arXiv:2609.02222cs.ROSep 2026

Manuscript Offprint

arXiv:2609.02222

FOCUS: Foot Observation Confidence for Robust Humanoid Proprioceptive Odometry

Kaixin Feng, Angsong Li, Shaopeng Zhang, Enyu Li, Peiwen Lin, Chuang Wang, You Li, Haiyu Lan

Kaixin Feng¹, Angsong Li², Shaopeng Zhang², Enyu Li², Peiwen Lin², Chuang Wang², You Li¹, and Haiyu Lan²,†

¹Wuhan University

²AgiBot

Abstract—Foot forward kinematics (FK) is widely used to improve proprioceptive legged odometry by providing reliable velocity constraints during foot support. Existing contact-aided estimators generally rely on binary contact decisions to determine whether the FK measurements of an entire foot should be trusted. However, contact does not necessarily imply FK reliability. Dynamic locomotion often involves partial support, toe dragging, and foot slip, causing binary contact decisions to accumulate significant drift over long trajectories. To address this limitation, we propose FOCUS (Foot Observation Confidence from Unannotated Simulation), which predicts a continuous FK reliability weight for each foot instead of estimating binary foot contact. Rather than replacing the model-based estimator, the predicted reliability weights are used to blend FK velocity observations with IMU-propagated body velocity and to adapt the observation covariance of an extended Kalman filter (EKF), enabling smooth reliability-aware fusion without hard contact switching. The network is trained from automatically generated simulation signals using an FK-weighted velocity consistency loss with lightweight simulator-contact regularization, without manually annotated continuous FK-reliability labels. The deployed model relies only on IMU and joint kinematic measurements, making it suitable for hardware platforms with unreliable torque sensing. Experiments demonstrate that FOCUS reduces absolute trajectory error (ATE) by 83.7% on simulated walking episodes, preserves simulated dynamic-motion fidelity in motion scale and spectral energy, reduces ATE by 70.8% across 19 real walking segments, and reduces mean ATE by 42.7% across four real dynamic-motion routines.

Index Terms—Legged odometry, humanoid robot, proprioceptive odometry, state estimation, EKF, forward kinematics, contact reliability, Transformer

I. INTRODUCTION

Reliable proprioceptive odometry is essential for legged robots operating without external localization. A widely used approach is to fuse inertial measurements with foot forward kinematics (FK) in an extended Kalman filter (EKF) [1]–[3]. This contact-aided formulation is simple, interpretable, and real-time: when a foot is stationary with respect to the ground, the kinematic chain provides a strong constraint on body motion.

The difficulty is deciding when FK should be trusted. Existing systems typically infer binary contact from force, estimated torque, or learned classifiers and then gate the entire FK observation [4]–[6]. However, long walking sequences amplify contact errors, while dynamic motions introduce toe scraping, partial support, fast swings, and slip. Because FK requires a rigid, stationary-foot constraint, a contacting foot

Figure

Fig. 1. Motivation of FOCUS. Dynamic humanoid motion breaks binary contact gating: high torque or apparent contact does not necessarily imply reliable FK. FOCUS instead estimates continuous per-foot FK reliability weights for the left and right feet.

may still provide an unreliable observation, which binary gating cannot express.

FOCUS (Foot Observation Confidence from Unannotated Simulation), illustrated in Fig. 1, reformulates contact handling as continuous FK reliability estimation. It predicts continuous per-foot weights that blend FK velocity observations with IMU-propagated body velocity and modulate the EKF observation covariance, while preserving the model-based FK-EKF structure.

The reliability estimator is a lightweight causal Transformer that uses a short history of IMU, joint position, and joint velocity measurements. It is trained from automatically generated simulation signals without manually annotated continuous reliability labels. The deployed model is sensor-only and does not use torque input, reducing sensitivity to actuator-current-based torque estimates.

Experiments show that FOCUS reduces mean ATE by 83.7% in simulated walking, by 70.8% across 19 real walking segments, and by 42.7% across four real dynamic-motion routines.

  1. We construct a simulation data-collection pipeline for FK reliability learning. A humanoid motion-tracking control policy is trained in Isaac Lab and then replayed over diverse motion clips, producing executed robot motions with domain randomization, tracking error, and contact variation for training.

  2. We train a causal Transformer to estimate two continuous per-foot FK reliability weights in [0, 1] from sensor-only proprioception. The continuous reliability output reduces sim-to-real brittleness compared with hard contact labels, and the FK-weighted velocity consistency objective removes the need for manually annotated continuous FK-reliability labels.

  3. We evaluate the learned estimator on simulation, a 19-segment real walking set collected from five A3 Ultra humanoid units, and 18 real dynamic-motion sequences across four dance types, against threshold-based and representative proprioceptive odometry baselines.

References (25)