Manuscript Offprint
arXiv:2609.05347TherMosaic: Accelerating Perceived Thermal Transitions Through Spatiotemporal Thermal Feedback
Zining Zhang
University of Maryland
College Park, Maryland, USA
Zeyu Yan
University of Maryland
College Park, Maryland, USA
Jiasheng Li
University of Maryland
College Park, Maryland, USA
Jin Ryong Kim
University of Texas at Dallas
Richardson, Texas, USA
Myungin Lee
University of Maryland
College Park, Maryland, USA
Huaishu Peng
University of Maryland
College Park, Maryland, USA

Figure 1: (a) THERMOSAIC standalone wearable implementation. (b) Fingertip thermal display. (c) Examples of reported user thermal perception alongside corresponding per-Peltier measured temperatures. (d) Color-coded temperature scale showing perceptual categories and their boundaries. (e) Comparison of per-Peltier measured temperature changes over time and user thermal sensation between the baseline condition (Peltier producing uniform temperature) and THERMOSAIC. Our approach preconditions partial thermal inputs to maintain the current percept while reducing the apparent perceptual distance between categories, accelerating perception of transitions (e.g., switching between fire and ice magic in VR).
Abstract
Thermal feedback can enrich immersive interaction, but thermoelectric devices often change temperature too slowly to match interactive timing. We present THERMOSAIC, a spatiotemporal thermal feedback approach that accelerates perceived temperature transitions by leveraging two perceptual mechanisms: spatial summation and thermal adaptation. Focusing on the fingertip, we first investigate this approach using a custom 2x2 array of independently controlled Peltier modules. Across three controlled perceptual studies, we show that distributed thermal stimulation can preserve
stable hot and cold percepts despite local deviations, that adaptation helps maintain these percepts during changing stimulation, and that combining these effects reduces perceived transition time by about 30%–40% for transitions originating from hot or cold states. We then translate the same design principles into a standalone wearable implementation of THERMOSAIC and evaluate it in virtual reality. Our results show that this approach reduces perceived thermal lag and improves temporal alignment between thermal and visual events in interactive use.
CCS Concepts
• Human-centered computing → Haptic devices.

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
UIST '26, Detroit, MI, USA
© 2026 Copyright held by the owner/author(s).
ACM ISBN 979-8-4007-2856-3/2026/11
https://doi.org/10.1145/3830398.3830489
Zhang et al.
ACM Reference Format:
Zining Zhang, Jiasheng Li, Myungin Lee, Zeyu Yan, Jin Ryong Kim, and Huaishu Peng. 2026. THERMOSAIC: Accelerating Perceived Thermal Transitions Through Spatiotemporal Thermal Feedback. In The 39th Annual ACM Symposium on User Interface Software and Technology (UIST '26), November 02–05, 2026, Detroit, MI, USA. ACM, New York, NY, USA, 14 pages. https://doi.org/10.1145/3830398.3830489
1 Introduction
Thermal feedback has long been envisioned as a powerful channel for enhancing immersion, realism, and emotional expression in interactive systems and virtual reality. It communicates material qualities [33, 74], evokes affective cues [2, 3, 5, 40, 52, 71], and enriches multisensory experiences [14, 31, 39, 52]. Yet despite this promise, thermal feedback remains difficult to integrate into interactive settings because temperature transitions are often too slow to match the timing of user actions and virtual events. Most existing systems rely on thermoelectric actuators such as Peltier modules, whose heating and cooling dynamics are inherently gradual and often require several seconds or longer to switch between thermal states [12]. This lag can cause thermal sensations to fall out of synchrony with interaction events, weakening perceptual continuity and diminishing realism.
Prior approaches have largely treated this limitation as a hardware problem. Researchers have therefore sought to accelerate heat transfer through hardware innovations such as ultra-thin substrates [13], high-conductivity materials [29], and liquid-cooling mechanisms [72]. While effective, these approaches often increase system complexity, size, or power demands, which can limit their suitability for compact interfaces such as fingertip displays.
In this paper, we take a different perspective. Rather than seeking to increase the physical temperature ramp rate through hardware improvements, we ask whether thermal transitions can instead be made to feel faster. We propose THERMOSAIC, a spatiotemporal thermal feedback approach that accelerates perceived temperature transitions on the fingertip by coordinating multiple thermal subregions. We focus on the fingertip because it is both thermally sensitive and central to touch-based interaction, yet its limited area makes complex thermal hardware difficult to integrate.
THERMOSAIC works by dividing the fingertip contact area into multiple independently controlled thermal subregions and coordinating them over time. By shifting part of the skin toward an upcoming target temperature while preserving the current overall percept, the remaining physical change required for a perceptual category transition can be reduced. We draw on two established properties of thermal perception: spatial summation, which integrates distributed thermal inputs into a unified percept [10, 28], and thermal adaptation, which reduces sensitivity to ongoing or gradual local changes [37]. Together, these effects allow localized regions to be pre-warmed or pre-cooled without immediately disrupting the dominant sensation, enabling earlier perception of the final transition compared to a uniform actuator.
Our approach is conceptually related to prior work by Sato et al. [57, 58], which provided an early indication that spatially heterogeneous stimulation can shape the temporal experience of temperature under relatively small skin-temperature changes (2–4 °C).
THERMOSAIC extends this by systematically combining spatial summation and thermal adaptation to calibrated transitions across the full 20–40 °C operating range, reframing the problem as scheduled transitions among participant-specific cold, neutral, and hot perceptual categories.
To validate the perceptual basis of THERMOSAIC, we first developed a controlled benchtop 2×2 fingertip thermal experimental setup with independently controlled miniaturized Peltier elements. Using this setup, we conducted three controlled perceptual studies to test whether: (1) spatially distributed thermal deviations are integrated into a single categorical percept, (2) thermal adaptation stabilizes that percept when part of the stimulus drifts toward neutrality, and (3) combining these effects reduces perceived transition time between thermal states. Across these studies, we found that spatially distributed stimulation can be integrated and adaptively maintained to reduce perceived transition time between thermal states. We then translated the same design principles into a standalone wearable implementation of THERMOSAIC and evaluated it in a VR scenario against a baseline thermal interface, showing that it significantly reduces perceived thermal lag and improves temporal alignment in interactive use.
In summary, our contributions are: (1) We introduce THERMOSAIC, a spatiotemporal thermal feedback approach for accelerating perceived temperature transitions on the fingertip. (2) Through three perceptual studies, we empirically show how spatial summation and thermal adaptation can be leveraged to reduce perceived transition time. (3) We implement THERMOSAIC as a standalone wearable device and demonstrate in a VR study that it improves temporal alignment relative to a baseline thermal interface.
2 Related Work
2.1 Thermal Interfaces in HCI
Thermal feedback has been widely explored in HCI as a way to simulate material properties [33, 74], enhance immersion in virtual environments [43, 61, 67, 68], and convey affective or communicative cues [2, 3, 5, 40, 52, 71].
The most widely used actuator in thermal interfaces is the Peltier module, which generates heating or cooling by reversing the direction of the applied current. Its compact form factor and bidirectional heating and cooling capability make it suitable for a wide range of applications, including fingertip displays [21, 45, 56] and smart rings [76] for the fingers; gloves [38, 46, 67], wrist-worn [22, 49, 62, 63] and handheld devices [47] for the arms and hands; head- or face-mounted devices [50, 51, 73]; torso-worn systems [18]; and even ear- or nose-mounted interfaces [7, 8, 48].
Beyond thermoelectric actuation, prior work has also explored pneumatic systems that circulate heated or cooled air [9, 11], liquid-based thermal garments [25], mid-air ultrasound heating [64, 69], hybrid hydro-optical techniques combining light and water [30], and chemical or physiological approaches such as alcohol evaporation cooling [27], trigeminal stimulation [8], and pain-based thermal cues [32].
Despite this diversity of actuation methods, the responsiveness of thermal interfaces remains fundamentally constrained by the slow dynamics of heat transfer. Conventional Peltier-based systems often require several seconds to produce perceptible temperature changes [21], which can lead to temporal misalignment between thermal feedback and interaction events. To address this limitation, prior work has primarily focused on accelerating physical temperature change through hardware innovation. For example, ThermAirGlove [9] increases cooling speed via forced air circulation, while Flip-Pelt [34] enables rapid bidirectional transitions by mechanically alternating between preconditioned Peltiers. Although effective, these methods often rely on large hardware assemblies or moving parts, which can limit where thermal feedback can be deployed. This constraint is especially acute at the fingertip, where available space is highly limited.
Our work also uses Peltier modules as the primary thermal source, but approaches thermal latency differently. Rather than accelerating physical temperature change through additional hardware complexity, we investigate whether perceived thermal transitions can be accelerated through perceptual design.
2.2 Psychophysics of Thermal Perception
Thermal perception is shaped by both spatial and temporal mechanisms [19, 54, 55]. A classic effect is thermal spatial summation [28, 35, 41, 53], in which thermal inputs distributed across the skin are integrated into a unified percept. Increasing the stimulated area lowers detection thresholds and enhances perceived intensity [74], while multi-point stimulation can bias the perceived temperature of a target location. When adjacent skin regions are exposed to different temperatures, perception integrates these inputs rather than represents them independently, often resulting in a single categorical sensation influenced by the overall spatial pattern [6]. This integration process can reduce sensitivity to local discrepancies, allowing heterogeneous thermal inputs to be perceived as a coherent percept.
Another key mechanism is thermal adaptation [4, 20, 24, 59], which shifts perceptual sensitivity over time. After sustained exposure to a given temperature, detection thresholds change, reducing sensitivity to subsequent stimuli in the same direction [36]. As a result, gradual temperature changes may remain perceptually unnoticed even when the underlying physical temperature has already shifted. These adaptive shifts suggest that intermediate thermal states can sometimes be traversed without immediately altering the dominant percept.
Together, spatial summation and thermal adaptation suggest that thermal perception can be modulated through structured stimulation. These mechanisms create opportunities to bias overall thermal judgments and reduce the apparent perceptual distance between thermal states through spatiotemporal design.
A related direction was explored by Sato et al. [57, 58], who showed that spatially distributed warm and cool stimulation enabled faster thermal perception than uniform stimulation when the skin-temperature change was approximately 2–4 °C. Their demonstration established the promise of spatial thermal design, but several questions remained. The pre-stimulus was separated from the main stimulus by a no-contact interval, making it unclear whether anticipation contributed to the effect. In addition, their evaluations were exploratory, and the apparatus was table-mounted, unsuited to interactive use.
THERMOSAIC extends this direction to participant-calibrated, category-preserving transitions across the 20–40 °C safe operating range. Continuous-contact preconditioning allows us to test conscious detectability directly. Through three powered perceptual studies, we systematically investigate how spatial summation and thermal adaptation can be combined. We further realize this approach in the first standalone fingertip-worn device, approximately 6.7 times smaller than Sato et al.'s table-mounted prototype, and demonstrate its use for accelerating perceived thermal transitions in an interactive VR scenario.
3 Perceptual Basis and Study Logic
THERMOSAIC is based on the idea that accelerating perceived thermal transitions does not require every part of the fingertip to change temperature at the same time. Instead, if some subregions can be shifted toward an upcoming target state while the overall percept remains stable, the remaining physical change required for the final perceptual transition may be reduced. In this way, the goal is not to accelerate physical temperature change itself, but to accelerate the moment at which a new thermal state is perceived.
In this work, fingertip thermal perception is treated in terms of three coarse perceptual categories: cold, neutral, and hot. These categories are not separated by sharp boundaries, but by fuzzy transition zones (Figure 1d) [60]. A thermal transition is therefore defined here not as a precise change in physical temperature, but as the moment when the overall percept crosses from one category into another. THERMOSAIC operates by shifting subregions of the fingertip toward an upcoming target category while preserving the dominant overall percept in the current one.
As discussed in Section 2.2, this strategy depends on two perceptual conditions. First, spatial summation must be sufficient to integrate heterogeneous thermal inputs across the fingertip into a single dominant percept rather than exposing each local deviation independently. If this holds, local subregions can deviate from one another while the overall sensation remains within the same perceptual category. Second, thermal adaptation must be sufficient to allow partial local temperature changes to occur without immediately altering that dominant percept. If this holds, some subregions can be gradually shifted toward a target category while the user still perceives the original state. When these two conditions are combined, subregions of the fingertip may be shifted toward an upcoming target state before the user becomes aware of a transition. The remaining temperature change required to cross the perceptual boundary is then reduced, which may shorten the perceived transition time between categories.
Three perceptual studies were conducted to test these perceptual assumptions. Study 1 examines whether spatially distributed thermal deviations on the fingertip are integrated into a stable overall percept of hot, neutral, or cold. Study 2 examines whether, after sustained exposure, part of the stimulus can drift toward neutrality while the dominant percept remains unchanged. Study 3 then investigates whether combining these effects shortens perceived transition time across thermal categories. To support these perceptual studies, we developed a benchtop 2×2 fingertip thermal setup with independently controlled miniaturized Peltier elements. We use this setup to systematically manipulate thermal subregions
Zhang et al.
and test the perceptual basis under controlled conditions, before translating the same design logic into a standalone wearable implementation.
4 Benchtop Experimental Setup
To test the perceptual basis of THERMOSAIC, we developed a benchtop 2×2 fingertip thermal setup (Figure 2a) composed of four independently controlled miniaturized Peltier elements. The setup enables systematic manipulation of local thermal subregions on the fingertip while maintaining sufficient spatial resolution for the perceptual studies described in Section 3.

Figure 2: (a) Benchtop setup for fingertip thermal stimulation. (b) Close-up of the fingertip thermal actuator assembly. (c) Thermal activation patterns. (d) Exploded schematic of the fingertip thermal actuator, comprising four resistance temperature detectors (RTDs) embedded in copper blocks, four Peltier modules, and a water block.
4.1 Design Rationale
The setup partitions the fingertip contact area into four independently controlled thermal subregions. A 2×2 layout was chosen as the smallest configuration that enables spatially non-uniform thermal patterns while remaining compact enough for stable fingertip contact. This partition provides sufficient degrees of freedom to test the two perceptual conditions required by THERMOSAIC: whether heterogeneous local inputs are integrated into a single dominant percept, and whether subregions of the contact area can be shifted without immediately altering that percept.
To determine the dimensions of the array, we approximated the contactable fingertip pad as an ellipse with a width of 10 mm and a height of 13 mm. The active contact area was then modeled as a 45°-rotated square inscribed within this ellipse, yielding an effective side length of approximately 7.07 mm. Dividing this area into a 2×2 layout gives subregions of roughly 3.5 mm per side. We therefore selected the 3.2 mm × 3.2 mm Peltier modules to closely match the target subregion dimensions.
The 2×2 layout offers two possible pairwise configurations for generating non-uniform thermal patterns (Figure 2c): adjacent and diagonal. Through formative observations, we found that both pairings produced broadly similar percepts. We therefore adopted diagonal grouping, which provides a more balanced spatial distribution and enables two interleaved thermal groups to be driven toward different temperatures without forming a localized cluster.
4.2 Hardware Implementation
The experimental setup consisted of four Peltier modules (Custom Thermoelectric LLC, model 00701-9A30-14RU3) arranged in
a 2×2 diamond array (Figure 2b). Each Peltier was topped with a CNC-milled copper block of matching size, which served as the thermal contact layer and contained a pocket for an embedded resistance temperature detector (RTD; Yageo Nexensos, model 5157701) to measure the fingertip–Peltier interface temperature without obstructing skin contact. A customized 3D-printed water block beneath the array independently cooled each Peltier in a closed, reservoir-free loop containing approximately 12 mL of working fluid, reducing thermal interference (Figure 2d).
Thermally conductive adhesive (MG Chemicals, model 8329TFF) was applied at the interfaces between the copper–RTD, copper–Peltier, and Peltier–water block to ensure mechanical bonding and enhance heat transfer. The assembled device was secured to a flat surface during the studies to ensure stable operation and consistent fingertip–device contact.
4.3 Thermal Control and Performance
Each Peltier module was regulated independently by a PID controller that continuously adjusted PWM duty cycle to minimize the error between target and measured temperature. Because heating and cooling exhibit different thermal dynamics, we used asymmetric PID control with separate gain parameters for heating and cooling. Tuning was initialized using the Ziegler–Nichols method and refined manually to balance responsiveness and stability.
To ensure safe and consistent operation, actuator outputs were constrained to a 20–40 °C range, spanning the perceptually relevant thermal categories while preventing discomfort [23, 42]. An overheating protection mechanism also monitored each module's surface temperature in real time and automatically reduced or suspended PWM output if excessive heating was detected.
The thermal dynamics of the setup were characterized using repeated step responses. The mean heating and cooling rates were 2.04 °C/s (SD = 0.24) and 2.07 °C/s (SD = 0.22), respectively. Steady-state error remained within ±0.3 °C across modules, with a maximum deviation below 0.7 °C. Additional ramp-rate data are provided in Appendix A.
5 Thermal Perceptual Studies
To test the perceptual basis of THERMOSAIC, we conducted three perceptual studies within a single experimental session. The studies progress from spatial integration, to maintenance of a dominant percept under partial thermal change, and finally to perceived transition time between thermal categories. All studies were approved by our institution's Institutional Review Board (IRB).
5.1 Participants
We recruited 15 participants (7 male, 8 female) with a mean age of 26.7 years (SD = 2.87). All reported normal thermal sensitivity and no injuries to their fingertips or hands. Fourteen were right-hand dominant. All participants provided written informed consent and received US $40 as compensation.
5.1.1 Power Analysis and Sample Size Justification. All three studies were conducted with the same group of participants. Thus, the sample size was determined based on the most demanding statistical requirements across studies. Study 1 involved near-ceiling categorical identification, where power analysis is not informative. The design therefore emphasized repeated observations per participant. For Study 2, power was estimated via simulation using a generalized linear mixed-effects model matching the planned analysis. A conservative detection probability () was assumed to reflect near-chance detection under masking. For Study 3, simulations matched the planned linear mixed-effects model and targeted a minimal meaningful effect corresponding to a 1.0 s reduction in detection time. Both analyses indicated that participants achieved power greater than 0.80. We therefore recruited participants to provide a margin above the minimum required sample size, allowing for potential exclusions and supporting stable mixed-effects estimation across studies.
5.2 Shared Experimental Protocol
All perceptual studies were conducted with the same participant group using a within-subjects design and the benchtop experimental setup in Section 4. The studies took place in a quiet laboratory room maintained at °C. Participants were seated at a desk with both hands placed on an armrest to stabilize fingertip contact. No external airflow or heat sources were present.
Before Study 1, we calibrated four thermal category thresholds for each participant, (cold anchor), (cold–neutral boundary), (neutral–hot boundary), and (hot anchor) (Figure 1d, see Appendix B for details of the calibration procedure). Three temperature categories, cold, neutral, and hot, were then defined based on these participant-specific threshold boundaries. This calibration accounted for inter-individual variability in thermal sensitivity and established more comparable perceptual conditions across participants than applying identical absolute temperatures [1, 16]. Similar procedures have been widely used to match subjective sensation levels in psychophysical and applied thermal studies [15, 17, 70]. The resulting calibrated values were used throughout all three studies.
In all studies, participants used the index fingers of both hands. The index fingertip was chosen as the test site because it is among the most thermally sensitive regions of the hand [65], and sensitivity differences between the left and right fingertips are negligible [44]. Participants were instructed to alternate between the left and right index fingertips across trials to provide additional recovery time for each fingertip and help reduce local fatigue. The starting hand was counterbalanced across participants.
5.3 Study 1: Spatial Integration of Heterogeneous Thermal Inputs
Study 1 tested whether spatially heterogeneous stimulation across the diagonally split pattern is integrated into a single categorical percept on the fingertip. We hypothesized that, compared to the baseline condition in which all four Peltier modules produced a uniform temperature, the diagonally split pattern would preserve categorical identification of cold, neutral, and hot sensations despite local temperature differences across subregions.
5.3.1 Study Conditions.
After the calibration procedure described in Section 5.2, the four participant-specific thermal category thresholds () were used to define the study conditions.
For each thermal category, we compared a uniform pattern (baseline) with a diagonally split pattern (test condition), as shown in Figure 3a. In the baseline condition, all four Peltier modules were
set to the same temperature: cold was set to , hot was set to , and neutral was defined as the mean of and .
The test conditions implemented the proposed diagonally split pattern by assigning different temperatures to the two diagonal groups. All temperatures are reported in °C. For neutral, we used two heterogeneous variants: one with the diagonals set to and , and one with the diagonals set to and . For cold, the two diagonals were set to 20 and . For hot, the two diagonals were set to 40 and . These values were chosen to create pronounced local temperature deviations while keeping the overall pattern near the intended thermal category. Milder alternatives would therefore be expected to cause less disruption. Specifically, 20 and 40 represented the lower and upper actuator bounds used in the setup, while the offsets around , and introduced modest within-category deviations.
5.3.2 Procedure.
Before the main experiment, participants completed two sample trials to familiarize themselves with the sensations and the response procedure.
To minimize temporal adaptation and fatigue, a permuted-block randomization was used: the seven experimental conditions were grouped into a super-block, randomly ordered within each block, and repeated three times, yielding 21 trials per participant. For each test condition involving two temperatures, the assignment of temperatures to the two diagonals of the 2x2 array was counterbalanced across participants. Hand order followed the shared experimental protocol described in Section 5.2.
In each trial, participants placed the designated fingertip in full contact with the four copper surfaces for 4 seconds. After lifting their finger, they reported the perceived temperature by selecting the category that best matched their sensation and rating it with the highest confidence. To reduce thermal adaptation, a 10-second rest interval was inserted between trials, and a two-minute break was provided between super-blocks. Including introduction, calibration, and debriefing, the study lasted approximately 20–25 minutes.
5.3.3 Results and Analysis.
The primary outcome measure is categorical identification accuracy. Across all trials, participants reported experiencing a single, uniform temperature sensation. None was able to detect or distinguish any localized temperature variation among the four modules.

Figure 3: Study 1 experimental conditions and outcomes. (a) Applied temperature profiles for each condition. (b) Accuracy of categorizing perceived thermal sensations.
Results are shown in Figure 3b. For neutral stimuli, accuracy reached 100% (SD = 0%) in the baseline condition and remained comparably high in the test condition at 95.6% (SD = 7.6%). For
Zhang et al.
cold stimuli, mean accuracy was 93.3% (SD = 13.8%) in the baseline condition and 100% (SD = 0%) in the test condition. For hot stimuli, accuracy was consistently 100% (SD = 0%) in both the baseline and the test conditions.
Error patterns were further examined using confusion matrices. In the baseline cold condition, the majority of errors occurred when cold was misclassified as neutral. In contrast, in the test cold condition, no such errors were observed. Errors in neutral and hot conditions were rare and not systematically biased toward any single category.
As participants performed the categorization task with near-perfect accuracy across all conditions, we also computed accuracy for each participant as the proportion of correctly identified trials in the baseline and test conditions. To evaluate the effect of the diagonal actuation pattern, we analyzed the paired accuracy difference between the test and the baseline condition.
Confidence intervals for were estimated using bootstrap resampling across participants with 20,000 iterations, providing distribution-free uncertainty estimates appropriate for near-ceiling performance. The mean paired accuracy difference between the test and the baseline was 0.0, with a 95% bootstrap confidence interval of . This interval lies entirely within the predefined equivalence margin ( ), supporting both equivalence and non-inferiority of the diagonally split pattern (test condition) relative to the uniform pattern (baseline).
These results indicate that the diagonally split pattern preserves categorical temperature identification, consistent with stable thermal perceptual categories despite spatially deviant actuation.
5.4 Study 2: Maintenance of a Dominant Thermal Percept
Study 2 tested whether a dominant hot or cold percept could be maintained when part of the fingertip input was shifted toward neutrality. We hypothesized that, after sustained exposure to an initial thermal category, partial local changes would not necessarily be reported as a perceptual transition, especially when the thermal pattern remained spatially balanced across the fingertip.
5.4.1 Study Conditions. Each trial consisted of two phases, as shown in Figure 4a. In Phase 1 (0–10 s), the Peltier array rendered an initial thermal pattern to establish a dominant percept. In Phase 2 (10–20 s), a second thermal pattern was presented to test whether participants would report a perceptual change between the two phases.
Several conditions were defined. Condition 1 served as a no-change baseline, where the full array remained neutral across the two phases. Conditions 2 and 3 served as large-change baselines: the array began in a cold or hot pattern in Phase 1 and changed uniformly to neutral in Phase 2. These conditions were expected to elicit reports of temperature change and therefore served as sensitivity controls.
Conditions 4–7 were the test conditions. In Conditions 4 and 5, Phase 1 established a cold percept. In Phase 2, the pattern was partially shifted toward the upper boundary of the neutral zone, closest to hot, to test whether this partial shift would trigger a noticeable
perceptual change. Condition 4 changed only the diagonal group at , raising it to , while the diagonal group at 20 remained unchanged. Condition 5 changed both diagonal groups, lowering the group at to 20 and raising the group at 20 to . Conditions 6 and 7 followed the same logic from a hot initial state. In Phase 2, the pattern was shifted toward the lower boundary of the neutral zone, closest to cold, to test whether a noticeable perceptual change would be detected.
Both cooling and heating ramp rates were fixed at across all conditions. Each trial lasted 20 seconds. The initial pattern was maintained during Phase 1 (0–10 s), after which the Phase 2 pattern was applied and maintained for the remaining 10 seconds based on the assigned condition.
5.4.2 Procedure. Following the same block structure as in Study 1, the seven experimental conditions were grouped into a super-block, randomized within each block, and repeated three times, resulting in 21 trials per participant. The temperature assignments for the two diagonal groups were counterbalanced across participants. Starting hand was counterbalanced between participants as described in Section 5.2. Before the main experiment, participants completed two practice trials to familiarize themselves with the task.
In each trial, participants placed the designated fingertip in full contact with the four copper surfaces. They were informed of the initial temperature category and then maintained contact for 20 seconds. After lifting their finger, they reported whether they had noticed any temperature change during the trial and, if so, identified the final temperature category they perceived. A 20-second rest interval was inserted between trials, and a three-minute break was provided between super-blocks. The study lasted approximately 40-45 minutes.
5.4.3 Results and Analysis. Detection responses were analyzed using a logistic mixed-effects model with Condition as a fixed effect and participant as a random intercept. We report model-estimated detection probabilities with 95% confidence intervals, and model-based odds ratios (OR) as effect-size estimates. Results are shown in Figure 4b.
| conditions | phase 1 (0-10 s) | phase 2 (10-20 s) |
|---|---|---|
| pattern | temperature | |
| baseline 1 | Mean(N, Nj) (e.g. 30.5°C) | Mean(N, Nj) (e.g. 30.5°C) |
| baseline 2 | ||
| baseline 3 | ||
| test 4 | ||
| test 5 | ||
| test 6 | ||
| test 7 |

Figure 4: Study 2 experimental conditions and outcomes. (a) Applied temperature profiles for each condition. (b) Model-estimated probabilities of reporting a temperature change across conditions.
In the no-change baseline (Condition 1), the estimated probability of reporting a temperature change was low (2.1%, 95% CI [0.3%,
13.6%)], indicating a low false-alarm rate. In contrast, the large-change controls produced high detection probabilities: 85.1% [71.0%, 93.0%] for cold-to-neutral (Condition 2) and 91.6% [79.9%, 96.9%] for hot-to-neutral (Condition 3). These results confirm that participants reliably detected salient temperature transitions.
The balanced-shift conditions produced substantially lower detection probabilities. For cold-origin trials, the estimated probability was 6.3% [2.0%, 18.3%] (Condition 5), compared with 85.1% in the corresponding large-change control, a large reduction in the odds of reporting a change (OR = 0.012, 95% CI [0.003, 0.051], p < .001). For hot-origin trials, the estimated probability was 4.2% [1.0%, 15.6%] (Condition 7) compared with 91.6% in the corresponding control (OR = 0.004, 95% CI [0.001, 0.024], p < .001). Under balanced shifts, participants thus largely maintained the original dominant percept despite substantial changes in the underlying stimulation.
The unilateral-shift conditions showed intermediate detection probabilities: 37.4% [23.8%, 53.2%] for cold-origin trials (Condition 4) and 51.2% [35.9%, 66.2%] for hot-origin trials (Condition 6). Although these conditions also reduced the odds of reporting a change relative to the large-change controls (cold-origin: OR = 0.104, 95% CI [0.037, 0.294], p < .001; hot-origin: OR = 0.096, 95% CI [0.029, 0.320], p < .001), their detection probabilities remained much higher than those of the balanced-shift conditions.
As a complementary descriptive analysis, we computed signal-detection sensitivity () using the no-change condition (Condition 1) as the shared false-alarm baseline, with log-linear correction. The large-change controls showed high sensitivity (cold-origin: ; hot-origin: ). Balanced-shift conditions showed low sensitivity (cold-origin: ; hot-origin: ), consistent with these changes being largely masked by the dominant thermal percept, while unilateral shifts produced intermediate values (cold-origin: ; hot-origin: ).
Taken together, these findings suggest that perceptual stability is more reliably preserved when changes in thermal input are spatially balanced. Specifically, when temperatures in the diagonal regions shifted in opposing directions, spatial integration maintained a dominant categorical percept, and gradual local changes largely went unnoticed. This pattern is consistent with an adaptation-based account in which sensitivity to covert changes is reduced when the overall spatial structure of the thermal pattern remains stable.
5.5 Study 3: Perceived Transition Time Between Thermal Categories
Study 3 tested the core claim of THERMOSAIC: whether combining spatial integration and adaptation can shorten the time required to perceive a transition between thermal categories. Building on Study 2, we hypothesized that the effect would be strongest when the initial state was already categorically established as cold or hot, and weaker or absent when the initial state was neutral.
5.5.1 Study Conditions. We examined all ordered transitions between the three temperature categories, yielding six transition conditions: neutral-to-hot, neutral-to-cold, cold-to-neutral, cold-to-hot, hot-to-neutral, and hot-to-cold (Figure 5a). The six transition conditions were instantiated using the participant-specific thresholds established in Section 5.2.
Each trial consisted of three phases. In Phase 1 (0–5 s), the array rendered a stable thermal pattern corresponding to the starting category. In Phase 2 (5–10 s), the baseline condition maintained this initial pattern, whereas the test condition applied the proposed diagonal preconditioning pattern. In Phase 3 (10–20 s), both baseline and test conditions transitioned to the target category.
In the baseline condition, all four Peltier modules were driven uniformly. Building on the manipulations introduced in Studies 1 and 2, the test condition applied a diagonally split pattern that introduced a partial, spatially heterogeneous shift during Phase 2 before the full transition occurred in Phase 3.
5.5.2 Procedure. The study was divided into two parts. In Part 1, all trials began at a neutral temperature. In Part 2, trials began at either a cold or a hot temperature. Participants completed two practice trials to familiarize themselves with the procedure before the main experiment. The starting hand was counterbalanced between participants as described in Section 5.2.
Before each trial, participants were informed of the transition type. They then placed the index finger on the device. Once they confirmed that the rendered sensation matched the instructed initial state, the 20-second trial began. Participants were instructed to press a button as soon as they detected a shift to the target temperature. Response time was recorded automatically as the interval between the programmed onset of the temperature shift and the button press.
Following the same block structure as in Study 1, Part 1 grouped four conditions into a super-block, randomized within each block and repeated three times, yielding 12 trials per participant. Part 2 included eight experimental conditions per super-block, randomized within each block, and repeated three times, resulting in 24 trials per participant. A 30-second rest interval was provided between trials, a three-minute break between super-blocks, and a five-minute break between the two parts of the study. In total, each participant completed 36 trials, and the study lasted approximately 50 minutes.
5.5.3 Results and Analysis. Detection times between baseline and test conditions were analyzed using a linear mixed-effect model. The model included Group (baseline vs. test), Transition (six temperature transitions as shown in Figure 5a), and their interaction as fixed effects, with participant treated as a random effect to account for repeated measures and individual differences. Degrees of freedom were estimated using the Kenward–Roger approximation. As effect-size estimates for the omnibus effects, we report approximate partial eta-squared values () computed from the Type III F statistics. Results are shown in Figure 5b.
This linear mixed-effects analysis revealed a significant main effect of Group (), a significant main effect of Transition (), and a significant Group Transition interaction (), indicating that the effect of Group differed across Transition types.
Post-hoc comparisons based on estimated marginal means (Kenward–Roger correction) showed that detection times were consistently shorter in the test condition than in the baseline condition for transitions originating from non-neutral thermal states.
Zhang et al.
For cold-origin transitions, detection time decreased from 5.60 s in the baseline condition to 3.75 s in the test condition for cold-to-hot transitions (95% CIs [5.01, 6.19] and [3.16, 4.34], respectively; s, , ), and from 4.69 s in the baseline condition to 2.75 s in the test condition for cold-to-neutral transitions (95% CIs [4.10, 5.28] and [2.16, 3.34], respectively; s, , ).
Similarly, for hot-origin transitions, detection time decreased from 6.12 s in the baseline condition to 4.03 s in the test condition for hot-to-cold transitions (95% CIs [5.53, 6.71] and [3.44, 4.62], respectively; s, , ), and from 4.59 s in the baseline condition to 3.30 s in the test condition for hot-to-neutral transitions (95% CIs [4.00, 5.18] and [2.71, 3.89], respectively; s, , ).
In contrast, transitions originating from the neutral state showed no reliable differences between conditions. Detection times did not differ significantly between the baseline and test conditions for neutral-to-cold transitions (3.12 s vs. 3.52 s; 95% CIs [2.53, 3.71] and [2.93, 4.11], respectively; s, , ) or neutral-to-hot transitions (3.71 s vs. 3.55 s; 95% CIs [3.12, 4.31] and [2.95, 4.14], respectively; s, , ).

Figure 5: Study 3 experimental conditions and outcomes. (a) Applied temperature profiles for each condition. (b) Time to detect temperature transitions across different conditions.
Overall, these results indicate that perceived transition time can be reduced when the initial thermal state is categorically established as cold or hot. In these cases, the test condition produced reliable reductions of approximately 1.29–2.09 seconds relative to baseline, corresponding to approximately 28%–41% faster detection.
No comparable benefit was observed for transitions originating from the neutral state. This pattern is consistent with the proposed mechanism: preconditioning is most effective when it operates on top of an already dominant thermal percept.
5.6 Summary
Across the three studies, the results support the perceptual basis of THERMOSAIC. Study 1 shows that spatially heterogeneous fingertip stimulation can be integrated into a single categorical percept. Study 2 shows that a dominant hot or cold percept can often be maintained even when part of the stimulation shifts toward neutrality. Study 3 shows that combining these effects can shorten perceived transition time, particularly for transitions originating from an already established hot or cold percept.
6 Wearable Implementation of THERMOSAIC
After validating the perceptual basis of THERMOSAIC with the benchtop experimental setup, we translated the same thermal core into a standalone fingertip-worn device (Figure 6) for interactive use. The wearable preserves the validated 2×2 architecture used in the perceptual studies, including the same 3.2 mm × 3.2 mm Peltier modules, copper blocks with embedded RTD sensors, and water-cooling blocks. This maintains a fingertip contact area of approximately 7 mm × 7 mm while preserving the same independently controlled thermal subregions used in the benchtop studies.
To support wearable operation, we redesigned the surrounding hardware for standalone use. This included a fingertip-sized custom PCB for routing sensing and actuation signals, onboard control electronics, a rechargeable battery power supply, and a custom 3D-printed enclosure. The wearable uses the same water-cooling system and matches the benchtop's ramp performance. The resulting device preserves the validated thermal interface while enabling standalone fingertip wear for the interactive evaluation in Section 7.

Figure 6: THERMOSAIC wearable implementation.
7 VR Evaluation
To evaluate whether the wearable implementation of THERMOSAIC carries the perceptual advantage observed in Section 5 into interactive use, we conducted a VR study comparing THERMOSAIC against a uniform baseline condition. Participants played a mini-game involving repeated hot-to-cold and cold-to-hot transitions triggered by visual events. Our primary question was whether THERMOSAIC would improve the perceived temporal alignment between thermal and visual changes in VR. The study was approved by our institution's IRB.
7.1 Participants
Twelve participants (7 male, 5 female; mean age = 25.3, SD = 3.2) participated in the study. Ten were right-hand dominant. All reported normal thermal sensitivity and no hand injuries. Participants provided written informed consent and received US $20 compensation.
7.2 Apparatus and Procedure
Participants wore a Meta Quest 3 VR headset and the THERMOSAIC wearable (Figure 7a) on the index finger. The water pump and control circuit were attached to the forearm using Velcro straps [75].

Figure 7: (a) Participant wearing the VR headset and THERMOSAIC device. (b-e) VR sequence after defeating a blue scarecrow: a new red scarecrow appears; the participant switches from ice magic to fire magic and uses fire magic to defeat the red scarecrow. (f-i) VR sequence after defeating a red scarecrow: a new blue scarecrow appears; the participant switches from fire magic to ice magic and uses ice magic to defeat the blue scarecrow.
Prior to the study, we calibrated each participant's thermal thresholds to ensure perceptual consistency. Across participants, the resulting thresholds (mean ± SD) were 22.67 ± 0.49 °C for cold anchor, 27.83 ± 0.94 °C for cold-neutral threshold, 33.00 ± 0.74 °C for neutral-hot threshold, and 38.42 ± 0.79 °C for hot anchor. The device operated within a safe range of 20–40 °C with overheat protection. All thermal stimuli were generated with consistent ramp rates of 2 °C/s across conditions.
After calibration, participants completed a brief training session to familiarize themselves with the interaction in VR. They then completed two gameplay rounds, one in the baseline condition and one in the THERMOSAIC condition, with order counterbalanced across participants. After each round, participants completed a short questionnaire assessing perceived synchronization, perceived transition dynamics, and overall immersion. A one-minute break separated the two rounds. The entire study lasted around 60 minutes.
7.3 VR Scenario and Conditions
We designed a VR mini-game in which participants cast magic from their right index finger to defeat scarecrow enemies. Red scarecrows required fire magic, whereas blue scarecrows required ice magic. Participants could carry only one magic type at a time. When carrying fire magic, they felt heat on the index fingertip; when carrying ice magic, they felt coolness at the same spot.
In each gameplay round, participants defeated six scarecrows. The color order was randomized while ensuring two blue-to-red
transitions (Figure 7b-e), two red-to-blue transitions (Figure 7f-i), and one red-to-red sequence. The thermal stimuli corresponding to hot-to-cold and cold-to-hot transitions followed the same patterns used in Study 3.
The two conditions differed in how temperature was rendered. In the baseline condition, all four Peltier modules produced a uniform temperature, approximating a single actuator with the same total contact area. In the THERMOSAIC condition, one diagonal group began shifting toward the upcoming target temperature immediately after a scarecrow was defeated, while the other group remained within the current thermal category. This preserved the dominant percept while preparing a faster subsequent transition. When the participant switched magic type, all four modules were then set to the target thermal pattern.
7.4 Results
We analyzed both quantitative and qualitative data to evaluate how THERMOSAIC, compared to the baseline condition, affected perceived temporal alignment between thermal transitions and visual events in VR.
Synchronization between thermal and visual changes. Participants were asked to rate the synchronization between the visual magic change (i.e., disappearance of the magic orb) and the perceived temperature change (Question 1, Q1) using a 0–100 visual analog scale (VAS). A score of 0 indicated complete asynchrony (i.e., a noticeable delay), whereas a score of 100 indicated near-perfect synchrony (i.e., occurring almost simultaneously). The continuous nature of the VAS allowed participants to express fine-grained differences in perceived temporal alignment while reducing potential ceiling effects.

Figure 8: (a) VAS ratings for Q1 ("How synchronized did the magic switch and the temperature change feel?") at baseline and under the THERMOSAIC condition. (b) Violin plot of individual improvements for VAS (THERMOSAIC – baseline).
Participants reported significantly improved perceived synchronization under the THERMOSAIC condition compared to the baseline. As shown in Figure 8, VAS ratings increased by an average of 19.58 points (SD = 15.14), with a 95% confidence interval of [11.01, 28.15]. A paired t-test confirmed this difference to be statistically significant (), with a large effect size (Cohen's ).
Questions 2–7 are shown in Figure 9. For Q2, participants reported high confidence in their judgments, with no significant difference between conditions (), suggesting that the observed improvement in synchrony perception is reliable and not driven by uncertainty or response noise.
Zhang et al.

Figure 9: Participant Likert-scale responses for confidence (Q2), perceived visual abruptness (Q3, Q5), perceived thermal abruptness (Q4, Q6), and perceived thermal lag (Q7).
Modality-specific perception of transition dynamics. We examined how participants perceived the temporal dynamics of both visual and thermal changes across conditions.
For visual transitions, participants consistently rated the disappearance of the magic orb as sudden instead of gradual, with low mean ratings in both conditions (Q3, change to fire magic: baseline = 1.42 ± 0.19, THERMOSAIC = 1.50 ± 0.19; Q5, change to ice magic: baseline = 1.50±0.23, THERMOSAIC = 1.42±0.19), and no significant differences between conditions (p > 0.5). These results suggest that visual changes were perceived as nearly instantaneous across conditions.
In contrast, thermal perception differed substantially across conditions. Under the baseline condition, temperature changes were perceived as more gradual (Q4, change to fire magic: 6.00 ± 0.21; Q6, change to ice magic: 5.92 ± 0.19), whereas under THERMOSAIC, participants reported significantly more sudden transitions (Q4: 3.08 ± 0.43, p < .001; Q6: 3.33 ± 0.43, p < .001). This indicates that TherMosaic alters how temperature transitions are subjectively experienced, leading to a perception of more abrupt changes compared to the baseline. This shift suggests a closer perceptual coupling between thermal changes and the rapid visual events.
Additionally, participants were significantly less likely to report that temperature changes lagged behind visual transitions under THERMOSAIC (Q7: baseline = 5.67 ± 0.31, THERMOSAIC = 3.17 ± 0.53, p = .003). This effect was consistent across both transition directions, suggesting that temperature changes are perceived as occurring more promptly under THERMOSAIC.
Qualitative feedback. Qualitative feedback revealed a clear preference for the faster thermal transitions enabled by THERMOSAIC. Participants described these transitions as more consistent with the visual feedback and less disruptive to the experience. P2 noted that the slower baseline transitions felt “weird” because the perceived temperature no longer matched the visual state, while P12 stated that the faster changes “match[ed] the visual magic
better and feel[ed] more immersive.” P3 further emphasized the functional impact of lag: “I do feel it affects me because if there is a delay, I’m not able to tell whether I caught the magic in my hand or not.” These comments further support the quantitative findings that THERMOSAIC improved temporal coherence between thermal and visual feedback.
8 Discussion and Limitations
Across three perceptual studies and a VR evaluation, our findings suggest that thermal latency can be addressed not only through improving hardware, but also through spatiotemporal thermal design. In the following, we interpret the perceptual mechanism suggested by these results, along with the practical limitations and future directions of THERMOSAIC.
8.1 Interpreting the Perceptual Mechanism
One plausible explanation for the observed effect is the interaction among several known properties of thermal perception. Thermal perception has relatively low spatial resolution, so distributed inputs across the fingertip may be integrated into a single dominant percept rather than being independently resolved. It is also often categorical, meaning that localized changes do not necessarily alter the perceived category immediately. In addition, thermal adaptation may reduce sensitivity to gradual local changes, allowing part of the stimulus to shift toward a target temperature without becoming salient. Together, these factors may allow local changes to remain perceptually masked within the dominant overall percept, reducing the remaining change required before the percept crosses into a new category.
This interpretation is consistent with our three perceptual studies, which together support integration, perceptual stability under partial local change, and reduced transition time. While further work is needed to fully characterize the underlying mechanism, these results suggest that THERMOSAIC works by preconditioning part of the fingertip toward an upcoming target state before the full transition is consciously perceived.
8.2 Limitations and Future Directions
8.2.1 Scheduling. One limitation of THERMOSAIC is that for interactive use, it works best when upcoming thermal transitions can be anticipated. In our VR study, this was feasible because the interaction sequence explicitly controlled when temperature changes occurred. In more dynamic or spontaneous interactions, however, achieving the same effect may require a more sophisticated scheduling algorithm.
Future work could explore predictive control strategies that integrate user interaction modeling with real-time context awareness, as exemplified by scheduling approaches in [66]. A similar framework for THERMOSAIC may anticipate upcoming temperature transitions and adapt feedback timing without breaking immersion.
8.2.2 Scalability of Contact Area. The current THERMOSAIC prototype targets a single fingertip, which was appropriate for isolating the perceptual mechanism but limits the range of interactions that can be supported. In the VR study, P10 also noted that they expected more finger coverage and believed that involving a larger area would create a more solid sensation.
Future work could extend thermal feedback to multiple fingers or full hands, enabling more immersive experiences such as grasping a warm object, feeling environmental coldness, or differentiating textures across fingers. Higher-density arrays may also support spatial gradients, thermal grill illusions, or thermal textures, though such scalability may introduce additional challenges in weight, cooling efficiency, and power management for a wearable device.
8.2.3 Within-Category Intensity Invariance. THERMOSAIC does not guarantee perfect within-category intensity invariance. Preconditioning may subtly alter perceived intensity within a category even when the categorical percept is preserved. Participants did not spontaneously report such changes in Study 3 or the VR study. Future work should directly quantify within-category intensity changes using continuous intensity ratings, just-noticeable-difference (JND) thresholds, or pairwise discrimination tasks.
8.2.4 Cross-modal Perception. THERMOSAIC shows that leveraging thermal perception alone can reduce perceived temperature transition time by up to 40%. A promising next step is to combine thermal preconditioning with cross-modal cueing, such as visual or potentially auditory cues, to further strengthen this effect. For example, recent work by Günther et al. [26] suggests that visual cues in VR can bias the perceived spatial location of physical thermal stimuli while still preserving authenticity, which implies that coordinated visual context may also help shape the perceived onset and coherence of thermal transitions in interactive environments.
9 Conclusion
We presented THERMOSAIC, a spatiotemporal thermal feedback approach for accelerating perceived thermal transitions on the fingertip by leveraging spatial summation and thermal adaptation. Across three perceptual studies and a VR evaluation, we showed that heterogeneous thermal stimulation can reduce perceived thermal transition time and improve temporal coherence in interactive use. These findings suggest that thermal latency is not solely a hardware limitation, but also an opportunity for perceptually informed interface design.
Acknowledgments
This work was supported in part by the National Science Foundation under Grant No. 2441833. During the preparation of this manuscript, the authors used LLM services to improve the clarity and linguistic flow of the text.
References
[1] Waclaw M. Adamczyk, Tibor M. Szikszay, Hadas Nahman-Averbuch, Jacek Skalski, Jakub Nastaj, Philip Gouverneur, and Kerstin Luedtke. 2022. To Calibrate or not to Calibrate? A Methodological Dilemma in Experimental Pain Research. The Journal of Pain 23, 11 (2022), 1823–1832. doi:10.1016/j.jpain.2022.07.007
[2] Moses Akazue, Martin Halvey, and Lynne Baillie. 2017. Using Thermal Stimuli to Enhance Photo-Sharing in Social Media. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 1, 2, Article 4 (June 2017), 21 pages. doi:10.1145/3090050
[3] Moses Akazue, Martin Halvey, Lynne Baillie, and Stephen Brewster. 2016. The Effect of Thermal Stimuli on the Emotional Perception of Images. In Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems (San Jose, California, USA) (CHI '16). Association for Computing Machinery, New York, NY, USA, 4401–4412. doi:10.1145/2858036.2858307
[4] Shimon Akiyama, Katsunari Sato, Yasutoshi Makino, and Takashi Maeno. 2012. Presentation of thermal sensation through preliminary adjustment of adapting
skin temperature. In 2012 IEEE Haptics Symposium (HAPTICS). 355–358. doi:10.1109/HAPTIC.2012.6183814
[5] Shimon Akiyama, Katsunari Sato, Yasutoshi Makino, and Takashi Maeno. 2013. ThermOn: thermo-musical interface for an enhanced emotional experience. In Proceedings of the 2013 International Symposium on Wearable Computers (Zurich, Switzerland) (ISWC '13). Association for Computing Machinery, New York, NY, USA, 45–52. doi:10.1145/2493988.2494326
[6] Keisuke Arai, Miki Matsumuro, Satoshi Hashiguchi, Fumihisa Shibata, and Asako Kimura. 2021. Hot–Cold Confusion: Inverse Thermal Sensation When Hot and Cold Stimuli Coexist in a Thermal Localization Task. Perception 50, 6 (2021), 508–523. doi:10.1177/03010066211004055 PMID: 33888020.
[7] Jas Brooks, Alex Mazursky, Janice Hixon, and Pedro Lopes. 2024. Augmented Breathing via Thermal Feedback in the Nose. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 26, 11 pages. doi:10.1145/3654777.3676438
[8] Jas Brooks, Steven Nagels, and Pedro Lopes. 2020. Trigeminal-based Temperature Illusions. In Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems (Honolulu, HI, USA) (CHI '20). Association for Computing Machinery, New York, NY, USA, 1–12. doi:10.1145/3313831.3376806
[9] Shaoyu Cai, Pingchuan Ke, Takuji Narumi, and Kening Zhu. 2020. ThermAir-Glove: A Pneumatic Glove for Thermal Perception and Material Identification in Virtual Reality. In 2020 IEEE Conference on Virtual Reality and 3D User Interfaces (VR), 248–257. doi:10.1109/VR46266.2020.00044
[10] Antonio Cataldo, Elisa Raffaella Ferrè, Giuseppe Di Pellegrino, and Patrick Haggard. 2016. Thermal referral: evidence for a thermoceptive uniformity illusion without touch. Scientific reports 6, 1 (2016), 35286. doi:10.1038/srep35286
[11] Rui Chen, Xianlong Mai, Domenico Chiaradia, Antonio Frisoli, and Daniele Leonardis. 2026. A Soft Fabric-Based Thermal Haptic Device for Virtual Reality. IEEE Access 14 (2026), 33651–33664. doi:10.1109/ACCESS.2026.3667732
[12] Jaeyoo Choi, Chaochao Dun, Carlos Forsythe, Madeleine P. Gordon, and Jeffrey J. Urban. 2021. Lightweight wearable thermoelectric cooler with rationally designed flexible heatsink consisting of phase-change material/graphite/silicone elastomer. Journal of Materials Chemistry a 9, 28 (07 2021), 15696–15703. arXiv:https://pubs.rsc.org/ta/article-pdf/9/28/15696/8212738/d1ta01911b.pdf doi:10.1039/d1ta01911b
[13] Simon Corbett, D. Gautam, Swatchith Lal, Kenny Yu, Naveen Balla, Graeme Cunningham, Kafil M. Razeeb, Ryan Enright, and David McCloskey. 2021. Electrodeposited Thin-Film Micro-Thermoelectric Coolers with Extreme Heat Flux Handling and Microsecond Time Response. ACS Applied Materials & Interfaces 13, 1 (2021), 1773–1782. doi:10.1021/acsami.0c16614
[14] Aleph Campos Da Silveira, Eduardo C Rodrigues, Estevao B Saleme, Alexandra Covaci, Gheorghita Ghinea, and Celso AS Santos. 2023. Thermal and wind devices for multisensory human-computer interaction: an overview. Multimedia Tools and Applications 82, 22 (2023), 34485–34512. doi:10.1007/s11042-023-14672-y
[15] Claudia Daudén Roquet and Corina Sas. 2021. Interceptive Interaction: An Embodied Metaphor Inspired Approach to Designing for Meditation. In Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems (Yokohama, Japan) (CHI '21). Association for Computing Machinery, New York, NY, USA, Article 265, 17 pages. doi:10.1145/3411764.3445137
[16] Camila Sardeto Deolindo, Jesper Fischer Ehmsen, Arthur S. Courtin, Alexandra G. Mitchell, Camilla E. Kraenge, Niiia Nikolova, Micah G. Allen, and Francesca Fardo. 2025. Assessing individual sensitivity to the Thermal Grill Illusion: A two-dimensional adaptive psychophysical approach. The Journal of Pain 27 (2025), 104732. doi:10.1016/j.jpain.2024.104732
[17] Yaoyu Duan, Huimin Jiao, Dangxiao Wang, and Xingwei Guo. 2025. A real-time predictive postural control system with temperature feedback. Scientific Reports 15, 1 (2025), 27922. doi:10.1038/s41598-025-11334-x
[18] Abdallah El Ali, Xingyu Yang, Swamy Ananthanarayan, Thomas Rögglä, Jack Jansen, Jess Hartcher-O'Brien, Kaspar Jansen, and Pablo Cesar. 2020. ThermalWear: Exploring Wearable On-chest Thermal Displays to Augment Voice Messages with Affect. In Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems (Honolulu, HI, USA) (CHI '20). Association for Computing Machinery, New York, NY, USA, 1–14. doi:10.1145/3313831.3376682
[19] Davide Filingeri. 2016. Neurophysiology of Skin Thermal Sensations. Comprehensive Physiology 6, 3 (2016), 1429–1491. doi:10.1002/j.2040-4603.2016.tb00715.x
[20] Davide Filingeri, Hui Zhang, and Edward A. Arens. 2017. Characteristics of the local cutaneous sensory thermoneutral zone. Journal of Neurophysiology 117, 4 (2017), 1797–1806. doi:10.1152/jn.00845.2016 PMID: 28148644.
[21] Massimiliano Gabardi, Domenico Chiaradia, Daniele Leonardis, Massimiliano Solazzi, and Antonio Frisoli. 2018. A High Performance Thermal Control for Simulation of Different Materials in a Fingertip Haptic Device. In Haptics: Science, Technology, and Applications, Domenico Prattichetti, Hiroyuki Shinoda, Hong Z. Tan, Emanuele Ruffaldi, and Antonio Frisoli (Eds.). Springer International Publishing, Cham, 313–325. doi:10.1007/978-3-319-93399-3_28
[22] Haichen Gao, Shaoyu Cai, Yuhong Wu, and Kening Zhu. 2024. ThermOuch: A Wearable Thermo-Haptic Device for Inducing Pain Sensation in Virtual Reality through Thermal Grill Illusion. In SIGGRAPH Asia 2024 Conference Papers (Tokyo,
Zhang et al.
Japan) (SA '24). Association for Computing Machinery, New York, NY, USA, Article 138, 12 pages. doi:10.1145/3680528.3687620
[23] Qiuqing Geng, Ingar Holmer, Den EA Hartog, George Havenith, O Jay, Jacques Malchaire, Alain Piette, H Rintamäki, and S Rissanen. 2006. Temperature Limit Values For Touching Cold Surfaces with the Fingertip. The Annals of Occupational Hygiene 50, 8 (06 2006), 851–862. arXiv:https://academic.oup.com/anwwh/article-pdf/50/8/851/362350/mel030.pdf doi:10.1093/annhyg/mel030
[24] Barry G. Green and Carol Akirav. 2010. Threshold and rate sensitivity of low-threshold thermal nociception. European Journal of Neuroscience 31, 9 (2010), 1637–1645. doi:10.1111/j.1460-9568.2010.07201.x
[25] Sebastian Günther, Florian Müller, Dominik Schön, Omar Elmoghazy, Max Mühlhäuser, and Martin Schmitz. 2020. Therminator: Understanding the Interdependency of Visual and On-Body Thermal Feedback in Virtual Reality. In Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems (Honolulu, HI, USA) ('CHI '20). Association for Computing Machinery, New York, NY, USA, 1–14. doi:10.1145/3313831.3376195
[26] Sebastian Günther, Alexandra Skogseide, Robin Buhlmann, and Max Mühlhäuser. 2024. Assessing the Influence of Visual Cues in Virtual Reality on the Spatial Perception of Physical Thermal Stimuli. In Proceedings of the 2024 CHI Conference on Human Factors in Computing Systems (Honolulu, HI, USA) ('CHI '24). Association for Computing Machinery, New York, NY, USA, Article 635, 12 pages. doi:10.1145/3613904.3642154
[27] Takumi Hamazaki, Taiki Takami, Keigo Ushiyama, Izumi Mizoguchi, and Hiroyuki Kajimoto. 2024. ALCool: Utilizing Alcohol's Evaporative Cooling for Ubiquitous Cold Sensation Feedback. In Proceedings of the 2024 CHI Conference on Human Factors in Computing Systems (Honolulu, HI, USA) ('CHI '24). Association for Computing Machinery, New York, NY, USA, Article 429, 14 pages. doi:10.1145/3613904.3642113
[28] James D. Hardy and Theodore W. Oppel. 1937. Studies in Temperature Sensation. III. The Sensitivity of the Body to Heat and the Spatial Summation of the End Organ Responses. Journal of Clinical Investigation 16, 4 (1937), 533–540. doi:10.1172/JCI100879
[29] Md Shafkat Bin Hoque, Yee Rui Koh, Jeffrey L. Braun, Abdullah Mamun, Zeyu Liu, Kenny Huynh, Michael E. Liao, Kamal Hussain, Zhe Cheng, Eric R. Hoglund, David H. Olson, John A. Tomko, Kiumars Aryana, Roisul Galib, John T. Gaskins, Mirza Mohammad Mahbube Elahi, Zayd C. Leseman, James M. Howe, Tengfei Luo, Samuel Graham, Mark S. Goorsky, Asif Khan, and Patrick E. Hopkins. 2021. High In-Plane Thermal Conductivity of Aluminum Nitride Thin Films. ACS Nano 15, 6 (2021), 9588–9599. doi:10.1021/acsnano.0b0915
[30] Sosuke Ichihashi, Masahiko Inami, Hsin-Ni Ho, and Noura Howell. 2024. Hydropirical Thermal Feedback: Spatial Thermal Feedback Using Visible Lights and Water. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 104, 19 pages. doi:10.1145/3654777.3676453
[31] Jingu Jeong, Mingyu Kang, Youngsup Song, and Soonjae Pyo. 2025. Interactive Haptic System with Multimodal Tactile Sensing and Hydraulic Feedback for Realistic Human–Machine Interaction. Advanced Intelligent Systems 7, 5 (2025), 2400578. doi:10.1002/aisy.202400578
[32] Chutian Jiang, Yanjun Chen, Mingming Fan, Liuping Wang, Luyao Shen, Nianlong Li, Wei Sun, Yu Zhang, Feng Tian, and Teng Han. 2021. Douleur: Creating Pain Sensation with Chemical Stimulant to Enhance User Experience in Virtual Reality. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 5, 2, Article 66 (June 2021), 26 pages. doi:10.1145/3463527
[33] L.A. Jones and M. Berris. 2003. Material discrimination and thermal perception. In 11th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems, 2003. HAPTICS 2003. Proceedings. 171–178. doi:10.1109/HAPTIC.2003.1191267
[34] Seongjun Kang, Gwangbin Kim, Seokhyun Hwang, Jeongju Park, Ahmed Ibrahim Ahmed Mohamed Elsharkawy, and Seungjun Kim. 2024. Flip-Pelt: Motor-Driven Peltier Elements for Rapid Thermal Stimulation and Congruent Pressure Feedback in Virtual Reality. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 103, 15 pages. doi:10.1145/3654777.3676363
[35] Dan R. Kenshalo and E. S. Gallegos. 1967. Multiple Temperature-Sensitive Spots Innervated by Single Nerve Fibers. Science 158, 3804 (1967), 1064–1065. doi:10.1126/science.158.3804.1064
[36] Dan R Kenshalo, Charles E Holmes, and Paul B Wood. 1968. Warm and cool thresholds as a function of rate of stimulus temperature change. Perception & Psychophysics 3, 2 (1968), 81–84. doi:10.3758/BF03212769
[37] Dan R. Kenshalo and Harley A. Scott. 1966. Temporal Course of Thermal Adaptation. Science 151, 3714 (1966), 1095–1096. doi:10.1126/science.151.3714.1095
[38] Seung-Won Kim, Sung Hye Kim, Choong Sun Kim, Kyoungsoo Yi, Jun-Sik Kim, Byung Jin Cho, and Youngsu Cha. 2020. Thermal display glove for interacting with virtual reality. Scientific Reports 10, 1 (2020), 11403. doi:10.1038/s41598-020-68362-y
[39] Kun Lyu, Anastasia Globa, Arianna Brambilla, and Richard de Dear. 2023. An immersive multisensory virtual reality approach to the study of human-built
environment interactions: Technical workflows. MethodsX 11 (2023), 102279. doi:10.1016/j.mex.2023.102279
[40] Shaun Alexander Macdonald, Frank Pollick, and Stephen Anthony Brewster. 2022. The Impact of Thermal Cues on Affective Responses to Emotionally Resonant Vibrations. In Proceedings of the 2022 International Conference on Multimodal Interaction (Bangalore, India) (ICMI '22). Association for Computing Machinery, New York, NY, USA, 259–269. doi:10.1145/3536221.3556572
[41] Lawrence E. Marks. 1974. Spatial Summation in the Warmth Sense. Springer Netherlands, Dordrecht, 369–378. doi:10.1007/978-94-010-2245-3_36
[42] N.A. Martin and S. Falder. 2017. A review of the evidence for threshold of burn injury. Burns 43, 8 (2017), 1624–1639. doi:10.1016/j.burns.2017.04.003
[43] Alex Mazursky, Jas Brooks, Beza Desta, and Pedro Lopes. 2024. ThermalGrasp: Enabling Thermal Feedback even while Grasping and Walking. In 2024 IEEE Conference Virtual Reality and 3D User Interfaces (VR). 342–353. doi:10.1109/VR58804.2024.00056
[44] Niamh A. Moloney, Toby M. Hall, Tomas C. O'Sullivan, and Catherine M. Doody. 2011. Reliability of thermal quantitative sensory testing of the hand in a cohort of young, healthy adults. Muscle & Nerve 44, 4 (2011), 547–552. arXiv:https://onlinelibrary.wiley.com/doi/pdf/10.1002/mus.22121 doi:10.1002/mus.22121
[45] Masashi Nakatani, Katsunari Sato, Kunio Sato, Yuzuru Kawana, Daisuke Takai, Kouta Minamizawa, and Susumu Tachi. 2016. A novel multimodal tactile module that can provide vibro-thermal feedback. In International AsiaHaptics conference. Springer Singapore, Singapore, 437–443. doi:10.1007/978-981-10-4157-0_73
[46] Arshad Nasser and Khalad Hasan. 2024. ThermoGrasp: Enabling Localized Thermal Feedback on Fingers for Precision Grasps in Virtual Reality. Proc. ACM Hum-Comput. Interact. 8, MHCI, Article 279 (Sept. 2024), 21 pages. doi:10.1145/3676526
[47] Arshad Nasser, Kai-Ning Keng, and Kening Zhu. 2020. ThermalCane: Exploring Thermotactile Directional Cues on Cane-Grip for Non-Visual Navigation. In Proceedings of the 22nd International ACM SIGACCESS Conference on Computers and Accessibility (Virtual Event, Greece) (ASSETS '20). Association for Computing Machinery, New York, NY, USA, Article 20, 12 pages. doi:10.1145/3373625.3417004
[48] Arshad Nasser, Kexin Zheng, and Kening Zhu. 2021. ThermEarhok: Investigating Spatial Thermal Haptic Feedback on the Auricular Skin Area. In Proceedings of the 2021 International Conference on Multimodal Interaction (Montréal, QC, Canada) (ICMI '21). Association for Computing Machinery, New York, NY, USA, 662–672. doi:10.1145/3462244.3479922
[49] Roshan Lalitha Peiris, Yuan-Ling Feng, Liwei Chan, and Kouta Minamizawa. 2019. ThermalBracelet: Exploring Thermal Haptic Feedback Around the Wrist. In Proceedings of the 2019 CHI Conference on Human Factors in Computing Systems (Glasgow, Scotland Uk) ('CHI '19). Association for Computing Machinery, New York, NY, USA, 1–11. doi:10.1145/3290605.3300400
[50] Roshan Lalitha Peiris, Wei Peng, Zikun Chen, Liwei Chan, and Kouta Minamizawa. 2017. ThermoVR: Exploring Integrated Thermal Haptic Feedback with Head Mounted Displays. In Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems (Denver, Colorado, USA) ('CHI '17). Association for Computing Machinery, New York, NY, USA, 5452–5456. doi:10.1145/3025453.3025824
[51] Kirill Ragozin, Xiaru Meng, Roshan Lalitha Peiris, Katrin Wolf, George Chernyshov, and Kai Kunze. 2022. ThermoQuest - A Wearable Head Mounted Display to Augment Realities with Thermal Feedback. In Proceedings of the 20th International Conference on Mobile and Ubiquitous Multimedia (Leuven, Belgium) (MUM '21). Association for Computing Machinery, New York, NY, USA, 62–66. doi:10.1145/3490632.3490649
[52] Nimesha Ranasinghe, Meetha Nesam James, Michael Gecawicz, Jonathan Bland, and David Smith. 2020. Influence of Electric Taste, Smell, Color, and Thermal Sensory Modalities on the Liking and Mediated Emotions of Virtual Flavor Perception. In Proceedings of the 2020 International Conference on Multimodal Interaction (Virtual Event, Netherlands) (ICMI '20). Association for Computing Machinery, New York, NY, USA, 296–304. doi:10.1145/3382507.3418862
[53] Andrew J Rózsa and Dan R Kenshalo. 1977. Bilateral spatial summation of cooling of symmetrical sites. Perception & Psychophysics 21, 5 (1977), 455–462. doi:10.3758/BF03199502
[54] Sho Sakurai, Yuki Ban, Toki Katsumura, Takuji Narumi, Tomohiro Tanikawa, and Michitaka Hirose. 2014. Communious mouse: a mouse interface to experience emotions in remarks on the web by extending and modulating one's body image. In SIGGRAPH Asia 2014 Emerging Technologies (Shenzhen, China) (SA '14). Association for Computing Machinery, New York, NY, USA, Article 4, 3 pages. doi:10.1145/2669047.2669057
[55] Sho Sakurai, Yuki Ban, Toki Katsumura, Takuji Narumi, Tomohiro Tanikawa, and Michitaka Hirose. 2016. Sharing Emotion Described as Text on the Internet by Changing Self-physiological Perception. In Proceedings of the Fourth International Conference on Human Agent Interaction (Biopolis, Singapore) (HAI '16). Association for Computing Machinery, New York, NY, USA, 145–153. doi:10.1145/2974804.2974825
[56] Katsunari Sato. 2016. Augmentation of Thermal Sensation on Finger Pad Using Stimuli for Finger Side. In Haptics: Perception, Devices, Control, and Applications,
Fernando Bello, Hiroyuki Kajimoto, and Yon Visell (Eds.). Springer International Publishing, Cham, 512–520. doi:10.1007/978-3-319-42321-0_48
[57] Katsunari Sato and Takashi Maeno. 2012. Presentation of Sudden Temperature Change Using Spatially Divided Warm and Cool Stimuli. In Haptics: Perception, Devices, Mobility, and Communication, Poika Isokoski and Jukka Springare (Eds.). Springer Berlin Heidelberg, Berlin, Heidelberg, 457–468. doi:10.1007/978-3-642-31401-8_41
[58] Katsunari Sato and Takashi Maeno. 2013. Presentation of Rapid Temperature Change Using Spatially Divided Hot and Cold Stimuli. Journal of Robotics and Mechatronics 25, 3 (2013), 497–505. doi:10.20965/jrm.2013.p0497
[59] Raf J. Schepers and Matthias Ringkamp. 2009. Thermoreceptors and thermosensitive afferents. Neuroscience & Biobehavioral Reviews 33, 3 (2009), 205–212. doi:10.1016/j.neubiorev.2008.07.009
[60] Marcel Schweiker, Gesche M. Huebner, Boris R. M. Kingma, Rick Kramer, and Hannah Pallubinsky. 2018. Drivers of diversity in human thermal perception—A review for holistic comfort models. Temperature 5, 4 (2018), 308–342. doi:10.1080/23328940.2018.1534490
[61] Ximing Shen, Youichi Kamiyama, Kouta Minamizawa, and Jun Nishida. 2024. DexteriSync: A Hand Thermal I/O Exoskeleton for Morphing Finger Dexterity Experience. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 102, 12 pages. doi:10.1145/3654777.3676422
[62] Yatharth Singhal, Daniel Honrales, and Jin Ryong Kim. 2025. HeatFlow: A Thermal-Tactile Display for Dynamic 2D Thermal Movements. In Proceedings of the 38th Annual ACM Symposium on User Interface Software and Technology (UIST '25). Association for Computing Machinery, New York, NY, USA, Article 61, 18 pages. doi:10.1145/3746059.3747619
[63] Yatharth Singhal, Daniel Honrales, Haokun Wang, and Jin Ryong Kim. 2024. Thermal In Motion: Designing Thermal Flow Illusions with Tactile and Thermal Interaction. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 27, 13 pages. doi:10.1145/3654777.3676460
[64] Yatharth Singhal, Haokun Wang, Hyunjae Gil, and Jin Ryong Kim. 2021. Mid-Air Thermo-Tactile Feedback using Ultrasound Haptic Display. In Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology (Osaka, Japan) (VRST '21). Association for Computing Machinery, New York, NY, USA, Article 28, 11 pages. doi:10.1145/3489849.3489889
[65] Joseph C. Stevens and Kenneth K. Choo. 1998. Temperature sensitivity of the body surface over the life span. Somatosensory & Motor Research 15, 1 (1998), 13–28. doi:10.1080/08990229870925
[66] Shan-Yuan Teng, K. D. Wu, Jacqueline Chen, and Pedro Lopes. 2022. Prolonging VR Haptic Experiences by Harvesting Kinetic Energy from the User. In Proceedings of the 35th Annual ACM Symposium on User Interface Software and Technology (Bend, OR, USA) (UIST '22). Association for Computing Machinery, New York, NY, USA, Article 39, 18 pages. doi:10.1145/3526113.3545635
[67] Haokun Wang, Yatharth Singhal, Hyunjae Gil, and Jin Ryong Kim. 2024. Fiery Hands: Designing Thermal Glove through Thermal and Tactile Integration for Virtual Object Manipulation. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 101, 15 pages. doi:10.1145/3654777.3676457
[68] Haokun Wang, Yatharth Singhal, and Jin Ryong Kim. 2024. Let It Snow: Designing Snowfall Experience in VR. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 8, 2, Article 54 (May 2024), 24 pages. doi:10.1145/3659587
[69] Yida Wang and Yi-Chao Chen. 2023. Non-Contact Thermal Haptics for VR. In Adjunct Proceedings of the 2023 ACM International Joint Conference on Pervasive and Ubiquitous Computing & the 2023 ACM International Symposium on Wearable Computing (Cancun, Quintana Roo, Mexico) (UbiComp/ISWC '23 Adjunct). Association for Computing Machinery, New York, NY, USA, 386–390. doi:10.1145/3594739.3610724
[70] Ella Weik, Regula Neuenschwander, Karin Jensen, Tim F Oberlander, and Christine Tipper. 2022. Placebo and nocobo effects in youth: subjective thermal discomfort can be modulated by a conditioning paradigm utilizing mental states of low and high self-efficacy. British Journal of Pain 16, 1 (2022), 60–70. doi:10.1177/20494637211020042 PMID: 35111315.
[71] Graham Wilson and Stephen A. Brewster. 2017. Multi-moji: Combining Thermal, Vibrotactile & Visual Stimuli to Expand the Affective Range of Feedback. In Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems (Denver, Colorado, USA) (CHI '17). Association for Computing Machinery, New York, NY, USA, 1743–1755. doi:10.1145/3025453.3025614
[72] S. Wiryasart, P. Suksuron, C. Hommalee, A. Siricharoenpanich, and P. Naphon. 2021. Heat transfer enhancement of thermoelectric cooling module with nanofluid and ferrofluid as base fluids. Case Studies in Thermal Engineering 24 (2021), 100877. doi:10.1016/j.csite.2021.100877
[73] Dennis Wolf, Michael Rietzler, Leo Hnatek, and Enrico Rukzio. 2019. Face/On: Multi-Modal Haptic Feedback for Head-Mounted Displays in Virtual Reality. IEEE Transactions on Visualization and Computer Graphics 25, 11 (2019), 3169–3177. doi:10.1109/TVCG.2019.2932215
[74] Gi-Hun Yang, Dong-Soo Kwon, and Lynette A Jones. 2009. Spatial acuity and summation on the hand: The role of thermal cues in material discrimination. Perception & Psychophysics 71, 1 (2009), 156–163. doi:10.3758/APP.71.1.156
[75] Zining Zhang, Jiasheng Li, Zeyu Yan, Jun Nishida, and Huaishu Peng. 2024. JetUnit: Rendering Diverse Force Feedback in Virtual Reality Using Water Jets. In Proceedings of the 37th Annual ACM Symposium on User Interface Software and Technology (Pittsburgh, PA, USA) (UIST '24). Association for Computing Machinery, New York, NY, USA, Article 136, 15 pages. doi:10.1145/3654777.3676440
[76] Kening Zhu, Simon Perrault, Taizhou Chen, Shaoyu Cai, and Roshan Lalintha Peiris. 2019. A sense of ice and fire: Exploring thermal feedback with multiple thermoelectric-cooling elements on a smart ring. International Journal of Human-Computer Studies 130 (2019), 234–247. doi:10.1016/j.ijhcs.2019.07.003
A Ramp-Rate Data
Step response experiment. To characterize dynamic response, we applied repeated square-wave temperature setpoints alternating between and , as shown in Figure 10a. Each step was held long enough for the system to reach steady state before switching. The plotted curve represents the average temperature across four Peltier modules at each timestamp.
Heating and cooling rates were computed from the transient segments using linear fits over the approximately linear portion of the temperature curve (typically between 10%–90% of the step amplitude). Each cycle produced one heating and one cooling estimate; reported values are averaged across multiple cycles.
Multi-module transient behavior. To evaluate inter-module consistency, all four Peltier modules were driven simultaneously through a temperature sequence transitioning from a high (hot) set-point to a low (cold) setpoint and then to an intermediate (neutral) level. Temperatures from each module were recorded and plotted individually to capture variability across modules, as shown in Figure 10b.

Figure 10: THERMOSAIC thermal performance. (a) Average step response between 25–35 °C across four Peltier modules. (b) Individual module responses during heating, cooling, and return to an intermediate setpoint, demonstrating stable convergence to target temperatures.
Representative cold-to-hot and hot-to-cold transitions. We measured the temporal temperature profiles of each Peltier module under representative transition settings, using the cold-to-hot and hot-to-cold transitions from Study 3 (Figure 5a) as typical examples, with the ramp rate fixed at 2 °C/s (Figure 11 and Figure 12).
Each trial consisted of three sequential phases: Phase 1 (0–5 s) representing the initial steady state, Phase 2 (5–10 s) during which the THERMOSAIC preconditioning was triggered, and Phase 3 (10–25 s) capturing the target transition and steady state. These phase durations follow those used in Study 3 to ensure consistency, except that Phase 3 was extended by an additional 5 seconds to allow for more complete observation of the post-transition behavior.
Zhang et al.

Figure 11: Temperature profiles of four Peltier modules during the cold-to-hot transition under (a) baseline and (b) THERMOSAIC conditions. Shaded areas denote SEM (n=5).
We tested two conditions: baseline and THERMOSAIC. For each condition and transition type, the experiment was repeated five times. The plotted curves represent the mean temperature across the five trials for each Peltier module, while the shaded regions indicate the standard error of the mean (SEM), reflecting variability across repetitions. This setup allows us to directly observe ramp rate and the spatial distribution of temperature over time.

Figure 12: Temperature profiles of four Peltier modules during the hot-to-cold transition under (a) baseline and (b) THERMOSAIC conditions. Shaded areas denote SEM (n=5).
B Thermal Calibration Procedure
To ensure reliable perception of cold, neutral, and hot categories for each participant, we calibrated four reference temperatures: cold anchor (C), cold-neutral boundary ( ), neutral-hot boundary ( ), and hot anchor (H). The procedure consisted of the following steps.
Step 1: Initialization. Participants placed their fingertip on the thermal display at a neutral starting temperature (approximately ) to familiarize themselves with the sensation. All stimuli were constrained within a safe operating range (20–40 °C).
Step 2: Estimation using discrete trials. Candidate temperatures near the expected category boundaries were presented in discrete trials. In each trial, the participant contacted the surface for 4 s and reported whether the sensation was cold, neutral, or hot. Based on the response, the researcher adjusted the next temperature in 1 °C increments.
Cold-neutral boundary ( ). Starting from lower temperatures, the stimulus was increased if the response was cold, and decreased if the response was neutral. This process was repeated until identifying the lowest temperature that was consistently judged as neutral.
Cold anchor (C). Starting from much lower temperatures, the stimulus was increased if the response was cold, and decreased if the
response was neutral. This process was repeated until identifying the highest temperature below that was consistently judged as cold across repeated trials was selected as C.
Neutral-hot boundary ( ). Starting from higher temperatures, the stimulus was decreased if the response was hot, and increased if the response was neutral. This process was repeated until identifying the highest temperature that was consistently judged as neutral.
Hot anchor (H). Starting from much higher temperatures, the stimulus was decreased if the response was hot, and increased if the response was neutral. This process was repeated until identifying the lowest temperature above that was consistently judged as hot across repeated trials was selected as H.
Step 3: Verification. The final set was verified by presenting each temperature multiple times in random order. Participants were required to consistently classify each temperature according to its intended category before proceeding to the main experiment.