arXiv:2608.29348cs.AIAug 2026

Manuscript Offprint

arXiv:2608.29348

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To, Máté Sik, Cédric Hémon, Thomas Weikert, Martin Segeroth

Abstract

Background: Patient details (weight, height, age, sex) and acquisition metadata (e.g. reconstruction kernel, noise, contrast phase, field of view) are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives.

Purpose: To develop and evaluate a fast and robust open-source model that predicts patient and acquisition characteristics directly from CT and MR images.

Materials and Methods: In this retrospective study, separate 3D ResNet-10 ensembles for CT and MR were trained with 57,291 and 43,200 clinical examinations acquired from January 2011 to August 2025. Both models jointly predicted weight, height, age, sex, contrast presence, cranial and caudal vertebral coverage, and image noise; the CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time, whereas the MR model predicted sequence class. Performance was evaluated on internal CT (n = 501) and MR (n = 636) test sets and an external CT dataset (n = 54). Regression performance was summarized with mean absolute error (MAE), classification with F1 score, and paired models with Wilcoxon signed-rank or exact McNemar tests with Holm correction.

Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1 of 0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and 0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P≤.042P \leq .042). Additional-target performance included F1 scores of 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. On external full-coverage CT, MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1 of 0.971. CPU inference required 20 seconds for CT and 12 seconds for MR, supporting CPU-only deployment.

Conclusion: One 3D multitask model per modality can rapidly recover a broad set of patient and acquisition characteristics from heterogeneous CT and MR examinations, supporting metadata quality control and automated image-processing pipelines. The models are available in TotalSegmentator (https://github.com/wasserth/TotalSegmentator).

1 Introduction

Patient weight, height, age, and sex affect contrast administration, drug dosing, radiation-dose optimization, and risk stratification [Bae, 2010, Griggs et al., 2012, Regitz-Zagrosek, 2012]. Weight and height also define body mass index (BMI) and body surface area (BSA) [Flegal et al., 2013, Mosteller, 1987]. Yet these values may be missing, outdated, or estimated in routine metadata [Menon & Kelly, 2005, Lin et al., 2009].

*Corresponding author: jakob.wasserthal@usb.ch

Acquisition characteristics are similarly important. Tube voltage, tube current, reconstruction kernel, and noise affect CT dose, image appearance, and quantitative reproducibility [Kaza et al., 2014, Christianson et al., 2015, Choe et al., 2019]. Contrast presence and post-injection timing determine enhancement phase, while MR sequence labels determine which downstream algorithms and quantitative measurements are appropriate [Muhamedrahimov et al., 2022, Cluceru et al., 2023]. Cranial and caudal vertebral levels provide an image-based description of anatomical coverage that can route examinations to compatible pipelines and identify excessive or incomplete coverage [Zhang et al., 2015, Lessmann et al., 2019]. Automated recovery of these properties is therefore relevant to archive quality control, cohort curation, protocol harmonization, and large-scale image analysis.

Prior work estimated individual body characteristics from CT scouts, localizers, dose metrics, tissue segmentations, or thoracoabdominal images [Ichikawa et al., 2021, Demircioğlu et al., 2023, Ichikawa et al., 2024, Schenkl et al., 2025, Kerber et al., 2023]. Other image-based systems classified CT contrast or MR acquisition type [Li et al., 2024, Cluceru et al., 2023], and multitask prediction of MR acquisition parameters has been demonstrated in breast imaging [Konz & Mazurowski, 2024]. However, a single open-source tool that jointly predicts patient characteristics and a broad modality-specific set of acquisition properties from both CT and MR volumes has not been established.

The purpose of this study was to develop and evaluate one fast 3D multitask CNN per modality for predicting patient and acquisition characteristics from heterogeneous CT and MR images (Fig. 1). We compared core outputs with a segmentation-derived XGBoost baseline, evaluated external CT generalization, and tested whether joint prediction reduced accuracy relative to target-specific models.

References (28)