Manuscript Offprint

arXiv:2609.00960

Conditional Flow Matching for Cross-Field MRI Harmonisation

Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring, Efe Ilicak

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Baris Imre¹, Aram Salehi²,³, Levente Baljer⁴, Andrew Webb³,⁵, Marius Staring¹, Efe Ilicak¹

¹ Division of Image Processing, Department of Radiology, Leiden University Medical Center

² Department of Human Genetics, Radboud University Medical Center

³ Department of Radiology, Leiden University Medical Center

⁴ Department of Neuroimaging, King's College London

⁵ Department of Bioengineering, University of Illinois

Abstract. Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task 3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.

Keywords: Conditional Flow Matching · MRI Field Translation · Generative Models

1 Introduction

Magnetic resonance imaging is central to neuroimaging. Typical MRI examinations consist of weighted images, as opposed to quantitative maps, that depend on tissue properties as well as acquisition settings. This makes images hard to compare across sites and hardware, hindering the reproducibility and the pooling of data for large studies.

B. Imre et al.

Figure

Fig. 1. The overall training architecture. Training is split into three stages, shown here as (1), (2), (3). In the pretraining stage the source (x0x_0) is a degraded copy of the target (x1x_1), since this cohort is unpaired; the network learns to restore it. In the second and third stages we continue with paired training. In the third stage, adversarial refinement, a discriminator judges the outputs of our CFM model and supplies an adversarial loss. The source field ss, target field τ\tau, and the timestep tt are embedded and injected through FiLM. During training the network predicts a velocity that transports the source towards the target; at inference this velocity is integrated over several steps.

Field strength heavily contributes to the signal-to-noise ratio and the clinically achievable spatial resolution, and shifts tissue contrast. The same subject can look different at different fields, even for the same protocol. Translating a scan from one field to another would put these images on common ground.

The MRIxFields2026 challenge poses this as cross-field MRI translation across five field strengths and three contrasts. There are three tasks. Task 1 maps any field up to 7T, Task 2 maps 0.1T up to any higher field, and Task 3 demands a single model that translates between any directed pair of fields. In this paper we mainly focus on Task 3. We propose a conditional flow matching method that bridges the source slice to the target with a time-dependent velocity field, conditioned on the timestep and the source and target field strengths through FiLM, with the three contrasts stacked as input channels. The unified model is trained in three stages: a degradation-bridge pretraining that learns a restoration prior from unpaired data, a cross-field finetuning over all directed pairs, and an adversarial refinement that sharpens the output.