arXiv:2609.01554cs.CVSep 2026

Manuscript Offprint

arXiv:2609.01554

BS: Take the Hint - Interactive Multitracer PET/CT Lesion Segmentation with a Scribble-Conditioned ResEnc U-Net

Marven Sherif, Amgad Elmasry, Youssef Ghazal, Ayman Elghotni

Marven Sherif 1^{1}, Amgad Elmasry 1^{1}, Youssef Ghazal 1^{1}, and Ayman Elghotni 1^{1}

Brightskies, Egypt

{marven.sherif,amgad.elmasry,youssef.ghazal,ayman.elghotni}@brightskiesinc.com

Abstract. Automated lesion segmentation in whole-body PET/CT is complicated by the variety of physiological tracer uptake patterns and by the differing appearance of lesions across tracers. The autoPET/CT V challenge addresses this by making segmentation interactive: user scribbles marking foreground and background are supplied alongside the image, and the algorithm is expected to exploit them. We present our submission, a scribble-conditioned residual encoder U-Net operating on four input channels – CT, PET, and a sparse scribble map for each of foreground and background. The network is initialised from the autoPET-III winning weights and extended from two to four input channels, with the two scribble channels zero-initialised so that the pretrained representation is preserved exactly at initialisation. Every model is fine-tuned per fold from the corresponding autoPET-III fold checkpoint, so that no validation case is seen during pretraining. PET intensities are normalised against a per-scan aorta blood-pool reference derived from a CT segmentation, which removes tracer- and centre-specific scaling without requiring lesion labels. At inference the five fold models are ensembled by averaging their softmax outputs per sliding-window patch, before Gaussian-weighted stitching. On the challenge's five-fold split, with each fold evaluated on its own validation cases, mean Dice is 0.554 and mean lesion-level F1 is 0.528 without scribbles, rising to 0.751 and 0.733 after five correction rounds. About 85% of that gain follows the first scribble, and the spread between fold models narrows five-fold over the same rounds, so interaction largely compensates for how well or badly a given model segments unaided.

Keywords: autoPET challenge · Interactive segmentation · PET/CT

1 Introduction

Positron emission tomography combined with computed tomography (PET/CT) is central to oncological staging and therapy response assessment, and quantitative read-out of tumour burden requires lesion segmentation. Manual delineation of whole-body studies is slow and subject to inter-reader variation, which motivates automated methods.

M. Sherif et al.

The autoPET challenge series [11], built on a publicly released whole-body PET/CT cohort with manual lesion annotations [6–8], has driven progress on this task. Its fifth edition (autoPET/CT V) differs from the earlier editions in two respects. First, it is multitracer: the cohort contains both 18{}^{18}F-FDG and 68{}^{68}Ga/ 18{}^{18}F-PSMA studies, whose physiological uptake patterns differ substantially, so that a model tuned to one tracer does not transfer to the other without care. Second, and centrally, the task is interactive: for each study the challenge supplies user scribbles that mark lesion (foreground) and non-lesion (background) voxels, and the algorithm is expected to use them. The clinically relevant question is therefore not only how well a model segments unaided, but how reliably it responds when a reader points at what it got wrong.

This paper describes our submitted algorithm. We treat the scribbles as two additional input channels to a three-dimensional residual encoder U-Net, initialise from the autoPET-III winning solution of Rokuss et al. [1], and fine-tune on the challenge data. We report five-fold cross-validation results over successive interactive correction rounds, which show that segmentation quality improves consistently as scribbles accumulate, most of the gain arriving with the first scribble.