim Oufattole, Wei-Hung Weng, Hanyi Fang, and Peter Szolovits. 2021. What disease does this patient have? a large-scale open domain question answering dataset from medical exams. Applied Sciences, 11(14):6421.
Qiao Jin, Bhuwan Dhingra, Zhengping Liu, William Cohen, and Xinghua Lu. 2019. Pubmedqa: A dataset for biomedical research question answering. In Proceedings of the 2019 conference on empirical methods in natural language processing and the 9th international joint conference on natural language processing (EMNLP-IJCNLP), pages 2567–2577.
Qiao Jin, Zheng Yuan, Guangzhi Xiong, Qianlan Yu, Huaiyuan Ying, Chuanqi Tan, Mosha Chen, Songfang Huang, Xiaozhong Liu, and Sheng Yu. 2022. Biomedical question answering: a survey of approaches and challenges. ACM Computing Surveys (CSUR), 55(2):1–36.
Korea Pharmaceutical Information Center. n.d. Disease Information. Accessed: 2026-04-21.
Klaus Krippendorff. 2018. Content analysis: An introduction to its methodology. Sage publications.
Sunjun Kweon, Byungjin Choi, Gyouk Chu, Junyeong Song, Daeun Hyeon, Sujin Gan, Jueon Kim, Minkyu Kim, Rae Woong Park, and Edward Choi. 2024. Kormedmcqa: Multi-choice question answering benchmark for korean healthcare professional licensing examinations. arXiv preprint arXiv:2403.01469.
Woosuk Kwon, Zhuohan Li, Siyuan Zhuang, Ying Sheng, Lianmin Zheng, Cody Hao Yu, Joseph Gonzalez, Hao Zhang, and Ion Stoica. 2023. Efficient memory management for large language model serving with pagedattention. In Proceedings of the 29th symposium on operating systems principles, pages 611–626.
Jihyung Lee, Daehui Kim, Seonjeong Hwang, Hyounghun Kim, and Gary Lee. 2025. Koblex: Open legal question answering with multi-hop reasoning. In Proceedings of the 2025 Conference on Empirical Methods in Natural Language Processing, pages 4019–4053.
Patrick Lewis, Ethan Perez, Aleksandra Piktus, Fabio Petroni, Vladimir Karpukhin, Naman Goyal, Heinrich Küttler, Mike Lewis, Wen-tau Yih, Tim Rocktäschel, Sebastian Riedel, and Douwe Kiela. 2020. Retrieval-augmented generation for knowledge-intensive nlp tasks. In Advances in Neural Information Processing Systems, volume 33, pages 9459–9474. Curran Associates, Inc.
Chunyuan Li, Cliff Wong, Sheng Zhang, Naoto Usuyama, Haotian Liu, Jianwei Yang, Tristan Naumann, Hoifung Poon, and Jianfeng Gao. 2023. LLaVA-med: Training a large language-and-vision assistant for biomedicine in one day. In Thirty-seventh Conference on Neural Information Processing Systems Datasets and Benchmarks Track.
Haonan Li, Martin Tomko, Maria Vasardani, and Timothy Baldwin. 2022. Multispanqa: A dataset for multi-span question answering. In Proceedings of the 2022 conference of the North American chapter of the association for computational linguistics: human language technologies, pages 1250–1260.
Jing Li, Shangping Zhong, and Kaizhi Chen. 2021. Mlec-qa: A chinese multi-choice biomedical question answering dataset. In Proceedings of the 2021 Conference on Empirical Methods in Natural Language Processing, pages 8862–8874.
Chin-Yew Lin. 2004. ROUGE: A package for automatic evaluation of summaries. In Text Summarization Branches Out, pages 74–81, Barcelona, Spain. Association for Computational Linguistics.
Junling Liu, Peilin Zhou, Yining Hua, Dading Chong, Zhongyu Tian, Andrew Liu, Helin Wang, Chenyu You, Zhenhua Guo, Zhu Lei, and Michael Lingzhi Li. 2023. Benchmarking large language models on CMExam - a comprehensive chinese medical exam dataset. In Thirty-seventh Conference on Neural Information Processing Systems Datasets and Benchmarks Track.
Mianxin Liu, Weiguo Hu, Jinru Ding, Jie Xu, Xiaoyang Li, Lifeng Zhu, Zhian Bai, Xiaoming Shi, Benyou Wang, Haitao Song, and 1 others. 2024. Medbench: A comprehensive, standardized, and reliable benchmarking system for evaluating chinese medical large language models. Big Data Mining and Analytics, 7(4):1116–1128.
Zheheng Luo, Chenhan Yuan, Qianqian Xie, and Sophia Ananiadou. 2025. Empec: A comprehensive benchmark for evaluating large language models across diverse healthcare professions. In Findings of the Association for Computational Linguistics: ACL 2025, pages 9945–9958.
Itay Manes, Naama Ronn, David Cohen, Ran Ilan Ber, Zehavi Horowitz-Kugler, and Gabriel Stanovsky. 2024. K-qa: A real-world medical q&aa benchmark. In Proceedings of the 23rd Workshop on Biomedical Natural Language Processing, pages 277–294.
Sewon Min, Kalpesh Krishna, Xinxi Lyu, Mike Lewis, Wen-tau Yih, Pang Koh, Mohit Iyyer, Luke Zettle-moyer, and Hannaneh Hajishirzi. 2023. Factscore: Fine-grained atomic evaluation of factual precision in long form text generation. In Proceedings of the 2023 Conference on Empirical Methods in Natural Language Processing, pages 12076–12100.
Ministry of Agriculture, Food and Rural Affairs. 2025. Standardized Animal Disease Classification. Accessed: 2026-04-21.
Saif Mohammad. 2012. #emotional tweets. In *SEM 2012: The First Joint Conference on Lexical and Computational Semantics – Volume 1: Proceedings of the main conference and the shared task, and Volume 2: Proceedings of the Sixth International Workshop on Semantic Evaluation (SemEval 2012), pages 246–255, Montréal, Canada. Association for Computational Linguistics.
NAVER. 2025a. Hyperclovax-seed-text-instruct-1.5b.
NAVER. 2025b. Hyperclovax-seed-vision-instruct-3b.
Vincent Nguyen, Sarvnaz Karimi, Maciej Rybinski, and Zhenchang Xing. 2023. Medredqa for medical consumer question answering: Dataset, tasks, and neural baselines. In Proceedings of the 13th International Joint Conference on Natural Language Processing and the 3rd Conference of the Asia-Pacific Chapter of the Association for Computational Linguistics (Volume 1: Long Papers), pages 629–648.
OpenAI. 2026. Openai terms of use.
Ankit Pal, Logesh Kumar Umapathi, and Malaikanan Sankarasubbu. 2022. Medmcqa: A large-scale multi-subject multi-choice dataset for medical domain question answering. In Conference on health, inference, and learning, pages 248–260. PMLR.
Eunjeong L. Park and Sungzoon Cho. 2014. Konlpy: Korean natural language processing in python. In Proceedings of the 26th Annual Conference on Human & Cognitive Language Technology, Chuncheon, Korea.
Sungjoon Park, Jihyung Moon, Sungdong Kim, Won Ik Cho, Jiyoon Han, Jangwon Park, Chisung Song, Junseong Kim, Yongsook Song, Taehwan Oh, Joohong Lee, Juhyun Oh, Sungwon Lyu, Younghoon Jeong, Inkwon Lee, Sangwoo Seo, Dongjun Lee, Hyunwoo
Kim, Myeonghwa Lee, and 12 others. 2021. Klue: Korean language understanding evaluation. Preprint, arXiv:2105.09680.
Qwen Team. 2025. Qwen3 technical report. Preprint, arXiv:2505.09388.
LG AI Research. 2024. Exaone ai model license agreement 1.1 - nc.
Royal Society for the Prevention of Cruelty to Animals. 2026. Kindness index 2026: Key findings.
Florian Schneider and Sunayana Sitaram. 2024. M5 – a diverse benchmark to assess the performance of large multimodal models across multilingual and multicultural vision-language tasks. In Findings of the Association for Computational Linguistics: EMNLP 2024, pages 4309–4345.
Karan Singhal, Shekoofeh Azizi, Tao Tu, S Sara Mahdavi, Jason Wei, Hyung Won Chung, Nathan Scales, Ajay Tanwani, Heather Cole-Lewis, Stephen Pfohl, and 1 others. 2023. Large language models encode clinical knowledge. Nature, 620(7972):172–180.
SKT AI Model Lab. 2025a. A.x 4.0 light.
SKT AI Model Lab. 2025b. A.x 4.0 vl light.
Zhi Rui Tam, Yung-Yu Shih, Yen-Wei Lee, Ya-Ting Pai, Wen Yu Chang, and Yun-Nung Chen. 2026. VisTW: Benchmarking vision-language models for Taiwanese Mandarin in Taiwan. In Findings of the Association for Computational Linguistics: ACL 2026, pages 36711–36756.
Gemma Team, Morgane Riviere, Shreya Pathak, Pier Giuseppe Sessa, Cassidy Hardin, Surya Bhupatiraju, Léonard Hussenot, Thomas Mesnard, Bobak Shahriari, Alexandre Ramé, and 1 others. 2024. Gemma 2: Improving open language models at a practical size. arXiv preprint arXiv:2408.00118.
Steven Tresker. 2020. A typology of clinical conditions. Studies in History and Philosophy of Science Part C: Studies in History and Philosophy of Biological and Biomedical Sciences, 83:101291.
George Tsatsaronis, Georgios Balikas, Prodromos Malakasiotis, Ioannis Partalas, Matthias Zschunke, Michael R Alvers, Dirk Weissenborn, Anastasia Krithara, Sergios Petridis, Dimitris Polychronopoulos, and 1 others. 2015. An overview of the bioasq large-scale biomedical semantic indexing and question answering competition. BMC bioinformatics, 16(1):138.
Yindong Wang, Martin Preiß, Margarita Bugueño, Jan Vincent Hoffbauer, Abdullatif Ghajar, Tolga Buz, and Gerard De Melo. 2026. Refact: A benchmark for scientific confabulation detection with positional error annotations. In Proceedings of the 19th Conference of the European Chapter of the Association for Computational Linguistics (Volume 1: Long Papers), pages 8174–8187.
Yinuo Wang, Baiyang Wang, Robert Mercer, Frank Rudzicz, Sudipta Singha Roy, Pengjie Ren, Zhumin Chen, and Xindi Wang. 2025. Trustworthy medical question answering: An evaluation-centric survey. In Proceedings of the 2025 Conference on Empirical Methods in Natural Language Processing, pages 27477–27490.
Junde Wu, Jiayuan Zhu, Yunli Qi, Jingkun Chen, Min Xu, Filippo Menolascina, Yueming Jin, and Vicente Grau. 2025. Medical graph rag: Evidence-based medical large language model via graph retrieval-augmented generation. In Proceedings of the 63rd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers), pages 28443–28467.
Jiajie Zhang, Zhongni Hou, Xin Lv, Shulin Cao, Zhenyu Hou, Yilin Niu, Lei Hou, Yuxiao Dong, Ling Feng, and Juanzi Li. 2025a. Longreward: Improving long-context large language models with ai feedback. In Proceedings of the 63rd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers), pages 3718–3739.
Ming Zhang, Yujiong Shen, Zelin Li, Huayu Sha, Binze Hu, Yuhui Wang, Chenhao Huang, Shichun Liu, Jingqi Tong, Changhao Jiang, Mingxu Chai, Zhiheng Xi, Shihan Dou, Tao Gui, Qi Zhang, and Xuanjing Huang. 2025b. LLMEval-Med: A real-world clinical benchmark for medical LLMs with physician validation. In Findings of the Association for Computational Linguistics: EMNLP 2025.
Tianyi Zhang, Varsha Kishore, Felix Wu, Kilian Q. Weinberger, and Yoav Artzi. 2020. Bertscore: Evaluating text generation with bert. In International Conference on Learning Representations.
Yanzhao Zhang, Mingxin Li, Dingkun Long, Xin Zhang, Huan Lin, Baosong Yang, Pengjun Xie, An Yang, Dayiheng Liu, Junyang Lin, Fei Huang, and Jingren Zhou. 2025c. Qwen3 embedding: Advancing text embedding and reranking through foundation models. arXiv preprint arXiv:2506.05176.
Yuxin Zuo, Shang Qu, Yifei Li, Zhang-Ren Chen, Xuekai Zhu, Ermo Hua, Kaiyan Zhang, Ning Ding, and Bowen Zhou. 2025. MedxpertQA: Benchmarking expert-level medical reasoning and understanding. In Forty-second International Conference on Machine Learning.
A Artifact Usage
All artifacts, including datasets, reference materials, and evaluation packages, were used strictly for non-commercial research and evaluation purposes. Below, we document the scope and use of our artifacts and confirm that their use is consistent with their intended purposes.
A.1 Source Data
Veterinary QA Data PETQA consists of Korean veterinary long-form QA data collected from publicly accessible Naver Knowledge iN pages. The data focus on clinical consultations for companion animals, specifying dogs and cats. Before data collection, we reviewed the platform's terms of service and posting policy². According to these policies, the copyright of user-generated posts belongs to the original authors, and the platform permits limited use for service operation, search, and research-related purposes³. In accordance with these policies and prior work (Choi et al., 2025), we de-identified the collected data by removing personally identifiable information and do not redistribute the original raw posts.
Retrieval Corpus The retrieval corpus was constructed from an English-language veterinary reference book intended for professional veterinary education and commonly used in clinical practice.⁴ The book was used solely as an external knowledge source for retrieval-augmented evaluation and was not used for model training.
Clinical Condition To support clinical condition annotation, we additionally used Korean veterinary and medical reference resources, including the official animal disease classification system (Ministry of Agriculture, Food and Rural Affairs, 2025), disease encyclopedias (Asan Medical Center, n.d.), and disease information resources (Korea Pharmaceutical Information Center, n.d.). These resources were used only internally for annotation and terminology normalization. We do not redistribute their original webpage content or any source text as part of the dataset or research artifacts.
A.2 License
We report the explicitly stated licenses or terms associated with the models used in this work.
The GPT model series were used in compliance with the OpenAI Terms of Use (OpenAI, 2026). Gemini models (Comanici et al., 2025) were used in compliance with the Google APIs Terms of Service (Google, 2026b). Qwen3 (Zhang et al., 2025c; Bai et al., 2025; Qwen Team, 2025) and A.X models (SKT AI Model Lab, 2025a,b) are available under the Apache License 2.0. Gemma models (Team
et al., 2024; Gemma Team, 2025) are available under the Gemma Terms of Use (Google, 2026a). MedGemma models are available under the Health AI Developer Foundations Terms of Use (Google, 2024). HCX models (NAVER, 2025b,a) are available under the HyperCLOVA X SEED Model License Agreement (Corporation and Corporation, 2025). EXAONE-3.5-32B (An et al., 2024) is available under the EXAONE AI Model License Agreement 1.1 - NC (Research, 2024). KLUE-RoBERTa-base (Park et al., 2021) is available under the CC BY-SA 4.0 license.
B Dataset Details
Raw Data Collection We collected posts from Naver Knowledge iN through keyword- and profile-based strategies. First, we searched for dog- and cat-related keywords appearing in questions and answers. Second, we collected posts from verified experts' profile pages, ensuring that each post contained at least one expert answer. Each post was crawled using Selenium⁵, and its HTML was parsed with BeautifulSoup⁶. We extracted the question title and body, all answers, answer selection status, board information, hashtags, and expert verification status.
Animal Type Classification To distinguish dog- and cat-related posts, we used a two-stage pipeline combining hashtag-based labeling and text classification. Posts matching hashtags from only one of the two lists containing the 100 most frequent dog- and cat-related hashtags were labeled accordingly, with the hashtags serving as weak labels (Mohammad, 2012). The remaining posts were classified as dog, cat, or neutral using two fine-tuned KLUE-RoBERTa-base models, each trained separately on posts with and without images. After removing URLs, we used the question title, body, and selected answer as input. Neutral examples were drawn from seven non-target animal boards, and posts classified as neutral were excluded from the dataset.
Training and Validation Set Statistics Table A1 provides descriptive statistics for the training and validation sets.
²https://kin.naver.com/common/guide.naver?query=p3 ³https://policy.naver.com/policy/service.html ⁴Legal constraints prevent us from disclosing the title.
⁵https://www.selenium.dev/ ⁶https://www.crummy.com/software/BeautifulSoup/
| Metric | Train | Validation | ||
|---|---|---|---|---|
| Text | Multimodal | Text | Multimodal | |
| Target species | ||||
| Dog | 5,098 | 3,871 | 1,675 | 1,595 |
| Cat | 978 | 880 | 325 | 405 |
| Text tokens | ||||
| Questions | ||||
| - Max. | 971 | 1016 | 1339 | 1128 |
| - Mean. | 145.3 | 107.9 | 142.6 | 110.7 |
| - Min. | 10 | 6 | 10 | 9 |
| Answers | ||||
| - Max. | 544 | 785 | 396 | 761 |
| - Mean. | 120.9 | 139.0 | 119.2 | 139.9 |
| - Min. | 6 | 7 | 11 | 17 |
Table A1: Descriptive statistics of PETQA for the train and validation sets.
C Evaluation Metrics
Following Section 4.3, we describe the implementation details and protocols for all metrics. For LLM-as-a-judge evaluations, we used a fixed random seed of 42 and a temperature of 0 to ensure reproducibility and consistency across evaluations. All LLM-based evaluations were conducted using the batch API, and the evaluation prompts are provided in Appendix G.
ROUGE We computed ROUGE (Lin, 2004) using the rouge Python package (v1.0.1). To better reflect Korean morphology, we tokenized both reference answers. We generated answers at the morpheme level using KoNLPy (v0.6.0) (Park and Cho, 2014) with the Okt tokenizer, and computed ROUGE on the resulting whitespace-joined morpheme sequences. We reported the mean F1 score over all examples.
BERTScore We computed BERTScore (Zhang et al., 2020) using the bert-score package (v0.3.13). We used the official Python API with the default multilingual checkpoint (bert-base-multilingual-cased), and reported the mean F1 score over all examples.
Factuality We evaluated factuality using a reference-based metric (Akhtar et al., 2026), with Gemini 2.5 Flash as the judge model due to its comparable agreement with human judgments and greater cost efficiency, as shown in Table A3. Following FactScore (Min et al., 2023), the judge decomposed the reference answer () and model output () into atomic fact sets and , respectively. We computed precision () as the proportion of generated facts supported by the reference and recall () as the proportion of reference facts covered by the model output:
where denotes the indicator function. We reported the mean F1 score as the primary factuality metric, capturing both the factual accuracy and completeness of generated answers. We used a thinking budget of 0 and a maximum output length of 8,192 tokens. The prompt is shown in Figure A6.
Helpfulness We evaluated helpfulness using a reference-free metric. Following Zhang et al. (2025a), we provided the judge model with detailed scoring criteria and examples for each score level. Given a question and model response, the judge model assigns a score and generates a brief rationale. The prompt is shown in Figure A7.
To select the judge model, we randomly sampled 100 responses from each set and manually annotated them on a five-point Likert scale. We reported the mean helpfulness score and used a maximum output length of 1,024 tokens. As shown in Table A2, GPT-4o exhibited the highest overall correlation and was therefore selected. It matched the human scores exactly for 58 samples and differed by at most one point for an additional 38 samples. Although the modest correlation does not necessarily imply that system-level comparisons are unreliable, as discussed in prior work (Gera et al., 2025), the helpfulness results should be interpreted with caution and further validated in future work.
Partial Match Following Li et al. (2022), we evaluated predicted and gold clinical condition spans using partial matching. We used EXAONE-3.5-32B to extract predicted conditions from model responses. Let and denote the -th predicted and -th gold condition, respectively. To account for minor span variations, we define their retrieval and relevance overlap scores using the longest common substring (LCS):
| Judge Model | Pearson | Spearman | Kendall |
|---|---|---|---|
| GPT-4o | 0.2255 | 0.2239 | 0.2144 |
| GPT-5 | 0.1544 | 0.2218 | 0.2097 |
| Gemini 2.5 Pro | 0.0967 | 0.1231 | 0.1149 |
| EXAONE-3.5-32B | -0.1097 | -0.0781 | -0.0771 |
Table A2: Correlation between human evaluation scores and LLM-as-a-judge scores for helpfulness.
| Judge Model | Pearson | Spearman |
|---|---|---|
| Gemini 2.5 Pro | 0.4087 | 0.3922 |
| Gemini 2.5 Flash | 0.4065 | 0.3784 |
| GPT-4o-mini | 0.1514 | 0.0995 |
Table A3: Correlations between human evaluation scores and LLM-as-a-judge factuality scores for the factuality.
Given predicted and gold conditions, partial precision and recall are computed as:
We reported their harmonic mean as the micro-averaged F1 score.
D Experimental Setups
Computing Environment Experiments were conducted on two separate computing environments. The first system was equipped with three NVIDIA RTX A6000 GPUs (48 GB of VRAM each) and 128 GB of system memory, while the second system consisted of a single NVIDIA H200 GPU (141 GB of VRAM) and 2 TB of system memory. All experiments were performed using Python 3.12.0, PyTorch 2.8.0, Transformers 4.57.3, and vLLM 0.11.0.
Models Table A4 summarizes the model IDs and parameter sizes of the models used in our experiments. Following practices adopted in previous studies (Lee et al., 2025), we disabled reasoning (or thinking) modes for models that support explicit reasoning functionalities (e.g., the Qwen3 and Gemini 2.5 families).
Inference and Training Settings For all open-weight models, inference was conducted using vLLM (Kwon et al., 2023) with a fixed random seed of 42, a temperature of 0, a repetition penalty of 1.05, and a maximum generation length

Figure A1: Clinical condition inclusion performance on the Multimodal set.
of 512 tokens. For RAG, the top six passages were retrieved from a FAISS index implemented with LangChain using embeddings generated by Qwen3-Embedding-8B. Documents were divided into 1,024-token chunks with an overlap of 100 tokens.
For parameter-efficient fine-tuning, we used LoRA (Hu et al., 2022) with a rank () of 16, a dropout rate of 0.05, and an value of 32. Models were trained for two epochs using AdamW with a learning rate of , a weight decay of 0.01, a warmup ratio of 0.1, four gradient accumulation steps, and a batch size of 8. Training and inference required approximately 15 and 12 GPU hours, respectively.
E Case Study
RAG Figures A2 and A3 compare model responses under the zero-shot and RAG settings using representative successful and failed cases, respectively.
SFT Figure A4 compares model responses under the zero-shot and SFT settings and analyzes their differences.
F Supplementary Results
Clinical Condition Inclusion In Section 5.1.2, we assessed whether model responses included clinical conditions for the samples in the Text set using the partial match (PM) score. Here, we present the corresponding results for the Multimodal set, as shown in Figure A1. Results indicated that Gemini 2.5 Pro performed best, followed by GPT-4.1 and Gemma-3-27B. An analysis of 958 diagnosis responses generated by Gemini 2.5 Pro with non-empty ground-truth clinical conditions revealed a similar trend across the
| Model | Model ID | Params |
|---|---|---|
| Closed large vision-language models | ||
| GPT-4.1 mini | gpt-4.1-mini-2025-04-14 | — |
| GPT-4.1 | gpt-4.1-2025-04-14 | — |
| Gemini 2.5 Flash | gemini-2.5-flash | — |
| Gemini 2.5 Pro | gemini-2.5-pro | — |
| Open-weight large vision-language models | ||
| Qwen3-VL-8B | Qwen/Qwen3-VL-8B-Instruct | 8B |
| Qwen3-VL-32B | Qwen/Qwen3-VL-32B-Instruct | 32B |
| Gemma-3-12B | google/gemma-3-12b-it | 12B |
| Gemma-3-27B | google/gemma-3-27b-it | 27B |
| MedGemma-27B | google/medemma-27b-it | 27B |
| A.X-4.0-VL-Light | skt/A.X-4.0-VL-Light | 8B |
| HCX-SEED-Vision-3B | naver-hyperclovax/HyperCLOVAX-SEED-Vision-Instruct-3B | 3B |
| Open-weight large language models | ||
| Qwen3-8B | Qwen/Qwen3-8B | 8B |
| Qwen3-32B | Qwen/Qwen3-32B | 32B |
| Gemma-2-9B | google/gemma-2-9b-it | 9B |
| Gemma-2-27B | google/gemma-2-27b-it | 27B |
| MedGemma-27B-Text | google/medemma-27b-text-it | 27B |
| A.X-4.0-Light | skt/A.X-4.0-Light | 7B |
| HCX-SEED-Text-1.5B | naver-hyperclovax/HyperCLOVAX-SEED-Text-Instruct-1.5B | 1.5B |
Table A4: Models used in experiments, along with their corresponding model identifiers and parameter sizes.
four evaluation metrics. The matched group obtained higher ROUGE (0.259>0.241), BERTScore (0.731>0.723), factuality (0.574>0.484), and helpfulness (4.836>4.764).
Controlling for Question-Type Distribution To assess whether differences in question-type distributions account for the lower performance on the Multimodal set relative to the Text set, we compared performance between the two sets after controlling for question type. First, we restricted the analysis to diagnosis questions (Text: 1,231; Multimodal: 1,699). Second, we resampled 2,000 instances with replacement from the Text set to match the question-type distribution of the Multimodal set (diagnosis: 85%, treatment: 6%, basic veterinary knowledge: 3%, miscellaneous: 6%).
As shown in Table A6, the Text > Multimodal trend remained consistent in both analyses, with all paired comparisons being statistically significant according to one-sided Wilcoxon signed-rank tests (p<0.05). These analyses further support the finding in Section 5.1 that LVLMs underperform on the Multimodal set, suggesting that the observed performance gap is more likely attributable to the greater difficulty of multimodal questions than to differences in question-type distributions.
Factuality Breakdown into Precision and Recall Factuality is an F1 score that combines precision and recall to quantify the alignment between the model response and the reference answer. To better understand the relative contributions of these two components to factuality across models, we present the zero-shot breakdown in Table A5. Precision is lower than recall in 26 of the 29 comparisons, with a generally larger gap on the Text set than on the Multimodal set. This trend suggests that model responses often contain information unsupported by the reference answer, even when they capture much of the information present in the reference.
Effects of Enhanced Reasoning We examined the effects of enhanced reasoning on veterinary QA performance. Table A7 shows the zero-shot performance of Qwen3 and Gemini 2.5 models with enhanced reasoning enabled. Specifically, we set enable_thinking=True for Qwen3 and thinking_budget=256 for Gemini 2.5. The results indicate that enhanced reasoning consistently improved the helpfulness scores, whereas ROUGE, BERTScore, and factuality showed varying trends across models and modalities.
Benchmarking in More Languages We additionally conducted benchmarking experiments using the translated versions of PETQA-BENCH in five languages: English, German, Chinese, Indonesian, and Arabic. We first validated translation quality following the protocol of Doddapaneni et al.
| Model | Text | Multimodal | ||||
|---|---|---|---|---|---|---|
| P | R | F1 | P | R | F1 | |
| Closed large vision-language models | ||||||
| GPT-4.1 mini | 0.528 | 0.647 | 0.551 | 0.562 | 0.572 | 0.531 |
| GPT-4.1 | 0.535 | 0.678 | 0.569 | 0.538 | 0.590 | 0.531 |
| Gemini 2.5 Flash | 0.493 | 0.682 | 0.541 | 0.479 | 0.586 | 0.495 |
| Gemini 2.5 Pro | 0.502 | 0.679 | 0.550 | 0.512 | 0.625 | 0.524 |
| Open-weight large vision-language models | ||||||
| Qwen3-VL-8B | 0.503 | 0.562 | 0.499 | 0.589 | 0.435 | 0.461 |
| Qwen3-VL-32B | 0.460 | 0.659 | 0.513 | 0.468 | 0.584 | 0.489 |
| Gemma-3-12B | 0.489 | 0.609 | 0.510 | 0.521 | 0.523 | 0.490 |
| Gemma-3-27B | 0.475 | 0.646 | 0.519 | 0.497 | 0.564 | 0.496 |
| MedGemma-27B | 0.450 | 0.662 | 0.503 | 0.422 | 0.546 | 0.442 |
| A.X-4.0-VL-Light | 0.487 | 0.547 | 0.482 | 0.523 | 0.469 | 0.461 |
| HCX-SEED-Vision-3B | 0.507 | 0.552 | 0.493 | 0.530 | 0.455 | 0.451 |
| Open-weight large language models | ||||||
| Qwen3-8B | 0.536 | 0.560 | 0.514 | |||
| Qwen3-32B | 0.508 | 0.623 | 0.530 | |||
| Gemma-2-9B | 0.522 | 0.587 | 0.518 | |||
| Gemma-2-27B | 0.464 | 0.599 | 0.489 | |||
| MedGemma-27B-Text | 0.517 | 0.650 | 0.546 | |||
| A.X-4.0-Light | 0.488 | 0.585 | 0.502 | |||
| HCX-SEED-Text-1.5B | 0.499 | 0.534 | 0.483 | |||
Table A5: Breakdown of factuality into precision and recall.
| Metric | Text | Multimodal |
|---|---|---|
| Diagnosis questions only | ||
| ROUGE | 0.2807 | 0.2298 |
| BERTScore | 0.7360 | 0.7196 |
| Factuality | 0.5560 | 0.5005 |
| Helpfulness | 4.5557 | 4.3285 |
| Shared question type distribution | ||
| ROUGE | 0.2798 | 0.2303 |
| BERTScore | 0.7353 | 0.7189 |
| Factuality | 0.5413 | 0.4893 |
| Helpfulness | 4.5522 | 4.3157 |
Table A6: Comparison of mean performance on PETQA-BENCH after controlling for question type. The first analysis includes only diagnosis questions. The second applies the Multimodal set's question type distribution to both sets.
(2025). For 100 randomly sampled instances in each target language, we used GPT-4o to assign a binary validity label indicating whether each translation preserved the intended meaning without major errors. The resulting validity rates were 98% for English and Indonesian, 97% for German and Chinese, and 96% for Arabic.
We report ROUGE and BERTScore for all five languages. BERTScore was computed using bert-base-multilingual-cased, and ROUGE was computed using character-level tokenization for Chinese and whitespace tokenization for the other languages. We used the LLM-as-a-judge metrics only for English for two reasons. First, the factuality metric was originally proposed and tested in English (Akhtar et al., 2026). Second, LLM-as-a-judge evaluation has been studied more extensively in English than in other languages. Because we did not separately validate the helpfulness metric on the translated English version of PETQA-BENCH, the English helpfulness results should be interpreted with caution. Future studies could validate LLM-as-a-judge metrics for other languages.
Tables A8 and A9 present the zero-shot evaluation results across five languages. The main findings observed in Table 3 generally persisted: closed models achieved the highest performance, and LVLMs underperformed on the Multimodal set in most cases. Although score differences were observed across languages, we refrain from drawing conclusions from these differences because the evaluation metrics were not implemented identically across languages.
G Prompts
This section presents the prompts used in our experiments. All prompts were originally written in Korean, except for the judge prompts used to evaluate the English version of PETQA-BENCH, which
| Model | ROUGE | BERTScore | Factuality | Helpfulness |
|---|---|---|---|---|
| Text | ||||
| Qwen3-8B | 0.294 | 0.746 | 0.514 | 3.754 |
| w/ Reasoning | 0.256 | 0.727 | 0.502 | 4.527 |
| Qwen3-32B | 0.282 | 0.742 | 0.530 | 4.433 |
| w/ Reasoning | 0.250 | 0.727 | 0.504 | 4.779 |
| Multimodal | ||||
| Qwen3-VL-8B | 0.204 | 0.721 | 0.461 | 3.076 |
| w/ Reasoning | 0.197 | 0.716 | 0.484 | 3.794 |
| Gemini 2.5 Flash | 0.224 | 0.709 | 0.495 | 4.679 |
| w/ Reasoning | 0.225 | 0.714 | 0.526 | 4.767 |
Table A7: Effects of enhanced reasoning on veterinary QA performance.
| Model | Text | Multimodal | ||||||
|---|---|---|---|---|---|---|---|---|
| ROUGE | BERTScore | Factuality | Helpfulness | ROUGE | BERTScore | Factuality | Helpfulness | |
| Closed large vision-language models | ||||||||
| GPT-4.1 mini | 0.226 | 0.725 | 0.509 | 4.886 | 0.211 | 0.708 | 0.473 | 4.766 |
| GPT-4.1 | 0.223 | 0.722 | 0.526 | 4.928 | 0.206 | 0.706 | 0.482 | 4.795 |
| Gemini 2.5 Flash | 0.211 | 0.722 | 0.507 | 4.636 | 0.191 | 0.700 | 0.448 | 4.226 |
| Gemini 2.5 Pro | 0.213 | 0.718 | 0.518 | 4.912 | 0.207 | 0.708 | 0.496 | 4.678 |
| Open-weight large vision-language models | ||||||||
| Qwen3-VL-8B | 0.198 | 0.716 | 0.475 | 4.378 | 0.177 | 0.700 | 0.422 | 3.837 |
| Qwen3-VL-32B | 0.210 | 0.717 | 0.483 | 4.888 | 0.195 | 0.701 | 0.440 | 4.827 |
| Gemma-3-12B | 0.190 | 0.711 | 0.496 | 4.769 | 0.189 | 0.704 | 0.456 | 4.462 |
| Gemma-3-27B | 0.184 | 0.706 | 0.485 | 4.914 | 0.184 | 0.702 | 0.452 | 4.689 |
| MedGemma-27B | 0.198 | 0.715 | 0.487 | 4.757 | 0.193 | 0.705 | 0.414 | 4.370 |
| A.X-4.0-VL-Light | 0.216 | 0.724 | 0.448 | 3.988 | 0.193 | 0.707 | 0.411 | 3.927 |
| HCX-SEED-Vision-3B | 0.211 | 0.719 | 0.428 | 3.807 | 0.215 | 0.709 | 0.394 | 3.832 |
| Open-weight large language models | ||||||||
| Qwen3-8B | 0.238 | 0.730 | 0.489 | 4.157 | ||||
| Qwen3-32B | 0.217 | 0.722 | 0.492 | 4.702 | ||||
| Gemma-2-9B | 0.213 | 0.719 | 0.493 | 4.192 | ||||
| Gemma-2-27B | 0.207 | 0.717 | 0.502 | 4.304 | ||||
| MedGemma-27B-Text | 0.198 | 0.717 | 0.515 | 4.843 | ||||
| A.X-4.0-Light | 0.213 | 0.721 | 0.461 | 4.264 | ||||
| HCX-SEED-Text-1.5B | 0.217 | 0.724 | 0.422 | 3.542 | ||||
Table A8: Zero-shot performance on the English version of PETQA-BENCH. Bold and underlined indicate the best and second-best results, respectively.
were written in English. For accessibility, we provide English translations of the prompts used in our experiments in this manuscript, while the original Korean prompts are available in our GitHub repository. Figure A5 shows the prompt used for LLM-based preprocessing (Section 3.1). The LLM-as-a-judge prompts for factuality and helpfulness evaluation are presented in Figures A6 and A7. Figures A8 and A9 show the prompts used for the zero-shot and RAG settings, respectively. We used the same zero-shot prompt for SFT.
H Human Validation
LLM-based Preprocessing We manually evaluated 100 randomly sampled QA pairs to validate the LLM-based preprocessing. One author compared each original and preprocessed pair using two criteria: coherence, whether the preprocessed output remained logical, grammatical, and natural; and completeness, whether essential clinical information, including symptoms, diseases, and pet metadata was preserved.
Question Type and Clinical Condition Figure A10a shows the interface used to assign a question type and, for Diagnosis questions, to annotate clinical conditions in the selected answer. Exact string matches were automatically pre-annotated, and annotators manually added conditions missed by the matching procedure due to surface-form variations, including differences in spacing, spelling, and suffixes.
Expert Verification Using the interface shown in Figure A10b, the expert identified factual errors and potentially misleading clinical statements as the primary causes of incorrect cases. The observed correctness rate was comparable to the 86% expert-verified accuracy reported in a prior medical QA benchmark (Zhang et al., 2025b). We additionally assessed the sensitivity of model rankings by comparing results computed using all audited references with those computed using only the medically correct subset. The Spearman rank correlations were 0.936 for ROUGE and factuality, 0.973 for BERTScore, and 0.975 for helpfulness. These high correlations suggest that excluding incorrect references did not affect the overall ranking.
| Model | Text | Multimodal | ||
|---|---|---|---|---|
| ROUGE | BERTScore | ROUGE | BERTScore | |
| Closed large vision-language models | ||||
| GPT-4.1 mini | 0.235 | 0.731 | 0.195 | 0.715 |
| GPT-4.1 | 0.237 | 0.730 | 0.197 | 0.715 |
| Gemini 2.5 Flash | 0.237 | 0.723 | 0.188 | 0.702 |
| Gemini 2.5 Pro | 0.214 | 0.720 | 0.187 | 0.710 |
| Open-weight large vision-language models | ||||
| Qwen3-VL-8B | 0.198 | 0.719 | 0.179 | 0.711 |
| Qwen3-VL-32B | 0.212 | 0.725 | 0.182 | 0.711 |
| Gemma-3-12B | 0.218 | 0.722 | 0.192 | 0.710 |
| Gemma-3-27B | 0.220 | 0.724 | 0.195 | 0.714 |
| MedGemma-27B | 0.223 | 0.721 | 0.190 | 0.706 |
| A.X-4.0-VL-Light | 0.211 | 0.719 | 0.187 | 0.709 |
| HCX-SEED-Vision-3B | 0.205 | 0.707 | 0.182 | 0.689 |
| Open-weight large language models | ||||
| Qwen3-8B | 0.231 | 0.731 | ||
| Qwen3-32B | 0.224 | 0.728 | ||
| Gemma-2-9B | 0.227 | 0.723 | ||
| Gemma-2-27B | 0.218 | 0.718 | ||
| MedGemma-27B-Text | 0.225 | 0.725 | ||
| A.X-4.0-Light | 0.217 | 0.722 | ||
| HCX-SEED-Text-1.5B | 0.199 | 0.693 | ||
(a) Chinese
| Model | Text | Multimodal | ||
|---|---|---|---|---|
| ROUGE | BERTScore | ROUGE | BERTScore | |
| Closed large vision-language models | ||||
| GPT-4.1 mini | 0.229 | 0.730 | 0.194 | 0.710 |
| GPT-4.1 | 0.221 | 0.727 | 0.186 | 0.710 |
| Gemini 2.5 Flash | 0.218 | 0.724 | 0.186 | 0.701 |
| Gemini 2.5 Pro | 0.211 | 0.720 | 0.189 | 0.708 |
| Open-weight large vision-language models | ||||
| Qwen3-VL-8B | 0.200 | 0.726 | 0.170 | 0.708 |
| Qwen3-VL-32B | 0.210 | 0.725 | 0.184 | 0.707 |
| Gemma-3-12B | 0.206 | 0.719 | 0.187 | 0.707 |
| Gemma-3-27B | 0.206 | 0.720 | 0.190 | 0.707 |
| MedGemma-27B | 0.206 | 0.720 | 0.184 | 0.702 |
| A.X-4.0-VL-Light | 0.181 | 0.712 | 0.171 | 0.705 |
| HCX-SEED-Vision-3B | 0.167 | 0.691 | 0.138 | 0.666 |
| Open-weight large language models | ||||
| Qwen3-8B | 0.222 | 0.731 | ||
| Qwen3-32B | 0.211 | 0.725 | ||
| Gemma-2-9B | 0.216 | 0.721 | ||
| Gemma-2-27B | 0.210 | 0.717 | ||
| MedGemma-27B-Text | 0.213 | 0.723 | ||
| A.X-4.0-Light | 0.193 | 0.716 | ||
| HCX-SEED-Text-1.5B | 0.124 | 0.650 | ||
(c) Indonesian
| Model | Text | Multimodal | ||
|---|---|---|---|---|
| ROUGE | BERTScore | ROUGE | BERTScore | |
| Closed large vision-language models | ||||
| GPT-4.1 mini | 0.209 | 0.713 | 0.196 | 0.697 |
| GPT-4.1 | 0.200 | 0.708 | 0.187 | 0.693 |
| Gemini 2.5 Flash | 0.209 | 0.711 | 0.195 | 0.689 |
| Gemini 2.5 Pro | 0.198 | 0.704 | 0.196 | 0.694 |
| Open-weight large vision-language models | ||||
| Qwen3-VL-8B | 0.191 | 0.706 | 0.191 | 0.695 |
| Qwen3-VL-32B | 0.195 | 0.706 | 0.180 | 0.689 |
| Gemma-3-12B | 0.196 | 0.703 | 0.197 | 0.691 |
| Gemma-3-27B | 0.198 | 0.706 | 0.200 | 0.692 |
| MedGemma-27B | 0.197 | 0.705 | 0.194 | 0.691 |
| A.X-4.0-VL-Light | 0.190 | 0.695 | 0.188 | 0.690 |
| HCX-SEED-Vision-3B | 0.186 | 0.687 | 0.171 | 0.670 |
| Open-weight large language models | ||||
| Qwen3-8B | 0.213 | 0.715 | ||
| Qwen3-32B | 0.196 | 0.707 | ||
| Gemma-2-9B | 0.206 | 0.704 | ||
| Gemma-2-27B | 0.202 | 0.700 | ||
| MedGemma-27B-Text | 0.204 | 0.709 | ||
| A.X-4.0-Light | 0.203 | 0.706 | ||
| HCX-SEED-Text-1.5B | 0.174 | 0.651 | ||
(b) German
| Model | Text | Multimodal | ||
|---|---|---|---|---|
| ROUGE | BERTScore | ROUGE | BERTScore | |
| Closed large vision-language models | ||||
| GPT-4.1 mini | 0.175 | 0.728 | 0.155 | 0.715 |
| GPT-4.1 | 0.171 | 0.726 | 0.154 | 0.713 |
| Gemini 2.5 Flash | 0.168 | 0.725 | 0.155 | 0.707 |
| Gemini 2.5 Pro | 0.152 | 0.720 | 0.148 | 0.712 |
| Open-weight large vision-language models | ||||
| Qwen3-VL-8B | 0.150 | 0.717 | 0.132 | 0.707 |
| Qwen3-VL-32B | 0.158 | 0.722 | 0.135 | 0.708 |
| Gemma-3-12B | 0.160 | 0.722 | 0.159 | 0.714 |
| Gemma-3-27B | 0.162 | 0.723 | 0.161 | 0.714 |
| MedGemma-27B | 0.160 | 0.721 | 0.151 | 0.709 |
| A.X-4.0-VL-Light | 0.149 | 0.702 | 0.134 | 0.689 |
| HCX-SEED-Vision-3B | 0.141 | 0.661 | 0.100 | 0.545 |
| Open-weight large language models | ||||
| Qwen3-8B | 0.175 | 0.728 | ||
| Qwen3-32B | 0.170 | 0.725 | ||
| Gemma-2-9B | 0.170 | 0.722 | ||
| Gemma-2-27B | 0.166 | 0.718 | ||
| MedGemma-27B-Text | 0.159 | 0.722 | ||
| A.X-4.0-Light | 0.147 | 0.697 | ||
| HCX-SEED-Text-1.5B | 0.127 | 0.678 | ||
(d) Arabic
Table A9: Zero-shot performance on the Chinese, German, Indonesian, and Arabic versions of PETQA-BENCH. Bold and underlined indicate the best and second-best results, respectively.
| Model | Text | Multimodal | ||||||
|---|---|---|---|---|---|---|---|---|
| ROUGE | BERTScore | Factuality | Helpfulness | ROUGE | BERTScore | Factuality | Helpfulness | |
| Closed large vision-language models | ||||||||
| GPT-4.1 mini | 0.299 (+0.004) | 0.745 (-0.001) | 0.569 (+0.018) | 4.827 (+0.099) | 0.235 (-0.002) | 0.724 (-0.002) | 0.534 (+0.003) | 4.780 (+0.183) |
| GPT-4.1 | 0.287 (-0.003) | 0.741 (-0.002) | 0.571 (+0.002) | 4.931 (+0.051) | 0.228 (-0.006) | 0.722 (-0.004) | 0.531 (0.000) | 4.809 (+0.094) |
| Gemini 2.5 Flash | 0.276 (-0.003) | 0.729 (-0.002) | 0.536 (-0.005) | 4.777 (-0.137) | 0.221 (-0.003) | 0.702 (-0.007) | 0.497 (+0.002) | 4.727 (+0.048) |
| Gemini 2.5 Pro | 0.292 (+0.012) | 0.741 (+0.003) | 0.556 (+0.006) | 4.921 (-0.002) | 0.248 (+0.002) | 0.727 (+0.001) | 0.539 (+0.015) | 4.866 (+0.052) |
| Open-weight large vision-language models | ||||||||
| Qwen3-VL-8B | 0.279 (+0.008) | 0.739 (+0.002) | 0.508 (+0.009) | 3.986 (+0.025) | 0.227 (+0.023) | 0.722 (+0.001) | 0.479 (+0.018) | 3.460 (+0.384) |
| Qwen3-VL-32B | 0.252 (-0.006) | 0.726 (-0.004) | 0.522 (+0.009) | 4.825 (-0.042) | 0.209 (-0.006) | 0.704 (-0.008) | 0.485 (-0.004) | 4.721 (-0.073) |
| Gemma-3-12B | 0.277 (-0.010) | 0.732 (-0.008) | 0.503 (-0.007) | 4.434 (-0.127) | 0.232 (-0.011) | 0.717 (-0.006) | 0.457 (-0.033) | 4.032 (-0.223) |
| Gemma-3-27B | 0.276 (-0.004) | 0.734 (-0.003) | 0.523 (+0.004) | 4.815 (-0.055) | 0.237 (-0.007) | 0.721 (-0.003) | 0.506 (+0.010) | 4.641 (+0.015) |
| MedGemma-27B | 0.256 (-0.003) | 0.716 (+0.001) | 0.504 (+0.001) | 4.791 (-0.081) | 0.216 (-0.004) | 0.700 (-0.002) | 0.454 (+0.012) | 4.591 (-0.043) |
| A.X-4.0-VL-Light | 0.289 (+0.012) | 0.734 (+0.007) | 0.472 (-0.010) | 3.510 (-0.221) | 0.237 (-0.001) | 0.717 (-0.005) | 0.463 (+0.002) | 3.882 (+0.259) |
| HCX-SEED-Vision-3B | 0.281 (-0.003) | 0.732 (-0.003) | 0.495 (+0.002) | 3.896 (+0.120) | 0.230 (0.000) | 0.711 (-0.007) | 0.467 (+0.016) | 3.942 (+0.271) |
| Open-weight large language models | ||||||||
| Qwen3-8B | 0.294 (0.000) | 0.746 (0.000) | 0.508 (-0.006) | 3.801 (+0.047) | ||||
| Qwen3-32B | 0.281 (-0.001) | 0.741 (-0.001) | 0.534 (+0.004) | 4.524 (+0.091) | ||||
| Gemma-2-9B | 0.299 (+0.011) | 0.744 (+0.011) | 0.502 (-0.016) | 3.615 (-0.561) | ||||
| Gemma-2-27B | 0.291 (+0.016) | 0.730 (+0.014) | 0.510 (+0.021) | 4.296 (-0.258) | ||||
| MedGemma-27B-Text | 0.276 (-0.012) | 0.732 (-0.007) | 0.528 (-0.018) | 4.565 (-0.229) | ||||
| A.X-4.0-Light | 0.274 (-0.015) | 0.723 (-0.007) | 0.503 (+0.001) | 4.561 (+0.349) | ||||
| HCX-SEED-Text-1.5B | 0.281 (+0.014) | 0.733 (-0.010) | 0.487 (+0.004) | 3.707 (+0.228) | ||||
Table A10: Performance of RAG on PETQA-BENCH. Parenthetical values report , with blue text indicating positive values and red text indicating a negative value. Bold and underlined indicate the best and second-best results, respectively.
| Model | Text | Multimodal | ||||||
|---|---|---|---|---|---|---|---|---|
| ROUGE | BERTScore | Factuality | Helpfulness | ROUGE | BERTScore | Factuality | Helpfulness | |
| Open-weight large vision-language models | ||||||||
| Qwen3-VL-8B | 0.341 (+0.070) | 0.771 (+0.034) | 0.477 (-0.022) | 2.649 (-1.312) | 0.239 (+0.035) | 0.698 (-0.023) | 0.317 (-0.144) | 1.978 (-1.098) |
| Qwen3-VL-32B | 0.354 (+0.096) | 0.776 (+0.046) | 0.513 (0.000) | 2.880 (-1.987) | 0.266 (+0.051) | 0.724 (+0.012) | 0.379 (-0.110) | 2.343 (-2.451) |
| Gemma-3-12B | 0.360 (+0.073) | 0.775 (+0.035) | 0.498 (-0.012) | 2.788 (-1.773) | 0.299 (+0.056) | 0.745 (+0.022) | 0.409 (-0.081) | 2.463 (-1.792) |
| Gemma-3-27B | 0.366 (+0.086) | 0.777 (+0.040) | 0.507 (-0.012) | 2.897 (-1.973) | 0.321 (+0.077) | 0.757 (+0.033) | 0.433 (-0.063) | 2.499 (-2.127) |
| MedGemma-27B | 0.361 (+0.102) | 0.779 (+0.064) | 0.518 (+0.015) | 2.878 (-1.994) | 0.324 (+0.104) | 0.763 (+0.061) | 0.476 (+0.034) | 2.694 (-1.940) |
| A.X-4.0-VL-Light | 0.327 (+0.050) | 0.759 (+0.032) | 0.431 (-0.051) | 2.392 (-1.339) | 0.261 (+0.023) | 0.740 (+0.018) | 0.384 (-0.077) | 2.502 (-1.121) |
| HCX-SEED-Vision-3B | 0.341 (+0.057) | 0.771 (+0.036) | 0.469 (-0.024) | 2.571 (-1.205) | 0.280 (+0.050) | 0.747 (+0.029) | 0.399 (-0.052) | 2.402 (-1.269) |
| Open-weight large language models | ||||||||
| Qwen3-8B | 0.337 (+0.043) | 0.769 (+0.023) | 0.471 (-0.043) | 2.629 (-1.125) | ||||
| Qwen3-32B | 0.348 (+0.066) | 0.775 (+0.033) | 0.506 (-0.024) | 2.849 (-1.584) | ||||
| Gemma-2-9B | 0.348 (+0.060) | 0.776 (+0.043) | 0.506 (-0.012) | 2.736 (-1.440) | ||||
| Gemma-2-27B | 0.350 (+0.075) | 0.776 (+0.060) | 0.517 (+0.028) | 2.787 (-1.767) | ||||
| MedGemma-27B-Text | 0.362 (+0.074) | 0.780 (+0.041) | 0.524 (-0.022) | 2.943 (-1.851) | ||||
| A.X-4.0-Light | 0.346 (+0.057) | 0.773 (+0.043) | 0.486 (-0.016) | 2.794 (-1.418) | ||||
| HCX-SEED-Text-1.5B | 0.336 (+0.041) | 0.769 (+0.026) | 0.451 (-0.032) | 2.466 (-1.013) | ||||
Table A11: SFT performance measured on PETQA-BENCH. Parenthetical values report , with blue text indicating positive values and red text indicating negative values. Bold and underlined indicate the best and second-best results, respectively.
| Question | My dog seemed to be in heat, so I put a diaper on her, and this came out on it. What is this? | |
|---|---|---|
| Reference Answer | ||
| It is highly likely to be pyometra. Common symptoms of pyometra include polydipsia, polyuria, vomiting, loss of appetite, abdominal distension, and pus discharge from the genital area. An accurate diagnosis should be confirmed at a veterinary clinic using ultrasonography. | ||
| Retrieved Documents | ||
| Pyometra, haemometra, mucometra - Tumour ......Discharge (vulvitis/vaginitis, pyometra, haemometra, mucometra) ......Principal SymptomsPolydipsia, Polyuria, Vaginal discharge, Behavioral changes, ... | ||
| Gemma-3-12B | ||
| Zero-shot Output | ||
| What is shown in the picture appears to be menstrual blood from the dog. A dog's discharge during the heat cycle usually changes from red to brown and may appear in clumps. The estrous cycle in dogs typically lasts between 21 and 35 days, and bleeding may continue for 2 to 10 days. However, if the amount of bleeding is excessive or accompanied by other symptoms, consulting a veterinarian is recommended. | ||
| RAG Output | ||
| The substance found on the dog's diaper appears to be blood. According to Documents 2 and 6, vaginal discharge may indicate uterine conditions such as pyometra, haemometra, or mucometra, or conditions such as vulvitis/vaginitis. In addition, behavioral changes, polyuria, and polydipsia may also occur (Document 5). It is important to have the dog examined by a veterinarian to determine the exact cause and receive appropriate treatment. | ||
| Analysis | ||
| Unlike the zero-shot response, which misinterpreted the discharge as a normal menstrual cycle, the RAG response correctly identified the possibility of uterine conditions, such as pyometra, from the retrieved documents, demonstrating cross-modal reasoning by grounding the clinical image and the retrieved documents to produce an accurate answer. | ||
Figure A2: Qualitative example in which retrieval-augmented generation (RAG) produces an accurate response by jointly reasoning over the clinical image and retrieved documents.
| Question | |
|---|---|
| I am wondering what this pimple-like bump on the back of my 3-year-old Chihuahua’s neck could be. Is it okay to leave it untreated? |  |
| Reference Answer | |
| Based on the image, it is highly likely to be a skin tumor, such as a papilloma, and biopsy as well as surgical treatment may be necessary. If left untreated, it may increase in size and worsen with inflammation and bleeding. | |
| Retrieved Documents | |
| Retention cyst of the salivary gland (ranula)Structures of the throat/neck - Retention cyst of the salivary gland (cyst on the neck/meliceris) ... | |
| Gemma-3-12B | |
| Zero-shot Output | |
| The bump shown in the image may be a skin tumor. If left untreated, it could grow larger or become inflamed, so it is recommended that a veterinarian examine it. Visit a veterinary clinic for an accurate diagnosis and appropriate treatment. | |
| RAG Output | |
| The pimple-like lesion on the back of the 3-year-old Chihuahua’s neck may be a retention cyst of the salivary gland. This is also referred to as meliceris. Whether it is safe to leave untreated depends on an accurate diagnosis, so it is recommended to consult a veterinarian for an examination. | |
| Analysis | |
| In the zero-shot response, the model directly interprets the lesion’s appearance and correctly identifies it as a skin tumor. In contrast, RAG biases the model toward the retrieved text, which mentions a salivary gland retention cyst, causing it to prioritize lexical overlap with the question over visual evidence. As a result, the alignment between visual and textual cues breaks down, leading to an incorrect diagnosis. | |
Figure A3: Qualitative example showing that retrieval-augmented generation (RAG) prioritizes retrieved text over visual context, leading to an incorrect diagnosis.
| Question | |
|---|---|
| A dog had a mild seizure in February and underwent X-rays and blood tests. No disk herniation was found, patellar luxation was present, and the liver enzymes were slightly elevated. The dog had another seizure today, so we are considering an MRI. The seizure lasts about 1-2 minutes, and the dog has no problems walking or running. Does everything look normal in the photos? |  |
| Reference Answer | |
| Based on the submitted materials, the current condition appears to be completely normal. However, since the tests were performed 4-5 months ago, a follow-up examination may be necessary. Even if the previous test results were normal, it does not mean that the current condition is entirely flawless. A repeat examination is recommended, and even if acupuncture treatment is pursued, an MRI should still be performed. It is important to identify the lesion and proceed with treatment accordingly; treatment without objective evidence would be reckless. After the MRI, it would be advisable to choose rehabilitation therapy or acupuncture. I hope the problem can be resolved through prompt and accurate diagnosis and effective treatment. | |
| Qwen3-VL-32B | |
| Zero-shot Output | |
| On the X-ray image, no spinal disk herniation or clear skeletal abnormalities are observed. Patellar luxation can be detected on X-rays, but no definite signs of luxation are visible in this image, and further evaluation, such as MRI, may be necessary. The elevated liver enzymes and seizure symptoms raise suspicion of a neurological cause, and an MRI can more accurately assess abnormalities in the spinal cord or brain. Based on the X-ray alone, the cause of the seizures cannot be determined, and an MRI is recommended. There is no immediate skeletal abnormality visible in the photo, but additional testing is needed for neurological evaluation. | |
| SFT Output | |
| The current radiograph has limited value for diagnosing a disk problem. For accurate diagnosis, the dog must be properly restrained during radiography to prevent movement. If radiography is difficult, MRI should be considered. | |
| Analysis | |
| The SFT output is more general and conservative than the zero-shot response. Rather than providing a concrete visual assessment of the radiograph and discussing possible abnormalities, it offers only a cautious, generic response. Although this framing may reduce the risk of overinterpretation, it does not adequately address the user's request for an image-based assessment. | |
Figure A4: Qualitative example showing that supervised fine-tuning (SFT) produces a more generic and conservative response with reduced image-grounded reasoning.
Prompt: Preprocessing (Filtering)
Your role is to filter out irrelevant data to construct a veterinary medical question answering dataset for pets (dogs and cats). Please refer to the filtering criteria below and return strictly "true" or "false". Do not include any other text in your response.
Filtering Criteria
Return "false" if any of the following conditions apply:
-
Questions unrelated to veterinary medical consultations for pets (dogs and cats).
-
Questions regarding admission to veterinary schools, the veterinary profession, or licensing.
-
Questions containing personally identifiable information (PII) or content that violates service operation policies.
-
Answers based on groundless speculation.
-
Answers with little to no informational value, such as simply stating "Please visit a veterinary clinic."
If none of the above conditions apply, return "true".
Question: {question}
Answer: {answer}
Prompt: Preprocessing (Cleaning)
Your role is to remove unnecessary phrases and refine expressions to construct a high-quality veterinary medical question answering dataset for pets (dogs and cats). Please refer to the cleaning guidelines below to preprocess the given data into a "preprocessed question" and "preprocessed answer". You must output the result strictly in the JSON format specified below.
Cleaning Guidelines
Maintain the core meaning of the original question and answer while removing the following elements. Ensure that critical details such as pet demographics (species, age, weight) and clinical symptoms are not omitted from the question. Similarly, ensure that essential information, such as diagnostic procedures and treatment methods, is preserved in the answer.
-
Remove Personally Identifiable Information (PII): Delete names, phone numbers, email addresses, physical addresses, etc.
-
Correct Spelling and Grammar: Rectify errors considering the context.
-
Convert Colloquialisms: Transform conversational language into a formal, written style appropriate for official Q&A formats.
-
Remove Promotional Content: Delete advertisements or promotional phrases.
-
Remove Unnecessary Emotional Expressions: Delete phrases that do not contribute to the factual meaning.
-
Remove Other Superfluous Phrases: Delete unnecessary conversational fillers and greetings.
Output Format
{ "preprocessed_question": "string", "preprocessed_answer": "string" }
Question: {question}
Answer: {answer}
Figure A5: LLM-based preprocessing prompt.
Prompt: LLM-as-a-Judge (Factuality)
You will be given a question, a reference answer, and a predicted answer. Please verify the factual correctness of the predicted answer by comparing it with the reference answer, following these steps:
-
Break down the predicted answer into independent factual statements. Each fact should be a separate sentence.
-
Evaluate each fact individually: determine whether the reference answer supports the fact. Do not use external knowledge or additional background knowledge.
-
Next, break down the reference answer into independent factual statements. Each fact should be a separate sentence.
-
Evaluate each fact individually: determine whether the predicted answer supports the fact. Do not use external knowledge or additional background knowledge.
-
Finally, summarize (1.) how many predicted facts the reference answer supports and (2.) how many reference facts are supported by the predicted answer.
Generate the output in JSON format as shown in the examples below.
{Example 1}
{Example 2}
Input
Question: {question}
Reference Answer: {gold_answer}
Predicted Answer: {pred_answer}
Output:
Figure A6: LLM-as-a-judge prompt used for factuality evaluation.
Prompt: LLM-as-a-Judge (Helpfulness)
You are an expert at evaluating the quality of text.
As an impartial evaluator, please assess how useful the AI assistant's response is to the user's question.
Specifically, evaluate the following criteria: 1) relevance to the question; 2) whether it meets the user's purpose and needs; 3) whether it provides a sufficient and appropriate answer.
You must first provide an analysis, and then strictly assign a score between 1 and 5 in the following format: "[[Rating]]", e.g., "[[5]]".
Examples
{Example 1}
{Example 2}
{Example 3}
Now, please evaluate the following AI assistant's response based on the evaluation criteria and examples above:
Question
{question}
Assistant's Answer Begins
{pred_answer}
Assistant's Answer Ends
Analysis
Figure A7: LLM-as-a-judge prompt used for helpfulness evaluation.
Prompt: Question Answering (Zero-Shot)
Your role is to answer the given question. Do not generate more than five sentences in your response.
Question: {question}
Answer:
Figure A8: Zero-shot prompt for question answering. The same prompt is used under supervised fine-tuning.
Prompt: Question Answering (RAG)
Your role is to answer the given question. Do not generate more than five sentences in your response.
Retrieved documents are provided below. If the retrieved documents are relevant to the question, refer to them when answering; otherwise, ignore them and answer based on your own knowledge.
Question: {question}
Retrieved Documents: {paragraphs}
Answer:
Figure A9: Prompt used for retrieval-augmented generation (RAG).

(a) For question types and clinical conditions.
(b) For expert verification of dataset quality.
Figure A10: Interfaces used for dataset annotation and expert validation.