Manuscript Offprint
arXiv:2609.00300TRUST: Threshold-Recalibrated Uncertainty-Safe Training for Certified Dismissal in Breast Cancer Screening
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Abstract
Reducing the review of clearly cancer-negative screening mammograms could lower radiologist workload without compromising cancer detection. We propose a closed-loop threshold-aware training strategy in which the dismissal threshold is recalculated during training and used to penalize cancer-positive images that approach the dismissal region. We evaluated the method on NLBS and RSNA using five controlled training configurations, with case-level assessment based on a one-sided 99% Clopper–Pearson upper bound for cancer prevalence among dismissed cases. The proposed model achieved the highest case-level dismissal rates at both 98% and 95% recall targets. On NLBS, dismissal reached 19.74% and 21.70%, while the cross-entropy baseline did not meet either recall target. On RSNA, dismissal improved from 7.04% to 14.31% and from 13.49% to 19.69%. In external RSNA→NLBS evaluation, the proposed model achieved dismissal rates of 12.95% and 19.87% at the 98% and 95% recall targets, respectively. These results support closed-loop threshold-aware training for high-recall selective dismissal.
Keywords: safe dismissal, breast cancer screening, selective classification, statistical risk control, mammography
1 Introduction
Every screening mammogram is assigned a Breast Imaging Reporting and Data System (BI-RADS) category [4]. Most examinations are classified as BI-RADS 1 or 2, and these patients return for routine screening. In one screening cohort, 7.5% of examinations were classified as BI-RADS 0, with higher rates at first screening than at subsequent screening examinations [5]. This evaluation commonly includes additional mammographic views and targeted breast ultrasound [6]. Based on the additional findings, the examination may then be classified as BI-RADS 1 or 2, BI-RADS 3 requiring short-interval follow-up, or BI-RADS 4 or 5 for which biopsy is recommended [7]. Although biopsy provides the definitive diagnosis when required, most recalled findings and a substantial proportion of biopsied findings are ultimately benign [8]. These additional steps increase radiologist workload and imaging use while also contributing to patient anxiety and healthcare costs.
The economic burden of breast cancer screening extends beyond the initial mammographic examination. A recent Canadian health-system analysis estimated the cost of a digital screening mammogram at CAD1.44 million in screening costs and an additional CAD2.79 million in screening costs and CAD$241,000 in recall-related diagnostic costs per 1,000 women. These figures illustrate the substantial cumulative resource use associated with population-scale mammography programs.
At the same time, the value of screening cannot be assessed from imaging costs alone. Earlier cancer detection can reduce treatment expenditure by shifting diagnosis toward less advanced disease. In the same Canadian analysis, breast cancer treatment costs ranged from approximately CAD500,000 for some stage IV disease presentations, and increased screening intensity was associated with lower overall treatment costs [9]. In a sensitivity analysis in which the recall rate was reduced toward the Canadian target of 5%, biennial screening from ages 40 to 74 was associated with approximately CAD$102,000 in health-system savings per 1,000 women compared with biennial screening from ages 50 to 74. These findings highlight the importance of reducing unnecessary downstream screening activity without compromising cancer detection, providing an economic as well as clinical motivation for AI-based approaches that can reliably identify examinations unlikely to require further review.
The growing workload associated with screening mammography has produced an increased interest in using artificial intelligence to reduce the number of examinations that require manual radiologist review. Large retrospective studies have reported deep learning performance comparable to that of individual radiologists across screening populations [10, 11]. More recently, the randomized MASAI trial demonstrated that AI-supported triage can be integrated into clinical screening workflows and reduce radiologist screen-reading workload by 44% while maintaining the cancer detection rate [12]. Follow-up analyses also reported improved screening performance and a non-inferior interval cancer rate compared with standard double reading [13, 14]. These findings provide evidence that AI can reduce screening workload while maintaining high cancer detection performance.
However, the safety demonstrated in these studies is based on observed performance within specific populations, workflows, and operating thresholds. This differs from a model-level statistical guarantee that can be independently evaluated, audited, and recalculated when the model is applied to a new setting. Conventional measures such as AUROC, sensitivity, and specificity describe overall discrimination, but they do not directly quantify how many examinations can be removed from manual review while controlling the risk of cancer among those dismissed.
This study therefore focuses on certified dismissal rather than automated diagnosis. The aim is not to replace radiologist judgment or to assume that false-negative cases can be eliminated completely. Instead, we investigate what proportion of screening examinations can be dismissed from manual review while maintaining a finite-sample statistical upper bound on the cancer rate within the dismissed group. Our framework addresses this objective using an exact binomial confidence procedure to quantify the statistical uncertainty in the cancer rate among dismissed cases, as described in Section 3. Existing selective-classification methods commonly determine an accept/reject threshold after classifier training or jointly learn prediction and selection functions [15, 16]. Related risk-control approaches also typically calibrate a risk-controlling parameter after model training is complete [17, 18].
Our approach differs by incorporating the dismissal criterion directly into training. We introduce a closed-loop, certificate-aware training objective in which the dismissal threshold is repeatedly updated during optimization and used to guide the classifier away from unsafe dismissal of cancer-positive examinations. In contrast to conventional post-hoc thresholding, the operating criterion therefore becomes part of the learning process itself. Final safe-dismissal performance is evaluated using an independently derived statistical certificate.
This study makes three main contributions. First, we introduce a closed-loop training objective that dynamically couples dismissal-threshold estimation with model optimization. Second, we use a controlled ablation study to distinguish the effect of dynamic threshold updating from the underlying classification losses and from a fixed-threshold alternative. Third, we evaluate the method on two independent mammography datasets using internal and cross-institutional external validation, with formally certified case-level dismissal and complementary image-level analysis.
2 Related Work
2.1 Deep learning for mammography screening
Large-scale deep learning systems have shown strong performance in breast cancer screening. Some studies have reported performance comparable to radiologists in retrospective evaluations [10, 19], while others have evaluated AI as an independent or integrated reader within population-based screening workflows [20, 21]. Prospective studies have also demonstrated that AI can be incorporated into clinical screening workflows to support cancer detection while reducing radiologist workload [12, 13, 14]. These studies have primarily evaluated AI using conventional measures such as AUROC, sensitivity, and specificity, together with measures of workload reduction.
More directly related to AI-based rule-out, Bernstein et al. proposed a statistical framework for selecting rule-out thresholds in screening mammography by examining the trade-off between caseload reduction and the risk of missed cancers [22]. Their analysis provides an important framework for evaluating the consequences of different rule-out thresholds. However, the thresholds are evaluated using scores from an already trained model and do not influence the model training process itself. This distinction is important for the present study, where the dismissal criterion is incorporated directly into the model optimization stage rather than being considered only after model training.
Domain-specific pre-training has also been explored to improve mammography representation learning and downstream performance. Mammo-CLIP, for example, uses vision-language pre-training on mammography data to support downstream classification tasks [23]. We use its pre-trained image encoder as the common backbone across all configurations in this study.
2.2 Selective classification and conformal risk control
Selective classification allows a model to abstain when its prediction is not sufficiently reliable. Geifman and El-Yaniv extended this idea to deep neural networks using confidence-based thresholding with finite-sample risk control [15]. They later introduced SelectiveNet, which jointly learns the prediction and selection functions within a single architecture [16]. Unlike these approaches, our method does not introduce a separate selection head. Instead, the dismissal boundary is used directly to guide optimization of the classifier itself.
Conformal prediction and conformal risk control provide related approaches for controlling uncertainty and predictive risk under exchangeability assumptions [24, 18, 17]. More recently, Yeh et al. introduced Conformal Risk Training, an end-to-end framework that incorporates conformal risk control into model training by differentiating through the risk-control procedure [25]. This work demonstrates the value of allowing a statistical risk criterion to influence model optimization rather than applying it only after training.
Our approach is related in motivation but focuses specifically on safe dismissal in breast cancer screening. Rather than applying risk control only after training, we incorporate a dynamically updated dismissal criterion into the training process so that the classifier is optimized for high-recall dismissal. Final case-level dismissal is then evaluated using an independent statistical certification procedure described in Section 3.
2.3 Calibration under class imbalance
Strong discriminative performance does not necessarily imply well-calibrated probability estimates. Modern neural networks can be poorly calibrated and are often overconfident in their predictions [26]. This issue is particularly relevant in breast cancer screening, where class imbalance can affect both model optimization and the reliability of predicted scores.
Focal loss was originally introduced to reduce the influence of easily classified examples in highly imbalanced detection tasks [27]. Later studies showed that, under certain conditions, it can also improve calibration compared with standard cross-entropy [28]. Brier-based objectives provide another approach by directly penalizing the squared difference between predicted probabilities and observed labels, and they have also been used as training objectives in medical imaging [29]. These methods were therefore included in our ablation study to examine whether improvements in calibration or class-imbalance handling also translate into better safe-dismissal performance.
2.4 Domain shift and external validation
Medical imaging models do not always generalize well across institutions, scanner types, and acquisition protocols. In some cases, model performance can be influenced by site-specific characteristics that are unrelated to the underlying disease [30]. Similar problems have been reported in mammography, where differences in imaging systems and acquisition conditions can reduce performance across datasets and institutions [31]. Recent cross-dataset work has also shown that dataset-specific patterns can remain detectable even after consistent pre-processing, and that adding external abnormal-enriched data does not necessarily improve performance on the target screening population [32].
Most studies of domain shift focus on changes in conventional performance measures such as AUROC. In this study, we also examine how safe-dismissal performance changes when the model is evaluated on data from an independent institution. This allows us to assess whether the benefit of certificate-aware training is maintained under cross-institutional domain shift.
3 Materials and Methods
3.1 Datasets
NLBS. The Newfoundland and Labrador Breast-Screening (NLBS) dataset was obtained from the provincial breast screening program of Newfoundland and Labrador Health Services. It consists of anonymized full-field digital mammograms stored in DICOM format. The published dataset includes 26,988 images from 5,997 screening cases, of which 149 cases were cancer-positive [33, 34].
The 149 cancer-positive cases contain 652 images across both breasts and all available views. Since cancer was usually present in only one breast, 337 images from the positive cases were assigned a positive image-level label. Images from the unaffected contralateral breast in the same cases were labeled negative. Mammograms were acquired using GE Senograph Essential full-field digital mammography systems manufactured between 2008 and 2010.
Cancer-positive cases were confirmed through further diagnostic procedures and laboratory analysis. Cases initially considered suspicious during screening but later shown to be nonmalignant were classified as false positive based on diagnostic imaging and/or laboratory findings. Normal cases were considered cancer-free when no interval cancer was identified during at least two years of follow-up.
RSNA. We used the publicly available training partition of the RSNA Screening Mammography Breast Cancer Detection Challenge dataset [35]. The dataset includes screening examinations collected at Emory Healthcare in the United States and BreastScreen Victoria in Australia. The training partition contains 11,913 examinations, with one examination per participant, and was enriched to approximately 4% cancer prevalence [35]. After preprocessing, the cohort used in this study contained 54,706 images from 11,913 examinations, including 486 cancer-positive examinations, corresponding to a case-level prevalence of 4.1%. In total, 1,158 images were associated with cancer-positive breasts.
Screen-detected cancer was defined as an abnormal screening examination followed by pathological confirmation of malignancy through biopsy or surgical excision. Negative examinations included those confirmed as negative or benign through follow-up, benign biopsy, or diagnostic assessment [35]. Cancer labels were provided at the breast level rather than independently for each image.
For comparison with NLBS, the primary RSNA analysis was performed at the examination level, with patient_id defining the case. An examination was considered cancer-positive if either breast was labeled cancer-positive.
3.2 Preprocessing
Both datasets were processed with the same DICOM-to-PNG pipeline to keep preprocessing consistent across the NLBS and RSNA datasets. The modality LUT and, when available, the VOI LUT were applied to the original DICOM pixel data [36]. MONOCHROME1 images were inverted so that breast tissue appeared brighter than the background. Each image was then min-max normalized to [0, 1]. This normalization was used only during the initial segmentation and cropping stage. The image intensity range was recalculated later in the model data loader.
Right-breast images were horizontally mirrored so that all images had a consistent orientation. Image cropping used a low threshold based on the median intensity along the image border. Holes inside the breast mask were filled, followed by morphological closing with a 9 × 9 kernel. Each image was cropped to the breast bounding box with a 10% margin. Pixels outside the breast mask were set to zero, and the resulting grayscale images were saved as 16-bit PNG files.
Before being passed to the network, each cropped PNG image was resized to pixels using linear interpolation, following the input size used in Mammo-CLIP [23]. The resized image was min-max normalized to [0,1]. During training, data augmentation included random rotations of up to , isotropic scaling between 0.9 and 1.1, and translations of up to 5% of the image dimensions. Brightness was varied by , and contrast was scaled between 0.90 and 1.10. Pixel values were clipped to [0,1] after augmentation.
The single-channel image was then replicated across three channels and standardized using the channel-wise mean and standard deviation of the released Mammo-CLIP checkpoint [23]. Calibration and test images were processed without random augmentation and underwent only resizing, min-max normalization, channel replication, and Mammo-CLIP standardization.
3.3 Model architecture
We used EfficientNet-B5 as the image encoder [37], initialized with the pre-trained Mammo-CLIP weights [23]. The encoder was kept frozen during training. Only the classification head was trained. This head consisted of LayerNorm, dropout with a probability of 0.3, and a single linear output unit. A sigmoid function was applied to the final output to obtain a score .
Keeping the encoder fixed allowed us to compare the different training objectives without changing the underlying image representation. Therefore, any differences between configurations were mainly due to the loss function and optimization of the classification head. The sigmoid outputs were treated as model scores rather than calibrated estimates of cancer probability, since balanced minibatch sampling changed the class distribution seen during training.
3.4 Case-level score and label definitions
Let represent the set of images belonging to case c. The case-level prediction score was defined as the maximum score among all images in that case:
where is the sigmoid output for image i. The case-level label was defined in the same way:
where is the image-level cancer label. A case was therefore considered cancer-positive if at least one of its images had a positive label.
Maximum aggregation was chosen as a conservative examination-level rule because a case should remain for radiologist review if any constituent image receives a high cancer score. Consequently, a case is dismissed only when all of its images fall below the operating threshold.
3.5 Certification unit and the independence assumption
The Clopper–Pearson bound in Equation (5) is an exact binomial confidence bound. In our setting, this requires each observation used for certification to contribute one independent binary outcome: whether a dismissed case contains cancer or not [38]. Multiple images from the same screening examination cannot be treated as separate independent observations because they come from the same patient and share acquisition-related characteristics. Treating these images as independent would artificially increase the sample size used for certification and could produce an overly narrow confidence bound.
For this reason, formal certification is performed only at the case level. Image scores are first combined using the maximum-aggregation rule in Section 3.4, so that each case contributes a single score and a single binary outcome to the Clopper–Pearson calculation. The resulting confidence bound therefore applies to the cancer rate among dismissed cases, not among individual dismissed images.
Image-level dismissal results are reported only as a secondary descriptive analysis. They are used to show how the model behaves at the individual-image level, but no Clopper–Pearson confidence bound or formal certification is assigned to those results. Throughout this paper, the statistical guarantee refers only to the case-level analysis.
3.6 Five-fold cross-validation and calibration splits
All five ablation configurations described in Section 3.10 were trained using the same five-fold cross-validation scheme. Splitting was performed at the case level using StratifiedGroupKFold, with stratification based on case-level cancer status and grouping by case identifier. This ensured that all images belonging to the same case remained in the same fold. Fold assignments were generated using a fixed random seed and reused for every configuration so that all models were compared under identical data splits.
For each fold, one fifth of the dataset (20%) was reserved as the outer test partition. The remaining 80% formed the development data and was divided at the case level, with stratification by cancer status, into 70% of the full dataset for model fitting and 10% for training calibration. The fitting subset was used for gradient updates, while the training-calibration subset was used to recalculate the provisional threshold during training, as described in Section 3.8. This threshold served only as a training-time optimization signal for the closed-loop loss and was not used as the final reported operating threshold. Thus, in each fold, 70% of the cases were used for fitting, 10% for training calibration, and 20% for outer testing.
All configurations were trained for a fixed 20 epochs. No early stopping or validation-based checkpoint selection was used, and the final-epoch checkpoint was used for inference in every configuration. This kept the training procedure identical across the ablation study and avoided differences caused by model or epoch selection.
After training each fold, predictions were generated for its outer test partition. Repeating this process across all five folds produced one out-of-fold prediction for every case in the dataset. Each out-of-fold prediction was therefore generated by a model for which that case had not been used for model fitting or training-time threshold calculation. The five outer-test prediction sets were then pooled to form a complete cross-validated prediction set covering the full dataset. Thus, every prediction included in the subsequent threshold-search and evaluation analyses was obtained out of fold, before the final search/evaluation split was created.
The final operating-threshold search and statistical evaluation were performed only after all out-of-fold predictions had been generated and pooled. The pooled predictions were then divided at the case level, with stratification by cancer status, into a 20% threshold-search subset and a separate 80% evaluation subset using a fixed random seed. This downstream split was separate from the training-calibration subset used during model optimization and did not alter or regenerate any model predictions. The 20% subset was used only to determine the operating thresholds for the 98% and 95% recall targets. The selected thresholds were then fixed and applied once to the independent 80% evaluation subset. No labels or outcomes from the evaluation subset were used to select or adjust the thresholds.
3.7 Threshold certification and evaluation
Threshold selection and final evaluation were performed after completion of the five-fold cross-validation. The outer-test predictions from all five folds were first pooled, giving one out-of-fold prediction for every case in the dataset. These pooled predictions were then divided, at the case level and stratified by cancer status, into a 20% threshold-search subset and a separate 80% evaluation subset for all five ablation configurations.
For each configuration, two operating thresholds were selected on the 20% threshold-search subset, corresponding to target cancer recalls of 98% and 95%. Because recall is discrete when the number of cancer-positive cases is limited, we selected the largest threshold whose empirical recall remained at or above the target value. The achieved recall on the threshold-search subset could therefore exceed the nominal target when the target value was not exactly attainable.
Once selected, each threshold was fixed and applied once to the independent 80% evaluation subset without further adjustment. No labels or outcomes from the evaluation subset were used to select or modify the operating thresholds. The dismissal rate, achieved cancer recall, and corresponding Clopper–Pearson upper confidence bound were calculated only on this evaluation subset.
For a fixed operating threshold, let be the total number of cases in the evaluation subset, the number of dismissed cases, the number of cancer-positive cases among those dismissed, and the total number of cancer-positive cases in the evaluation subset.
The dismissal fraction was calculated as
The achieved cancer recall was
To account for uncertainty in the observed cancer rate among dismissed cases, we calculated a one-sided Clopper–Pearson upper confidence bound:
where is the quantile of the beta distribution [38]. For the final evaluation, was used, corresponding to a one-sided 99% confidence level. The resulting value gives an upper confidence limit on the cancer prevalence within the dismissed group. Formal confidence bounds were calculated only at the case level, as discussed in Section 3.5.
3.8 Proposed closed-loop dismissal loss
The proposed training objective combines binary cross-entropy, focal loss [27], and a one-sided dismissal loss:
where is the number of cancer-positive images in the minibatch, is the predicted score for image , is a fixed margin, and is the provisional dismissal threshold at epoch .
The dismissal term is applied only to cancer-positive examples. A positive example receives an additional penalty when its score falls below , and the penalty increases as the score moves farther below this boundary. Positive examples with scores above the boundary receive no dismissal penalty. The cross-entropy and focal-loss terms continue to provide the classification signal for both positive and negative examples.
For the proposed closed-loop model, was recalculated at the beginning of each epoch using image-level predictions from that fold's training-calibration subset described in Section 3.6. We selected the largest threshold for which the one-sided 95% Clopper–Pearson upper bound on the positive-image rate among dismissed calibration images did not exceed 1%. If no threshold satisfied this criterion, was set to zero. This calculation was used only as a training-time signal and was separate from the final 99% case-level evaluation described in Section 3.7. No gradient was propagated through the threshold calculation.
Figure 1 illustrates the proposed closed-loop training mechanism.
The fixed hyperparameters were , , , and . The margin was used to maintain a buffer between cancer-positive scores and the current dismissal boundary, while the relatively small dismissal weight allowed this term to act as an auxiliary training signal alongside the cross-entropy and focal-loss objectives.
The threshold variable was initialized at 0.05. In the closed-loop configuration, it was replaced by the value recalculated from the training-calibration subset at the beginning of each epoch. In the fixed- ablation, remained at 0.05 throughout training. This comparison was used to separate the effect of dynamically updating the threshold from the effect of adding the dismissal loss itself.
3.9 Training protocol
All five configurations used the same data splits and training settings to ensure a fair comparison. The linear classification head was optimized using AdamW with a learning rate of and a weight decay of . Models were trained for 20 epochs with a minibatch size of 80, automatic mixed precision, and gradient clipping at a global norm of 5.0. No early stopping or validation-based checkpoint selection was used.
Because cancer-positive examples were much less common than negative examples, each training minibatch was constructed with 20 cancer-positive and 60 cancer-negative samples. Samples were drawn independently for each minibatch, allowing minority-class examples to be reused across minibatches as needed. Since balanced sampling changes the class distribution seen during training, the sigmoid outputs were treated as model scores rather than as population-calibrated probabilities of cancer.
3.10 Ablation configurations
Five training configurations were compared using the same data splits, training schedule, and evaluation procedure:
- CE-only baseline: binary cross-entropy was used as the sole training objective,
This configuration served as the primary baseline.
(a) Four-step threshold-aware training loop

(b) Illustrative evolution of the dynamically recomputed threshold

Figure 1: Closed-loop threshold-aware training. (a) Four-step training cycle in which the provisional threshold is recomputed from the training-calibration subset and used to penalize cancer-positive images with scores below . (b) Illustrative evolution of as the model score distribution changes during training. The blue region denotes the dismissal region (), and the hatched region denotes the positive-sample penalty condition (). Hollow and solid cancer-positive markers illustrate score movement under the dismissal penalty. Threshold evolution is illustrative and need not be monotonic.
- CE + Brier: binary cross-entropy was combined with Brier-score regularization,
where
and . This configuration was included to test whether a calibration-oriented training objective also improves safe-dismissal performance.
- CE + Focal: binary cross-entropy was combined with focal loss,
where
We used and .
- Fixed- dismissal: the full classification and dismissal objective was used,
with
For this configuration, the dismissal threshold was fixed at throughout training.
- Proposed closed-loop: the same full objective was used, but was recomputed from the training-calibration subset at the beginning of every epoch. The fixed hyperparameters were , , , and .
All five configurations were retained in the final comparison. None was selected or excluded based on test-set performance, and all were evaluated using the same threshold-certification and outer-test procedure described in Section 3.7.
3.11 External evaluation
For the external evaluation, one final CE-only model and one final closed-loop model were trained on RSNA and then applied to the external NLBS dataset without retraining the model weights. The external analysis focused on the primary CE-only baseline and the proposed closed-loop model, while the remaining configurations were evaluated in the controlled in-domain ablation study. For these final models, 90% of the RSNA cases were used for model fitting and the remaining 10% were used as the training-calibration subset, following the same training procedure and hyperparameters used in the in-domain experiments.
To keep the operating-point evaluation consistent across datasets, the same threshold-selection procedure used for the in-domain analyses was applied to the external evaluation. Cases were divided at the case level, with stratification by cancer status, into a 20% threshold-search subset and an independent 80% evaluation subset.
For each recall target, the operating threshold was selected using only the 20% threshold-search subset. Because recall is discrete when the number of cancer-positive cases is limited, the largest threshold whose empirical recall remained at or above the target value was selected. The threshold was then fixed and applied once to the independent 80% evaluation subset. No labels or outcomes from the evaluation subset were used to select or modify the operating threshold.
The model weights remained entirely RSNA-trained. Because prediction-score distributions may differ across datasets, the operating threshold for the external NLBS analysis was determined from the NLBS threshold-search subset rather than transferring an RSNA-derived threshold unchanged. Dismissal rate, achieved cancer recall, case-level AUROC, and the one-sided 99% Clopper–Pearson upper confidence bound were calculated only on the independent NLBS evaluation subset.
This experiment therefore evaluates cross-dataset performance with target-domain threshold calibration. It tests whether the behavior learned from RSNA is retained on an independent screening population when the model weights remain fixed and only the operating threshold is determined from a separate subset of the target dataset.
3.12 Evaluation metrics
Model discrimination was evaluated using the area under the receiver-operating characteristic curve (AUROC) at both the image and case levels. Case-level scores were obtained using the maximum-aggregation rule described in Section 3.4. AUROC was calculated on the independent 80% evaluation subset.
Safe-dismissal performance was evaluated at cancer-recall targets of 98% and 95%. For each target, the operating threshold was selected using only the 20% threshold-search subset, fixed, and then applied once to the independent 80% evaluation subset. We calculated the dismissal rate, achieved cancer recall, and the corresponding one-sided 99% Clopper–Pearson upper confidence bound on the independent evaluation subset. A dismissal result is reported at a given recall target only when the achieved recall on the evaluation subset met or exceeded that target; otherwise, the result is reported as N/A.
Formal certification was performed only at the case level. Image-level dismissal rates were reported as a secondary descriptive analysis and were not assigned a Clopper–Pearson confidence bound, as discussed in Section 3.5.
All reported case-level evaluation metrics were calculated only from the 80% evaluation subset. The 20% threshold-search subset was used only to select the operating thresholds and was not included in the reported performance estimates. For the descriptive image-level analysis, the same operating thresholds selected for the corresponding case-level recall targets were applied directly to the individual image scores; no separate image-level threshold selection was performed.
4 Results
Before presenting the results, we briefly clarify the interpretation of the Clopper–Pearson bound used throughout this section. For a given operating threshold, the dismissed group contains the cases that would not be sent for radiologist review. The one-sided 99% Clopper–Pearson upper bound (CPU99) represents an upper confidence bound on the cancer prevalence within this dismissed group. For example, a CPU99 value of 1.00% indicates that the one-sided 99% upper confidence limit on the cancer prevalence among dismissed cases is 1.00%. This quantity refers only to the dismissed group, not to the full cohort or to the proportion of all cancer cases that were missed. A lower CPU99 therefore represents a tighter upper confidence bound on cancer prevalence among dismissed cases. Because separate operating thresholds were selected for the 98% and 95% recall targets, the dismissed groups and their corresponding CPU99 bounds can differ between the two operating points.
4.1 In-domain ablation results: NLBS
Table 1 summarizes the NLBS results across the five training configurations. At the operating threshold selected for the 98% recall target, the proposed closed-loop model achieved the highest case-level dismissal rate, at 19.74%, together with the lowest CPU99 bound, at 0.70%. At the 95% recall-target operating point, it again achieved the highest case-level dismissal rate, at 21.70%, with a CPU99 bound of 0.81%. The same overall pattern was observed at the image level, where the proposed model achieved the highest dismissal rates at both operating thresholds, 14.80% at and 30.88% at . The proposed model also had the highest case-level AUROC on NLBS, at 0.7216.
Table 1: NLBS in-domain ablation results at the case and image levels. The independent 80% evaluation subset contained 4,797 cases, including 119 cancer-positive cases. The one-sided 99% Clopper–Pearson upper bound (CPU99) is reported only for case-level results. Image-level dismissal rates were calculated using images from the same 80% evaluation subset and the same thresholds selected on the corresponding 20% threshold-search subset; no separate image-level threshold search was performed.
| Configuration | Case @98% target | CPU99 | Case @95% target | CPU99 | Case AUROC | Image dismissal at | Image dismissal at |
|---|---|---|---|---|---|---|---|
| CE-only (baseline) | N/A | — | N/A | — | 0.7157 | 12.08% | 12.21% |
| CE + Brier | 12.07% | 1.14% | 12.53% | 1.39% | 0.7148 | 12.16% | 12.26% |
| CE + Focal | 10.92% | 1.26% | 16.36% | 1.47% | 0.7146 | 7.70% | 15.45% |
| Fixed- dismissal | 15.45% | 0.89% | 18.55% | 1.12% | 0.7160 | 12.29% | 17.59% |
| Proposed (closed-loop) | 19.74% | 0.70% | 21.70% | 0.81% | 0.7216 | 14.80% | 30.88% |
4.2 In-domain ablation results: RSNA
The RSNA results are shown in Table 2. As on NLBS, the proposed closed-loop model achieved the highest case-level dismissal rate at both recall-target operating points. At the threshold selected for the 98% recall target, the proposed model dismissed 14.31% of cases and produced the lowest CPU99 bound, at 1.06%. At the threshold selected for the 95% recall target, it dismissed 19.69% of cases with a CPU99 bound of 1.28%. The proposed model also achieved the highest image-level dismissal rates at both corresponding operating thresholds.
Table 2: RSNA in-domain ablation results at the case and image levels. The independent 80% evaluation subset contained 9,530 cases, including 389 cancer-positive cases. The one-sided 99% Clopper–Pearson upper bound (CPU99) is reported only for case-level results. Image-level dismissal rates were calculated using images from the same 80% evaluation subset and the same thresholds selected on the corresponding 20% threshold-search subset; no separate image-level threshold search was performed.
| Configuration | Case @98% target | CPU99 | Case @95% target | CPU99 | Case AUROC | Image dismissal at | Image dismissal at |
|---|---|---|---|---|---|---|---|
| CE-only (baseline) | 7.04% | 2.37% | 13.49% | 1.77% | 0.7219 | 10.51% | 16.57% |
| CE + Brier | 8.96% | 1.86% | 13.42% | 1.98% | 0.7215 | 10.35% | 16.49% |
| CE + Focal | 7.48% | 2.23% | 17.82% | 1.49% | 0.7267 | 7.10% | 21.08% |
| Fixed- dismissal | 9.91% | 1.69% | 17.10% | 1.56% | 0.7280 | 8.81% | 17.12% |
| Proposed (closed-loop) | 14.31% | 1.06% | 19.69% | 1.28% | 0.7136 | 11.03% | 23.24% |
One difference from NLBS was the AUROC ranking. On RSNA, the proposed model had a case-level AUROC of 0.7136, while the other configurations ranged from 0.7215 to 0.7280. Despite these relatively similar AUROC values, the dismissal results differed more clearly across configurations, with the proposed model achieving the highest dismissal rate and the lowest CPU99 bound at both recall targets. This shows that AUROC and dismissal performance are not necessarily aligned, particularly when performance is evaluated at specific high-recall operating points.
4.3 External validation: RSNA → NLBS
To evaluate performance across datasets, models trained on RSNA were applied to NLBS without retraining the model weights. The operating thresholds were selected on the NLBS search subset and then applied to the separate NLBS evaluation subset, following the procedure described in Section 3.11. Table 3 summarizes the case-level results.
Table 3: RSNA→NLBS external evaluation at the case level. Both models were trained exclusively on RSNA. Operating thresholds were selected using the 20% NLBS threshold-search subset and then fixed and applied once to the independent 80% NLBS evaluation subset. CPU99 denotes the one-sided 99% Clopper–Pearson upper confidence bound on cancer prevalence within the dismissed group.
| Configuration | Dismissal @98% target | CPU99 (@98%) | Dismissal @95% target | CPU99 (@95%) | AUROC |
|---|---|---|---|---|---|
| Baseline (CE-only) | N/A | N/A | 13.55% | 1.77% | 0.7184 |
| Proposed (closed-loop) | 12.95% | 1.06% | 19.87% | 1.37% | 0.7210 |
At the 98% recall target, the CE-only baseline did not reach the required recall level. The proposed closed-loop model reached the target while dismissing 12.95% of cases, with a CPU99 bound of 1.06%.
At the 95% recall target, both models reached the required recall level. The proposed model dismissed 19.87% of cases, compared with 13.55% for the baseline, an increase of 6.32 percentage points. Its CPU99 bound was also lower, at 1.37% compared with 1.77% for the baseline, indicating a tighter upper confidence bound on the cancer prevalence within the dismissed group.
Case-level AUROC was similar for the two models, with 0.7210 for the proposed model and 0.7184 for the baseline. Overall, the proposed model maintained its dismissal advantage when transferred from RSNA to NLBS with target-domain threshold calibration. It also reached the stricter 98% recall target, which the baseline did not reach under the same evaluation procedure.
4.4 Summary across settings
Table 4 summarizes the case-level dismissal results across the two in-domain evaluations and the external RSNA→NLBS evaluation. For the in-domain datasets, the proposed model is compared with the non-proposed configuration that achieved the highest dismissal rate at each recall-target operating point. For the external evaluation, the comparison is made against the RSNA-trained CE-only baseline.
Across both in-domain datasets, the proposed closed-loop model achieved the highest case-level dismissal rate at the operating thresholds selected for the 98% and 95% recall targets. On NLBS, dismissal reached 19.74% and 21.70%, compared with 15.45% and 18.55% for the strongest alternatives at the corresponding operating points. The associated CPU99 bounds were also lower for the proposed model, decreasing from 0.89% to 0.70% at the 98% recall-target operating point and from 1.12% to 0.81% at the 95% recall-target operating point.
On RSNA, the proposed model dismissed 14.31% of cases at the 98% recall-target operating point, compared with 9.91% for the strongest alternative, while CPU99 decreased from 1.69% to
Table 4: Summary of case-level dismissal rates and one-sided 99% Clopper-Pearson upper confidence bounds (CPU99) across the three evaluation settings. For the in-domain comparisons, the best alternative is the non-proposed configuration with the highest dismissal rate at the corresponding recall-target operating point. For RSNA, fixed- is the best alternative at the 98% recall target and CE + Focal at the 95% recall target.
| Setting | Configuration | @98% target | CPU99 | @95% target | CPU99 |
|---|---|---|---|---|---|
| NLBS in-domain | Best alternative (Fixed-) | 15.45% | 0.89% | 18.55% | 1.12% |
| Proposed | 19.74% | 0.70% | 21.70% | 0.81% | |
| RSNA in-domain | Best alternative | 9.91% | 1.69% | 17.82% | 1.49% |
| Proposed | 14.31% | 1.06% | 19.69% | 1.28% | |
| RSNA→NLBS external | Baseline (CE-only) | N/A | — | 13.55% | 1.77% |
| Proposed | 12.95% | 1.06% | 19.87% | 1.37% |
1.06%. At the 95% recall-target operating point, dismissal increased from 17.82% to 19.69%, while CPU99 decreased from 1.49% to 1.28%.
The external RSNA→NLBS evaluation showed the same overall pattern. At the 95% recall target, the proposed model dismissed 19.87% of cases compared with 13.55% for the CE-only baseline, while CPU99 decreased from 1.77% to 1.37%. At the stricter 98% recall target, the proposed model reached the required operating point with 12.95% dismissal and a CPU99 of 1.06%, whereas the baseline did not reach the target.
AUROC did not follow the same ordering across datasets. The proposed model had the highest AUROC on NLBS, the lowest among the five configurations on RSNA, and a slightly higher AUROC than the baseline in the external evaluation. This indicates that AUROC and dismissal performance are not necessarily aligned. Despite these differences in AUROC, the proposed model achieved the highest case-level dismissal rate at both recall-target operating points in the two in-domain evaluations and also achieved higher dismissal than the CE-only baseline in the external evaluation. It also achieved the highest reported image-level dismissal rate at both corresponding operating thresholds in the two in-domain analyses.
5 Discussion
5.1 Evidence in support of the main claim
The main finding of this study is the consistency of the dismissal improvement across datasets and operating points. On both NLBS and RSNA, the proposed closed-loop model achieved the highest case-level dismissal rate at the 98% and 95% recall targets, while also producing the lowest CPU99 bound at each operating point. This pattern was observed despite differences between the two datasets in prevalence, population, and image acquisition.
The comparison with the fixed- ablation is particularly informative because the two configurations use the same dismissal loss and differ primarily in whether the threshold is updated during training. At the 98% recall target, closed-loop recomputation increased dismissal from 15.45% to 19.74% on NLBS, a gain of 4.29 percentage points, and from 9.91% to 14.31% on RSNA, a gain of 4.40 percentage points. The same direction was observed at the 95% recall target, where dismissal increased from 18.55% to 21.70% on NLBS and from 17.10% to 19.69% on RSNA. Importantly, these increases were not obtained at the expense of a weaker statistical bound. CPU99 also decreased at each of these comparisons.
Taken together, these results suggest that the benefit does not come only from adding a dismissal-oriented penalty to the loss. Updating the dismissal boundary during training appears to provide an additional advantage over keeping that boundary fixed. The consistency of this difference across two datasets and two recall targets is more informative than any single percentage-point gain.
The AUROC results provide an additional perspective. On NLBS, the proposed model had the highest AUROC, whereas on RSNA it had the lowest AUROC among the five configurations, with all models remaining within a relatively narrow range. Yet the proposed model achieved the strongest dismissal performance on both datasets. This suggests that overall ranking performance, as summarized by AUROC, and performance at a specific high-recall dismissal operating point are related but not interchangeable. For the intended use considered here, the latter is the quantity that directly determines how many examinations can be dismissed while maintaining the required cancer recall.
5.2 Consistency between case- and image-level results
The case- and image-level results showed a consistent pattern across both datasets. The proposed model achieved the highest dismissal rate at both recall targets not only after case-level aggregation, but also when the images were evaluated individually. On NLBS, image-level dismissal reached 14.80% at and 30.88% at . On RSNA, the corresponding rates were 11.03% and 23.24%. These were the highest image-level dismissal rates among the five configurations at each operating point.
This consistency is important because the primary analysis uses maximum aggregation across the images belonging to a case. An improvement seen only after aggregation could raise the possibility that the result depends strongly on the aggregation rule. Instead, the same overall advantage was observed before aggregation at the image level. The findings therefore suggest that the improvement is not limited to the case-level decision rule, but is also reflected in the underlying image-level score behavior.
The image-level analysis remains descriptive, since the formal Clopper-Pearson confidence bound is applied only at the case level. Nevertheless, the agreement between the two levels provides additional support that the observed dismissal advantage is not an artifact of case-level aggregation alone.
5.3 Discrimination and dismissal performance capture different aspects of model behavior
The relationship between AUROC and dismissal performance was not consistent across the three evaluation settings. On NLBS, the proposed model achieved the highest case-level AUROC as well as the highest dismissal rates. On RSNA, however, it had the lowest AUROC among the five configurations while still achieving the highest dismissal rate and the lowest CPU99 bound at both recall targets. In the external RSNA→NLBS evaluation, AUROC was similar for the proposed model and the CE-only baseline, while the proposed model showed a clear advantage in dismissal performance.
These results suggest that AUROC alone does not fully describe performance for the dismissal task considered here. AUROC summarizes how well a model ranks positive and negative cases across the full range of possible thresholds. In contrast, the dismissal analysis evaluates the model at specific high-recall operating points, where the practical question is how many cases can be dismissed while maintaining the required cancer recall and controlling the cancer rate within the dismissed group. Models with similar AUROC values can therefore behave differently at these particular operating points.
This distinction is especially relevant to the objective used in the proposed model. The dismissal term does not directly optimize global ranking performance. Instead, it penalizes cancer-positive examples that fall too close to the current dismissal boundary. Its effect may therefore be reflected more clearly in dismissal performance than in a threshold-free summary measure such as AUROC. The RSNA results illustrate this point most clearly: the proposed model did not improve AUROC, yet it achieved both a higher dismissal rate and a lower CPU99 bound.
More broadly, clinical prediction studies have emphasized that different performance measures describe different properties of a model and should not be treated as interchangeable [39, 40]. Our results show a similar distinction between overall discrimination and performance at a specific safety-sensitive operating point. For a system intended to support safe dismissal, both remain important, but AUROC by itself is not sufficient to characterize how the model behaves under the intended decision rule.
5.4 External validation under domain shift
The external RSNA→NLBS evaluation provides encouraging evidence that the dismissal advantage is not limited to the dataset on which the model was trained. The model weights were learned entirely from RSNA and were kept fixed when the models were evaluated on NLBS. To account for the change in data distribution, the operating thresholds for both models were selected using the NLBS threshold-search subset and then applied without further adjustment to the separate NLBS evaluation subset.
The difference between the two models was most apparent at the stricter 98% recall target. The proposed model reached this operating point while dismissing 12.95% of cases, with a CPU99 bound of 1.06%. The CE-only baseline did not reach the required recall target under the same evaluation procedure. At the 95% recall target, both models reached the target, but the proposed model dismissed 19.87% of cases compared with 13.55% for the baseline. The corresponding CPU99 bound was also lower for the proposed model, at 1.37% compared with 1.77%.
These results are notable because the advantage was retained even though the model parameters had not been fitted to the NLBS population. Both models were given the same opportunity to calibrate their operating threshold on target-domain data, so the comparison does not depend on applying an RSNA-derived threshold unchanged to a different population. Instead, it asks whether the advantage learned during training remains after both models are adapted to the new dataset only through threshold selection. Under this setting, the closed-loop model continued to dismiss more cases while maintaining the required recall level.
The external AUROC values were similar, at 0.7210 for the proposed model and 0.7184 for the baseline, while their dismissal performance differed more clearly. This is consistent with the in-domain findings and further shows that similar overall discrimination does not necessarily lead to similar performance at a specific high-recall operating point.
The result should nevertheless be interpreted as evidence of cross-dataset robustness rather than proof of universal generalizability. Only one external target dataset was evaluated, and the operating threshold was recalibrated using target-domain data before final evaluation. Further validation across institutions, acquisition systems, and screening populations would be needed to determine how consistently the observed advantage transfers to other clinical settings.
5.5 Clinical relevance and intended role
The clinical role considered in this study is selective workload reduction, rather than replacement of radiologist interpretation. The model is used to identify a low-score subset of screening examinations that may be eligible for dismissal while maintaining a predefined cancer-recall requirement. The accompanying CPU99 bound provides an additional measure of uncertainty by placing a one-sided upper confidence bound on the cancer prevalence within that dismissed group.
This distinction is important when interpreting the results. The dismissal rates reported here should not be compared directly with radiologist sensitivity, false-negative rates, or other measures calculated over the entire screening population. These quantities answer different questions. Our analysis focuses specifically on the composition of the subset selected for dismissal and on how large that subset can become while preserving the required recall level.
Previous studies, including the MASAI trial [12, 13, 14] and the international evaluation by McKinney et al. [11], have shown that AI can contribute to screening workflows in ways that reduce radiologist workload. We view the present method as complementary to this broader direction. Rather than proposing a complete clinical reading system, it provides a model-level framework for defining and auditing a dismissal operating point under an explicit statistical criterion.
The magnitude of the observed dismissal rates suggests that this approach could translate into a meaningful reduction in the number of examinations requiring review. At the stricter 98% recall target, the proposed model dismissed 19.74% of cases in the NLBS in-domain evaluation and 14.31% on RSNA. In the external RSNA→NLBS evaluation, the RSNA-trained model continued to dismiss 12.95% of cases after target-domain threshold calibration while reaching the same recall target. At the 95% recall target, the corresponding dismissal rates increased further.
These results establish the potential of the method as a selective screening component rather than as a stand-alone diagnostic system. Its practical value lies in identifying a substantial subset of examinations for which review may potentially be avoided under a predefined operating criterion, while keeping the decision rule and its statistical uncertainty explicit and auditable. Prospective workflow studies would be the next step to determine how this reduction translates into radiologist workload, screening efficiency, and clinical outcomes in practice.
5.6 Potential economic implications of selective dismissal
The NLBS results also provide an indication of the potential economic scale of selective dismissal in population-based screening. At the stricter operating point selected for a cancer-recall target of at least 98%, TRUST dismissed 19.74% of screening examinations from manual review. This corresponds to approximately 197 fewer radiologist interpretations for every 1,000 screening examinations. Importantly, this represents a reduction in manual interpretation rather than avoidance of the mammographic examination itself, since image acquisition and the associated technical and administrative costs would still occur.
As an illustrative estimate, the Ontario physician fee schedule assigns a professional interpretation component of approximately CAD6,100 per 1,000 screening examinations. The population-level scale could be considerably larger. For example, in a hypothetical screening program serving 10 million women aged 40 years or older, if each woman underwent one screening examination during a screening round, a 19.74% dismissal rate would correspond to approximately 1.97 million examinations not requiring manual radiologist interpretation. Using the same illustrative professional fee, this represents approximately CAD$61.2 million in gross interpretation costs per screening round. These figures are intended to illustrate the potential economic scale of workload reduction rather than realized health-system savings. Actual savings would depend on screening participation and frequency, local reimbursement models, workflow implementation, and the costs of deploying and maintaining the AI system. Importantly, this estimate considers only the professional interpretation component and does not include any potential additional savings from fewer recalls, supplemental imaging examinations, benign biopsies, or other downstream diagnostic procedures. Such downstream effects could further increase the economic benefit of selective dismissal, but they were not quantified in the present study.
5.7 Why dynamic threshold recomputation may matter
The comparison between the fixed- and closed-loop configurations provides some insight into why updating the dismissal threshold during training may be useful. The score distribution of a model is not fixed while the classifier is being optimized. As training progresses, the relative positions of positive and negative examples can shift, meaning that a dismissal boundary chosen at the beginning of training may no longer represent the operating region that the model currently produces.
With a fixed threshold, the dismissal loss therefore continues to act relative to the same numerical boundary throughout training. In the closed-loop model, the provisional threshold is recalculated from the current model outputs and is then used to define the positive-side dismissal penalty for the next stage of optimization. This creates a simple feedback mechanism in which the training signal remains tied to the model's evolving score distribution rather than to a threshold that may become progressively less representative.
The ablation results are consistent with this interpretation. Replacing the fixed threshold with the dynamically recomputed threshold improved case-level dismissal on both NLBS and RSNA and at both recall targets, while also producing lower CPU99 bounds. Because the two configurations otherwise share the same dismissal-loss structure, this comparison suggests that adapting the boundary during training contributes beyond the effect of introducing the dismissal penalty alone.
These results do not establish the exact mechanism by which the score distribution changes during training. A more detailed analysis of score trajectories, threshold evolution, and class-conditional score distributions would be needed to demonstrate that mechanism directly. Nevertheless, the consistency of the fixed- comparison across both datasets supports the practical value of keeping the dismissal objective connected to the model's current operating behavior.
5.8 Limitations
Several limitations should be considered when interpreting these results.
-
Limited number of cancer-positive cases in NLBS. Although NLBS contains 5,997 screening examinations, only 149 are cancer-positive. This limits the resolution of recall-based threshold selection, particularly within the 20% threshold-search subset, and makes the selected operating threshold more sensitive to individual positive cases. The agreement between NLBS and the larger RSNA dataset is therefore important, but additional evaluation in larger screening cohorts would provide more stable threshold estimates.
-
Sensitivity to loss hyperparameters was not systematically evaluated. The margin was introduced to maintain a buffer between cancer-positive scores and the current dismissal boundary, while was chosen to keep the dismissal term as an auxiliary component of the overall training objective. These values were fixed across both datasets
and were not optimized separately for individual experiments. Although the same setting produced consistent results on NLBS and RSNA, a broader sensitivity analysis would be useful to determine how strongly dismissal performance depends on these hyperparameters.
-
Comparison with established selective-classification methods is limited. The current experiments compare the proposed method with controlled ablations of the same model and training pipeline. We did not directly compare it with dedicated selective-classification approaches such as SelectiveNet [16] or with conformal risk-control methods [18] under matched operating conditions. Such comparisons would help clarify how much benefit is provided by the proposed closed-loop training strategy relative to alternative approaches to risk control and selective prediction.
-
A single backbone and pre-training source were used. All experiments used a frozen EfficientNet-B5 encoder initialized from the same Mammo-CLIP checkpoint. The consistency of the results across NLBS and RSNA is encouraging, but it remains unknown whether the same improvement would be obtained with other architectures, feature extractors, or mammography pre-training strategies.
-
Formal confidence bounds are limited to the case level. The Clopper–Pearson analysis assumes that each evaluated unit contributes an independent outcome. Multiple images from the same examination are not independent, so treating them as separate Bernoulli observations would not support the same statistical interpretation. For this reason, CPU99 is reported only for the case-level analysis. Image-level dismissal rates are included as descriptive supporting results and should not be interpreted as formally certified bounds.
-
Clinical validation remains retrospective. The study evaluates model behavior retrospectively on existing datasets and does not measure the effect of dismissal on radiologist workflow, reading time, recall decisions, or patient outcomes. The reported dismissal rates therefore establish technical potential under the defined operating criteria, but prospective evaluation would be required before the method could be used to support real screening decisions.
6 Conclusion
We introduced a closed-loop training approach for mammography dismissal that repeatedly updates a provisional dismissal threshold during training and uses this threshold to shape a positive-class penalty. The purpose is to align model optimization more closely with the high-recall operating region used for selective dismissal, while keeping final threshold selection and statistical evaluation separate from the training process.
Across both NLBS and RSNA, the proposed model achieved the highest case-level dismissal rate at the operating thresholds selected for the 98% and 95% recall targets and produced the lowest one-sided 99% Clopper–Pearson upper bound (CPU99) at each operating point. The image-level results showed the same overall pattern in both in-domain evaluations. The comparison with the fixed- ablation further suggests that dynamically updating the dismissal boundary provides an additional benefit beyond simply adding a dismissal-oriented loss term.
The results also showed that AUROC and dismissal performance do not necessarily move together. The proposed model achieved the highest AUROC on NLBS but the lowest among the evaluated configurations on RSNA, while still achieving the highest case-level dismissal rates at both recall-target operating points. This distinction is important because the objective of the proposed method is not simply to improve overall ranking performance, but to improve model behavior in the high-recall region relevant to selective dismissal.
The same overall pattern was observed in the external RSNA→NLBS evaluation. The model weights were learned entirely from RSNA and remained fixed. Operating thresholds were selected using the 20% NLBS threshold-search subset and then applied without adjustment to the independent 80% evaluation subset. At the 98% recall target, the proposed model dismissed 12.95% of NLBS cases with a CPU99 of 1.06%, whereas the CE-only baseline did not reach the required recall level. At the 95% recall target, the proposed model dismissed 19.87% of cases compared with 13.55% for the baseline, while CPU99 was lower at 1.37% compared with 1.77%.
Overall, these findings suggest that closed-loop threshold-aware training can improve selective-dismissal performance relative to conventional classification training and a fixed-threshold dismissal objective. The reported statistical certificate applies specifically to the one-sided upper confidence bound on cancer prevalence within the dismissed evaluation cases and should not be interpreted as a guarantee of future clinical safety. Further evaluation across additional screening populations, model architectures, and prospective clinical workflows will be needed to determine how reliably these findings translate to real-world deployment.
Compliance with Ethical Standards
This retrospective computational study used only publicly available, de-identified mammography datasets. The Newfoundland and Labrador Breast Screening (NLBS) dataset is publicly available through the Federated Research Data Repository (FRDR), and the RSNA Screening Mammography Breast Cancer Detection dataset is publicly available through the RSNA/Kaggle challenge. No additional institutional ethical approval was required for this secondary analysis of publicly available, de-identified data.
Conflict of Interest
The authors declare no conflicts of interest.
Data and Code Availability
The datasets used in this study are publicly available. The Newfoundland and Labrador Breast Screening (NLBS) dataset is available through the Federated Research Data Repository (FRDR) [34], and the RSNA Screening Mammography Breast Cancer Detection dataset is publicly available through the RSNA/Kaggle challenge [35]. No new clinical data were generated as part of this study.
Acknowledgments
This work was supported by the Seed, Bridge, and Multidisciplinary Fund at Memorial University of Newfoundland.
References
[1] US Preventive Services Task Force. Screening for breast cancer: Us preventive services task force recommendation statement. JAMA, 331(22):1918–1930, 06 2024.
[2] Debra L. Monticciolo, Sharp F. Malak, Sarah M. Friedewald, Peter R. Eby, Mary S. Newell, Linda Moy, Stamatia Destounis, Jessica W.T. Leung, R. Edward Hendrick, and Dana Smetherman. Breast cancer screening recommendations inclusive of all women at average risk: Update from the acr and society of breast imaging. Journal of the American College of Radiology, 18(9):1280–1288, 2021. Focus on Care Transformation.
[3] Kevin C. Oeffinger, Elizabeth T. H. Fontham, Ruth Etzioni, Abbe Herzig, James S. Michaelson, Ya-Chen Tina Shih, Louise C. Walter, Timothy R. Church, Christopher R. Flowers, Samuel J. LaMonte, Andrew M. D. Wolf, Carol DeSantis, Joannie Lortet-Tieulent, Kimberly Andrews, Deana Manassaram-Baptiste, Debbie Saslow, Robert A. Smith, Otis W. Brawley, and Richard Wender. Breast cancer screening for women at average risk: 2015 guideline update from the american cancer society. JAMA, 314(15):1599–1614, 10 2015.
[4] Stamatia V. Destounis, Sarah M. Friedewald, Lars J. Grimm, Steven P. Poplack, and Jessica S. Sung. Mammography. In ACR BI-RADS® v2025 Manual. American College of Radiology, Reston, VA, 2025.
[5] Erika Marina Solla Negrao, Mariana Alves Almeida, Emanuele Francoso Cardoso, Alvaro Silva Almeida, Samanta Santos Sousa, Cassio Cardoso-Filho, Rodrigo Menezes Jales, and Diana Bhadra Vale. Subsequent mammography reduces recall and increases breast cancer detection: an audit of a screening program. Rev. Bras. Ginecol. Obstet., 47(e-rbgo89):e-rbgo89, November 2025.
[6] Bianca M den Dekker, Mireille J M Broeders, Carla Meeuwis, Wikke Setz-Pels, Alexander Venmans, Carla H van Gils, and Ruud M Pijnappel. Diagnostic accuracy of supplemental three-dimensional breast ultrasound in the work-up of BI-RADS 0 screening recalls. Insights Imaging, 15(1):131, May 2024.
[7] Samuel J. Magny, Rachel Shikhman, and Ana L. Keppke. Breast imaging reporting and data system. In StatPearls. StatPearls Publishing, Treasure Island (FL), January 2026. PMID: 29083600.
[8] Rebecca A Hubbard, Karla Kerlikowske, Chris I Flowers, Bonnie C Yankaskas, Weiwei Zhu, and Diana L Miglioretti. Cumulative probability of false-positive recall or biopsy recommendation after 10 years of screening mammography: a cohort study. Ann. Intern. Med., 155(8):481–492, October 2011.
[9] Anna N Wilkinson, James G Mainprize, Martin J Yaffe, Jessica Robinson, Erin Cordeiro, Nicole J Look Hong, Phillip Williams, Nikitha Moideen, Julie Renaud, Jean M Seely, and Moira Rushton. Cost-effectiveness of breast cancer screening using digital mammography in canada. JAMA Netw. Open, 8(1):e2452821, January 2025.
[10] Nan Wu, Jason Phang, Jungkyu Park, Yiqiu Shen, Zhe Huang, Masha Zorin, Stanislaw Jas-trzebski, Thibault Fevry, Joe Katsnelson, Eric Kim, Stacey Wolfson, Ujas Parikh, Sushma Gaddam, Leng Leng Young Lin, Kara Ho, Joshua D Weinstein, Beatriu Reig, Yiming Gao, Hildegard Toth, Kristine Pysarenko, Alana Lewin, Jiyon Lee, Krystal Airola, Eralda Mema,
Stephanie Chung, Esther Hwang, Naziya Samreen, S Gene Kim, Laura Heacock, Linda Moy, Kyunghyun Cho, and Krzysztof J Geras. Deep neural networks improve radiologists' performance in breast cancer screening. IEEE Trans. Med. Imaging, 39(4):1184–1194, April 2020.
[11] Scott Mayer McKinney, Marcin Sieniek, Varun Godbole, Jonathan Godwin, Natasha Antropova, Hutan Ashrafan, Trevor Back, Mary Chesus, Greg S Corrado, Ara Darzi, Mozzi-yar Etemadi, Florencia Garcia-Vicente, Fiona J Gilbert, Mark Halling-Brown, Demis Hassabis, Sunny Jansen, Alan Karthikesalingam, Christopher J Kelly, Dominic King, Joseph R Ledsam, David Melnick, Hormuz Mostofi, Lily Peng, Joshua Jay Reicher, Bernardino Romera-Paredes, Richard Sidebottom, Mustafa Suleyman, Daniel Tse, Kenneth C Young, Jeffrey De Fauw, and Shravya Shetty. International evaluation of an AI system for breast cancer screening. Nature, 577(7788):89–94, January 2020.
[12] Kristina Lång, Viktoria Josefsson, Anna-Maria Larsson, Stefan Larsson, Charlotte Högberg, Hanna Sartor, Solveig Hofvind, Ingvar Andersson, and Aldana Rosso. Artificial intelligence-supported screen reading versus standard double reading in the mammography screening with artificial intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study. Lancet Oncol., 24(8):936–944, August 2023.
[13] Veronica Hernström, Viktoria Josefsson, Hanna Sartor, David Schmidt, Anna-Maria Larsson, Solveig Hofvind, Ingvar Andersson, Aldana Rosso, Oskar Hagberg, and Kristina Lång. Screening performance and characteristics of breast cancer detected in the mammography screening with artificial intelligence trial (MASAI): a randomised, controlled, parallel-group, non-inferiority, single-blinded, screening accuracy study. Lancet Digit. Health, 7(3):e175–e183, March 2025.
[14] Jessie Gommers, Veronica Hernström, Viktoria Josefsson, Hanna Sartor, David Schmidt, Annie Hjelmgren, Anna-Maria Larsson, Solveig Hofvind, Ingvar Andersson, Aldana Rosso, Oskar Hagberg, and Kristina Lång. Interval cancer, sensitivity, and specificity comparing AI-supported mammography screening with standard double reading without AI in the MASAI study: a randomised, controlled, non-inferiority, single-blinded, population-based, screening-accuracy trial. Lancet, 407(10527):505–514, January 2026.
[15] Yonatan Geifman and Ran El-Yaniv. Selective classification for deep neural networks. In Proceedings of the 31st International Conference on Neural Information Processing Systems, NIPS'17, page 4885–4894, Red Hook, NY, USA, 2017. Curran Associates Inc.
[16] Yonatan Geifman and Ran El-Yaniv. SelectiveNet: A deep neural network with an integrated reject option. In Kamalika Chaudhuri and Ruslan Salakhutdinov, editors, Proceedings of the 36th International Conference on Machine Learning, volume 97 of Proceedings of Machine Learning Research, pages 2151–2159. PMLR, 2019.
[17] Stephen Bates, Anastasios Angelopoulos, Lihua Lei, Jitendra Malik, and Michael Jordan. Distribution-free, risk-controlling prediction sets. J. ACM, 68(6), September 2021.
[18] Anastasios Nikolas Angelopoulos, Stephen Bates, Adam Fisch, Lihua Lei, and Tal Schuster. Conformal risk control. In The Twelfth International Conference on Learning Representations, 2024.
[19] Mi-Ri Kwon, Yoosoo Chang, Soo-Youn Ham, Yoosun Cho, Eun Young Kim, Jeonggyu Kang, Eun Kyung Park, Ki Hwan Kim, Minjeong Kim, Tae Soo Kim, Hyeonsoo Lee, Ria Kwon, Ga-Young Lim, Hye Rin Choi, Junhyeok Choi, Shin Ho Kook, and Seungho Ryu. Screening mammography performance according to breast density: a comparison between radiologists versus standalone intelligence detection. Breast Cancer Res., 26(1):68, April 2024.
[20] Suzanne L van Winkel, Jim Peters, Natasja Janssen, Jaap Kroes, Elizabeth A Loehrer, Jessie Gommers, Ioannis Sechopoulos, Linda de Munck, Jonas Teuwen, Mireille Broeders, Nico Karssemeijer, and Ritse M Mann. AI as an independent second reader in detection of clinically relevant breast cancers within a population-based screening programme in the netherlands: a retrospective cohort study. Lancet Digit. Health, 7(8):100882, August 2025.
[21] Nora Eisemann, Stefan Bunk, Trasias Mukama, Hannah Baltus, Susanne A Elsner, Timo Gomille, Gerold Hecht, Sylvia Heywang-Köbrunner, Regine Rathmann, Katja Siegmann-Luz, Thilo Töllner, Toni Werner Vomweg, Christian Leibig, and Alexander Katalinic. Nationwide real-world implementation of AI for cancer detection in population-based mammography screening. Nat. Med., 31(3):917–924, March 2025.
[22] Michael H. Bernstein, Maggie Chung, Adam Yala, and Grayson L. Baird. A novel statistical framework for quantifying risks and benefits of AI automation in screening mammography. PLOS Digital Health, 5(2):e0001231, 2026.
[23] Shantanu Ghosh, Clare B Poynton, Shyam Visweswaran, and Kayhan Batmanghelich. Mammo-CLIP: A vision language foundation model to enhance data efficiency and robustness in mammography. In Medical Image Computing and Computer Assisted Intervention – MICCAI 2024, pages 632–642. Springer Nature Switzerland, Cham, 2024.
[24] Anastasios N. Angelopoulos and Stephen Bates. A gentle introduction to conformal prediction and distribution-free uncertainty quantification, 2021. arXiv:2107.07511 [cs.LG].
[25] Christopher Yeh, Nicolas Christianson, Adam Wierman, and Yisong Yue. Conformal risk training: End-to-end optimization of conformal risk control. In Advances in Neural Information Processing Systems, volume 38, 2025.
[26] Abhishek Singh Sambyal, Usma Niyaz, Narayanan C. Krishnan, and Deepti R. Bathula. Understanding calibration of deep neural networks for medical image classification. Computer Methods and Programs in Biomedicine, 242:107816, 2023.
[27] Tsung-Yi Lin, Priya Goyal, Ross Girshick, Kaiming He, and Piotr Dollár. Focal loss for dense object detection. In Proceedings of the IEEE International Conference on Computer Vision (ICCV), pages 2980–2988, 2017.
[28] Jishnu Mukhoti, Viveka Kulharia, Amartya Sanyal, Stuart Golodetz, Philip H. S. Torr, and Puneet K. Dokania. Calibrating deep neural networks using focal loss. In Advances in Neural Information Processing Systems, volume 33, 2020.
[29] Jörg Sander, Bob D de Vos, and Ivana Išgum. Automatic segmentation with detection of local segmentation failures in cardiac MRI. Sci. Rep., 10(1):21769, December 2020.
[30] John R. Zech, Marcus A. Badgeley, Manway Liu, Anthony B. Costa, Joseph J. Titano, and Eric K. Oermann. Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study. PLOS Medicine, 15(11):e1002683, 2018.
[31] Lidia Garrucho, Kaisar Kushibar, Socayna Jouide, Oliver Diaz, Laura Igual, and Karim Lekadir. Domain generalization in deep learning based mass detection in mammography: A large-scale multi-center study. Artificial Intelligence in Medicine, 132:102386, 2022.
[32] Parham Hajishafiezahramini, Matthew Hamilton, Oscar Meruvia-Pastor, and Edward Kendall. Dataset-origin signatures and shortcut learning in screening mammography AI: A cross-dataset case study. arXiv preprint, July 2026. arXiv:2607.15416 [cs.CV].
[33] E. Kendall, P. Hajishafiezahramini, M. Hamilton, et al. Full field digital mammography dataset from a population screening program. Scientific Data, 12:1479, 2025.
[34] Edward Kendall, Parham Hajishafiezahramini, Matthew Hamilton, Gregory Doyle, Nancy Wadden, and Oscar Meruvia-Pastor. Newfoundland and labrador breast screening (NLBS) dataset (NL-Breast-Screen). Federated Research Data Repository, 2025.
[35] Hari M. Trivedi, Maryam Vazirabad, Felipe C. Kitamura, Yan Chen, and Helen Frazer. Open-source dataset for the RSNA screening mammography cancer detection challenge. Radiology: Artificial Intelligence, 8(2):e250375, 2026.
[36] DICOM Standards Committee. Digital imaging and communications in medicine (DICOM), part 3: Information object definitions. Technical Report PS3.3, National Electrical Manufacturers Association, 2025.
[37] Mingxing Tan and Quoc Le. EfficientNet: Rethinking model scaling for convolutional neural networks. In Kamalika Chaudhuri and Ruslan Salakhutdinov, editors, Proceedings of the 36th International Conference on Machine Learning, volume 97 of Proceedings of Machine Learning Research, pages 6105–6114. PMLR, 09–15 Jun 2019.
[38] C. J. CLOPPER and E. S. PEARSON. The use of confidence or fiducial limits illustrated in the case of the binomial. Biometrika, 26(4):404–413, 12 1934.
[39] Ben Van Calster, David J. McLernon, Maarten van Smeden, Laure Wynants, and Ewout W. Steyerberg. Calibration: the achilles heel of predictive analytics. BMC Medicine, 17:230, 2019.
[40] Yingxiang Huang, Wentao Li, Fima Macheret, Rodney A. Gabriel, and Lucila Ohno-Machado. A tutorial on calibration measurements and calibration models for clinical prediction models. Journal of the American Medical Informatics Association, 27(4):621–633, 2020.
[41] Ontario Ministry of Health. Fee code table 4: Value changes to fee schedule codes – physician services. Government of Ontario, April 2023. Effective April 1, 2023.