arXiv:2608.29656cs.DCAug 2026

Manuscript Offprint

arXiv:2608.29656

A Smallest-Need-First Job Scheduling Framework with Adaptive Optimization of Idle Node Counts for Energy-Efficient HPC Systems

Reza Pulungan, Raka Satya Prasasta, Santana Yuda Pradata, Mursalim, Hiroyuki Takizawa, Muhammad Alfian Amrizal

Reza Pulungan, Raka Satya Prasasta, Santana Yuda Pradata, Mursalim, Hiroyuki Takizawa, Muhammad Alfian Amrizal

Abstract—Power-state management in high-performance computing (HPC) clusters must reduce idle energy without excessive wake-up delays for rigid parallel jobs. This paper presents SNF-ICON, an event-driven controller combining smallest-need-first (SNF) gang scheduling, predictive wake timing, and adaptive warm-spare control. At each scheduler invocation, recent interarrival and completed-service samples are screened for sufficiency, exponential-like variability, low lag-one autocorrelation, and acceptable Kolmogorov–Smirnov distance. Rejected or data-sparse windows use SNF+IPM (Intelligent Power Manager), whereas accepted windows activate release prediction and an exponential next-event model. Warm-spare optimization is applied only when queue, event, and arrival-recency conditions permit, balancing estimated waiting and non-compute energy over a timeout-capped horizon. We evaluate four DAS2 trace segments and a generated Markovian workload on AOBA-derived 64-node models, plus SDSC Blue on an AOBA-derived 1152-node model. SNF-ICON is compared with SNF+IPM and First Come First Served (FCFS) + backfilling with IPM. It reduces average waiting time relative to the FCFS-based baseline in all six cases and remains close to at least one heuristic energy baseline in five. The generated workload spends substantial time in ICON mode, whereas DAS2 workloads operate mainly in fallback. Furthermore, cross-platform results show strong dependence on node-transition and power models. Thus, no single policy or parameter set works best in every case.

Index Terms—High-performance computing, energy-aware scheduling, gang scheduling, power-state management, smallest-need-first scheduling, stochastic spare capacity, workload screening, runtime prediction, fallback control.

I. INTRODUCTION

HIGH-performance computing (HPC) systems use large amounts of energy, and a single installation may require 20 MW or more. At the German HPC centers surveyed by Suarez et al. [1], electricity and cooling made up between 12% and 50% of the systems' total cost of ownership. One source of avoidable energy use is idle compute capacity: nodes may stay powered on for long periods without running jobs. Energy-aware HPC schedulers therefore often use dynamic power management, such as lowering operating frequencies or switching off idle nodes [2].

Production systems have also shown that idle-node power management can save substantial energy. At the Jülich Supercomputing Centre, the Slurm workload manager [3] was configured to power down idle nodes. After this change, the annual electricity use of the JUSUF system fell from about 660 MWh in 2022 to 495 MWh in 2023, a reduction of 25% [1]. This result shows the practical value of controlling node power states. It also raises an important question: how many nodes can be switched off without making jobs wait too long?

Switching off too many nodes can increase job waiting time because a sleeping node must wake before it can run a job. Keeping too many nodes active reduces this delay but wastes energy while they are idle. This trade-off is especially important for rigid parallel, or gang-scheduled, jobs. A job that requests r nodes can start only when all r nodes are available at the same time. Job order and node power states should therefore be managed together [4]–[6].

Existing methods include idle-timeout rules [7], [8], reinforcement-learning controllers [9], [10], and scheduler-power-manager heuristics [11], [12]. Learning-based controllers can learn complex switch-on and switch-off actions, but they have several practical difficulties. Their reward must balance waiting time and energy, training needs a large amount of data and interaction, and the learned policy may work poorly when the workload or data quality changes [13]–[15]. PSAS+IPM [16] avoids offline training by using clear scheduling and power-management rules, but it still uses First Come First Served (FCFS) with Extensible Argonne Scheduling sYstem (EASY) backfilling [17], [18]. EASY backfilling is an aggressive backfilling policy in which later jobs may fill gaps in the schedule, provided that they do not delay the reserved start time of the head-of-queue job.

The scheduling method matters because power management cannot remove delays caused by job order. In a large multiserver-job model, Hong and Wang [19], [20] showed that FCFS mean waiting time grows worse than a lower bound that applies to all policies, while Smallest-Need-First (SNF) reaches that lower bound in growth rate. Their theorem does not directly cover EASY backfilling, finite non-preemptive HPC traces, or node wake-up times. Even so, it gives a clear reason to compare an SNF-based scheduler with an FCFS-based scheduler. In this paper, a job's need is its requested

R. Pulungan, S. Y. Pradata, Mursalim, and M. A. Amrizal are with the Department of Computer Science and Electronics, Universitas Gadjah Mada, Yogyakarta, Indonesia.

R. S. Prasasta is with the Faculty of Industrial Technology, Universitas Ahmad Dahlan, Yogyakarta, Indonesia.

H. Takizawa is with the Cyberscience Center, Tohoku University, Miyagi, Japan.

This work has been submitted to the IEEE Transactions on Parallel and Distributed Systems for possible publication.

node count, and jobs are not preempted.

Changing the queue order does not solve the power-state problem by itself. A method such as PSAS+IPM can plan node transitions for queued jobs, but it uses requested runtimes, which may differ greatly from actual runtimes [17], [21]. Planning for queued jobs also does not decide how much capacity should remain ready for future jobs. With perfect future information, a controller could wake exactly the required nodes so that they become ready when the next job arrives. In practice, future arrival times and node requests are unknown. The controller must therefore choose how many warm spare nodes to keep: too few cause wake-up delay, while too many waste idle energy.

This paper proposes SNF-ICON, an event-driven method that combines SNF scheduling, predicted wake times for queued jobs, and adaptive control of warm spare nodes for future jobs. Its main decision is the number of spare nodes to keep ready. The one-step calculation assumes exponential times between arrivals and completions, but real workloads do not follow this model at all times. We therefore check recent interarrival and completed-service data before using the calculation. When the recent data pass the check, the ICON controller predicts job releases and selects a warm-spare target. When the data fail the check, or there are too few samples, the system uses the SNF+IPM fallback. This limits model-based planning to periods when the recent workload fits the model closely enough. Furthermore:

• We compare SNF with FCFS+backfilling-based power-management methods for rigid parallel jobs, motivated by a theoretical result on mean waiting time for multiserver jobs.

• We develop a one-step method for choosing how many warm spare nodes to keep ready.

• We define a fallback rule that uses SNF+IPM when recent data fail the workload check or contain too few samples. ICON-specific release prediction and spare-node selection are used only when the recent data pass the check.

• We predict job runtimes using an adaptive log ratio of actual to requested runtime. For running jobs, we estimate the remaining time with a conditional log-normal model. We combine these predictions with EMA estimates of arrival rate, service rate, and requested-node counts.

• We evaluate the method against FCFS/B+IPM and SNF+IPM, including analyses of the workload check, fallback, arrival-recency gate, platform, workload, parameters, and large-job waiting time.

The rest of the paper reviews related power-management methods, explains the choice of SNF and warm spare nodes, defines the system model and SNF-ICON method, and presents the implementation and evaluation.