Abstract

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression without explicit correspondence constraints. We introduce SCoPE-Reg, combining state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and µ-RegPro, SCoPE-Reg yields mean target registration errors of 0.73 mm and 2.27 mm against 1.24 mm and 2.63 mm for the state of the art (SOTA), reduces peak error on CAMUS by 56% below SOTA (12.5 → 5.5 mm), and registers 100% and 80% of frames within 3 mm. On CAMUS at 128² it retains the lowest error at increasing pose-perturbation magnitude. It holds 6.49 M parameters independent of resolution, sustaining 51 FPS at 512². SCoPE-Reg establishes a SOTA in rigid ultrasound SVR: by coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, it becomes viable at native acquisition resolution during intervention, where prior methods trade accuracy, reliability, or frame rate against one another. Supplementary code provided and will be open-sourced upon acceptance.

1. Introduction

Ultrasound (US) provides portable, real-time imaging without ionizing radiation and is well suited to image-guided interventions. Intraoperative 2D US, however, captures limited planar anatomy without a known pose relative to a 3D reference. 2D–3D US registration resolves this ambiguity by mapping live 2D views into 3D volumetric context, mitigating operator dependence and enabling target transfer across e.g. cardiac frame-to-volume fusion, targeted prostate biopsy, hepatic tumor ablation, and intraoperative margin assessment [19, 31, 49, 52]. These settings require millimetre accuracy at acquisition frame rates. Hardware tracking supplies the pose but adds equipment, calibration, and line-of-sight constraints; image-based slice-to-volume registration (SVR) instead estimates alignment from image content alone. We consider rigid SVR, which applies when deformation is limited and initializes deformable alignment.

Rigid US SVR is challenging because a single frame contains only partial anatomical information, and similar local structures may occur at multiple positions and orientations. Speckle, shadowing, and view-dependent appearance further confound correspondence estimation [14, 38, 52]. These ambiguities induce a non-convex objective and limit the capture range of iterative methods. Learning-based approaches extend the effective capture range through one-shot pose estimation [4, 39], sequential refinement [28], feedback-guided attention [21], or patient-specific test-time optimization [15]. All must relate features across different spatial domains: a 2D slice and a 3D volume.

Existing methods adopt three recurring strategies for slice-volume interaction and pose estimation. Direct-regression architectures, including one-shot and iterative variants, map fused features to transformation parameters, often incorporating differentiable resampling or multi-level correlation [19, 49]. Because pose estimation is not explicitly coupled to spatial correspondences, such architectures can exhibit large outliers despite low mean errors. Fully connected heads depend on feature resolution. While attention-based methods model slice-volume interaction [31, 56], dense cross-attention scales with the

¹Institute for AI in Medicine (IKIM), University Hospital Essen, Girardetstraße 2, 45131 Essen, Germany ²Cancer Research Center Cologne Essen (CCCE), University Medicine Essen, Hufelandstraße 55, 45147 Essen, Germany ³RACOON Study Group, Site Essen, Essen, Germany ⁴Department of Physics, Technical University Dortmund, Otto-Hahn-Straße 4a, 44227 Dortmund, Germany ⁵German Cancer Consortium (DKTK), Partner Site Essen, Hufelandstraße 55, 45147 Essen, Germany ⁶Medical Faculty and Faculty of Computer Science, University of Duisburg-Essen, 45141 Essen, Germany ⁷Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, USA product of slice and volume tokens—creating memory bottlenecks that limit scalability to low-resolution inputs. Correspondence-based methods impose an explicit geometric model after matching [4, 10]; EUReg [44], for example, predicts a cross-dimensional flow field but estimates the pose with learned regression heads. Their performance depends on the reliability and coverage of the predicted matches. Effective rigid SVR therefore requires scalable cross-dimensional interaction, dense correspondence estimation, and geometrically coupled pose recovery.

By replacing quadratic cross-attention with linear state-space modeling and explicit regression with closed-form point alignment, slice-to-volume registration scales to high resolutions. To this end, we introduce SCoPE-Reg (Fig. 1), pairing a Correlation-Weighted Coordinate Decoder (CWCD) with a Weighted Kabsch Pose Solver (WKPS). CWCD uses State-Space Slice-Volume Fusion (SSVF) to model 2D–3D interaction with linear complexity, propagating the volume's coordinate grid through the same scan so that the recurrence itself yields dense 3D coordinates and spatial evidence weights. WKPS then solves the rigid transformation via closed-form weighted least-squares alignment [26, 27, 41], suppressing low-confidence regions. Coordinates and weights require no direct supervision, learning purely end-to-end from pose loss.

Contributions. Our contributions are threefold. (I) We introduce CWCD, which uses linear-complexity state-space fusion to predict dense 2D–3D coordinates and spatial evidence weights. (II) We recover rigid pose via parameter-free weighted Kabsch estimation, learning correspondence solely from pose supervision while allowing arbitrary input resolution without increasing complexity. (III) SCoPE-Reg advances SOTA on CAMUS [30] and μ\mu-RegPro [2], lowering mean error from 1.24 to 0.73 mm and 2.63 to 2.27 mm and peak error on CAMUS by 56%, while achieving high throughput at a minimal GPU memory footprint.