Manuscript Offprint

arXiv:2609.02210

Asymmetric Paired-Annotation Learning for Multi-Structure ULF Pediatric Brain MRI Segmentation

Ha-Hieu Pham, Dang P. M. Cao, Minh Hoang Pham, Khanh Nguyen Vo Ngoc, Thanh-Huy Nguyen, Ulas Bagci, Huy-Hieu Pham

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Ha-Hieu Pham¹*, Dang P.M. Cao¹,²*, Minh Hoang Pham³, Khanh Nguyen Vo Ngoc⁴, Thanh-Huy Nguyen⁵, Ulas Bagci⁶, and Huy-Hieu Pham¹,²,⁷†

¹ VinUni-Illinois Smart Health Center, VinUniversity, Hanoi, Vietnam ² College of Engineering & Computer Science, VinUniversity, Hanoi, Vietnam ³ Hanoi University of Science and Technology, Hanoi, Vietnam ⁴ University of Information Technology, VNU-HCM, Ho Chi Minh City, Vietnam ⁵ Carnegie Mellon University, Pittsburgh, PA, USA ⁶ Northwestern University, Evanston, IL, USA ⁷ Center for Innovations in Health Sciences, VinUniversity, Hanoi, Vietnam

Abstract. Portable ultra-low-field (ULF) MRI can expand access to pediatric neuroimaging, but segmentation at 0.064 T remains challenging because anatomical boundaries are weakly delineated, small structures may be only partially visible, and high-field references can be locally misregistered. The LISA 2026 Challenge provides two non-equivalent annotations reflecting different sources of anatomical evidence: a high-field-derived (HF) mask defining the scored target and a low-field-edited (LF) mask aligned with visible ULF anatomy. In this challenge report, we describe AURA, an nnU-Net-based asymmetric supervision strategy that treats these annotations as distinct observations rather than interchangeable ground truths. AURA anchors training to the HF mask and incorporates the LF mask through a bounded reliability gate based on label disagreement, boundaries, predictive uncertainty, class reliability, and training stage. On a 16-case development split, the HF-supervised baseline, AURA, and their ensemble achieved Dice scores of 0.7984, 0.7950, and 0.7988, respectively, while the ensemble achieved an HD95 of 1.8892 and an ASSD of 0.7855. These results provide a preliminary evaluation of AURA within the LISA 2026 Challenge and motivate further assessment on the hidden test set and external ULF cohorts. Our code and pre-trained models are available at https://github.com/minhdang050806/A-nnU-Net-based-asymmetric-supervision-strategy.

Keywords: Ultra-low-field MRI · Pediatric brain segmentation · Asymmetric supervision · Label uncertainty

  • Ha-Hieu Pham and Dang P. M. Cao contributed equally to this work. † Corresponding author: hieu.ph@vinuni.edu.vn

1 Introduction

Portable ultra-low-field (ULF) MRI offers a practical route to pediatric neuroimaging in settings where conventional high-field scanners are costly, inaccessible, or difficult to deploy. Recent work on low-field and portable MRI has emphasized its potential for point-of-care neuroimaging, bedside deployment, and improved access in resource-constrained environments [2,9,12,14]. This accessibility is clinically attractive, but it also introduces challenges for image analysis: at 0.064 T, brain MRI has lower signal-to-noise ratio, weaker tissue contrast, stronger partial-volume effects, and greater sensitivity to motion than high-field MRI [2,9,3]. These factors can make multi-structure segmentation difficult, particularly for small deep nuclei, hippocampal, and thin anatomical boundaries whose appearance may be only partially expressed in the low-field image [10]. The LISA 2026 segmentation task considers this setting by requiring segmentation of 11 structures from 0.064 T T2-weighted pediatric brain MRI: bilateral hippocampal, lateral ventricles, caudate nuclei, lentiform nuclei, and thalami, together with the corpus callosum [11]. Although U-Net-style volumetric segmentation and nnU-Net provide strong baselines for biomedical segmentation [13,4,5], the paired annotations provided in this task introduce an additional supervision-related consideration.

Each training image is released with two annotations that reflect different observation processes. The high-field-derived (HF) mask is obtained from high-field anatomy registered to the ULF image and defines the official target, but it may be locally affected by registration error. The low-field-edited (LF) mask is intended to reflect structures visible in the ULF acquisition, but it may omit or simplify anatomy that cannot be resolved confidently at low field strength. This setting is related to problems of label fusion, inter-observer variability, and noisy supervision in medical image analysis [16,6], while also introducing an asymmetry between the two annotations in terms of their role in scoring, anatomical visibility, and image alignment. Using only the LF annotation would move training away from the official target, whereas treating the two masks as uniformly reliable may not fully account for their different sources of information. We therefore explore an asymmetric formulation in which the HF mask remains the primary supervision target and the LF mask is incorporated as a conditional auxiliary signal.

Our method, AURA, implements this formulation through a bounded reliability gate. We use the name AURA to denote an asymmetric, uncertainty- and reliability-aware supervision strategy for the paired HF/LF annotation setting. Its intended use case is training with paired annotations while retaining an ULF-only deployment pathway. AURA therefore does not require a high-field image, an HF mask, or an LF mask at test time. The LF contribution is modulated using label disagreement, anatomical boundaries, predictive uncertainty, class-specific reliability, and training stage, with the aim of incorporating potentially complementary LF information while limiting its influence on the primary HF target. The segmentation backbone remains a 3D full-resolution nnU-Net [5]. A hard-voxel baseline is trained on the HF target with soft Dice and TopK cross-entropy, while AURA is initialized from this baseline and fine-tuned using asymmetric paired-label supervision. At inference, both branches receive only the ULF MRI and their probability maps are averaged before argmax prediction and per-class largest connected component filtering.

This report describes the approach developed for the LISA 2026 Challenge and evaluates it within the available development setting. First, we formulate the paired HF/LF annotations as asymmetric observations with different roles in scoring, image alignment, and anatomical visibility. Second, we describe a bounded, reliability-gated supervision strategy that incorporates LF edits while retaining the HF target as the primary supervision source and preserving an ULF-only deployment pathway. Third, we report a reproducible nnU-Net-compatible training, ensembling, and post-processing recipe with evaluation across overlap, surface-distance, and volume-bias metrics, following the recommendation that segmentation validation should combine region-, distance-, and volume-based criteria [15]. Since the model configuration and ensemble weighting were selected using the available development data, the reported results are intended as a challenge-cycle evaluation rather than evidence of independent generalization. The relatively small performance differences observed on the development setting further motivate cautious interpretation and evaluation on the hidden challenge test set.

References (15)