SliceBridge: context-consistent repair of corrupted slice intervals in T1-weighted MRI

Jiheng Li, Michael E. Kim, Trent Schwartz, Gaurav Rudravaram, Derek B. Archer, Timothy J. Hohman, the Alzheimer's Disease Neuroimaging Initiative, Lianrui Zuo, Bennett A. Landman

ABSTRACT

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.

Keywords: T1-weighted structural MRI; image restoration; flow matching

1. INTRODUCTION

T1-weighted structural magnetic resonance imaging (MRI) is widely used in morphometry, brain segmentation, and other neuroimaging analyses, all of which depend on the reliable depiction of anatomical structure and regional anatomical boundaries. Acquisition and reconstruction abnormalities, however, alter those boundaries and bias estimates of brain volume or cortical anatomy 1−3^{1-3}. Such abnormalities are not always distributed throughout the entire volume: a single axial slice or a short contiguous interval may appear inconsistent with its neighbors through abrupt changes in intensity, sharpness, noise, alignment, or anatomical appearance 4−6^{4-6}. We refer to this as localized slice corruption (Figure 1). This corruption often results from acquisition abnormalities, motion, hardware, or reconstruction effects, although the reconstructed image alone may not reveal the underlying cause 5,7^{5,7}. Although a corrupted interval typically occupies only a small portion of the volume, it may still disrupt downstream processing. Figure 1 shows a real example in which a corrupted interval coincides with localized fragmentation in a downstream whole-brain segmentation.

1^{1} Data used in preparation of this article were obtained from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database (adni.loni.usc.edu). As such, the investigators within the ADNI contributed to the design and implementation of ADNI and/or provided data but did not participate in analysis or writing of this report. A complete listing of ADNI investigators can be found at: http://adni.loni.usc.edu/wp-content/uploads/how_to_apply/ADNI_Acknowledgement_List.pdf

Figure

Figure 1. Real localized slice corruption spanning several adjacent slices in a T1-weighted volume. The corrupted slices (red) show local signal abnormalities and coincide with fragmentation in a downstream segmentation method (SLANT-TICV). Neighboring unaffected slices are shown in blue.

Localized slice corruption often comes with a trade-off: the affected interval cannot be trusted, but rejecting the entire scan would discard unaffected regions, while whole-volume correction would unnecessarily alter regions that remain usable⁴,⁸,⁹. Selective restoration confined to the corrupted region avoids both undesired outcomes. We therefore consider the setting in which a single axial slice or a contiguous axial interval of a T1-weighted volume has been identified as corrupted, either by manual quality control or by an automated slice-level detector. Because the corrupted content cannot be trusted, it is excluded from the conditioning input: the repair (restoration) is inferred only from the intact neighboring slices within the same volume, and all intact slices are left unchanged. Since the restoration replaces complete axial slices, it must satisfy two requirements. Each restored slice must be anatomically plausible in isolation, which we term in-plane (axial) reconstruction fidelity, and the restored slices together must form a coherent slice-to-slice progression within the interval and across its boundaries, which we term through-plane consistency.

Related work provides complementary precedents but not a direct solution. Prediction-based outlier replacement is established in diffusion MRI, where an unreliable slice can be replaced using an expectation inferred from other diffusion measurements¹⁰,¹¹. This approach relies on redundancy across diffusion measurements, directions, and shells, which is unavailable within a single T1-weighted volume. Structural MRI studies instead show that same-volume spatial context can support localized reconstruction⁶,¹²⁻¹⁴. Verschuur et al. interpolated identified motion-affected slices in neonatal T2-weighted MRI⁶, while Chai et al. restored missing through-plane content by inpainting masked rows in sagittal or coronal reformats, providing an indirect orthogonal-plane reconstruction formulation¹³. However, neither route is sufficient here. Interpolation satisfies through-plane consistency by construction but cannot synthesize anatomy that is not a blend of its neighbors, and the error grows with interval length; orthogonal-plane inpainting encourages smooth changes within each sagittal or coronal slice, but it recovers axial content only implicitly and does not directly model each complete axial slice or how the repaired slices change from one to the next. Together, these gaps motivate three questions. The first two questions follow from the repair requirements above: how direct reconstruction of complete axial slices compares with linear interpolation and with orthogonal-reformat inpainting, and whether coordinating the reconstruction of multiple slices improves through-plane consistency over reconstructing each slice independently. The third concerns downstream value: whether selective restoration reduces corruption-induced error in morphometric measurements.

We introduce SliceBridge to address these questions through direct axial reconstruction with interval-level coordination. Given a corrupted interval, SliceBridge reconstructs each complete axial slice using a shared 2D U-Net¹⁵ trained with rectified flow matching¹⁶, conditioned on the intact neighboring slices and on their positional information. In-plane plausibility alone, however, does not deliver through-plane consistency: independent stochastic trajectories can introduce abrupt changes between adjacent predictions¹⁷,¹⁸. SliceBridge therefore couples generation using interval-correlated initial noise, an interval-shared flow time during training, and synchronized sampling during inference. To isolate what this coupling contributes, we compare against an uncoupled-flow model matched in data, context, positional conditioning, and architecture but generating each slice independently. We then evaluate whether the resulting restoration reduces corruption-induced error in downstream morphometric measurements.