arXiv:2608.29230cs.CVAug 2026

Manuscript Offprint

arXiv:2608.29230

Compact Snapshot Spectral Imaging with Calibration-Free Aperture Diffraction

Tao Lv, Quan Yuan, Shiqiao Li, Chenglong Huang, Linsen Chen, Chongde Zi, Shuming Wang, Xun Cao

Tao Lv ID^{ID}, Quan Yuan, Shiqiao Li, Chenglong Huang ID^{ID}, Linsen Chen ID^{ID}, Chongde Zi, Shuming Wang, Xun Cao ID^{ID}, Member, IEEE

Abstract—Snapshot Spectral Imaging (SSI) provides high-dimensional temporal-spatial-spectral observation to uncover intrinsic physical characteristics. However, its complex system and repetitive calibration requirements hinder edge applications. Here, we propose a compact, cost-effective, calibration-free SSI method, Aperture Diffraction Imaging Spectrometer (ADIS), which consists only of a diffractive lens with a binary mask and a Bayer-filtered sensor, requiring no additional physical footprint compared to standard RGB cameras. ADIS disperses and multiplexes wavelengths, mapping energy to distinct sensor locations, enabling full-resolution recovery from superpixel-level encodings. ADIS directly leverages theoretically computed PSFs to enable calibration-free spectral reconstruction, while tolerating lens-dependent variations across different optical configurations and bridging the gap between simulation and reality. To achieve SSI by solving a sparsely-constrained inverse problem, we introduce the Orthogonal Diffraction-Aware Unfolding Framework (ODAUF) with Voxel Shift Transformer (VST) for improved orthogonal diffraction perception. Integrating VST into ODAUF forms the efficient Orthogonal Diffraction-Aware Unfolding Voxel Shift Transformer (ODAUVST), delivering excellent recovery and reduced parameters. By elaborating on theory, systematic and comprehensive comparing, and demonstrating real SSI results, we validate the superiority of ADIS, achieving calibration-free full-resolution SSI within a commercial camera footprint.

Index Terms—Calibration-Free, Snapshot spectral imaging, Compact, Aperture Diffraction.

I. INTRODUCTION

Hyperspectral imaging has found extensive applications across various fields due to its inherent optical characteristics, which enable the detailed identification of physical and chemical properties. By sacrificing temporal resolution, hyperspectral imaging captures fine-grained spectral data at each spatial location, producing a hyperspectral image (HSI) that provides a rich representation of the spectral features in the observed scene. This additional spectral information is crucial for distinguishing materials with the same color but different compositions, thus enabling the differentiation of their physical and chemical properties. Snapshot spectral imaging (SSI) advances this capability further, aiming to capture the high-dimensional spectral description of a scene in a single exposure, thereby extending the perceptual capabilities beyond the human eyes [1]. It has found significant applications in fields such as industrial monitoring [2], astronomical observation [3], combustion dynamics [4], and cellular dynamics [5].

However, traditional SSI systems rely on specific optical components, such as dispersive optics (prism or grating), occlusion masks, multiple relay lenses, and an imaging lens, resulting in a large and complex form factor, limiting their practical application at the edge [6], [7], [8], [9]. Furthermore, the accurate characterization of dispersion and spatial encoding in such systems requires precise calibration, which must be repeatedly performed whenever the systems are disturbed [10].

In summary, the application of SSI at the edge faces two key limitations: (1) large and complex form factor; (2) the necessity for frequent recalibration. Although recent efforts have been made to miniaturize SSI systems based on diffractive optical elements (DOEs), calibration is still required to account for the modulation effects of the DOE across different spectral bands due to manufacturing challenges [11], [12]. Despite meticulous calibration, the simulation-to-reality (sim2real) gaps often persist, inevitably introducing artifacts in reconstructed outputs.

An alternative approach, hyperspectral super-resolution from RGB, presents another solution, but ensuring fidelity in spectral reconstruction of unknown scenes remains challenging, even though performance at the dataset level is acceptable. Other methods, such as utilizing metalenses [13], photonic crystals [14], and Fabry-Pérot based random filters [15], leverage micro- and nanofabrication techniques to optimize filtering and encoding [16]. However, from the perspectives of manufacturing costs and sample consistency, these approaches remain largely confined to laboratory settings and are not yet scalable for broader applications.

To address the challenges of existing SSI methods, we propose a cost-effective, compact, and user-friendly SSI solution, Aperture Diffraction Imaging Spectrometer (ADIS). In ADIS, the lens features a tightly fitting orthogonal mask, uniformly distributed in binary form along the orthogonal direction. This configuration forms an Orthogonal Diffraction Lens (ODL), which can be rigorously characterized physically. The ODL enables SSI without increasing the camera's physical footprint and eliminates the need for calibration. Furthermore, ADIS directly utilizes theoretically computed point spread functions (PSFs) for forward modeling and reconstruction guidance, while accommodating lens-dependent convolutional degradation arising from different optical configurations. By explicitly tolerating such practical optical variations, ADIS further strengthens its calibration-free property.

In the aperture plane, the orthogonal mask modulates the

Tao Lv, Quan Yuan, Shiqiao Li, Chenglong Huang, Linsen Chen, Chongde Zi, Shuming Wang, and Xun Cao are with Nanjing University, Nanjing, 210023, China. E-mail: {lvtao, lishiqiao, chenglong-huang} @smail.nju.edu.cn, {yq, chenls, zichongde, wangshuming, caoxun} @nju.edu.cn.

Tao Lv and Quan Yuan contributed equally.

Shuming Wang and Xun Cao are the corresponding authors.

Figure

Fig. 1. The imaging principle of ADIS. Light from the target scene is modulated by the Orthogonal Diffraction Lens (ODL) and captured by an array-filtered image sensor. The compressed measurements are reconstructed into HSIs using theoretically computed PSFs and filter functions (sensor parameters) as priors. The theoretically computed PSFs enable calibration-free reconstruction while tolerating lens-dependent variations across different optical configurations. The right side shows exemplar measurements and the corresponding reconstructed HSIs.

incident light amplitude and generates lattice-like diffraction PSFs (Fig. 1), which multiplex spectral information of different wavelengths onto distinct sensor locations and enable full-resolution spectral recovery from superpixel-level filtered measurements. Additionally, according to Babinet's principle, complementary masks produce similar diffraction patterns, which can be exploited to enhance the energy efficiency. However, the orthogonal diffraction encoding presents a challenging inverse reconstruction problem. To address this, we propose an Orthogonal Diffraction-Aware Unfolding Framework (ODAUF), which possesses decoupled perceptual capabilities for diffraction degradation. Within this framework, we have meticulously designed a diffraction-aware enhanced Voxel Shift Transformer (VST) that implements high-dimensional voxel orthogonal shifts through shuffle and fractional pixel shift operations. The VST serves as the executor for the ODAUF's regularization component.

Notably, we investigate the specific implementation of the VST core component, the Learning Shifts Module (LSM), to enhance generalizability and improve reconstruction quality in both high-resolution simulations and real-world experiments. By integrating the VST into the ODAUF, we establish a Transformer-based deep unfolding algorithm, the Orthogonal Diffraction-Aware Unfolding Voxel Shift Transformer (ODAUVST), for ADIS reconstruction. This integration enables ADIS to achieve optimal high-dimensional spectral acquisition performance within a compact SSI configuration.

To validate the imaging performance of ADIS, we systematically analyze the imaging optical theory and reconstruction algorithms, comparing various imaging systems and hardware design parameters, demonstrating real spectral imaging results with single-exposure captures. Overall, we have achieved full-resolution SSI without system calibration, effectively extending the spectral perception capabilities of digital cameras within the footprint of standard RGB cameras. Specifically, our contributions are as follows:

• Development of a cost-effective SSI system that integrates an orthogonal diffraction lens (ODL) with a bare sensor, enabling calibration-free and sim2real-aligned compact SSI.

• Introduction of a principled diffraction-projection-guided Framework, ODAUF, based on the unfolding architecture of an optimization procedure with a spatial-spectral prior, mitigating the ill-posedness of spectral reconstruction in ADIS.

• Design of the diffraction-aware enhanced VST, leveraging fractional shift operations to enhance degradation perception and generalizability. By plugging VST into ODAUF, we realize ODAUVST with excellent restoration and reduced parameters in high-resolution simulations and real experiments.

• A prototype device combined with ODAUVST is constructed for calibration-free SSI, while extensive experiments demonstrate the excellent superiority of our proposed methods.

References (46)