Abstract—Palm-vein biometrics are increasingly used for secure, contactless authentication. Yet real-world deployment exposes them to surface noise (sweat, dirt), illumination and motion variation, and temperature-driven changes in vascular visibility, which remain underexplored for lack of data captured under such conditions. To study these effects, we introduce the Columbia University Palm-vein (CUP) dataset, to our knowledge the first public video-based palm-vein dataset. CUP records every palm under four surface conditions (a clean baseline, warm, wet, and dirty) and pairs each subject with physiological and demographic metadata. On it we benchmark twenty-one recognizers spanning static, video, and multi-frame aggregation architectures. Models that verify reliably on clean palms lose most of their accuracy on dirty ones, and the mean equal error rate (EER) roughly quadruples. We recover much of that robustness along both axes of the capture. Temporally, a consensus over the few frames the sensor already returns cancels transient corruption; spatially, a test-time matcher that adds no learned parameters fuses the global cosine with a saliency-steered region-level optimal transport that routes the comparison around corrupted regions. The full design leads on every surface of CUP in EER, TAR@FAR=0.01, and Rank-1, at 4.3M parameters and 3.1 GFLOPs, a fraction of the video models' cost. Attached to four frozen state-of-the-art backbones it cuts their mean EER by 29–37% without retraining, and on four public single-image datasets the regional matching alone still helps. A preliminary audit across ten demographic and physiological traits finds two warm-condition gaps, along body water and gender, that survive multiple-comparison correction. CUP will be released for non-commercial research use at https://github.com/MobileX-CU/CUP_v1 upon publication.

Index Terms—Palm-vein recognition, biometrics, video-based authentication, optimal transport, robustness, dataset, fairness.

I. INTRODUCTION

Palm-vein biometrics are attracting growing interest, offering unique advantages over conventional modalities such as fingerprints or the iris. Vein patterns are internal and visible only under near-infrared (NIR) illumination, making them difficult to observe or capture covertly [1]–[4]. The contactless capture is also hygienic, boosting user acceptance in the post-pandemic era. Beyond security and hygiene, the technology offers competitive accuracy with inexpensive hardware [5]. The vascular pattern also carries high biological entropy: it stays unique even for identical twins, where face recognition struggles. These advantages have spurred rapid commercial adoption by industry leaders such as Amazon and Alipay.

Figure

Fig. 1. Surface Degradation in CUP. Columns are a clean baseline and the three degrading surface conditions (warm, wet, and dirty) that corrupt the near-infrared vein signal; rows are different subjects. Every palm is re-recorded under all four conditions.

Despite this success, the technology's performance under non-ideal, real-world conditions is not well understood. The non-planar topography of the palm makes static features sensitive to acquisition artifacts: pose variation, shadows, and surface contaminants like sweat or dirt (Fig. 1). These artifacts degrade matching performance. While industry solutions claim high accuracy, their proprietary data hinders independent validation. On the other hand, public datasets have been developing fast, from contact plates [6] and controlled contactless capture [7] to multi-wavelength imaging [8], two-session collection [9], and large-scale, weakly cooperative capture [10]. However, even the least controlled of them release only still images of clean palms, leaving the surface conditions of everyday use untested.

We built CUP to supply exactly these conditions; to our knowledge it is the first public video-based palm-vein dataset. The format is video for two reasons. A contactless capture natively returns a short sequence as the user positions the hand

This work was performed at the Department of Computer Science, Columbia University, New York, NY 10027 USA. X. Yan, X. Zhou, and S. Stolfo are with the Department of Computer Science, Columbia University, New York, NY 10027 USA. K. Liu is with Princeton University, Princeton, NJ 08544 USA. C. Zhang is with Stanford University, Stanford, CA 94305 USA. A. Venkatesh contributed to this work while at Columbia University and is currently with Amazon.com Services LLC, USA. Corresponding author: Salvatore Stolfo (e-mail: sal@cs.columbia.edu).

over the sensor, so the frames come for free. They also carry complementary identity evidence, which has proved valuable for face recognition under noisy, less controlled capture [11], [12]. The dataset provides 5,049 curated two-second NIR clips from 109 subjects, recorded under a protocol that mirrors everyday use and released for non-commercial research use. CUP loosens control along two further axes. Each palm is presented with the natural pose and distance variation of routine interaction and is re-recorded under four surface conditions: a clean baseline, warm, wet, and dirty. Every subject is paired with demographic and physiological metadata (§III). We then use CUP to quantify how everyday degradation affects recognition. The drop is severe and universal: recognizers that verify reliably on clean palms lose most of their accuracy on dirty ones. The twenty-one recognizers we benchmark span vascular-specific pipelines, generic image backbones, end-to-end video models, and multi-frame aggregation. Across all of them, the mean equal error rate (EER) roughly quadruples, from 4.11% to 17.35%. Training on degraded data and averaging over frames help only partially: on dirty palms every recognizer stays far above its own clean-palm floor (§III-D).

Given degradation of this severity, the global embedding is itself corrupted. Water reflections or surface contaminants can wipe out whole regions of the vein signal at once, and the damage pools into the single vector being compared. We instead compare palms with a matcher that operates along both dimensions of a video capture, space and time. Person re-identification and face recognition survive occlusion the same way: the reliable parts of the input decide the match [13]–[16]. Spatially, we compare palms region by region, so that the regions that survive the degradation can decide the match. The comparison runs as an entropic optimal transport, which shifts matching weight off corrupted regions. A saliency prior then spends that weight on the regions that best identify each gallery. We keep the global embedding alongside, because some probes fail the other way: their local patches are misleading while the overall pattern still matches. Fusing the two views lets each recover the probes the other loses. Temporally, a consensus over the frames of a clip cancels transient corruptions and recovers the stable vein signal beneath. The only training we add is a light consensus objective that makes each frame reliable on its own, leaving the architecture untouched.

Extensive experiments support this design. On CUP it leads on every surface condition and every metric, with the widest margin on the hardest, dirty condition. Because the matcher adds no trainable parameters, the gain is not tied to our encoder. Attached to four frozen CNN and transformer backbones, it improves every one on every surface and metric without retraining; it also generalizes to four public single-image datasets [7], [9], [10], [17]. Under a subject-disjoint protocol with no shared subjects, the ordering holds and the margin widens (§V-B). We further probe where the value of video lies. A few frames sampled evenly across the two-second capture already realize the full multi-frame gain, whereas consecutive frames are largely redundant. The benefit thus comes from covering the capture window rather than from a high frame rate, and it adds no acquisition cost.

Finally, we use CUP's metadata to study systematic per-

formance differences across user groups. During collection we observed that vein visibility varies across participants, so CUP records per-subject demographic (e.g., age, gender) and physiological (e.g., BMI, body fat) measurements. We audit recognition accuracy across ten such traits. The audit finds two warm-condition differences, along body water and gender, that survive multiple-comparison correction; they mark where a larger study should look.

In summary, this paper makes three contributions:

  • Dataset and benchmark. We release CUP, to our knowledge the first public video-based palm-vein dataset with four surface conditions and paired metadata. With it we benchmark twenty-one recognizers under a matched protocol, quantifying this drop and tracing it to pooled embeddings.

  • A matcher built on what the benchmark reveals. Guided by the failure mode CUP exposes, we propose a dual-view encoder with a region-level optimal-transport matcher that adds no learned parameters. The full method restores accuracy on CUP, and the matcher alone carries its gain to other backbones and public datasets without retraining.

  • A dataset-enabled fairness signal. Enabled by CUP's per-subject metadata, we conduct a preliminary audit of recognition accuracy across ten demographic and physiological traits, which we report as a preliminary signal rather than a characterization of palm-vein fairness.

References (73)