Manuscript Offprint

arXiv:2608.27484

CareGraph: An Auditable Hybrid AI Framework for Evidence-Grounded Personalized Longitudinal Health Intelligence

Pratik Ghawate, Tanvi Patil

Abstract

Health information already exists across laboratory portals, electronic health records, medication lists, symptoms, lifestyle reports, and wearable devices, yet these sources rarely form a coherent and traceable explanation for an individual. CareGraph is proposed as an auditable hybrid AI framework and extensible backbone for evidence-grounded personalized longitudinal health intelligence. It transforms heterogeneous patient-specific records into prioritized trends, missing-context indicators, bounded next steps, clinician-discussion questions, and traceable explanations. Personalization denotes organization, prioritization, and interpretation of an individual's available evidence; it does not denote diagnosis, prognosis, treatment selection, or autonomous clinical decision-making. The architecture separates deterministic data-sufficiency and trend analysis, scenario-aware missing-context detection, patient-state assembly, provenance-oriented graph construction, schema-constrained language-model synthesis, evidence validation, safety transformation, and release gating. Independently seeded synthetic development, validation, and held-out cohorts contained 400 patients each. A frozen ordinary-least-squares trend rule with an explicit sufficiency gate achieved held-out accuracy 0.827, macro-F1 0.837 (95% CI 0.819–0.854), and insufficient-data F1 0.974. Schema-aligned missing-context detection achieved strict held-out micro-F1 0.815 versus 0.318 for the legacy detector, and safety ruleset v1.2 achieved precision 1.000, recall 0.950, and F1 0.974 on a held-out authored benchmark. A graph-required 80-patient engineering audit produced 79 AI syntheses and 78 presentation outputs with no fallback; one output was blocked and one failed closed after an invalid evidence key. In a matched 56-patient comparison with an isolated monolithic GPT-5.6 baseline, CareGraph was faster (40.15 versus 49.62 s), shorter (661 versus 1,163 words), and more aligned with predefined longitudinal targets in exploratory lexical checks, while the monolithic baseline used fewer total tokens and cited more direct raw-record evidence. The graph audit verified provenance integrity and deterministic retrieval; incremental graph contribution to generated content is reserved for a dedicated paired evaluation. These results establish CareGraph as a technically validated foundation for a new class of patient-facing and clinician-facing personalized health-intelligence systems within a controlled synthetic setting.

Keywords: agentic artificial intelligence, biomedical informatics, evidence grounding, health knowledge graphs, longitudinal health data, personal health informatics, personalized health intelligence, responsible AI, synthetic health data.

1 Introduction

Longitudinal health information is distributed across laboratory portals, electronic health records, medication lists, symptoms, vital signs, lifestyle reports, family and medical history, and wearable devices. The central systems problem is therefore not simply data availability; it is fragmentation. Individuals and clinicians often see isolated measurements without a coherent account of what changed over time, what information is missing or contradictory, what deserves discussion, and where each statement came from. A useful health-intelligence system must provide that synthesis without hiding calculation, uncertainty, provenance, or release controls.

Large language models (LLMs) demonstrate substantial medical question-answering capability [4, 5], but fluency can obscure unsupported claims, omissions, and overconfident recommendations [6]. CareGraph addresses this limitation by treating personalized health intelligence as a systems problem rather than a one-pass prompting problem. Deterministic and rule-based stages calculate and qualify patient-specific evidence; an optional LLM converts only authorized evidence into a constrained schema; and a separate safety stage validates references and controls release. The objective is not autonomous clinical decision-making, but an intelligible layer that helps a person or clinician understand longitudinal patterns and prepare better questions.

CareGraph is designed as an extensible health-intelligence backbone rather than a closed application. New laboratory, EHR, medication, symptom, lifestyle, or wearable adapters can be normalized into the same patient state and authorized evidence registry, while downstream trend logic, provenance, synthesis, and release contracts remain stable. In the envisioned use, heterogeneous health records can be connected to the framework and transformed into a concise explanation of what changed, what context is absent or conflicting, which issues merit discussion, and how every generated statement traces back to source data. The current study evaluates the technical foundation for that broader system vision.

The evaluation program progresses from component validity to end-to-end system behavior. Independently seeded development, validation, and held-out cohorts assess frozen trend and missing-context methods; a separate authored benchmark evaluates safety rules; a 400-patient audit verifies graph provenance; an 80-patient engineering batch measures operational reliability and release behavior; and a matched 56-patient comparison characterizes the trade-off between CareGraph and an isolated monolithic baseline. Together, these experiments test whether the proposed backbone can turn fragmented longitudinal records into focused, inspectable, and safety-governed personalized health intelligence.

The paper makes seven contributions:

  • An extensible hybrid AI framework that separates multi-source data integration, deterministic evidence generation, graph-based provenance, constrained synthesis, safety review, and presentation gating.

  • A frozen trend protocol with independent development, validation, and held-out cohorts, an explicit data-sufficiency gate, and class-, scenario-, and biomarker-level reporting.

  • A schema-aligned missing-context detector with exact versioned canonicalisation, backward-compatible legacy output, and an audit of generator-ground-truth limitations.

  • A transparent safety ruleset evaluated on separate authored development and held-out adversarial examples, including retained false-negative analysis.

  • A 400-patient graph retrieval and provenance audit that separates structural lineage verification from unproven graph-specific content benefit.

  • An 80-patient end-to-end synthesis audit reporting completion, evidence validity, latency, prompt drift, safety interventions, one fail-closed invalid-key error, and one apparent false-positive safety block.

  • A matched 56-patient final-prompt comparison with an isolated monolithic baseline, reporting paired generation efficiency, output breadth, evidence use, and exploratory longitudinal-coverage checks.

References (18)