Abstract—Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.
Index Terms—Remote photoplethysmography, vision-language models, facial videos
I. INTRODUCTION
Remote photoplethysmography (rPPG) enables contactless physiological measurement by capturing subtle variations in facial skin color induced by cardiac blood-volume changes. Requiring only a camera and no physical contact, rPPG has been widely investigated for remote physiological monitoring and clinical care [1]–[4], affective-state analysis [5], and mobile physiological sensing [6]. However, reliable

Fig. 1: Comparison between direct rPPG estimation and the proposed interference-aware temporal feature refinement. (a) Direct prediction maps learned temporal features directly to rPPG signal. (b) PhysVR integrates physiological reliability and VLM-derived visual interference evidence to refine temporal features before final estimation. (c) An example showing that learned temporal features may remain affected by interference under challenging visual conditions, while further refinement improves the final rPPG prediction.
rPPG estimation remains challenging in practical environments, where weak pulse-related variations can be easily obscured by illumination variation, head motion, facial blur, and region-of-interest (ROI) instability.
Existing deep-learning based rPPG methods mainly follow two feature modeling strategies. STMap-based approaches organize temporal color traces extracted from multiple facial regions into structured spatio-temporal maps, whereas video-based approaches learn spatial and temporal features directly from facial clips [7], [8]. Their architectures have evolved from convolutional networks to transformer-based and state-space models [9], [10]. Despite differences in feature extraction and temporal modeling, most existing methods directly regress rPPG signals from the learned features.
Under this direct estimation paradigm, the feature extractor must preserve weak pulse-related variations while suppressing non-physiological changes. Illumination variation alters facial color and intensity distributions, head motion and ROI instability disrupt temporal correspondence across frames, and facial blur attenuates subtle skin-color variations [11]–[14]. Existing methods generally address these factors during feature learning and subsequently use the learned temporal features for signal estimation. However, whether these features
Zixu Li, Jianjun Qian, Daoheng Li, Lei Luo, and Jian Yang are with the PCA Lab, Key Lab of Intelligent Perception and Systems for High-Dimensional Information of Ministry of Education, School of Computer Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. Hang Shao is with the College of Computer Science and Technology, Qingdao University, Qingdao 266071, China. (email:lizixu@njust.edu.cn; csjqian@njust.edu.cn; shaohang@qdu.edu.cn; li-daoheng@njust.edu.cn; cslluo@njust.edu.cn; csjyang@njust.edu.cn).
Copyright © 20xx IEEE. Personal use of this material is permitted. However, permission to use this material for any other purposes must be obtained from the IEEE by sending an email to pubs-permissions@ieee.org.
remain affected by interference after feature learning and how to further suppress such interference before prediction are rarely examined.
Recently, pretrained vision-language models (VLMs) and large language models (LLMs) have been introduced into remote physiological measurement. Existing studies exploit cross-modal knowledge to improve physiological feature learning and signal estimation [15], [16]. rPPG-VQA further combines signal-quality analysis with multimodal scene assessment to select suitable videos for unsupervised rPPG training [17]. These studies demonstrate the potential of language-guided visual understanding for remote physiological measurement. Nevertheless, the potential of VLMs to characterize visual interference for subsequent temporal feature refinement remains largely unexplored.
To address this problem, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for robust rPPG estimation. Since interference may remain in the learned temporal features after feature learning, PhysVR further refines these features before final rPPG estimation. As illustrated in Fig. 1, most existing methods directly estimate rPPG from the learned temporal features after feature learning. However, under challenging visual conditions, these features may still be affected by interference, leading to deviations in the estimated rPPG signal. PhysVR therefore introduces further temporal feature refinement before final estimation, guided by physiological reliability evidence and visual interference evidence. Specifically, the physiological backbone extracts global temporal features and predicts a coarse rPPG signal. Based on the local temporal characteristics of the coarse prediction, time-resolved physiological reliability evidence is derived to reflect its reliability at different temporal positions. In parallel, a frozen VLM processes sampled facial frames under an interference-oriented prompt, and an evidence head derives clip-level visual interference evidence to characterize the visual interference present in the input video. Temporal cross-attention integrates the physiological reliability evidence and visual interference evidence with the global temporal features to construct an interference-aware temporal context. Guided by this context, a shared temporal correction unit first performs general refinement of the learned temporal features, while four interference-specific experts further suppress different types of interference through adaptive routing. The refined temporal features are then used for final rPPG estimation.
Our contributions are summarized as follows:
• We propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework that further refines learned temporal features after feature learning, reducing the influence of interference that may remain under challenging visual conditions.
• We construct an interference-aware temporal context by integrating physiological reliability evidence and VLM-derived visual interference evidence with global temporal features through temporal cross-attention, allowing complementary physiological and visual information to jointly guide the subsequent refinement process.
• We design a context-guided refinement module consisting of a shared temporal correction unit, four interference-specific experts, and an adaptive temporal router. The shared unit performs general temporal refinement, while the router selectively activates interference-specific experts to further suppress interference. Experiments on five public benchmarks demonstrate the effectiveness of PhysVR under both intra-dataset and cross-dataset.
A. Remote Physiological Measurement
Early rPPG methods relied on handcrafted color-space projections and signal-processing priors to recover pulse signals while suppressing illumination changes and motion artifacts [18], [19]. With the development of deep learning, the field gradually shifted toward data-driven spatio-temporal feature learning. Representative architectures include convolutional attention networks [8], 3D spatio-temporal networks [20], temporal-shift models [21], transformer-based models [9], and efficient end-to-end networks [22]. More recent studies have further explored periodic sparse attention, state-space modeling, diffusion-based modeling, and physics-grounded temporal modeling [10], [23]–[25].
Beyond architectural advances, considerable efforts have focused on improving robustness to environmental interference and domain variation. ND-DeeprPPG disentangles environmental noise from pulse-related features by using background regions as a reference [26]. Shao et al. [27] further model complex time-varying interference under real-world and extreme illumination conditions through interference sharing and disentanglement. FLOW improves cross-domain generalization by aligning multi-source features through optimal-transport-driven feature warping [28]. Despite these advances, existing methods mainly suppress or disentangle interference during feature learning, or reduce distribution discrepancies across domains. The learned temporal features are then typically used directly for rPPG estimation, without further interference-aware and refinement before signal prediction.
B. Vision-Language Models
Vision-language models (VLMs) jointly model visual and textual information to support open-vocabulary recognition, visual grounding, image captioning, and multimodal reasoning [29]–[32]. Their prompt-conditioned features have also been increasingly adapted to domain-specific visual understanding tasks.
Pretrained multimodal models have recently been introduced into remote physiological measurement for different purposes. Yue et al. [15] align visual and textual features carrying physiological frequency information to facilitate self-supervised rPPG learning. PhysLLM incorporates a large language model (LLM) into rPPG estimation through cross-modal alignment and task-oriented physiological cues [16]. rPPG-VQA employs a multimodal large language model (MLLM) to jointly assess signal quality and recording conditions, enabling the selection of suitable videos for unsupervised

Fig. 2: Overview of PhysVR. The physiological backbone extracts global temporal features and derives time-resolved physiological reliability evidence from a coarse rPPG signal. In parallel, a frozen VLM processes sampled frames under an interference-oriented prompt, whose outputs are used to derive clip-level visual interference evidence. Temporal cross-attention integrates both evidence sources with the global temporal features to construct an interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress interference through adaptive routing before final rPPG estimation.
rPPG training [17]. Collectively, these studies exploit pre-trained multimodal models for physiological feature learning, signal estimation, or training-data selection. However, they primarily use multimodal information to support physiological representation learning or data assessment, rather than to provide visual interference information for further refinement of learned temporal features.
III. METHODOLOGY
As illustrated in Fig. 2, PhysVR consists of three main components: a physiological backbone, a VLM-based visual interference perception branch, and a context-guided refinement module. The physiological backbone provides the global temporal representation for rPPG estimation and derives time-resolved physiological reliability evidence from a coarse prediction, reflecting local variations in prediction reliability. In parallel, the VLM-based branch characterizes visual interference present in the input video and produces clip-level visual interference evidence. These two sources of evidence provide complementary physiological and visual information for subsequent temporal feature refinement. The context-guided refinement module then combines shared temporal refinement with interference-specific experts and adaptive temporal routing to further refine the learned temporal features before final rPPG estimation.
A. Physiological Backbone
The physiological backbone extracts global temporal features H from frame differences and predicts a coarse rPPG signal . The coarse signal is used to derive time-resolved physiological reliability evidence R.
Given a facial video , we construct a frame-difference sequence:
(1)
The zero tensor 0 has the same dimensions as a video frame and is inserted at the first position to preserve the sequence length. Frame differencing suppresses temporally invariant facial appearance while emphasizing adjacent-frame variations, including subtle pulse-related changes and non-physiological fluctuations caused by visual interference.
Spatial features are first extracted from the difference sequence and then processed along the temporal dimension:
The spatial encoder consists of stacked Spatial-Blocks. As illustrated in Fig. 3(a), each Spatial-Block uses a residual bottleneck composed of pointwise and spatial convolutions. Spatial average pooling reduces the spatial resolution, while the projection layer adjusts the feature dimension for subsequent temporal modeling. As shown in Fig. 3(b), the contains two Depth-Blocks followed by two Spatial-Blocks to model temporal dependencies. The output denotes the global temporal features.
A signal prediction head maps the global temporal features H to a coarse rPPG signal:
where denotes the coarse rPPG signal.
(a) Spatial-Block

(b) T-Net
Fig. 3: Principal components of the physiological backbone. (a) A Spatial-Block uses a residual bottleneck composed of pointwise and spatial convolutions. (b) The T-Net contains two Depth-Blocks followed by two Spatial-Blocks.
We construct four time-aligned descriptors to capture local temporal characteristics of the coarse rPPG signal:
The operator denotes the first-order temporal difference, with a zero inserted at the first position to preserve the sequence length, and measures changes between adjacent signal values. The fixed band-pass operator retains frequencies within 0.7–3.0 Hz, while the fixed low-pass operator retains frequencies below 0.5 Hz. Both operators are implemented as fixed, differentiable frequency-domain masks. The operator denotes a nine-frame moving average with boundary padding. Accordingly, describes the local magnitude of the physiological-band component, while captures slowly varying components. For , maps to position-wise modulation coefficients through a sigmoid, which adaptively weight the deviation of the coarse signal from its local temporal mean.
The coarse rPPG signal and the four descriptors are concatenated along the feature dimension:
A one-dimensional temporal convolution maps the concatenated descriptors to the feature dimension of H:
The resulting sequence summarizes local temporal characteristics related to the reliability of the coarse prediction and serves as time-resolved physiological reliability evidence.
B. VLM-Based Visual Interference Perception
While R captures time-resolved signal characteristics related to coarse-prediction reliability, it does not explicitly characterize visual interference in the input clip. As shown in Fig. 2(a), the VLM-based branch therefore extracts clip-level visual interference information from sampled facial frames. A fixed interference-oriented prompt guides the VLM to focus on visual factors relevant to rPPG estimation, including illumination fluctuation, head motion, facial blur, and ROI instability. The same prompt is used for all clips and datasets.
To cover the visual conditions throughout the clip while limiting the computational cost of VLM processing, we uniformly sample N frames:
(7)
where . The first and last frames are always selected, and the remaining sampling positions are distributed across the clip while preserving the original temporal order.
The sampled frames and the fixed prompt p are jointly processed by the frozen VLM:
We instantiate with Qwen2-VL-2B-Instruct [33] and keep its parameters frozen throughout training. The output contains the final-layer hidden states of the multimodal input sequence, where denotes the valid sequence length and denotes the index of the final non-padding token. The corresponding hidden state is directly used as the VLM feature for subsequent visual evidence extraction.
A trainable evidence head maps to the visual interference evidence:
Here, and are learnable weight matrices, while and are the corresponding bias vectors. denotes layer normalization, and denotes the GELU activation. The vector serves as clip-level visual interference evidence that reflects the visual interference present in the input clip.
C. Context-Guided Temporal Feature Refinement
As shown in Fig. 2(c), PhysVR integrates the physiological reliability evidence R and visual interference evidence with the global temporal features H through temporal cross-attention. Since R is time-resolved while is clip-level, H is used as the query, and the two evidence sources are projected into the key and value spaces to construct an interference-aware temporal context for feature refinement. For , the context construction is formulated as:
Here, , , , and are learnable projection matrices. The key and value sequences
consist of physiological evidence vectors and one clip-level visual evidence vector. Cross-attention uses the projected global temporal features as queries to obtain the interference-aware temporal context .
The temporal context is concatenated with the global temporal features and projected to dimension . A shared temporal correction unit then performs general refinement:
The shared temporal correction unit first projects the concatenated features from 2d to d, followed by three residual Shared Correction Blocks (SCBs) and a pointwise projection. Each SCB contains layer normalization, a depthwise temporal convolution, and two pointwise projections with GELU activation. The temporal convolutions use a kernel size of 5 and dilation rates of 1, 2, and 4, respectively, enabling multi-scale temporal correction. The resulting correction is scaled and added to to obtain .
The shared unit captures temporal deviations common to different interference conditions. To further suppress specific types of interference, we introduce four experts for illumination variation, head motion, facial blur, and ROI instability:
A temporal router independently controls the activation of the four experts at each temporal position:
Here, contains the position-wise activation probabilities, and each denotes the binary temporal gate of expert . The four expert gates are independently predicted, allowing multiple experts to be activated simultaneously when different interference factors coexist. The binary gates use a threshold of 0.5, with a straight-through estimator adopted during training.
Each expert is conditioned on the visual interference evidence through expert-specific channel-wise modulation:
(14)
Here, are expert-specific modulation parameters applied across the temporal dimension. The four experts use different transformations for different types of interference. The illumination expert performs channel-wise correction using pointwise projections. The motion expert combines first-order temporal differences with local temporal convolution to capture abrupt temporal variations. The blur expert models local temporal deviations from neighboring features to compensate for locally weakened temporal variations. The ROI-instability expert employs dilated temporal convolutions with different dilation rates to capture longer-range temporal inconsistency. Each expert produces an interference-specific correction .
The activated expert corrections are combined with U:
The decoder maps the refined temporal features to the final rPPG signal .
D. Training Objective
PhysVR produces a coarse rPPG signal and a final prediction . Since the physiological reliability evidence R is derived from the coarse prediction, is explicitly supervised to preserve meaningful temporal information.
For a prediction y and ground-truth signal s, the signal loss is defined as:
where denotes the point-wise MSE loss, is the Pearson correlation loss, and is the Smooth L1 distance between the normalized power spectra within the physiological frequency range.
The overall objective is:
Where controls the coarse-signal supervision. All trainable components are optimized jointly.
IV. EXPERIMENT
We evaluate PhysVR on five public rPPG benchmark datasets: BUAA-MIHR [34], VIPL-HR [35], [36], NIRP-DRV [37], NIRP-IND [38], and MMPD [39]. Both intra-dataset and cross-dataset evaluations are conducted to assess HR estimation accuracy. We first describe the datasets, evaluation metrics, and implementation details, and then compare PhysVR with state-of-the-art methods through quantitative and qualitative analyses. We further analyze the trade-off between estimation accuracy and computational complexity, followed by ablation studies of the principal components of PhysVR.
A. Datasets
BUAA-MIHR: BUAA-MIHR [34] is designed for rPPG evaluation under low-illumination conditions. It contains 165 RGB facial videos from 15 subjects recorded at 11 illumination levels ranging from 1.0 to 100.0 lux. Each 60-s video was captured at 30 fps with synchronized finger-clip PPG recorded at 60 Hz. We use recordings with illumination intensities of at least 6.3 lux.
VIPL-HR: VIPL-HR [35], [36] contains 3,130 facial videos from 107 subjects under less-constrained conditions, including variations in illumination, head motion, and acquisition devices. Each video lasts approximately 30 seconds, with synchronized finger BVP signals provided as reference.
NIRP-DRV: NIRP-DRV [37] contains 190 RGB and near-infrared facial recordings from 19 subjects collected in realistic driving environments. The recordings include diverse in-vehicle illumination conditions and natural head movements, with synchronized pulse-oximeter measurements as reference.
NIRP-IND: NIRP-IND [38] provides a complementary indoor setting with 15 RGB and near-infrared recordings from 8 subjects. The recordings include both stationary and motion conditions, with synchronized pulse-oximeter measurements as reference.
MMPD: MMPD [39] is a mobile rPPG dataset containing 660 one-minute RGB facial videos from 33 subjects. The recordings cover Fitzpatrick skin types III–VI, four illumination conditions, and four activities: stationary, head rotation, talking, and walking. Synchronized finger PPG signals are provided as reference.
B. Performance Metrics
Following the standard evaluation protocol [40], we use three commonly adopted metrics for heart rate estimation: Mean Absolute Error (MAE), Root Mean Square Error (RMSE), and Pearson's Correlation Coefficient ( ). Given N test samples, let and denote the estimated and ground-truth heart rates of the i-th sample, respectively. MAE and RMSE are defined as:
Pearson's correlation coefficient is defined as:
Where and denote the mean estimated and ground-truth heart rates, respectively. Lower MAE and RMSE indicate smaller estimation errors, while a higher indicates stronger agreement between the estimated and ground-truth heart rates.
C. Implementation Details
We implement PhysVR using the rPPG-Toolbox [45] and conduct all experiments on RGB facial videos. Facial regions are cropped, resized to , and divided into 160-frame clips after temporal alignment and reference-signal resampling. For each clip, eight uniformly sampled frames are processed with a fixed interference-oriented prompt by the frozen Qwen2-VL-2B-Instruct [33]. All remaining components are jointly optimized for 30 epochs using AdamW with a learning rate of . The shared correction scale is initialized to 0.10, while the four expert-specific scales , , , and are initialized to 0.05. We set , , , and .
All dataset partitions are subject-disjoint. VIPL-HR follows the official five-fold protocol, with four folds used for training

Fig. 4: Comparison of rPPG estimation results on VIPL-HR. The top row presents the predicted and ground-truth rPPG signals, while the bottom row shows their corresponding normalized power spectral density distributions. From left to right, the columns correspond to PhysVR, PhysLLM, PHASE-Net, and RhythmFormer.
and one for testing. BUAA-MIHR, MMPD, and the combined NIRP dataset use a 3:1 training-to-testing split. NIRP-IND and NIRP-DRV are partitioned jointly but evaluated separately, while BUAA-MIHR and MMPD are used only for intra-dataset evaluation. Following prior work [27], cross-dataset evaluation is performed without target-domain training or fine-tuning. We report results for NIRP → VIPL-HR, VIPL-HR → NIRP-IND, and VIPL-HR → NIRP-DRV.
D. Intra-dataset Evaluation
Table I summarizes the intra-dataset results on five benchmarks. PhysVR achieves the best overall performance across all evaluated datasets, consistently yielding lower MAE and RMSE together with higher correlation. On NIRP-IND, PhysVR obtains an MAE of 0.38 bpm, an RMSE of 0.85 bpm, and a correlation coefficient of 0.92. Compared with PHASE-Net, the strongest competing method on this subset, the MAE and RMSE are reduced by 20.8% and 13.3%, respectively. On the more challenging NIRP-DRV subset, PhysVR achieves an MAE of 2.56 bpm and an RMSE of 5.85 bpm, compared with 2.95 bpm and 6.13 bpm for PhysLLM, while improving the correlation coefficient from 0.86 to 0.87. These results demonstrate robust estimation performance under both indoor and driving conditions. PhysVR also achieves the best results on VIPL-HR, BUAA-MIHR, and MMPD. On VIPL-HR, it obtains an MAE of 3.59 bpm, an RMSE of 5.68 bpm, and a correlation coefficient of 0.88, reducing the MAE and RMSE of PHASE-Net by 7.2% and 10.8%, respectively. On BUAA-MIHR, the best competing MAE and RMSE are reduced from 0.58 bpm and 1.43 bpm to 0.42 bpm and 1.09 bpm, corresponding to improvements of 27.6% and 23.8%, respectively, while the correlation coefficient reaches 0.96. On MMPD, PhysVR obtains an MAE of 3.92 bpm, an RMSE of 8.03 bpm, and a correlation coefficient of 0.80. Compared with the best competing results, the MAE and RMSE are reduced by 10.1% and 2.3%, respectively. Overall, the consistent improvements across these benchmarks demonstrate the robustness of PhysVR under diverse conditions.
Beyond the aggregate metrics, Fig. 4 compares the predicted rPPG signals and power spectra on VIPL-HR. For the representative sample, PhysVR estimates an HR of 79.4 bpm, close to the ground-truth value of 78.8 bpm, with an absolute error of 0.6 bpm. Its predicted signal follows the reference periodicity, while the dominant spectral peak is well aligned with the
TABLE I: Intra-dataset comparison of remote HR estimation on NIRP-IND, NIRP-DRV, VIPL-HR, BUAA-MIHR, and MMPD. MAE and RMSE are reported in bpm. ↓ indicates that lower values are better, while ↑ indicates that higher values are better. The best results are highlighted in bold with a light-lavender background, while the second-best results are marked with a light-apricot background.
| Method / Venue | NIRP-IND | NIRP-DRV | VIPL-HR | BUAA-MIHR | MMPD | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MAE↓ | RMSE↓ | ρ ↑ | MAE↓ | RMSE↓ | ρ ↑ | MAE↓ | RMSE↓ | ρ ↑ | MAE↓ | RMSE↓ | ρ ↑ | MAE↓ | RMSE↓ | ρ ↑ | |
| POS [19] / TBME'2016 | 5.52 | 6.85 | 0.40 | 12.75 | 15.36 | 0.34 | 11.50 | 17.20 | 0.30 | 5.04 | 7.12 | 0.63 | 12.36 | 17.71 | 0.18 |
| CHROM [18] / TBME'2013 | 6.84 | 8.41 | 0.32 | 14.52 | 17.41 | 0.18 | 11.07 | 17.99 | 0.27 | 6.09 | 8.29 | 0.51 | 13.66 | 18.76 | 0.08 |
| LGI [41] / CVPR'2018 | 8.95 | 11.01 | 0.39 | 12.90 | 15.51 | 0.31 | 12.84 | 19.02 | 0.29 | 6.97 | 11.33 | 0.42 | 17.08 | 23.32 | 0.04 |
| DeepPhys [8] / ECCV'2018 | 3.11 | 4.44 | 0.74 | 13.22 | 18.39 | 0.43 | 11.00 | 13.80 | 0.11 | 4.78 | 6.74 | 0.69 | 22.27 | 28.92 | -0.03 |
| TS-CAN [21] / NeurIPS'2020 | 2.49 | 3.89 | 0.75 | 12.70 | 18.03 | 0.47 | 9.39 | 14.59 | 0.21 | 4.84 | 6.89 | 0.68 | 9.71 | 17.22 | 0.44 |
| PFE-TFA [42] / AAAI'2023 | 2.81 | 4.57 | 0.84 | 5.34 | 8.92 | 0.73 | 6.91 | 8.65 | 0.65 | 1.29 | 2.65 | 0.91 | - | - | - |
| NEST [43] / CVPR'2023 | 1.08 | 2.26 | 0.89 | 3.61 | 7.32 | 0.82 | 5.52 | 7.96 | 0.80 | 2.88 | 4.69 | 0.89 | - | - | - |
| ND-DeeprPPG [26] / TIP'2024 | 0.66 | 1.45 | 0.89 | 3.47 | 6.54 | 0.85 | 5.15 | 7.52 | 0.78 | 0.58 | 1.81 | 0.95 | - | - | - |
| EfficientPhys [22] / WACV'2023 | 1.37 | 4.81 | 0.81 | 3.67 | 12.28 | 0.81 | 5.23 | 8.25 | 0.72 | 1.43 | 4.98 | 0.93 | 13.47 | 21.32 | 0.21 |
| PhysFormer++ [44] / IJCV'2023 | 0.64 | 1.39 | 0.89 | 3.56 | 7.59 | 0.83 | 4.88 | 7.62 | 0.80 | 0.93 | 1.66 | 0.91 | - | - | - |
| RhythmFormer [23] / PR'2025 | 0.52 | 1.10 | 0.91 | 3.44 | 6.72 | 0.82 | 4.75 | 7.49 | 0.82 | 0.67 | 1.57 | 0.94 | 4.69 | 11.31 | 0.60 |
| PhysDiff [24] / AAAI'2025 | 0.50 | 1.06 | 0.91 | 3.24 | 6.26 | 0.83 | 3.92 | 6.65 | 0.85 | 0.82 | 1.71 | 0.93 | 7.17 | 9.63 | 0.78 |
| PHASE-Net [25] / CVPR'2026 | 0.48 | 0.98 | 0.91 | 3.18 | 6.23 | 0.86 | 3.87 | 6.37 | 0.86 | 0.63 | 1.43 | 0.94 | 4.78 | 8.22 | 0.71 |
| PhysLLM [16] / ICLR'2026 | 0.57 | 1.27 | 0.90 | 2.95 | 6.13 | 0.86 | 4.24 | 6.81 | 0.85 | 0.78 | 1.62 | 0.94 | 4.36 | 10.76 | 0.65 |
| PhysVR (Ours) | 0.38 | 0.85 | 0.92 | 2.56 | 5.85 | 0.87 | 3.59 | 5.68 | 0.88 | 0.42 | 1.09 | 0.96 | 3.92 | 8.03 | 0.80 |
TABLE II: Cross-dataset comparison of remote HR estimation. The models are trained on a source dataset and evaluated on a different target dataset. MAE and RMSE are reported in bpm. ↓ indicates that lower values are better, while ↑ indicates that higher values are better. The best results are highlighted in bold with a light-lavender background, while the second-best results are marked with a light-apricot background.
| Method / Venue | NIRP → VIPL-HR | VIPL-HR → NIRP-IND | VIPL-HR → NIRP-DRV | ||||||
|---|---|---|---|---|---|---|---|---|---|
| MAE↓ | RMSE↓ | ρ ↑ | MAE↓ | RMSE↓ | ρ ↑ | MAE↓ | RMSE↓ | ρ ↑ | |
| DeepPhys [8] / ECCV'2018 | 15.53 | 17.48 | 0.41 | 6.58 | 9.16 | 0.52 | 10.51 | 12.71 | 0.56 |
| TS-CAN [21] / NeurIPS'2020 | 12.04 | 15.12 | 0.45 | 6.57 | 9.25 | 0.57 | 10.37 | 12.65 | 0.61 |
| PFE-TFA [42] / AAAI'2023 | 8.20 | 11.22 | 0.64 | 1.87 | 3.67 | 0.77 | 7.82 | 9.99 | 0.64 |
| NEST [43] / CVPR'2023 | 5.15 | 8.78 | 0.72 | 2.78 | 4.63 | 0.78 | 6.27 | 8.45 | 0.65 |
| ND-DeeprPPG [26] / TIP'2024 | 5.08 | 7.92 | 0.75 | 1.74 | 3.28 | 0.81 | 6.18 | 7.75 | 0.68 |
| EfficientPhys [22] / WACV'2023 | 5.25 | 11.81 | 0.71 | 1.80 | 6.19 | 0.76 | 6.07 | 11.53 | 0.64 |
| PhysFormer++ [44] / IJCV'2023 | 5.09 | 8.97 | 0.71 | 1.79 | 3.77 | 0.81 | 5.78 | 8.65 | 0.66 |
| RhythmFormer [23] / PR'2025 | 4.83 | 8.05 | 0.74 | 1.70 | 3.43 | 0.83 | 5.40 | 7.93 | 0.71 |
| PhysDiff [24] / AAAI'2025 | 4.34 | 8.12 | 0.74 | 1.62 | 3.35 | 0.85 | 5.46 | 7.96 | 0.72 |
| PHASE-Net [25] / CVPR'2026 | 4.27 | 7.96 | 0.75 | 1.53 | 3.22 | 0.86 | 5.39 | 7.71 | 0.72 |
| PhysLLM [16] / ICLR'2026 | 4.51 | 8.37 | 0.73 | 1.69 | 3.49 | 0.85 | 5.56 | 8.15 | 0.71 |
| PhysVR (Ours) | 3.92 | 7.23 | 0.77 | 1.34 | 3.07 | 0.87 | 5.14 | 7.21 | 0.74 |
ground-truth HR frequency. In contrast, PhysLLM, PHASE-Net, and RhythmFormer exhibit larger temporal deviations and spectral shifts. Fig. 5 further compares HR estimates on NIRP-DRV, where PhysVR shows a tighter error distribution around zero, with predictions more concentrated around the identity line. These observations are consistent with the quantitative results in Table I and further support the effectiveness of PhysVR under challenging recording conditions.
E. Cross-dataset Evaluation
Table II summarizes the cross-dataset results between NIRP and VIPL-HR. PhysVR achieves the best overall performance across all three transfer settings. When trained on NIRP and evaluated on VIPL-HR, PhysVR obtains an MAE of 3.92 bpm, an RMSE of 7.23 bpm, and a correlation coefficient of 0.77. Compared with the best competing value for each metric, the MAE and RMSE are reduced by 8.2% and 8.7%, respectively, while the correlation coefficient increases from 0.75 to 0.77. When trained on VIPL-HR and evaluated on NIRP-IND, PhysVR achieves an MAE of 1.34 bpm, an RMSE of 3.07 bpm, and a correlation coefficient of 0.87. Compared with PHASE-Net, the MAE and RMSE are reduced by 12.4% and 4.7%, respectively. The improvement remains evident on challenging NIRP-DRV dataset, where PhysVR achieves an MAE of 5.14 bpm, an RMSE of 7.21 bpm, and a correlation coefficient of 0.74, compared with 5.39 bpm, 7.71 bpm, and 0.72 for PHASE-Net. These results show that PhysVR maintains high HR estimation performance across datasets.
Together with the intra-dataset results, the cross-dataset evaluation further demonstrates the robustness of PhysVR across different recording conditions and data distributions. The consistent generalization performance also supports the effectiveness of interference-aware temporal feature refinement. Fig. 6 further compares HR estimation accuracy and computational complexity on VIPL-HR. PhysVR achieves the lowest RMSE among the compared methods. Although PhysVR employs a frozen 2B-parameter VLM, only eight uniformly sampled frames from each clip are processed by the VLM, and its forward computation is included in the reported MACs. This restricted VLM processing limits the additional

Fig. 5: Comparison of HR estimation results on NIRP-DRV. The top row presents the difference between the predicted and ground-truth HR values, while the bottom row shows the corresponding scatter plots of predicted HR against ground-truth HR. The diagonal line represents perfect agreement. From left to right, the columns correspond to PhysVR, PhysLLM, PHASE-Net, and RhythmFormer.

Fig. 6: Comparison of HR estimation accuracy and computational complexity on VIPL-HR. The horizontal axis denotes RMSE, the vertical axis denotes the number of trainable parameters, and the bubble size represents MACs. For PhysVR, the MACs include the forward computation of the frozen VLM on eight uniformly sampled frames from each clip.
computational overhead while retaining the performance gains brought by interference-aware temporal feature refinement.
F. Ablation Studies
Temporal Response of the Interference-Aware Context: We investigate whether the interference-aware temporal context exhibits stronger responses at temporal positions with larger coarse-prediction errors. The local prediction error is computed from the normalized deviation between the coarse prediction and the ground-truth signal, while the context response is quantified by the normalized magnitude of C at each temporal position. As shown in Fig. 7(a), the two sequences exhibit clear temporal correspondence, with a Spearman correlation of 0.674. We further divide the test clips into three equal-sized groups according to their coarse-prediction RMSE.

Fig. 7: Temporal response of the interference-aware context on BUAA-MIHR. (a) Temporal correspondence between local coarse-prediction error and context response, with shaded high-response regions. (b) Average context response for clips with low, medium, and high coarse-prediction errors. Error bars indicate 95% confidence intervals.
Fig. 7(b) shows that the average context response increases from 0.627 in the low-error group to 0.695 in the high-error group. These results indicate that the constructed temporal context responds more strongly when the coarse prediction is less reliable, supporting its role in guiding subsequent feature refinement.
Analysis of Visual Evidence and Interference-Specific Experts: Fig. 8 analyzes the responses of the visual interference evidence and the four interference-specific experts on VIPL-HR. As shown in Fig. 8(a), the percentile rank of the visual-evidence magnitude is lowest under the stable condition at 34.6% and increases under interference conditions, reaching 80.8% under large motion. This result indicates that the VLM-derived visual evidence responds more strongly when visual interference is present. Fig. 8(b) further compares the normalized gated correction contributions of the four experts. The illumination expert shows the largest contribution under dark and bright conditions, accounting for 58.0% and 61.0%, respectively, while the motion expert contributes most strongly under large motion at 47.0%. Under talking, the contributions are more distributed, with the ROI-instability, motion, and blur experts contributing 35.0%, 31.0%, and 20.0%. These results demonstrate condition-dependent responses of the interference-specific experts to different interference.
Effectiveness of Temporal Feature Refinement: To examine whether learned temporal features benefit from further refinement after backbone feature learning, Fig. 9 compares the coarse and final predictions of PhysVR on BUAA-MIHR. As shown in Fig. 9(a), the final HR estimates are closer to the identity line than the coarse estimates. Fig. 9(b) presents a representative example in the temporal and frequency domains. Within the enlarged interval, the local RMSE decreases from 0.58 to 0.46, while the dominant spectral peak shifts from 92.3 to 59.4 bpm, approaching the ground-truth HR of 62.1 bpm. These results show that further temporal feature refinement after backbone feature learning improves rPPG estimation.
Ablation of Physiological and Visual Evidence: Table III evaluates the contributions of the physiological reliability evidence R and visual interference evidence to temporal feature refinement. The refinement architecture is kept unchanged, with only the corresponding evidence input disabled. The coarse prediction obtains an MAE of 3.79 bpm and an

Fig. 8: Analysis of visual evidence and interference-specific expert contributions on VIPL-HR. (a) Direct prediction estimates rPPG from learned temporal features without further refinement. (b) PhysVR combines physiological reliability evidence with VLM-derived visual interference evidence to guide temporal feature refinement before final estimation. (c) An example showing that learned temporal features may remain affected by interference under challenging visual conditions, while further refinement improves the final rPPG prediction.

(a)
(b)
Fig. 9: Effect of temporal feature refinement on BUAA-MIHR. (a) Comparison of coarse and final HR estimates. Gray markers denote unchanged estimates. (b) Temporal and spectral comparison of the ground-truth, coarse, and final rPPG signals for a representative sample. The panels show the complete sequence, an enlarged interval, and the normalized power spectra from top to bottom.
RMSE of 6.83 bpm. Applying temporal feature refinement without either evidence source slightly reduces the MAE and RMSE from 3.79 and 6.83 bpm to 3.67 and 6.72 bpm, respectively, indicating that refinement alone provides a modest improvement over the coarse prediction. Introducing physiological evidence reduces the MAE and RMSE to 3.26 and 6.31 bpm, while visual evidence achieves 3.15 and 6.27 bpm, respectively. Combining both evidence sources yields the best performance, with an MAE of 2.56 bpm and an RMSE of 5.85 bpm. These results show that both evidence sources contribute to temporal feature refinement, with their combination providing the largest performance improvement.
Ablation of the Context-Guided Refinement Module: Table IV evaluates the contribution of each component in the context-guided refinement module. Removing the entire refinement module increases the MAE and RMSE from 3.59/5.68 bpm to 4.82/6.87 bpm, demonstrating the necessity of refining learned temporal features before final estimation. Among the component-level variants, removing the shared correction unit causes the largest performance degradation, highlighting the importance of general temporal correction before interference-specific refinement. Removing any of the four interference-specific experts also degrades performance, with MAE ranging from 4.29 to 4.41 bpm and RMSE from 6.27 to 6.39 bpm, indicating that each expert provides complementary refinement capability. Finally, disabling adaptive routing increases the MAE and RMSE to 4.16 and 6.08 bpm, respectively, demonstrating the benefit of adaptive expert selection. Overall, the full model achieves the best performance, supporting the effectiveness of the complete context-guided refinement design.
TABLE III: Ablation of physiological and visual evidence for temporal feature refinement on NIRP-DRV.
| Configuration | Refinement | R | MAE ↓ | RMSE ↓ | |
|---|---|---|---|---|---|
| Coarse prediction | ✕ | ✕ | ✕ | 3.79 | 6.83 |
| Feature-only refinement | ✓ | ✕ | ✕ | 3.67 | 6.72 |
| + Physiological evidence | ✓ | ✓ | ✕ | 3.26 | 6.31 |
| + Visual evidence | ✓ | ✕ | ✓ | 3.15 | 6.27 |
| Full model | ✓ | ✓ | ✓ | 2.56 | 5.85 |
TABLE IV: Ablation of the context-guided refinement module in PhysVR on VIPL-HR.
| Configuration | MAE ↓ | RMSE ↓ |
|---|---|---|
| No feature refinement | 4.82 | 6.87 |
| w/o Shared correction unit | 4.75 | 6.78 |
| w/o Illumination expert | 4.37 | 6.35 |
| w/o Motion expert | 4.29 | 6.27 |
| w/o Blur expert | 4.35 | 6.32 |
| w/o ROI-instability expert | 4.41 | 6.39 |
| w/o Adaptive routing | 4.16 | 6.08 |
| Full model | 3.59 | 5.68 |
Interference-Specific Expert Specialization: Table V further investigates whether the four experts exhibit specialization toward different types of interference. The illumination expert shows the strongest contribution under dark and bright conditions, as removing it results in the largest performance degradation in both cases. Under large motion, the motion expert becomes the most influential, while removing the blur expert also causes a clear performance drop. For talking sequences, the ROI-instability expert plays the most prominent role. These results show that the four experts contribute differently under different interference conditions, supporting their interference-specific design.
Effect of Visual Encoder, Prompt Design, and VLM Backbone: Table VI evaluates the effects of visual encoders, prompt designs, and VLM backbones on VIPL-HR. Compared with frozen visual encoders such as DINOv3 and PE, the VLM-based evidence branch achieves better performance, suggesting that language-guided visual representations provide more effective interference-related guidance for temporal feature refinement. With Qwen2-VL-2B fixed, replacing the generic prompt with the interference-oriented prompt reduces the MAE from 3.83 to 3.59 bpm and the RMSE from 5.92 to
TABLE V: Condition-wise ablation of interference-specific experts on VIPL-HR.
| Removed expert | Dark | Bright | Talking | Motion |
|---|---|---|---|---|
| Illumination | 5.02/7.22 | 4.88/7.05 | 4.28/6.42 | 4.76/7.08 |
| Motion | 4.15/6.34 | 3.82/6.03 | 4.72/6.86 | 5.63/8.04 |
| Blur | 4.17/6.37 | 3.85/6.06 | 4.49/6.68 | 5.24/7.64 |
| ROI-instability | 4.20/6.39 | 3.88/6.10 | 5.08/7.28 | 4.97/7.26 |
| Full model | 3.92/6.05 | 3.61/5.77 | 4.08/6.16 | 4.54/6.83 |
TABLE VI: Comparison of visual encoders, prompt designs, and frozen VLM backbones on the VIPL-HR dataset.
| Encoder | Prompt | MAE ↓ | RMSE ↓ |
|---|---|---|---|
| DINOv3 [46] | ✕ | 4.49 | 6.65 |
| PE [47] | ✕ | 4.27 | 6.48 |
| Qwen2-VL-2B [33] | Generic | 3.83 | 5.92 |
| Qwen2-VL-2B [33] | Interference-oriented | 3.59 | 5.68 |
| InternVL2.5-2B [48] | Interference-oriented | 3.69 | 5.85 |
| SmolVLM2-2.2B [49] | Interference-oriented | 3.51 | 5.63 |
| Qwen2-VL-7B [33] | Interference-oriented | 3.47 | 5.61 |
5.68 bpm, showing that explicitly directing the VLM toward interference-related factors provides more useful visual evidence. We further compare Qwen2-VL-2B with InternVL2.5-2B, SmolVLM2-2.2B, and Qwen2-VL-7B using the same prompt. Qwen2-VL-2B outperforms InternVL2.5-2B, while SmolVLM2-2.2B further reduces the MAE and RMSE to 3.51 and 5.63 bpm, respectively. Qwen2-VL-7B achieves the best performance with an MAE of 3.47 bpm and an RMSE of 5.61 bpm, while the gain over smaller backbones remains marginal despite the increased model size.
V. CONCLUSION
In this work, we presented PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for robust rPPG estimation. PhysVR combines time-resolved physiological reliability evidence with clip-level visual interference evidence to guide the refinement of learned temporal features, enabling further interference suppression before final rPPG estimation. Extensive experiments on five public benchmarks demonstrate consistent improvements under both intra-dataset and cross-dataset settings, while ablation studies further verify the effectiveness of the proposed refinement design. Although the frozen VLM introduces additional computational overhead, future work will investigate knowledge distillation and more compact visual interference perception models to further improve efficiency.
ACKNOWLEDGMENTS
This work was supported by the key project of Jiangsu Provincial Natural Science Fund under Grant No. BK20253028 and the National Nature Science Fund of China under Grant Nos. 62176124, U24A20330 and 62361166670.
REFERENCES
[1] D. McDuff, “Camera measurement of physiological vital signs,” ACM Computing Surveys, vol. 55, no. 9, pp. 1–40, 2023.
[2] X. Yao, R. Song, J. Cheng, C. Li, and X. Chen, “Hrvfusion: Video-based long-term heart rate variability measurement with conditional diffusion models,” IEEE Transactions on Multimedia, 2026.
[3] Z. Li, H. Shao, L. Luo, J. Yang et al., “Physflow: Frequency decoupled with dual-field rectified flow for remote photoplethysmography,” arXiv preprint arXiv:2606.23226, 2026.
[4] G. Pei, J. Ning, C. Niu, S. Yao, M. Hu, and G. Zhai, “Video respiratory rate measurement in walking scenarios using multi-strategy adaptive denoising,” IEEE Transactions on Circuits and Systems for Video Technology, 2026.
[5] C. Á. Casado, M. L. Cañellas, and M. B. López, “Depression recognition using remote photoplethysmography from facial videos,” IEEE Transactions on Affective Computing, vol. 14, no. 4, pp. 3305–3316, 2023.
[6] X. Liu, Y. Wang, S. Xie, X. Zhang, Z. Ma, D. McDuff, and S. Patel, "Mobilephys: Personalized mobile camera-based contactless physiological sensing," Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, vol. 6, no. 1, pp. 1–23, 2022.
[7] Q. Liang, Y. Chen, and Y. Hu, “Continual learning for remote physiological measurement: Minimize forgetting and simplify inference,” in European conference on computer vision. Springer, 2024, pp. 126–144.
[8] W. Chen and D. McDuff, “Deepphys: Video-based physiological measurement using convolutional attention networks,” in Proceedings of the european conference on computer vision (ECCV), 2018, pp. 349–365.
[9] Z. Yu, Y. Shen, J. Shi, H. Zhao, P. H. Torr, and G. Zhao, “Physformer: Facial video-based physiological measurement with temporal difference transformer,” in Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2022, pp. 4186–4196.
[10] B. Zou, Z. Guo, X. Hu, and H. Ma, “Rhythmmamba: Fast, lightweight, and accurate remote physiological measurement,” in Proceedings of the AAAI Conference on Artificial Intelligence, vol. 39, no. 10, 2025, pp. 11077–11085.
[11] W. Wang, S. Stuijk, and G. De Haan, “A novel algorithm for remote photoplethysmography: Spatial subspace rotation,” IEEE transactions on biomedical engineering, vol. 63, no. 9, pp. 1974–1984, 2015.
[12] R. Song, H. Chen, J. Cheng, C. Li, Y. Liu, and X. Chen, “Pulsegan: Learning to generate realistic pulse waveforms in remote photoplethysmography,” IEEE Journal of Biomedical and Health Informatics, vol. 25, no. 5, pp. 1373–1384, 2021.
[13] X. Liu, Y. Zhang, Z. Yu, H. Lu, H. Yue, and J. Yang, “rppg-mae: Self-supervised pretraining with masked autoencoders for remote physiological measurements,” IEEE Transactions on Multimedia, vol. 26, pp. 7278–7293, 2024.
[14] X. Zhang, W. Sun, H. Lu, Y. Chen, Y. Ge, X. Huang, J. Yuan, and Y. Chen, “Self-similarity prior distillation for unsupervised remote physiological measurement,” IEEE Transactions on Multimedia, vol. 26, pp. 10290–10305, 2024.
[15] Z. Yue, M. Shi, H. Wang, S. Ding, Q. Chen, and S. Yang, “Bootstrapping vision-language models for frequency-centric self-supervised remote physiological measurement,” International Journal of Computer Vision, vol. 133, no. 7, pp. 4112–4133, 2025.
[16] Y. Xie, M. Dai, J.-P. Zhou, Y. Sun, T. Tan, W. Xie, L. Shen, Z. YU et al., “Physllm: Harnessing large language models for cross-modal remote physiological sensing,” in International Conference on Learning Representations, vol. 2026, 2026, pp. 93760–93779.
[17] T. Dai, M. Chang, Y. Chen, and Y. Hu, “rPPG-VQA: A video quality assessment framework for unsupervised rPPG training,” in Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), June 2026, pp. 1365–1375.
[18] G. De Haan and V. Jeanne, “Robust pulse rate from chrominance-based rppg,” IEEE transactions on biomedical engineering, vol. 60, no. 10, pp. 2878–2886, 2013.
[19] W. Wang, A. C. Den Brinker, S. Stuijk, and G. De Haan, “Algorithmic principles of remote ppg,” IEEE Transactions on Biomedical Engineering, vol. 64, no. 7, pp. 1479–1491, 2016.
[20] Z. Yu, X. Li, and G. Zhao, “Remote photoplethysmograph signal measurement from facial videos using spatio-temporal networks,” arXiv preprint arXiv:1905.02419, 2019.
[21] X. Liu, J. Fromm, S. Patel, and D. McDuff, “Multi-task temporal shift attention networks for on-device contactless vitals measurement,” Advances in Neural Information Processing Systems, vol. 33, pp. 19400–19411, 2020.
[22] X. Liu, B. Hill, Z. Jiang, S. Patel, and D. McDuff, “Efficientphys: Enabling simple, fast and accurate camera-based cardiac measurement,” in Proceedings of the IEEE/CVF winter conference on applications of computer vision, 2023, pp. 5008–5017.
[23] B. Zou, Z. Guo, J. Chen, J. Zhuo, W. Huang, and H. Ma, “Rhythmformer: Extracting patterned rppg signals based on periodic sparse attention,” Pattern Recognition, vol. 164, p. 111511, 2025.
[24] W. Qian, G. Su, D. Guo, J. Zhou, X. Li, B. Hu, S. Tang, and M. Wang, "Physdiff: physiology-based dynamicity disentangled diffusion model for remote physiological measurement," in Proceedings of the AAAI Conference on Artificial Intelligence, vol. 39, no. 6, 2025, pp. 6568–6576.
[25] B. Zhao, D. Guo, J. Cao, Y. Xu, B. Zou, T. Tan, Y. Sun, and Z. Yu, "Phase-net: Physics-grounded harmonic attention system for efficient remote photoplethysmography measurement," in Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2026, pp. 21198–21207.
[26] S.-Q. Liu and P. C. Yuen, “Robust remote photoplethysmography estimation with environmental noise disentanglement,” IEEE Transactions on Image Processing, vol. 33, pp. 27–41, 2023.
[27] H. Shao, L. Luo, J. Qian, M. Yan, S. Chen, and J. Yang, “Remote photoplethysmography in real-world and extreme lighting scenarios,” in Proceedings of the Computer Vision and Pattern Recognition Conference, 2025, pp. 10858–10867.
[28] B. Zhao, J. Cao, D. Guo, D. Huang, W. Wang, T. Tan, Y. Sun, and Z. Yu, “Flow: Optimal transport-driven feature warping for generalized remote physiological measurement,” in Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2026, pp. 28481–28491.
[29] A. Radford, J. W. Kim, C. Hallacy, A. Ramesh, G. Goh, S. Agarwal, G. Sastry, A. Askell, P. Mishkin, J. Clark et al., “Learning transferable visual models from natural language supervision,” in International conference on machine learning. PmLR, 2021, pp. 8748–8763.
[30] J. Li, D. Li, C. Xiong, and S. Hoi, “Blip: Bootstrapping language-image pre-training for unified vision-language understanding and generation,” in International conference on machine learning. PMLR, 2022, pp. 12888–12900.
[31] J.-B. Alayrac, J. Donahue, P. Luc, A. Miech, I. Barr, Y. Hasson, K. Lenc, A. Mensch, K. Millican, M. Reynolds et al., “Flamingo: a visual language model for few-shot learning,” Advances in neural information processing systems, vol. 35, pp. 23716–23736, 2022.
[32] H. Liu, C. Li, Y. Li, and Y. J. Lee, “Improved baselines with visual instruction tuning,” in Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2024, pp. 26296–26306.
[33] P. Wang, S. Bai, S. Tan, S. Wang, Z. Fan, J. Bai, K. Chen, X. Liu, J. Wang, W. Ge et al., “Qwen2-vl: Enhancing vision-language model’s perception of the world at any resolution,” arXiv preprint arXiv:2409.12191, 2024.
[34] L. Xi, W. Chen, C. Zhao, X. Wu, and J. Wang, “Image enhancement for remote photoplethysmography in a low-light environment,” in 2020 15th IEEE International Conference on Automatic Face and Gesture Recognition (FG 2020). IEEE, 2020, pp. 1–7.
[35] X. Niu, H. Han, S. Shan, and X. Chen, “Vipl-hr: A multi-modal database for pulse estimation from less-constrained face video,” in Asian conference on computer vision. Springer, 2018, pp. 562–576.
[36] X. Niu, S. Shan, H. Han, and X. Chen, “Rhythmnet: End-to-end heart rate estimation from face via spatial-temporal representation,” IEEE Transactions on Image Processing, vol. 29, pp. 2409–2423, 2019.
[37] E. M. Nowara, T. K. Marks, H. Mansour, and A. Veeraraghavan, "Near-infrared imaging photoplethysmography during driving," IEEE transactions on intelligent transportation systems, vol. 23, no. 4, pp. 3589–3600, 2020.
[38] E. Magdalena Nowara, T. K. Marks, H. Mansour, and A. Veeraraghavan, "Sparseppg: Towards driver monitoring using camera-based vital signs estimation in near-infrared," in Proceedings of the IEEE conference on computer vision and pattern recognition workshops, 2018, pp. 1272–1281.
[39] J. Tang, K. Chen, Y. Wang, Y. Shi, S. Patel, D. McDuff, and X. Liu, "Mmpd: Multi-domain mobile video physiology dataset," in 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE, 2023, pp. 1–5.
[40] H. Lu, H. Han, and S. K. Zhou, “Dual-gan: Joint bvp and noise modeling for remote physiological measurement,” in Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2021, pp. 12404–12413.
[41] C. S. Pilz, S. Zaunseder, J. Krajewski, and V. Blazek, “Local group invariance for heart rate estimation from face videos in the wild,” in
Proceedings of the IEEE conference on computer vision and pattern recognition workshops, 2018, pp. 1254–1262.
[42] J. Li, Z. Yu, and J. Shi, “Learning motion-robust remote photoplethysmography through arbitrary resolution videos,” in Proceedings of the AAAI Conference on Artificial Intelligence, vol. 37, no. 1, 2023, pp. 1334–1342.
[43] H. Lu, Z. Yu, X. Niu, and Y.-C. Chen, “Neuron structure modeling for generalizable remote physiological measurement,” in Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2023, pp. 18589–18599.
[44] Z. Yu, Y. Shen, J. Shi, H. Zhao, Y. Cui, J. Zhang, P. Torr, and G. Zhao, “Physformer++: Facial video-based physiological measurement with slowfast temporal difference transformer,” International Journal of Computer Vision, vol. 131, no. 6, pp. 1307–1330, 2023.
[45] X. Liu, G. Narayanswamy, A. Paruchuri, X. Zhang, J. Tang, Y. Zhang, R. Sengupta, S. Patel, Y. Wang, and D. McDuff, “rppg-toolbox: Deep remote ppg toolbox,” Advances in Neural Information Processing Systems, vol. 36, pp. 68485–68510, 2023.
[46] O. Siméoni, H. V. Vo, M. Seitzer, F. Baldassarre, M. Oquab, C. Jose, V. Khalidov, M. Szafraniec, S. Yi, M. Ramamonjisoa et al., “Dinov3,” arXiv preprint arXiv:2508.10104, 2025.
[47] D. Bolya, P.-Y. Huang, P. Sun, J. H. Cho, A. Madotto, C. Wei, T. Ma, J. Zhi, J. Rajasegaran, H. Bangalath et al., “Perception encoder: The best visual embeddings are not at the output of the network,” Advances in Neural Information Processing Systems, vol. 38, pp. 60884–60937, 2026.
[48] Z. Chen, W. Wang, Y. Cao, Y. Liu, Z. Gao, E. Cui, J. Zhu, S. Ye, H. Tian, Z. Liu et al., “Expanding performance boundaries of open-source multimodal models with model, data, and test-time scaling,” arXiv preprint arXiv:2412.05271, 2024.
[49] A. Marafioti, O. Zohar, M. Farré, M. Noyan, E. Bakouch, P. Cuenca, C. Zakka, L. B. Allal, A. Lozhkov, N. Tazi et al., “Smolvlm: Redefining small and efficient multimodal models,” arXiv preprint arXiv:2504.05299, 2025.