arXiv:2608.29928cs.CVAug 2026Cited by 1 paper on PaperVantage

Manuscript Offprint

arXiv:2608.29928

Biomechanical 3D Body: Self-Supervised Distillation of Biomechanical Pose from a 3D Body Foundation Model

R. James Cotton, J. D. Peiffer, Lucinda Williamson, John Leske, Georgios Pavlakos

R. James Cotton 1,2^{1,2}, J.D. Peiffer 1,3^{1,3}, Lucinda Williamson 4^{4}, John Leske 1,3^{1,3}, Georgios Pavlakos 5^{5}

1^{1}Shirley Ryan AbilityLab, Chicago, IL, USA

2^{2}Physical Medicine & Rehabilitation, Northwestern University, Chicago, IL, USA

3^{3}Biomedical Engineering, Northwestern University, Evanston, IL, USA

4^{4}Biomedical Engineering, University of Illinois Chicago, Chicago, IL, USA

5^{5}Computer Science, University of Texas at Austin, Austin, TX, USA

State-of-the-art monocular body recovery methods predict mesh vertices and angles on the corresponding kinematic tree, but their outputs lack biomechanically defined joint angles that downstream applications like clinical and biomechanical analyses require. We extend an existing foundation model, SAM-3D-Body, with an additional biomechanical prediction head that, from a single RGB image, regresses the joint angles and scales of a biomechanical model. Training this model presents a challenge, as there are limited datasets of paired images and biomechanical fits. To overcome this, we supervise biomechanical outputs with in-loop optimized targets from a Levenberg-Marquardt solver performing inverse kinematics fits against markers from the mesh predictions. This allows distilling the biomechanical head from the mesh head, even from unlabeled images. To make this work with GPU-optimized biomechanical models in MuJoCo, the entire model was implemented in JAX using Equinox. We trained this distilled output head on the publicly released SAM-3D-Body dataset. We then validated this model on biomechanical fits to two publicly available marker-based datasets, MoVi and BioCV, as well as movements from a clinical cohort captured with multiview markerless motion capture. The resulting model outperforms existing models for direct regression of biomechanics from images while only slightly underperforming the state-of-the-art monocular biomechanics method that performs more costly inference-time optimization of entire trajectories.

Date: August 2026

Correspondence: rcotton@sralab.org

Intelligent

Sensing and

Rehabilitation

1 Introduction

Movement directly reflects neurological and musculoskeletal health, yet it is rarely measured in routine clinical care. Multiview markerless motion capture (MMMC) has matured to the point where, on well-observed movements, it agrees closely with marker-based optical systems for gait and upper-limb analysis (Kanko et al., 2021; Unger et al., 2025; Cotton, 2025; Firouzabadi et al., 2024). This progress rides on the rapid evolution of monocular human pose estimation, which now culminates in large foundation models that accurately estimate 2D and 3D keypoints (Sárándi et al., 2023; Khirodkar et al., 2024, 2026). These keypoint trajectories can then be used to recover biomechanically defined joint angles following the ISB standards for the lower and upper limb (Wu et al., 2002, 2005), either by inverse kinematics (IK) on triangulated virtual keypoint trajectories (Uhlrich et al., 2023) or by directly optimizing biomechanical fits.

to minimize reprojection error (Cotton, 2025; Donahue et al., 2026).

In parallel, there has been substantial progress in estimating high-quality 3D mesh representations of humans from monocular images (Kanazawa et al., 2018; Shin et al., 2024; Yang et al., 2026). SAM-3D-Body is a particularly powerful recent state-of-the-art method that predicts the parameters of the Momentum Human Rig (MHR) (Ferguson et al., 2025), a model that decouples a possible skeleton from a shape-dependent surface. However, the kinematic trees of MHR and other widely used mesh models such as SMPL do not directly respect the anatomical joint definitions or rotational degrees of freedom required for clinical and biomechanical analyses (Loper et al., 2015). This mismatch has motivated recent work on models such as SKEL, which incorporates skeletal bones into a surface mesh representation and begins to bridge computer-vision body models with biomechanical analysis (Keller et al., 2022, 2023).

Several recent monocular systems have built on these advances to estimate biomechanical quantities from video. Human Skeleton and Mesh Recovery (HSMR) (Xia et al., 2025), for example, uses the SKEL model but addresses the lack of paired image/SKEL labels by converting SMPL pseudo-ground-truth from existing pose datasets into SKEL parameters. It then refines these labels during training with SKELify, a SMPLify-style iterative optimizer that fits SKEL parameters to 2D keypoints. HSMR is optimized for keypoint position accuracy, which is an important computer-vision metric but does not reliably predict joint-angle accuracy (Wang et al., 2026). Recently, OpenCap released a monocular version of its software (Gilon et al., 2026) that computes IK fits to SMPL estimates from WHAM (Shin et al., 2024) with additional physics-constrained refinement. Finally, our recent Portable Biomechanics Laboratory (PBL) (Peiffer et al., 2026), uses 2D and 3D keypoint locations from an existing foundation model (Sárándi et al., 2023) and optimizes a biomechanical fit to these data by minimizing reprojection error and a 3D keypoint loss while enforcing a single skeleton scaling across multiple trials. Although PBL reports state-of-the-art accuracy and was validated against both marker-based and MMMC in a large, clinically representative population, its optimization-based fitting process remains relatively slow.

This motivated us to investigate whether we could adapt a state-of-the-art vision model for estimating mesh representations from video, SAM-3D-Body, to output biomechanical estimates in a feed-forward manner while achieving accuracy comparable to optimization-based approaches. Two obstacles stand between a mesh foundation model and feed-forward biomechanics. First, there is no large paired dataset of images annotated with biomechanical ground truth, so a regressor cannot simply be trained against joint-angle labels. We recently showed that accurate biomechanical estimates can be obtained from SAM-3D-Body MHR estimates using IK fits to individual MHR poses (Cotton et al., 2026), similarly to SKELify. Second, popular biomechanical simulators such as OpenSim (Delp et al., 2007) and Nimblephysics/AddBiomechanics (Werling et al., 2023) are not built to integrate into model training. MuJoCo (Todorov et al., 2012), through its JAX accelerated MJX backend, makes forward kinematics (FK) differentiable and highly performant, but using it would require linking the Torch-based SAM-3D-Body model to a JAX-based biomechanical model.

Our approach addresses both obstacles at once. We port SAM-3D-Body and MHR to JAX/Equinox (Bradbury et al., 2018; Kidger and Garcia, 2021) so that the frozen foundation model and the differentiable MJX FK live in a single differentiable framework. Onto the frozen backbone and decoder we graft a small trainable biomechanical head that reads the existing decoder tokens and regresses the generalized coordinates (qpos), per-group segment scales, and anatomical marker offsets of a MuJoCo biomechanical model. To address the absence of paired labels, we draw on model-in-the-loop optimization (SPIN) (Kolotouros et al., 2019), which during training optimizes a model's outputs to better align with a more accurate teacher, mirroring the refinement HSMR obtains from 2D keypoints with SKELify. Concretely, a loss function quantifies MHR-to-biomechanics alignment by enforcing pose similarity between site-marker positions (computed via differentiable MuJoCo FK) and MHR-derived markers, requiring no ground-truth biomechanical labels. An inline Levenberg–Marquardt IK solver optimizes this objective in the training loop and provides pseudo-labels for qpos and scale. We show the resulting model, which we term Biomechanical 3D Body or B3D for short, is competitive with SOTA monocular biomechanical methods that utilize extensive optimization.

This paper makes three contributions:

  1. Dual-head foundation model. A small trainable biomechanical head on a frozen SAM-3D-Body backbone adds clinically interpretable, MuJoCo-compatible biomechanical outputs with minimal parameter and compute cost.

  2. Label-free distillation. The head is trained entirely from the frozen MHR head through an expectation-maximization (EM)-fitted marker mapping and differentiable MuJoCo FK, requiring no paired image–biomechanics dataset. While this is trained on a dataset with ground truth MHR pseudo-labels, these labels are not used in training, only the SAM-3D-Body predictions.

  3. Model-optimization-in-the-loop biomechanical training. An inline Levenberg-Marquardt IK solver supplies cold-to-warm pseudo-labels and, by learning to seed it, the head drives the IK past what cold starts reach.

References (69)