Beyond Representation Learning: A Systematic Study of Joint-Embedding Predictive Generation for 3D Brain MRI

Meng Zhou, Wenhao You, Yuxing Chen, Yueying Tian

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Joint-embedding predictive architectures (JEPAs) have primarily been developed for self-supervised representation learning. Denoising JEPA (D-JEPA) recently demonstrated strong generative capabilities on natural images, yet the applicability to 3D medical imaging remains unexplored. Building on the D-JEPA framework, we present Med-D-JEPA, a systematic adaptation and evaluation of joint-embedding predictive generation for 3D brain MRI. Med-D-JEPA operates on continuous latent tokens produced by a 3D KL-regularized adversarial variational autoencoder, and combines masked context prediction, representation-level alignment, per-token diffusion, and iterative next-set-of-token sampling. We evaluate unconditional and class-conditional generation quality on BraTS2019 and OASIS-1 datasets; downstream classification utility; and preliminary whole-tumor segmentation on BraTS2020. Across different generation settings, Med-D-JEPA achieves superior or competitive performance compared to several strong baselines on fidelity and diversity metrics. Compared to training with real samples, Med-D-JEPA-based synthetic pre-training improves classification AUC from 0.63 to 0.85 on BraTS2019 and from 0.78 to 0.87 on OASIS-1. In the segmentation study, pretraining on Med-D-JEPA samples improves Dice from 0.74 to 0.80 and reduces HD95 from 13.40 to 9.56 mm. These findings establish joint-embedding predictive generation as a promising direction for 3D medical image synthesis and encourage further research in this direction.

1. Introduction

3D magnetic resonance imaging (MRI) plays a central role in neuroimaging, supporting anatomical assessment, tumor diagnosis, treatment planning, and longitudinal monitoring [4]. However, the development of reliable learning-based systems for volumetric MRI remains constrained by limited cohort sizes, costly expert annotations, hetero-

Figure

Figure 1. Synthetic MRI volumes generated by Med-D-JEPA. Left to right: orthogonal views of a 128³ volume on BraTS2019, a 128³ volume on OASIS-1 a 256³ volume on BraTS2020.

geneous acquisition protocols, and restrictions on sharing patient data [37, 53]. Synthetic medical image generation has therefore emerged as a promising approach for augmenting scarce datasets, reducing reliance on repeated data acquisition, and supporting the development of data-intensive learning systems [21]. Nevertheless, visual realism alone does not guarantee that synthetic volumes are useful [32]. Effective medical image generation models must also preserve 3D anatomical coherence, represent relevant pathological characteristics, capture sufficient population diversity, and ultimately provide measurable benefits to downstream clinical tasks. Existing 3D medical image generation models are predominantly based on generative adversarial networks (GANs) [23, 33, 46, 47], diffusion models [16, 21, 29, 40, 51], or autoregressive (AR) models [42, 49, 57, 58]. GAN-based approaches enable efficient one-pass volume synthesis, but often suffer from unstable optimization and limited distributional coverage [20]. Diffusion models provide stable training and high sample quality, but even in latent space, 3D generation requires substantial denoising efforts over volumetric representations, resulting in considerable inference latency and nontrivial memory demands [58]. Autoregressive methods offer an alternative by factorizing the data distribution over a sequence of latent tokens, but they mostly rely on vector-quantized representations, introducing irreversible quantization loss [36]. Moreover, conventional token-by-token sampling can become prohibitively slow as the number of 3D latent tokens increases. These trade-offs motivate a framework that combines continuous latent representations

Figure

Figure 2. Overview of Med-D-JEPA. A 3D KL-VAE-GAN first compresses MRI volumes into continuous latent tokens. Med-D-JEPA then jointly optimizes a JEPA prediction loss and a per-token diffusion loss, with optional class conditioning. During inference, it progressively samples sets of latent tokens and decodes the completed 3D latent grid into a synthetic MRI volume. “reps.” denotes representations, hatched cells indicate masked locations, and orange highlights an example target location.

with efficient, semantically structured token generation.

Joint-embedding predictive architectures (JEPAs) have recently emerged as an effective paradigm for self-supervised representation learning [2, 6, 12]. Rather than reconstructing every input detail in pixel space, JEPA predicts the representations of unobserved targets from visible context. Consequently, most existing JEPA research has focused on learning transferable image or video representations instead of generating new samples. Denoising with a Joint-Embedding Predictive Architecture (D-JEPA) [15] recently bridged these two directions by formulating masked latent prediction as generalized next-token prediction and employing the diffusion objective to model continuous token distributions, and demonstrated strong performance on natural images. Nevertheless, whether this generative formulation remains effective in data-scarce 3D medical imaging has not been systematically investigated.

Extending D-JEPA to volumetric MRI raises several questions specific to its predictive generative formulation. First, can D-JEPA effectively model 3D latent tokens while preserving anatomical and pathological consistency across anatomical planes? Second, can its generative performance be maintained when it is trained on 3D medical imaging datasets that are substantially smaller than the natural-image datasets? Third, does the joint-embedding prediction objective improve 3D image generation, and how does generalized next-set-of-token sampling trade generation quality against inference cost?

Motivated by these challenges, we present Med-D-JEPA, a volumetric adaptation and systematic evaluation of D-JEPA for 3D brain MRI generation. As illustrated

in Fig. 1, Med-D-JEPA supports diverse generation settings spanning tumor-centered ROIs and whole-brain volumes, FLAIR and T1-weighted MRI contrasts, and resolutions from 1283128^3 to 2563256^3 voxels. Med-D-JEPA compresses each MRI volume into a grid of continuous latent tokens using a 3D KL-regularized adversarial variational autoencoder. We extend the context-target prediction mechanism to 3D latent patches and jointly optimize a JEPA prediction objective and a per-token diffusion objective. During inference, Med-D-JEPA predicts and samples multiple latent tokens at each AR step, providing an alternative to both sequential next-token generation and full-volume denoising. We evaluate Med-D-JEPA across three complementary brain MRI settings, assessing both generation quality and downstream utility in classification and segmentation. On BraTS2019, we investigate unconditional and HGG/LGG-conditioned generation and classification on tumor ROIs following prior studies [57, 58]. On OASIS-1, we evaluate unconditional and cognitive-status-conditioned generation and classification on whole-brain T1-weighted MRI following [48]. Finally, on BraTS2020, we investigate unconditional whole-brain MRI generation and conduct a preliminary segmentation study. Our contributions are summarized as follows:

  • We provide, to the best of our knowledge, the first systematic investigation of a D-JEPA-based generative framework for 3D medical imaging, extending continuous joint-embedding prediction from 2D natural images to 3D MRIs.

  • We develop Med-D-JEPA that combines a 3D KL-regularized adversarial variational autoencoder, joint-

embedding prediction, and per-token diffusion for unconditional and class-conditional brain MRI generation.

  • We conduct extensive experiments and evaluate Med-D-JEPA across three MRI datasets: BraTS2019, BraTS2020, and OASIS-1. The experiments validate the generalization across spatial scopes, resolutions, and imaging contrasts.

  • We show that Med-D-JEPA is a powerful alternative to conventional Diffusion and Autoregressive generation methods based on distributional fidelity and diversity, volumetric consistency, sampling efficiency, and downstream utility.