arXiv:2609.02854cs.CVSep 2026

Manuscript Offprint

arXiv:2609.02854

MuyBridge: Mobile Human Center-of-Mass Estimation from Monocular Video via Sparse Fusion

Aidan Bradshaw, Marco Giordano, David Rode, Andreas Habersack, Elif Basokur, Annika Kruse, Markus Tilp, Michele Magno, Peter Wolf, Luca Benini, Christoph Leitner

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

The 3D center of mass (CoM) is a primary quantity in the biomechanical analysis of sport, rehabilitation, and clinical movement, yet existing 3D pose tracking, mesh recovery, and multi-view triangulation methods either optimize 3D keypoint accuracy without anatomical constraints or carry compute and capture infrastructure too heavy to deploy where CoM tracking is most useful. As a result, the metric CoM remains difficult for coaches and movement analysts to measure from a single camera where athletes train and compete. In this work, we introduce MuyBridge, an on-device system that estimates the athlete's segmental center of mass trajectory from a single phone camera video stream. MuyBridge couples a compact 2D pose network and a distilled single-step monocular depth network through an analytic metric fusion that uses anatomical and physical priors to anchor the metric CoM, requiring no 3D or task-specific supervision. Evaluated on the athletic movements of AthletePose3D (running, track and field, and figure skating), MuyBridge achieves 33–41 mm vertical CoM error and 2.3–6.6% absolute-relative range error (AbsRel) under a one-time calibration, and produces CoM estimates at the 63 FPS pose-estimation rate using asynchronous 2.86 Hz depth updates on iPhone 15. Code is available at: https://github.com/Abradshaw1/Muybridge.

1. Introduction

The whole-body center of mass (CoM) is a widely used quantity in segmental biomechanics for analyzing balance, acceleration, and landing in athletic performance [2, 26, 30, 50]. Estimating it, however, commonly requires metric body-segment positions together with segment lengths, mass fractions, and segment-specific centers of mass, obtained from marker-based motion capture [11, 14, 30], force plates [1, 13, 41], or wearable inertial sensing [24, 43]. This often confines athletes to laboratories and dedicated capture facilities rather than the fields, arenas, and training envi-

ronments where they normally train, making it difficult to measure their natural movement during competition.

Computer vision offers a way to measure similar movements with substantially less equipment. Two-dimensional pose estimators recover image-space joint locations [22, 44, 52], 2D-to-3D lifting methods recover 3D joint configurations [16, 31, 56], mesh-recovery methods estimate body pose and shape [12, 20, 33], and monocular depth models estimate scene geometry [15, 36, 37]. Although useful, these methods are generally optimized for keypoint, pose, surface, or depth accuracy and do not directly recover anatomical quantities. A smaller body of work incorporates biomechanical structure through musculoskeletal models [46, 51] or mass and contact constraints [45], but often relies on computationally heavy 3D body representations [19, 23, 51] or calibrated multi-view capture and cloud processing [46], limiting their use and practicality during routine athletic measurement. This leaves segmental CoM monitoring on deployable platforms largely unexplored.

We introduce MuyBridge, a monocular system for estimating metric segmental CoM from phone video. MuyBridge combines a compact pose network that identifies image-space anatomical keypoints defining the athlete's body segments with monocular depth sampled at these locations to capture relative range and track camera-to-athlete motion. The system then uses an analytic fusion of the pose and depth predictions with stature-scaled anthropometric constraints to recover metric range, while a one-time scene calibration supplies the ground-plane geometry required by complementary physical cues. The resulting fused range places the keypoints as metric 3D segment endpoints. MuyBridge maps these endpoints to segment geometries, mass fractions, and longitudinal CoM locations using stature-scaled, sex-specific de Leva parameters [9], then computes whole-body CoM as a mass-weighted sum of the resulting segment centers.

We evaluate MuyBridge on AthletePose3D [54] across running, track and field, and figure skating. Across these motion regimes, MuyBridge achieves 33–41 mm vertical

CoM error and 2.3–6.6% absolute-relative range error (AbsRel). We evaluate aggregate performance and characterize how viewpoint, motion phase, and individual range cues affect monocular CoM recovery. On an iPhone 15, the pose network runs at 63 FPS while asynchronous depth updates at 2.86 Hz support CoM estimation at the pose rate.

  • MuyBridge, a deployable single-camera method for metric segmental CoM estimation that combines image-space pose, subject-specific anthropometry, sparse monocular depth, and geometric range constraints without task-specific 3D human-pose or CoM supervision.

  • An evaluation across cyclic, rotational, and ballistic athletic motions that characterizes where MuyBridge performs well and where camera-to-athlete range recovery becomes the dominant source of error, including the effects of viewpoint, motion phase, and individual range cues.

  • A hardware-aware mobile implementation that compresses and quantizes the pose and depth networks, executes them asynchronously, and profiles latency, throughput, memory, and energy on an iPhone 15.

References (52)