arXiv:2609.05323cs.CVSep 2026

Manuscript Offprint

arXiv:2609.05323

Scalable Detection of Fossil Palynomorphs in Multifocal Digital Microscopy Images

Abbas Shaikh, Praise Mayor, Patrick Ainlay-Vazquez, Aditya Viswanathan, Teon Golden, Eric Zhang, Ingrid C. Romero, Alexander E. White, Scott Wing, Arko Barman

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original. This text is shared under the same licence.

Abbas Shaikh

Rice University

Houston TX USA

abbas@alumni.rice.edu

Praise Mayor

Rice University

Houston TX USA

pom1@rice.edu

Teon Golden

Rice University

Houston TX USA

tjg7@rice.edu

Patrick Ainlay-Vazquez

Rice University

Houston TX USA

pta2@rice.edu

Aditya Viswanathan

Rice University

Houston TX USA

av77@rice.edu

Eric Zhang

Rice University

Houston TX USA

erictz@alumni.rice.edu

Ingrid C. Romero

Smithsonian National Museum of Natural History

Washington DC USA

RomeroIC@si.edu

Alexander E. White

Smithsonian Office of Digital and Innovation

Washington DC USA

WhiteAE@si.edu

Scott Wing

Smithsonian National Museum of Natural History

Washington DC USA

wings@si.edu

Arko Barman

Rice University

Houston TX USA

arko.barman@rice.edu

Abstract

Palynomorphs (microscopic, organic-walled fossils such as pollen, spores, and dinoflagellates) are important high-resolution records of past climates and are critical to the study of ancient ecosystems. Existing methods rely on manual analysis of high-resolution, multifocal digital microscopy images, which is slow and time-consuming and requires researchers to compromise on the scale of their investigations. To the best of our knowledge, our work proposes the first ever scalable end-to-end pipeline for automated palynomorph detection in whole slide images that addresses this bottleneck through: (1) efficient methods for decomposing and compressing digitized multifocal microscope slide images into tractable 2-dimensional tiles for analysis; (2) benchmarking modern object detection models, including RF-DETR, for the detection of palynomorphs, achieving an AP@50 of 0.879; (3) an efficient algorithm for the synthesis of detection outputs across large-scale, high-resolution images; and (4) an I/O optimization resulting in faster inference time. Our methods drastically reduce the time required for palynomorph detection in a single slide from often days of manual inspection to under one hour of

automated analysis, enabling palynological research at a substantially greater scale.

1. Introduction

Palynomorphs – microscopic, organic-walled fossil particles including pollen, spores, dinoflagellates, fungi, and algae – are among the most abundant and best-preserved plant fossils in the geological record [23, 24]. The study of palynomorphs is of critical importance in paleoclimatological research, acting as direct and resilient records of past environments that inform reconstructions of Earth’s past climates and projections of future ones [7, 24]. In particular, palynomorphs from ancient warm intervals, when CO2CO_{2} was elevated, offer empirical analogues for projecting ecosystem response under continued warming [4].

The Smithsonian National Museum of Natural History stewards a collection of tens of thousands of microscope slides of palynomorphs, in which a single slide can contain thousands of specimens [21]. While many slides have been digitized, only a small fraction have been actively studied. Manual analysis is often slow and time-consuming, as palynomorphs are interspersed with other sediments,

Figure

(a) High-level crop of a slide image with annotations.

(b) Crop at 10×10\times magnification with palynomorphs circled.

Figure 1. Sample slide image crops with human annotations at different scales.

making them difficult to distinguish and localize quickly. However, digitizing these slide collections opens the possibility of using machine-learning object detection models to support scalable, high-throughput palynological research [9, 15, 16, 18, 21].

Digitized slides are scanned at several magnifications and focal planes, producing several high-resolution images often exceeding 25 GB in total [21]. Given the sheer volume of data in a single digitized slide, processing an image in its entirety is computationally infeasible. This challenge prohibits the use of standard techniques for pre-processing, modeling, and post-processing used in standard object detection frameworks. These challenges are further compounded by the fact that multifocal images capture significantly more information and complexity than a standard two-dimensional image.

Each palynomorph specimen is a three-dimensional body suspended in mounting medium, and no single focal plane in a slide brings every specimen into focus. Specimens are also frequently dense, overlapping, or occluded by debris of similar contrast and texture. Furthermore, variations in staining, mounting medium, and acquisition parameters induce substantial appearance shifts across slides. Hence, a model fit to one preparation cannot necessarily be assumed to transfer to another. Figure 1 shows a representative annotated crop illustrating the density, variation in scale, and background clutter that characterize the data.

Due to these challenges, automated palynology has largely focused on classification of pre-cropped specimens, whether from single images [11, 18] or by treating image stacks as 3D sequential data [5, 20]. Detection has been addressed more recently [3, 6, 8, 12, 14, 22], but on fields of view of a few megapixels only [8], not on whole slide images.

The challenges of decomposing high-resolution, multifocal data from whole slide images remain unaddressed; hence, the throughput problem that motivates automation remains unsolved. Multifocal information is also seldom used for detection, the most common approach being to apply an object detection method once per plane and fuse the

resulting proposals across planes with non-maximum suppression (NMS) [8]. This strategy is impractical for most palynological research: for multifocal images consisting of 25–27 focal planes and up to 10,000 tiles per slide, detection and aggregation become exponentially costly. To the best of our knowledge, no prior work performs palynomorph detection at a whole-slide scale, and none reports an end-to-end system capable of performing detection on a complete, multifocal digitized slide.

Moreover, our end-to-end pipeline performs inference on entire slides at a pace comparable with the digitization of slides. While our baseline methods yield a runtime of roughly 8–9 hours per slide, our I/O optimization strategy reduces inference time to less than 1 hour per slide. Additionally, to the best of our knowledge, our work is the first to detect all organic remains that can fall into the palynomorph category, not focusing solely on pollen and spores, as seen in all prior research [3, 6, 8, 12, 14, 22].

Our contributions can be summarized as follows:

• We propose an end-to-end whole-slide palynomorph detection pipeline leveraging state-of-the-art object detection models, including You Only Look Once 26 (YOLO26) [10] and Roboflow DEtection TRansformer (RF-DETR) [19], usable at operational scale with inference times comparable to the digitization of microscope slide images.

• We develop a scalable preprocessing pipeline for high-resolution, multifocal microscopy data that crops images into tiles that are tractable for processing and compresses each focal stack into a single 2D image, yielding inputs directly usable by object detection models.

• We introduce a boundary-aware variant of the non-maximum suppression procedure to merge and deduplicate detections across thousands of tiles efficiently.

• We devise an I/O optimization method to speed up inference about 10 times, resulting in an inference time of less than 1 hour per slide.

References (23)