arXiv:2609.03794cs.ROSep 2026

Manuscript Offprint

arXiv:2609.03794

A comparative study on the accuracy & repeatability of mobile robotic platforms for the delivery of precision NDE measurement

SeyedMohammadAmin Nabi Pour, S. Gareth Pierce, Randika Vithanage, Ehsan Mohseni, David Carswell, Matthew Shields

Abstract

Mobile robotic platforms offer a flexible alternative to fixed manipulators for non destructive evaluation (NDE) of large aerospace structures, but their base-positioning accuracy and how that accuracy should inform deployment has not been assessed under a common, externally referenced protocol. This work presents a laser tracker based evaluation workflow (ground truth ~6 µm) that measures the static and segmented trajectory positioning accuracy of five commercial mobile platforms (KUKA KMP-1500, KUKA KMR, MiR250, Boston Dynamics Spot, Clearpath Husky) under a common protocol. A coupled multi corner calibration recovers the laser to robot transformation and reflector offsets; ordinary least squares over all poses is used, with robust estimation retained only as a blunder check.

Static positioning accuracy ranged from a median of 8.2 mm (KMP-1500) to 63.5 mm (Spot), with the wheel odometry only Husky uncalibratable. Dynamic path following was characterised by cross track error; The component insensitive to temporal alignment which ranged from 6.9 mm (KMP-1500) to 112.1 mm (Spot). Both accuracy and calibratability tracked localisation capability, from the newest LiDAR SLAM platform to map free visual odometry. No configuration meets the ±0.2–1.0 mm aerospace NDE tolerance from the base alone; the results are framed as a design input that sizes the supplementary sensing each platform requires roughly one order of magnitude for the best platform, nearly two for the worst providing a reproducible basis for platform selection rather than a feasibility claim.

1. Introduction

Non-destructive evaluation (NDE) is a multidisciplinary field that underpins many manufacturing and in service quality assurance checks; it is particularly widely deployed in high value structures such as aircraft, pressure vessels, critical infrastructure, nuclear, defence, renewable energy, etc [1], [2].

The aerospace sector relies heavily on NDE to ensure the safety of primary components, including flight control surfaces, fuselages, and propulsion systems, and it is deployed both during initial manufacture and throughout life maintenance, overhaul, and repair (MRO) activities. Strict standards govern the sector to ensure the structural integrity and safety of aircraft components. These standards often involve cumbersome, time consuming procedures to verify each part, especially when dealing with large structures many metres in size. [3]

Robotic systems have been deployed to automate and accelerate NDE data acquisition. Industrial robots equipped with ultrasonic transducers have demonstrated effectiveness for automated inspection of complex curved components such as aero engine blades, achieving high accuracy in both defect detection and thickness measurement [4]. These hardware systems are now being augmented with machine learning techniques to accelerate data interpretation and improve defect detection accuracy [6]. Traditional fixed robotic manipulators are widely used in NDE applications due to their high accuracy and repeatability (typically down to 0.1 mm), guaranteeing excellent spatial registration of NDE data with component geometry. However, such manipulators are inflexible in their programming and typically configured in fixed cells that allow scanning of only a single or limited number of component geometries. Recent advancements in collaborative and mobile robotic platforms have generated interest in using such systems to provide a more flexible approach to NDE measurements, enabling deployment with limited prior knowledge of the component to be scanned [7]. The integration of mobile manipulators (Figure 1.1) into NDE processes could significantly improve flexibility by automating inspection tasks and enabling access to complex geometries, potentially accelerating non-destructive testing procedures while maintaining compliance with stringent aerospace regulations. The authors have recently demonstrated [8] an approach capable of delivering multiple NDE measurement modalities to components of unknown surface geometry using mobile robotic systems.

Figure

Fig 1.1 : KUKA KMR is a mobile manipulator platform.

This approach, however, adds complexity to operations, with one of the primary challenges being the uncertainty of the mobile platform's position within the workspace. This is critical because the positioning of the manipulator depends on the base, which, in this case, is the mobile platform [9].

Mobile manipulators offer promising solutions, especially for tasks involving large structures that traditionally required bulky, stationary industrial robots. By using smaller, more agile mobile manipulators, industries can implement more flexible and scalable manufacturing processes [10]. This study therefore concentrates on the assessment of accuracy and repeatability of multiple popular robotic mobile base units, and assesses the suitability for advanced NDE inspection applications in a more flexible factory environment.

Currently, the International Organisation for Standardisation (ISO) provides documentation outlining standard procedures and requirements for robotic NDT inspection. However, these standards do not specifically address mobile manipulators or how the accuracy of a mobile platform may impact the overall precision of the manipulator it carries [11], [12]. Furthermore, existing ISO standards for mobile service robots primarily focus on obstacle detection and avoidance. They do not extend to aspects such as positional accuracy or repeatability, which are critical in high precision tasks like NDT [13]. This study, therefore, serves to fill this knowledge gap.

To address the lack of standard procedures and reliable data on mobile platform accuracy, this study developed and conducted a systematic evaluation of five mobile platforms (KUKA KMP1500 (Figure 1.5), KUKA KMR (Figure 1.4), MiR250 (Figure 1.2), Boston Dynamics Spot Dog (Figure 1.3), and Clearpath Robotics Husky (Figure 1.6)). The goal was to measure both their static and dynamic accuracy and repeatability under identical experimental conditions to gain a comparative understanding of their potential performance when used as mobile delivery platforms for NDE or manipulators for associated manufacturing.

Figure

Fig 1.2: MiR250.

Fig 1.3: Boston Dynamic Spot Dog.

Fig 1.4: KUKA KMR platform.

Figure

Fig 1.5: KUKA KMP-1500.

Fig 1.6: Clearpath Husky.

The primary objective of this study is therefore to quantify the accuracy and repeatability of multiple mobile platforms operating in controlled conditions and to compare their relative performance. This evaluation provides essential baseline data for future deployment of these platforms with manipulator arms, enabling assessment of combined mobile manipulator accuracy for NDT applications.

The key contributions of this work are:

  1. A standardised, externally referenced experimental workflow for quantifying mobile platform base positioning accuracy both static and along segmented trajectories that is reproducible across heterogeneous commercial platforms and control stacks.

  2. A comparative characterisation of five commercial platforms under identical conditions, reporting the full error distribution (including the tail of poor placements) rather than a single flattered mean.

  3. A localisation capability cascade linking each platform's positioning accuracy and its very calibratability to its onboard localisation, and a framework that uses this to size the supplementary sensing required for NDE deployment.

The study characterises the mobile base as the precursor to a mobile manipulator; it does not claim to measure end effector or probe accuracy, which would additionally depend on the manipulator and end effector calibration.

References (46)