arXiv:2608.28838q-bio.BMAug 2026

Manuscript Offprint

arXiv:2608.28838

Reconstruction-Aware Cryo-EM Particle Picking

Riku Itsuji, Yuanhao Wang, Xingjian Li, Seonghui Min, Hideo Saito, Min Xu

Abstract

Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers.

1. Introduction

Cryo-electron microscopy (cryo-EM) has become a central technique for determining the structures of proteins and macromolecular assemblies at near-atomic resolution [24, 29, 64]. Most of these structures are solved by single-particle analysis (SPA), in which a large number of noisy 2D projections of many identical copies of the same molecule are combined into a single 3D density map [6]. The workflow first images the vitrified specimen into 2D micrographs, each containing projections of many particles frozen in random orientations. The particles located and extracted from the micrographs form the stack that 3D reconstruction consumes. This work addresses that middle stage, whose goal is to deliver a particle stack that supports a high-quality reconstruction.

Two properties of the data make this stage difficult. First, electron dose must be kept low to limit radiation damage, so the contrast between a particle and background is small. Second, high-contrast contamination such as ice crystals and carbon edges is present in the same micrographs and can be picked as false positives.

To obtain a usable particle set under these conditions, current practice decomposes the stage into three sub-tasks. Particle picking localizes candidates in each micrograph, as done by crYOLO [54], Topaz [4], CryoTransformer [11], and CryoSegNet [16]. Contamination removal masks these contaminated regions and discards the candidates that fall inside them, as in MicrographCleaner [39]. 2D classification groups the extracted particles into classes of similar projections, and a selection step such as CryoSift [40] rejects the non-particle classes.

Each of these sub-tasks performs well on its own, but optimizing them separately does not necessarily give a good 3D reconstruction. Particle picking, for instance, is usually scored by precision, recall, and F1 against expert-annotated coordinates, most often on CryoPPP [10], and the trade-off against false positives risks overlooking rare views. In a pipeline where contamination removal and 2D classification already remove outliers, a picker can tolerate false positives so that rare views are not missed.

The purified set is also a source of supervision for the picker. 2D classification is particularly informative here, because it groups similar views into classes and lets the decision be made on a class average rather than on a single noisy particle. The surviving particles can be mapped back to their micrographs and reused as pseudo-labels, which adapts the picker to the target data without manual annotation.

Only a few existing works tackle this combined setting. TranSPHIRE [42] and McSweeney et al. [28] close the loop by retraining the picker with feedback from 2D classification. Both select the classes with a heuristic or binary decision that cannot express the quality differences between classes. Neither removes high-contrast contamin

Preprint.

tion, which can survive to form coherent false-positive 2D classes.

We propose reconstruction-aware particle picking, a formulation in which detection and purification are designed jointly against downstream reconstruction quality rather than separately against 2D metrics. We instantiate it as a pipeline that assembles a state-of-the-art model for each sub-task and feeds the purified set back to the picker. The high-recall picker CryoTransformer [11] proposes candidates, MicrographCleaner [39] removes contamination, and CryoSift [40] scores the 2D class averages of the survivors on a continuous scale from 1.0 to 5.0. Finally, the purified set fine-tunes the picker, which re-picks every micrograph before the two purification stages run again.

We evaluate the pipeline on the four EMPIAR entries that form CryoTransformer's independent test set (EMPIAR-10081, 10093, 10345, and 10532), processing the full micrograph set of each entry rather than only the 300 micrographs annotated by CryoPPP. We judge it not by 2D detection metrics but by the final reconstruction resolution obtained from the stack it delivers. The pipeline improves on CryoTransformer, the picker it is built on, by 0.63 to 3.57 Å across the four entries, and gives the best resolution of any picker we compare.

Our contributions are summarized as follows:

• Reconstruction-aware formulation. We formulate particle picking, contamination removal, and 2D class selection as a single selection problem posed against downstream reconstruction, and evaluate it by reconstruction resolution rather than by 2D F1 against incomplete annotations; reconstruction is used for system-level evaluation, not as a direct training signal.

• A purification pipeline that outperforms existing pickers. We combine a high-recall picker with contamination masking and 2D class selection, and close the loop by re-training the picker on the purified particle stack. The pipeline gives the best reconstruction of any picker we compare.

• The best F1 is not the best reconstruction. Across the same pickers and entries, 2D detection scores do not reliably order the reconstructions. Agreement with 2D annotations is therefore only a partial guide, and we judge a selection by the map it delivers.

References (67)