Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

Yuang Wang, Shuo Wang, Changyu Chen, Dufan Wu, Pengfei Jin, Yunqiang An, Yang Gao, Bin Lu, Dongrui Dai, Muge Du, Yan Yan, Dong Li, Liang Li, Li Zhang, Zhiqiang Chen

Yuang Wang, Shuo Wang, Changyu Chen, Dufan Wu, Pengfei Jin, Yunqiang An, Yang Gao, Bin Lu, Dongrui Dai, Muge Du, Yan Yan, Dong Li, Liang Li, Li Zhang, Zhiqiang Chen

Abstract— Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.

Index Terms— 4D cardiac CT, registration, right coronary artery

Yuang Wang, Shuo Wang, Changyu Chen, Dongrui Dai, Muge Du, Liang Li, Li Zhang and Zhiqiang Chen are (were) with the Department of Engineering Physics, Tsinghua University, Beijing 100084, China.

Dufan Wu is with the Department of Radiology, The Ohio State University, 2050 Kenny Rd, Columbus, OH 43221, Ohio, USA.

Pengfei Jin is with Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, 399 Revolution Dr, Somerville, 02145, Massachusetts, USA.

YunQiang An, Yang Gao, Bin Lu are with the Department of Radiology, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.

Yan Yan and Dong Li are with the Department of Radiology, Tianjin Medical University General Hospital, Tianjin, China.

Send correspondence to Li Zhang (zli@mail.tsinghua.edu.cn) and Zhiqiang Chen (czq@mail.tsinghua.edu.cn)

I. INTRODUCTION

CARDIAC computed tomography (CT) is an important noninvasive imaging technique for visualizing cardiac anatomy and assessing cardiovascular diseases. However, real cardiac motion remains inaccessible. Clinical multiphase reconstructions generally provide acceptable image quality in phases close to end-diastole (ED) or end-systole (ES), but in other phases may exhibit severe motion artifacts, particularly in the right coronary artery (RCA) region.

This poses a common challenge in constructing 4D cardiac CT datasets that serve as pseudo ground truth for 4D cardiac CT imaging research. Pseudo ground truth is typically required in simulation studies for CT system design, quantitative evaluation of image reconstruction methods, and supervised training of deep learning-based reconstruction approaches.

Previous studies typically constructed pseudo ground truth using four categories of strategies. The first category [1] directly uses clinical multiphase reconstructions as pseudo ground truth; however, many phases exhibit motion artifacts. The second category [2], [3] manually designs deformation fields around the RCA centerline and applies them to well-reconstructed volumes; however, such deformation fields are generally restricted to RCA and difficult to propagate to other cardiac structures. The third category employs digital phantoms such as the 4D extended cardiac-torso (XCAT) phantom [4], which provide continuous-time cardiac motion but may simplify anatomical details compared with real patients. The fourth category [5] extracts cardiac motion from XCAT and transfers it to well-reconstructed clinical volumes; however, cardiac motion diversity may be limited by XCAT.

Since clinical multiphase reconstructions often suffer from motion artifacts but provide patient-specific cardiac anatomy and cardiac motion, one may consider reducing these artifacts using established motion-compensated reconstruction methods and subsequently using the resulting sequences as pseudo ground truth. However, reconstruction methods are generally unsuitable for this purpose. Most classical motion estimation and motion-compensated reconstruction (ME-MCR) methods [6], [7] and motion-aware networks [1], [8] require raw projection data, which are often unavailable due to proprietary restrictions. This limits their applicability for constructing large-scale datasets. Reprojection approaches [3],

GENERIC COLORIZED JOURNAL, VOL. XX, NO. XX, XXXX 2023

[9] and post-processing networks [2], [10] can operate directly on clinical multiphase reconstructions and reduce motion artifacts. However, they typically produce the same number of cardiac phases as the multiphase reconstruction. The temporal resolution of such outputs may be insufficient for developing cardiac CT systems [11] and reconstruction algorithms that aim to achieve substantially higher temporal resolution than clinical multiphase reconstructions.

In this work, we propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence directly from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the cardiac phase with minimal motion artifacts as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction to produce deformation fields. Time-continuity is achieved by interpolating deformation fields for non-reference phases to arbitrary times.

In registering the reference phase to each non-reference phase, directly applying existing registration methods may be suboptimal. Image-domain registration methods, including both conventional registration methods [12], [13] and learning-based approaches [14], [15], may fail to capture RCA motion in the non-reference phases where the RCA suffers from severe motion artifacts or exhibits large displacement relative to the reference phase. Centerline-focused registration methods [16] can provide acceptable motion estimation of the RCA centerline, but they do not explicitly preserve RCA shape and generally cannot capture chamber and aorta motions.

In each registration, to capture the motion of both the RCA and other cardiac structures, CMGR regularizes the RCA masks for both reference and non-reference phases and incorporates them into image-domain registration. Specifically, RCA masks are regularized for connected main trunks, reasonable shape, plausible centerlines and consistent branches. These masks are then incorporated into a proposed multi-resolution registration strategy for producing a deformation field that captures RCA motion and preserves RCA geometry. An additional deformation field that captures the remaining cardiac motion without distorting the RCA is subsequently produced using our proposed RCA protection strategy. Composing the two deformation fields yields a whole-heart deformation field that generally preserves cardiac motion from clinical multiphase reconstructions.

CMGR is compared with representative image-domain registration approaches. Through extensive experiments, CMGR demonstrates superior capability and stability in capturing RCA motion and providing reasonable RCA shape, and shows competitive performance in capturing whole-heart motion. We also show CMGR's capability in reducing motion artifacts from clinical multiphase reconstructions. In addition, we demonstrate that intermediate CMGR frames generally provide plausible transitions between discrete cardiac phases.

The main contributions are summarized as follows:

  • We propose CMGR for 4D cardiac CT dataset construction. To the best of our knowledge, CMGR is the first

approach to produce motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequences from clinical multiphase reconstructions without requiring raw projection data.

  • To the best of our knowledge, CMGR is the first registration approach that explicitly regularizes RCA masks and incorporates them into image-domain registration. This enables CMGR to capture the motion of both the RCA and other cardiac structures.

  • Through extensive experiments, we demonstrate CMGR's strong capability in capturing RCA motion and providing reasonable RCA shape, as well as its competitive performance in capturing whole-heart motion. We also show that CMGR is able to reduce motion artifacts from clinical multiphase reconstructions and that intermediate CMGR frames generally provide plausible transitions between discrete cardiac phases.