³ Norwegian University of Science and Technology, Norway kiran.raja@ntnu.no

Abstract. Automated gastrointestinal (GI) endoscopy classification requires models that generalize across diverse modalities and class distributions, often far from natural-image pretraining. We propose MultiAttenGastro, a plug-and-play attention framework with parallel 1-D channel, 2-D spatial, and 3-D contextual heads, and present the first systematic cross-dataset evaluation across eight CNN and transformer backbones on five public GI datasets (80 backbone-dataset runs). We find that attention effectiveness is not universal but tracks the representational gap between ImageNet features and the target distribution: MultiAttenGastro improves 6 of 8 backbones on Kvasir-Capsule (14-class WCE, large gap; best macro F1 98.33%), is uniformly negative on the small-gap Kvasir-v2 benchmark (0/8), and shows mixed outcomes on datasets with intermediate gap. Five-seed ablation on the strongest case (Kvasir-Capsule, ConvNeXt-Tiny) shows this improvement is directionally consistent but not statistically decisive (paired tt: p=0.47p = 0.47; Wilcoxon: p=0.63p = 0.63), and that individual attention heads are not uniformly beneficial in isolation — only their combination yields a positive mean effect. Centered Kernel Alignment (CKA) analysis links this pattern to representational redundancy: low inter-head CKA under large domain gaps coincides with the framework's only consistent gains, while high redundancy under small gaps coincides with its losses. We report these results, including the non-significant margins, as evidence for when and why multi-dimensional attention helps GI endoscopy classification, rather than as a claim that MultiAttenGastro is a strictly superior architectural choice.

Keywords: Wireless Capsule Endoscopy · Gastrointestinal Classification · Attention Mechanism · Explainable AI

1 Introduction

Wireless capsule endoscopy (WCE) produces up to 50,000 frames over 8–10 hours as a pill-sized camera traverses the GI tract [1,2]. Pathologies such as bleeding,

Devarajan et. al.

polyps, or erosions may appear in fewer than 0.1% of frames, making automated classification a clinical necessity. The Kvasir-Capsule benchmark [3] exemplifies this challenge with 47,238 labelled WCE images across 14 categories and an extreme 3,434:1 imbalance between normal and rare pathology. Gastroscopy datasets such as Kvasir-v2, HyperKvasir, and GastroVision extend the task to 8–27 classes in a modality visually closer to natural images.

We propose MultiAttenGastro, a plug-and-play framework that applies parallel 1D + 2D + 3D attention mechanisms to GI endoscopy classification, capturing channel, spatial, and contextual dependencies for fine-grained lesion discrimination. Unlike prior single-dataset studies, we conduct the first systematic cross-dataset evaluation of multi-dimensional attention across diverse GI imaging conditions. Our findings show that attention effectiveness is not universal but correlates with a measurable factor: initial results suggested a modality-dependent effect (helping WCE, hurting gastroscopy), but adding SEE-AI revealed mixed outcomes that modality alone could not explain. The strongest associated factor is the representation gap between ImageNet-pretrained features and the target dataset — large for Kvasir-Capsule's rare pathologies, small for gastroscopy's natural-image-like appearance, and small for SEE-AI's simpler four-class taxonomy despite its WCE modality. We treat this as an empirical association supported by five-seed ablation, CKA analysis, and Grad-CAM (Sects. 5.3–7), not as a proven causal mechanism; Sect. 7.2 shows the association is not perfect even within our own data.

This paper makes the following contributions:

(i) We propose MultiAttenGastro and evaluate it across eight CNN and transformer backbones and five datasets (80 runs), constituting the first cross-dataset study of multi-dimensional attention in GI imaging.

(ii) We show that MultiAttenGastro's effectiveness correlates with the representational domain gap between ImageNet pretraining and the target dataset, rather than imaging modality: it helps under large gap (Kvasir-Capsule), hurts uniformly under small gap (Kvasir-v2), and is mixed at intermediate gap, with SEE-AI (WCE, small gap) confirming that modality alone does not determine outcome.

(iii) Through five-seed ablation, paired significance testing, and CKA analysis, we show that (a) the module's benefit on its strongest case is directionally consistent but not statistically significant at n=5n = 5 seeds, (b) individual attention heads are not independently beneficial — only their combination is — and (c) this pattern correlates with inter-head representational redundancy, which is itself gap-dependent.

(iv) We qualitatively corroborate this framework with Grad-CAM, showing lesion-focused activation gains on the high-gap dataset and dispersed, non-diagnostic activation shifts on the low-gap dataset.

References (29)

  • Vision-based personalized wireless capsule endoscopy for smart healthcare
  • Wireless capsule endoscopy
  • Kvasir-Capsule, a video capsule endoscopy dataset
  • Abnormality classification in small datasets of capsule endoscopy images
  • Enhanced accuracy for classification of video capsule endoscopy images using multiple deep learning convolutional neural networks
  • Efficient-gastro: optimized EfficientNet for gastrointestinal disorders via transfer learning
  • Precision enhancement in wireless capsule endoscopy: a novel transformer-based approach for real-time video object detection
  • Squeeze-and-excitation networks
  • CBAM: Convolutional block attention module
  • Multidimensional weighted attention-guided network for diabetic retinopathy grading
  • Systematic integration of attention modules into CNNs for medical image classification
  • Attention U-Net: Learning Where to Look for the Pancreas
  • Attention gated networks: Learning to leverage salient regions in medical images
  • AW-Net: A novel fully connected attention-based medical image segmentation model
  • PanNet: A feature-based attention aggregation model for segmenting pancreatic ductal adenocarcinoma on contrast-enhanced CT images of the abdomen
  • Coordinate attention for efficient mobile network design
  • Rotate to attend: Convolutional triplet attention module
  • ECA-Net: Efficient channel attention for deep convolutional neural networks
  • Score-CAM: Score-weighted visual explanations for convolutional neural networks
  • Why should I trust you?
  • A unified approach to interpreting model predictions
  • Grad-CAM: Visual explanations from deep networks via gradient-based localization
  • EndoNet: A multiscale deep learning framework for multiple gastrointestinal disease classification via endoscopic images
  • Explainable AI in digestive healthcare and gastrointestinal endoscopy
  • Towards full integration of explainable AI in colon capsule endoscopy
  • EfficientNet: Rethinking model scaling for convolutional neural networks
  • Densely connected convolutional networks
  • Similarity of neural network representations revisited
  • Capsule Endoscopy Multi-classification via Gated Attention and Wavelet Transformations (opens arXiv in a new tab)