arXiv:2609.00769cs.ROSep 2026

Manuscript Offprint

arXiv:2609.00769

A Compact Robotic Finger with 2-DoF MCP Joint Embedding DoF-Selective Passive Continuously Variable Transmission for Wide Force-Speed Operating Range

JaeHyung Jang, Jee-Hwan Ryu

JaeHyung Jang and Jee-Hwan Ryu

Abstract—This letter presents a compact two-degree-of-freedom (DoF) robotic finger with a flexion-selective passive continuously variable transmission (CVT) to achieve a wide force-speed operating range. Inspired by the functional differentiation of the human metacarpophalangeal (MCP) joint, the proposed mechanism realizes DoF-specific transmission differentiation by selectively assigning passive CVT to the flexion-extension DoF while preserving direct transmission for abduction-adduction. For a wide force-speed operating range, a force-responsive passive CVT is embedded in the flexion pathway, while direct transmission is preserved for the abduction-adduction pathway. To selectively realize transmission adaptation within a multi-DoF MCP mechanism, an output-side passive CVT employing a moving-pulley-inspired wire-routing structure is introduced. The resultant force generated by the wire tensions acting on the pulley that passively increases the flexion moment arm and transmission ratio according to the applied load without additional actuators, sensors, or control. Experimental results demonstrate a maximum output-force amplification of 4.19-fold and a mean amplification of 3.6-fold across the tested flexion angles ranging from 15° to 75° through moment-arm adaptation, thereby substantially expanding the achievable force-speed operating range. Furthermore, dexterous ball-rolling experiments verify that passive transmission adaptation can be achieved while preserving abduction-adduction functionality. These results demonstrate a scalable transmission design strategy for compact multi-DoF robotic hands.

I. INTRODUCTION

The human hand achieves remarkable dexterity by simultaneously realizing delicate manipulation, powerful grasping, and rapid finger motion within a compact musculoskeletal structure [1]. This capability enables versatile object manipulation and precise force regulation in unstructured environments and has long served as a benchmark for robotic hand development [2]. However, achieving these performance requirements within compact robotic hands remains challenging. In in-finger architectures, limited installation volume fundamentally constrains actuator output, making it difficult to simultaneously achieve high grasping force and rapid joint motion. These mechanically conflicting requirements create an inherent force-speed tradeoff and represent a major limitation in compact multi-DoF robotic hands [3].

Tendon-driven actuation and variable transmission (VT) have been extensively investigated to address this challenge. Tendon-driven architectures relocate actuators to the forearm and transmit force through wires, enabling the use of actuators

with substantially higher output than can be embedded within the finger [4]–[6]. However, wire paths crossing the wrist joint introduce motion coupling between wrist posture and finger motion, while accumulated friction along extended routing paths degrades force transmission efficiency and control precision. These effects can complicate accurate force and motion transmission in compact multi-DoF robotic hands.

Variable transmission mitigates the force-speed tradeoff by adapting the transmission ratio according to operating conditions. Active VT mechanisms achieve transmission adaptation through dedicated actuators, sensors, and control, providing versatile transmission characteristics [13]. Such approaches have been applied to robotic fingers, including a compact continuously variable active transmission based on a four-bar linkage [9] and a variable-radius pulley for an underactuated finger [8]. However, active transmission adaptation requires additional actuation and reconfiguration components, increasing the mechanical and packaging requirements of the finger system.

Passive VT mechanisms reduce the need for additional transmission actuation by adapting the transmission ratio according to the applied load or mechanical state, offering advantages in compactness and fast responsiveness [14]. Passive transmission adaptation has also been demonstrated in robotic fingers and hands through load-sensitive cable-driven transmissions, drum-type CVTs, and elastomeric passive transmissions [10]–[12]. Nevertheless, when variable-transmission functionality is extended to multi-DoF robotic fingers, each DoF requiring transmission adaptation generally requires its own transmission-related mechanical elements and corresponding installation space. Consequently, although active and passive VT architectures differ in how transmission adaptation is realized, both can incur increasing mechanical and packaging burdens when VT functionality is extended across multiple DoFs in compact robotic fingers.

In the human hand, the metacarpophalangeal (MCP) joint possesses a parallel two-DoF architecture consisting of flexion-extension (FE) and abduction-adduction (AA) [15]. These 2-DoFs are functionally differentiated and therefore impose different performance requirements. This functional differentiation provides an opportunity to design robotic hands according to the role of each DoF rather than assigning identical transmission characteristics across all DoFs.

Based on this observation, we present the DoF-Specific TrANsmission Differentiation-based passive CVT-embedded MCP (STAND-MCP) mechanism, in which passive variable-transmission functionality is embedded directly within the MCP joint structure. The joint-integrated architecture selec-

JaeHyung Jang and Jee-Hwan Ryu are with the Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, South Korea. (e-mail: jhjang.kd@kaist.ac.kr; jhryu@kaist.ac.kr)

TABLE I COMPARISON OF VARIABLE-TRANSMISSION MECHANISMS APPLIED TO ROBOTIC FINGERS.

WorkReported Transmission VariationTransmission TypeAdaptationAdditional VT ActuatorVT IntegrationVT-Adapted DoFs / Motion DoFs**
Jeong et al. [7]6.9× (speed) / 11.6× (torque)DiscreteActive1Actuator-side1 / 1
Spanjer et al. [8]N/R*ContinuousActive1Actuator-side1 / 1
Chung et al. [9]2.13×ContinuousActive1MCP-joint integrated1 / 1
Phlernjai et al. [10]9.1×DiscretePassive0Actuator-side1 / 1
Matsushita et al. [11]2-3×ContinuousPassive0Actuator-side1 / 1
O'Brien et al. [12]2.88×ContinuousPassive0Actuator-side1 / 1
STAND-MCP (ours)4.19× (max) / 3.63× (mean)ContinuousPassive0MCP-joint integrated1 / 2
  • N/R indicates that a quantitative transmission-variation ratio was not explicitly reported in the corresponding study; reported transmission variations follow the transmission-performance metrics defined in the respective studies.

** VT-Adapted DoFs / Motion DoFs represent the number of functional motion DoFs incorporating VT relative to the total functional motion DoFs per finger, excluding internal transmission-reconfiguration DoFs.

tively provides force-responsive transmission adaptation to the FE pathway while retaining direct transmission for AA, thereby avoiding an additional variable-transmission element in the AA pathway.

Table I compares representative variable-transmission mechanisms applied to robotic fingers in terms of transmission characteristics, adaptation requirements, integration strategy, and the functional motion DoFs to which variable-transmission is applied. Among the representative finger-level variable-transmission mechanisms considered in the comparison, variable-transmission is applied to the single functional motion DoF of each finger, whereas the STAND-MCP preserves two functional motion DoFs while selectively applying variable-transmission only to flexion. Furthermore, the passive CVT is integrated directly within the MCP joint and requires no additional actuator for transmission adaptation. This combination of DoF-selective transmission adaptation and joint-integrated implementation reduces the transmission-related mechanical and packaging burden associated with introducing VT into a multi-DoF finger architecture.

To realize this architecture within the limited MCP joint volume, an output-side passive CVT based on a moving-pulley mechanism is introduced. The moving pulley is incorporated directly into the MCP transmission structure and changes its position according to wire tension, thereby continuously varying the FE moment arm and transmission ratio without additional sensing or active mode control.

This architecture addresses the mechanical and packaging burden associated with extending variable-transmission functionality to multi-DoF robotic fingers through two complementary features: selective transmission adaptation and joint-integrated implementation. Passive CVT functionality is applied to flexion, where a wide force-speed operating range is required, while abduction-adduction retains direct transmission, and the transmission-reconfiguration components are integrated directly within the MCP joint through the moving-pulley mechanism. The resulting STAND-MCP mechanism is theoretically and experimentally validated, demonstrating force-responsive adaptation of the FE transmission ratio, expansion of the flexion force-speed operating range, and coupled FE-AA motion within a compact 2-DoF MCP mechanism.

The remainder of this paper is organized as follows. Section II introduces the design concept and working principle of the STAND-MCP. Section III presents the theoretical modeling of the underactuated mechanism, including bilateral wire kinematics, the flexion-specific passive CVT, passive exten-

sion, and condition-dependent motion generation. Section IV describes the mechanical design and parameter selection of the proposed mechanism. Section V experimentally validates the transmission kinematics and force-responsive transmission behavior of the proposed passive CVT. Section VI demonstrates the applicability of the mechanism to dexterous robotic manipulation. Finally, Section VII concludes the paper and discusses future research directions.