Manuscript Offprint

arXiv:2609.05140

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

Nazim-E-Alam

Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operating-point transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries.

Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3,257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1,077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR.

Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and

*Corresponding author. Email address: nazimriyadh001@gmail.com (Nazim-E-Alam)

VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability.

Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

Keywords: Pediatric chest X-ray, Pneumonia, Deep learning, Domain shift, Calibration, External testing, Model transportability

1. Introduction

Deep learning has produced strong within-dataset results for chest-radiograph classification, including pediatric pneumonia, but high benchmark performance does not establish transportability to different populations or acquisition environments [1, 2, 3]. Pediatric radiography is particularly sensitive to distributional change because age-dependent anatomy, positioning, body habitus, disease spectrum, equipment, and interpretation practice can differ across sites. Reviews of pediatric radiology AI continue to identify restricted external testing and uncertain clinical generalizability as major limitations, while recent pediatric pneumonia reviews show continued concentration on the

Guangzhou/Kermany benchmark [4, 5, 6, 7, 8]. Work in CMPB has likewise emphasized that pediatric pneumonia AI should be assessed beyond a single accuracy estimate and with attention to applicability and reference-standard limitations [9].

External degradation is well documented in radiology. Multi-hospital studies have shown that chest-radiograph models can encode site identity and exhibit large performance changes outside the development environment [10], and systematic reviews report external decreases for most evaluated radiologic deep-learning systems [11]. Pediatric evidence is more limited but points in the same direction [12]. Such failure cannot be attributed to geography alone: public datasets may differ simultaneously in case mix, age range, acquisition hardware, preprocessing, compression, prevalence, disease definitions, and reference standards.

A second problem is that external performance is often summarized by AUROC. Discrimination, probability calibration, and operating-point behavior answer different questions. AUROC measures ranking across thresholds, calibration measures agreement between probability and observed frequency, and sensitivity/specificity depend on a chosen threshold and the target score distribution [13, 14]. A monotonic target shift can therefore leave AUROC useful while making a source-derived operating point nearly nonfunctional. Conversely, recalibration can improve probabilities and operating characteristics without improving ranking [15, 16]. This distinction is important for deployment because an apparently successful recalibration may still generate an unacceptable alert burden.

Imaging models can also exploit unstable acquisition-associated signals.

Hospital markers, peripheral regions, text, borders, and other non-anatomic correlates have been implicated as shortcuts in chest-radiograph AI [17, 18, 19]. Such stress tests cannot prove causal feature use, but they can establish whether target data contain label-correlated signals outside the intended anatomy.

We therefore evaluated a locked computational transportability protocol that separates five components: discrimination, probability calibration, fixed operating-point behavior, shortcut/acquisition-associated signal, and limited-label recoverability. A Guangzhou model was frozen before complete-cohort testing in Bangladesh and untouched testing in Vietnam. Bangladesh was used for adaptation only after its primary zero-shot result was retained. Architecture-robustness experiments tested whether the transport phenomenon depended on the proposed dual-view implementation. We hypothesized that ranking, probability alignment, and source-defined operating behavior would transport differently, and that limited target labels would repair score alignment before producing large improvements in ranking.

References (24)