FISICA: A Deployed Service for Plantar-Pressure and Posture Assessment with Ontology-Grounded Recommendation

Juhwan Song, Heejung Kim, Juntae Noh, Jonghak Ryu, Huiju Park, Junseong Lee, Dohyeon Ahn, Byungwoo Jo

Abstract

FISICA is a body-assessment and recommendation service running in production. One standing session with two photographs returns foot-loading measures, posture coordinates, a driven 3D avatar, a visual report, and ranked shoe and exercise candidates. Measurement comes from a purpose-built scale carrying 634 force-sensitive elements on a 1 cm grid and four load cells, and a rule-based evaluator controls every recommendation while a language model only explains the stored result. The method contribution is the avatar. Instead of mapping a measured angle onto a rig through a tuned gain, we measure the avatar with the same function used on the subject and solve until the two agree, on a sampling-invariant spinal metric that separated a normal from a kyphotic record by 7.2° against 0.9° for a single-joint formulation. In production, general APIs respond at a 0.023 s median, plantar-pressure analysis at 0.45 s, and recommendation at 2.16 s to 2.26 s with the rule-based portion under one second in every trial. The served keypoint graph reaches 0.960 PCK@0.2 on public data, and the catalog holds 699 shoes with 10 500 typed facts. An approved study supplies the radiographic reference for the validation still ahead.

1 Introduction

Standing-posture and foot-loading tests usually need radiography or a laboratory [9, 30]. Both are costly and hard to reach outside a clinic. FISICA replaces that entry step with a pressure-sensing scale and two RGB photographs.

What the service delivers. One standing session produces six outputs: a plantar-pressure map with regional loads and foot dimensions, a foot-type label, posture coordinates with alignment indicators, a driven 3D avatar, a ranked list of shoes with the reason for each match, and a list of exercises under safety rules. Every output is stored with the measurement record and with the model, rule, and catalog versions that produced it.

What is new. The measurement components are established: a resistive pressure array, a keypoint detector, a rule evaluator. The contribution is what happens after measurement. A system that shows a body model next to a number usually drives the model from the number through a hand-tuned mapping, so the figure illustrates the finding and nothing checks that the two agree. We instead measure the avatar with the same function applied to the subject and solve until the two match. Doing so requires a spinal metric whose value does not change with how densely the spine is sampled, because the subject chain has five points and the avatar chain has nineteen. The metric we adopt for that reason also turns out to discriminate: on two records it separates a normal from a kyphotic posture by 7.2°, where the single-joint formulation it replaced separates them by 0.9°. Alongside this we report two things that are rarely published for a service of this kind: derived-angle error as a function of subject scale rather than averaged over it, and the service-level cost of every feature in production.