A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Rafi Ibn Sultan1, Chengyin Li2, Yiannos Demetriou1, Ahmed I. Ghanem2,3, Joshua P. Kim2, Justine Cunningham2, Hassan Bagher-Ebadian2,4,5,6, Dongxiao Zhu1,7, and Kundan S. Thind2

1Department of Computer Science, Wayne State University, Detroit, MI, 48202, USA 2Department of Radiation Oncology, Henry Ford Health, Detroit, MI, 48202, USA 3Department of Clinical Oncology, Alexandria University, Alexandria, 21526, Egypt 4Department of Radiology, Michigan State University, E. Lansing, MI, 48824, USA 5College of Osteopathic Medicine, Michigan State University, E. Lansing, MI, 48824, USA 6Department of Physics, Oakland University, Rochester, MI, 48309, USA 7Institute for AI and Data Science, Wayne State University, Detroit, MI, 48202, USA

Corresponding author: Rafi Ibn Sultan, Department of Computer Science, Wayne State University, Detroit, MI, 48202, USA. E-mail: rafis@wayne.edu.

Abstract

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The task is inherently difficult because the LAD is extremely small, exhibits poor soft-tissue contrast, and varies substantially across patients. Even manual contours show limited inter-observer agreement on non-contrast CT, underscoring the ambiguity of the vessel boundaries.

Purpose: To develop a transformer-based segmentation framework that enhances LAD delineation in low-contrast, imbalanced CT using local-global context modeling and uncertainty-guided optimization.

Methods: We propose NA-UNETR, a 3D transformer-based segmentation model with Neighborhood Attention (NA) and Dilated NA (DiNA) blocks that jointly capture fine structural detail and long-range context. To address the limited availability of annotated LAD artery data, the model is pretrained on 1,000 CTA volumes representing general coronary anatomy and then fine-tuned using a parameter-efficient adaptation strategy on 20 free-breathing institutional CT scans of the LAD artery. A composite Dice–Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Preprocessing included intensity clipping, contrast enhancement, and artery-centric sampling, and postprocessing refined morphology.

Results: NA-UNETR achieved comparable performance to SOTA with improved efficiency and boundary properties. It reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, while showing the strongest boundary accuracy among all models and demonstrating improved geometric and centerline stability. On ImageCAS, it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed to performance stability and boundary precision.

Conclusions: NA-UNETR effectively balances local precision and global context, enabling accurate segmentation of thin, low-contrast LAD structures. Its integration of Neighborhood Attention, uncertainty-weighted loss, and LoRA-based fine-tuning demonstrates a robust and computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

I. Introduction

Radiation-induced heart disease (RIHD) is a growing concern in thoracic oncology, particularly for patients undergoing radiotherapy for lung, esophageal, or breast cancers 1, 2. RIHD includes both acute (e.g., pericarditis) and late effects (e.g., coronary artery disease, heart failure, arrhythmias), with risks manifesting earlier than expected, sometimes within 5 years of treatment, and persisting for decades 3. Among cardiac substructures, the Left Anterior Descending (LAD) artery is especially susceptible to radiation injury due to its location along the anterior interventricular groove and its role in supplying the anterior wall and most of the left ventricle 4. Radiation doses as low as 10 Gy have been linked to increased coronary artery calcification and ischemic events 5, while a mean heart dose greater than 10 Gy or a LAD volume receiving 15 Gy (V15Gy) exceeding 10 percent significantly increase the risk of major adverse cardiac events in non-small cell lung cancer patients 6.

Despite its clinical significance, the LAD is rarely segmented in routine radiotherapy workflows, which often rely on whole-heart dose–volume metrics 7, 8 such as those recommended by QUANTEC 9. These measures treat the heart as a uniform organ, potentially overlooking radiosensitive substructures. Studies indicate that dose to regions like the LAD 10, left ventricle 11, and left atrium 12 may better predict long-term morbidity than global heart dose. However, LAD delineation on standard free-breathing, non-contrast, non–ECG-gated planning CT remains extremely challenging due to its small caliber, variable course, and limited soft-tissue contrast 13, 14, 15, 16. The artery often appears faint with ill-defined boundaries and is further obscured by motion artifacts 17. Inter-observer studies report manual coronary artery Dice scores ranging from 0.10 to 0.53 on non-contrast CT 18, underscoring the substantial disagreement even among expert readers.

Several automatic segmentation strategies have been explored for LAD segmentation. Atlas-based methods are simple to implement but depend on image registration and perform poorly on the LAD, with reported Dice Similarity Coefficients (DSC) of 0.09–0.27 19, 20, 21, 17. Their inability to capture anatomical variability or resolve small, low-contrast structures limits their usefulness. Deep learning approaches generally perform better but still struggle on non-contrast CT: U-Net 22 and nnU-Net 23 achieve only about 0.21 DSC for the LAD 24, 25, far lower than the values above 0.85 commonly reported for cardiac chambers and large vessels. This disparity stems from the intrinsic difficulty of LAD delineation on non-contrast CT, where faint boundaries, low contrast, and motion artifacts limit the visual cues available for supervision. These factors, together with the limited availability of expert-labeled data, create a pronounced small-data bottleneck for coronary substructure segmentation. Multi-modal strategies using MRI or contrast-enhanced CT improve visibility 9, 26, 27 but remain impractical for standard radiotherapy and diagnostic workflows.

While this work focuses on the LAD, insights from broader coronary artery segmentation remain relevant since the underlying challenges often overlap. Most pipelines employ convolutional neural networks (CNNs), including U-Net and its variants 28, 29, 30, or enhanced designs with attention and multi-scale fusion 31, 32, as well as PSPNet-based 33 and ensemble approaches 34. However, CNNs struggle to capture long-range anatomical dependencies that are essential for maintaining vessel continuity 35, 36, 37. Transformer-based models address this limitation by modeling global context, allowing relationships between distant structures to be learned jointly. Yet, transformer-based approaches have rarely been explored for coronary artery segmentation and, to our knowledge, have not been evaluated for LAD segmentation in non-contrast, free-breathing planning CT, an especially difficult setting with limited annotated data.

We present NA-UNETR, a 3D transformer-based segmentation framework developed to address the small-data regime inherent to LAD segmentation. Its design integrates Neighborhood Attention (NA) 38 for localized feature extraction within a global transformer backbone, enabling improved representation of thin and low-contrast anatomy. To mitigate class imbalance and improve thin-structure detection, we incorporate artery-focused patch sampling and a composite loss that combines Dice-Focal and boundary-aware Hausdorff losses with homoscedastic uncertainty weighting. Crucially, NA-UNETR employs a two-stage transfer learning strategy: pretraining on a large CCTA dataset followed by parameter-efficient fine-tuning using LoRA on clinically curated planning CTs. This approach directly addresses the scarcity of expert-labeled LAD data and provides a principled solution to the small-data bottleneck. Together, these innovations yield a segmentation framework suited for substructure-level cardiac analysis in thoracic radiotherapy.

References (18)