arXiv:2609.02306cs.ROSep 2026

Manuscript Offprint

arXiv:2609.02306

Contact-Constrained Lower-Limb Joint-Offset Calibration for Humanoid Robots

Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Chengyuan Luo, Enyu Li, Peiwen Lin, Chuang Wang

Kaixiang Lu, Haiyu Lan*, Chunxiao Qiao, You Li, Chengyuan Luo, Enyu Li, Peiwen Lin, Chuang Wang

Abstract—Accurate joint encoder offsets are essential for kinematic consistency in humanoid lower limbs, yet existing calibration methods typically require external motion-capture systems or fiducial targets. We present a self-contained calibration framework exploiting only onboard joint encoders and a pelvis-mounted IMU during static double-support contact. The inter-foot transform from forward kinematics must stay constant when both feet are fixed; minimizing its posture-dependent dispersion yields a nonlinear least-squares problem over the 12-dimensional offset vector. A Hessian eigenstructure analysis shows that parallel pitch axes induce a rotational coupling. Orientation residuals then observe only the pitch-offset sum, while translation and posture diversity set the remaining numerical observability. For the A3 pitch→roll→yaw ordering, hip-roll and hip-yaw excitation reduce hip-pitch coupling. A standing-posture knee prior then anchors the remaining weak pitch-chain decomposition. Simulation and real-machine injection tests show consistent recovery, and on held-out recordings calibration reduces foot-height RMS residuals from 4.26 to 2.20 mm on A3 and from 8.03 to 1.43 mm on A2. An independent LiDAR-inertial reference checks the pitch-coupled channel. Removing an injected pitch offset moves the leg-odometry vertical drift back toward the LiDAR trajectory. A few static double-support stances thus provide contact-consistent corrections for well-excited directions. Individual offsets in the weak pitch chain remain prior-dependent.

I. INTRODUCTION

Humanoid robots depend on accurate kinematic models for locomotion, whole-body control, and contact planning [1], [2]. Joint encoder offsets, the persistent biases between encoder and true mechanical zero, accumulate along serial chains and cause foot-placement errors and degraded balance [3]. Even sub-degree per-joint offsets can generate centimeter-level distal errors at the foot sole.

Classical calibration identifies kinematic parameters by minimizing discrepancies between model predictions and external measurements from laser trackers, motion-

Figure

Fig. 1. Calibration principle. Upright and squat postures share the same fixed-foot transform CkC_k; the pelvis IMU provides gravity gg.

capture systems, or fiducial targets [3], [4]. Such setups are impractical for repeated in-field recalibration.

A vision-based alternative observes onboard fiducial markers with onboard cameras [5], [6]. For the legs, however, the feet rarely enter the head-camera field of view during normal stances, making foot markers unreliable. This motivates a calibration signal that needs no external view of the limb.

The key physical constraint available to legged robots is contact: during stable double support, both feet remain fixed relative to the ground, and the inter-foot transform must be constant across all postures. If joint offsets are incorrect, this transform varies with posture, and minimizing its dispersion yields offset estimates. This idea has appeared implicitly in legged state estimation [7]–[9], and Liu and Tang [10] applied double-support constraints to offline humanoid calibration on the NAO platform. What remains less explicit is how the resulting batch optimization is conditioned by lower-limb joint ordering, especially under the parallel pitch axes common in humanoid legs.

The AGIBOT A2 uses a roll-yaw-pitch proximal ordering. The AGIBOT A3 uses a pitch-roll-yaw ordering.

Yamane [11] demonstrated practical kinematic calibration for humanoid robots using joint encoders, an IMU, and flat-foot contact constraints. However, the inherent coupling among the parallel pitch axes of hip-

Figure

Fig. 2. Calibration pipeline: collect multi-stance double-support data, form contact and flat-ground residuals, and alternate contact-mean updates with offset optimization. P/R/Y/K denote pitch/roll/yaw/knee; red, blue, and green boxes encode pitch, roll, and yaw, and dashed outlines mark pitch coupling.

pitch, knee, and ankle-pitch was not formally characterized. Because consecutive pitch joints rotate about aligned Y-axes, their offsets produce collinear rotational Jacobian columns, so only their sum is observable from orientation. We provide a formal Hessian-eigenvector characterization of this coupling and develop decoupling strategies tailored to different kinematic orderings.

The contributions are:

  1. A self-contained lower-limb calibration framework combining inter-foot contact consistency, IMU-aided flat-ground constraints, and Tikhonov regularization with mechanical priors, requiring only onboard joint encoders and a pelvis IMU.

  2. A formal Hessian-based analysis of pitch-axis coupling. The analysis separates information in the data from curvature added by regularization and mechanical priors.

  3. Validation on A3 simulation and on both real platforms. A same-geometry MuJoCo study isolates the effect of joint ordering. External LiDAR and registered motion-capture tests check the pitch-vertical channel and inter-foot orientation, and a free-standing MuJoCo deployment tests closed-loop locomotion under persistent offsets.

References (29)