Manuscript Offprint

arXiv:2609.05405

WearableQA: A Benchmark for Health Reasoning over Real-World Wearable Data

Ji Soo Lee, Xilun Chen, Pierce Chuang, Ashish Shenoy, Jason Wei, Dohwan Ko, Hyunwoo J. Kim, Benoit Corda

Ji Soo Lee1,2,∗,†^{1,2,*,\dagger}, Xilun Chen1,†^{1,\dagger}, Pierce Chuang1^{1}, Ashish Shenoy1^{1}, Jason Wei1^{1}, Dohwan Ko1,3,∗^{1,3,*}, Hyunwoo J. Kim2^{2}, Benoit Corda1^{1}

1^{1}Meta, 2^{2}KAIST, 3^{3}Korea University

*Work done during internship at Meta, †Equal contribution

Recent advances in wearable sensing enable continuous monitoring of physiological and behavioral signals, yet existing benchmarks rarely evaluate whether AI systems can reason over a real user's longitudinal wearable record. We introduce WearableQA, a benchmark comprising 4,084 10-option multiple-choice questions constructed from the wearable time series, blood biomarkers, and demographics of 200 real users, each with up to 500 days of daily measurements. WearableQA preserves authentic wearable distributions that include device noise and inter-individual variability. To evaluate distinct reasoning capabilities, we introduce 16 question types organized along two complementary axes: data versus health reasoning, which distinguishes computation over longitudinal measurements from physiological interpretation; and single- versus cross-signal reasoning, which separates reasoning about individual signals from the integration of multiple signals. To construct reliable questions at scale, we adopt a dual-grounding framework that combines literature-grounded physiological findings with statistically validated population-grounded physiological patterns. This enables the capture of meaningful relationships observed in real-world wearable data. Evaluation of 14 proprietary and open-source LLMs demonstrates that WearableQA effectively differentiates model capabilities, with performance ranging from 19.6% to 72.9% against a 10% chance baseline. Moreover, WearableQA remains far from solved: most models achieve accuracies below 60%. Overall, WearableQA provides a realistic and diagnostic benchmark for evaluating LLM reasoning over real-world wearable data.

Date: September 7, 2026

Correspondence: jislee@kaist.ac.kr, xilun@meta.com, ashishvs@meta.com, corda@meta.com

Data: https://github.com/facebookresearch/WearableQA

Huggingface: https://huggingface.co/datasets/facebook/WearableQA

Meta

Figure

Figure 1 Radar plot for performance of Open-Source models (left) and proprietary models (right) on our WearableQA Benchmark.

1 Introduction

Recent advances in wearable sensing technologies have enabled continuous monitoring of physiological and behavioral signals, including heart rate, sleep, physical activity, and heart rate variability. Combined with the rapid progress of large language models (LLMs) (Hurst et al., 2024; Singh et al., 2025; Anthropic, 2025; DeepMind, 2026; Comanici et al., 2025; Team et al., 2024; Grattafori et al., 2024), daily longitudinal multimodal measurements are increasingly used to support personalized health understanding, lifestyle assessment, and health monitoring (Kim et al., 2024; Merrill et al., 2026; Khasentino et al., 2025; Pillai et al., 2025). Reasoning with wearable data, however, requires more than simply

recalling general health knowledge. The model needs to first identify and compute the information from the noisy longitudinal physiological measurements, and then interpret it in the context of health, which can also be user-specific. Yet, the ability of LLMs to reason over longitudinal wearable data remains underexplored, with only recent studies beginning to investigate this capability (Merrill et al., 2026; Jing et al., 2026; Gwiazda et al., 2026). Systematic benchmarks for evaluating this capability are also scarce. Existing ones largely rely on synthetic or simulated signals rather than real-world wearable measurements. Consequently, it remains unclear whether current LLMs can reason about the daily longitudinal wearable history of a real user and determine what it may imply about the user's health. This limitation is increasingly important as LLM-based health assistants continue to emerge (Narayanswamy et al., 2025; Kim et al., 2024; Narayanswamy et al., 2026; Merrill et al., 2026).

To this end, we introduce WearableQA, a benchmark for data and health reasoning on real-user longitudinal wearable records. WearableQA contains 4,084 multiple-choice questions constructed from 200 real users' wearable measurements collected over hundreds of days per individual, which also integrates complementary blood biomarkers and demographic information. Each instance is grounded in real-user measurements, which naturally capture the inter-individual variability, user-specific baselines across different time spans, and signals. WearableQA is structured to evaluate model capabilities along two axes: reasoning type and signal complexity. Reasoning types include data and health reasoning, where data reasoning computes trends, anomalies, and relationships from the raw wearable measurements, while health reasoning requires clinical and physiological interpretation. Second, the signal complexity axis distinguishes single-signal questions from cross-signal questions, where the latter challenge the model to integrate patterns and information from two or more signals. Together, these axes enable a fine-grained diagnosis of whether model failure arises from the computation over longitudinal measurements, health-related interpretation, or the integration of different signals.

Given the nature of the domain, constructing reliable reasoning questions from longitudinal wearable data at scale is challenging. The questions need to reflect physiological patterns that genuinely arise in real-world data, while allowing the available wearable measurements to be deterministically annotated according to those patterns. To address these challenges, we adopt a dual-grounding framework composed of two complementary sources: Peer-reviewed literature-grounded findings and statistically validated population-grounded patterns from a large cohort. Then these objectives are instantiated on each user's measurements through deterministic computations that are refined through careful audit and feedback loops. Overall, WearableQA comprises 16 question types, evenly divided between data reasoning and health reasoning questions.

Our experiments on WearableQA across 14 proprietary and open-weight models show that the benchmark effectively distinguishes models with widely varying levels of performance, ranging from 72.9% to 19.6% against a 10% chance baseline. WearableQA also enables a fine-grained diagnosis of model capabilities across reasoning type and signal complexity. We observe that models generally fall short in data reasoning when it comes to deriving answers directly from the raw measurements. In addition, cross-signal reasoning remains challenging, with stronger models showing clear drops relative to single-signal reasoning questions, while open-source models generally perform substantially lower on both subsets.

Figure

Figure 2 Overall accuracy by model (CoT, 95% CI).

Figure

Figure 3 Overall taxonomy of WearableQA. Taxonomy for 4,084 questions of real-world user data that span blood, demographics, and time-series wearables. The benchmark covers 16 question types of data-reasoning and health-reasoning.

To sum up, our contributions are summarized as follows:

  • We introduce WearableQA, a benchmark of 4,084 multiple-choice questions grounded in the longitudinal wearable records of 200 real users, together with blood biomarkers, demographic attributes, and cohort-relative context.

  • We propose a dual-grounding construction framework that combines literature-grounded physiological findings with population-grounded physiological patterns to derive deterministic ground truth from real user data, together with systematic quality-control and auditing procedures to ensure reliable and non-trivial reasoning questions.

  • We introduce a diagnostic taxonomy of 16 question types spanning two complementary axes: data reasoning versus health reasoning, and single-signal versus cross-signal reasoning.

  • We provide a comprehensive evaluation of proprietary and open-source LLMs, demonstrating that WearableQA is discriminative and diagnostic of distinct reasoning limitations over real-world wearable data.

References (17)