arXiv:2609.04747physics.med-phSep 2026

Manuscript Offprint

arXiv:2609.04747

BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction

Chen Cheng, Michael Ferraro, James Grover, David E J Waddington, Emily Hewson

Chen Cheng1^{1}[0009-0007-6612-315X], Michael Ferraro1^{1}[0009-0002-9211-0321], James Grover1^{1}[0009-0009-6743-7809], David E J Waddington1^{1}[0000-0002-7017-1556], and Emily Hewson1^{1}[0000-0001-7353-2663]

Image X Institute, The University of Sydney, Sydney, Australia chen.cheng@sydney.edu.au

Abstract. To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation via sub-pixel phase packing, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated by a patch-based conditional GAN with a SwinUNETR backbone. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.

Keywords: deep learning · proton dose calculation · photon dose calculation · synthetic CT · Mamba-3.

1 Introduction

Monte Carlo (MC) simulation is the gold standard for radiotherapy dose calculation [16], but its computational cost limits its use in time-sensitive applications

C. Cheng et al.

such as online adaptive radiotherapy [10] and dose-guided radiotherapy [4]. The DoseRAD2026 Grand Challenge benchmarks rapid photon and proton beam-level dose calculation from CT and MRI. Beam-level modelling enables learning of beam-to-anatomy dose relationships, supporting flexible plan optimisation and dose accumulation workflows [6].

Beam's-eye-view (BEV) slice-sequence models represent dose transport along a common beam-depth axis, reducing the need to encode treatment geometry explicitly while supporting efficient beam-level prediction [13, 14, 22]. Following this approach, we formulate 3D dose calculation using a 2D CNN encoder, a depth-sequence core, and a 2D CNN decoder.

We build on the BEV CNN-sequence architecture of Xiao et al. [22] and introduce targeted modifications to improve beam coverage, BEV-to-CT resampling accuracy, model capacity, and downstream depth context. Photon and proton models share this framework but use task-specific sequence cores and inputs, including proton transport conditioning. For the MRI tasks, a SwinUNETR-based [2] conditional generative adversarial network first generates a synthetic CT (sCT), which is passed to the corresponding CT-to-dose model. We apply these methods to all four challenge tasks: CT- and MRI-based photon dose calculation and CT- and MRI-based proton dose calculation.

References (22)