Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance. Code here.

1 Introduction

Diagnostic errors remain a significant challenge in radiology, occurring in approximately 3–5% of radiological interpretations [15]. Clinicians rely on FDG PET/CT radiology reports - which consist of a detailed findings section and a brief summarising conclusions section - to guide cancer staging and assess response to treatment. Errors in reports can alter clinical management, which motivates automated methods for quality control [3]. Detecting such errors is challenging because many involve subtle semantic differences, such as distinguishing physiological uptake from malignancy or recognising changes in disease burden, rather than explicit textual contradictions [1, 21].

Recent work has explored Large Language Models (LLMs) for automated radiology report verification, but evaluation has largely been limited to chest X-ray (CXR) datasets [7, 19, 14, 17] and a few on CTs [13, 16]. PET/CT reports present additional challenges due to the need to integrate metabolic and anatomical information and their substantially greater length (typically > 2× that of CXR reports [11, 21]), raising questions about the generalisability of CXR report error detection approaches.

Preprint.

Furthermore, hospitals' privacy and governance requirements often preclude the use of cloud-hosted LLMs, motivating locally deployable solutions. Domain-specific language models (LMs) can be developed around site-specific processes and governance requirements, enabling simpler integration into clinical workflows [17, 4, 2]. These factors raise a fundamental question: are billion-parameter LLMs necessary for PET/CT report quality control, or can compact domain-specific LMs better detect clinically meaningful inconsistencies?

To address this question, we collected a dataset of 30,633 whole body FDG PET/CT oncology reports. To compensate for the lack of radiology reports containing labelled errors, we introduce a synthetic error generator and construct a benchmark comprising 11,500 held-out reports with inserted clinically relevant inconsistencies (e.g. errors in disease severity or location). We pre-train domain-specific BERT models using masked language modelling and findings–conclusion consistency objectives before supervised fine-tuning, and compare performance against SOTA open-source LLMs. Despite containing around 1000× fewer parameters, our domain-specific LMs consistently outperform all evaluated LLM baselines, achieving higher accuracy and substantially lower false-positive rates (FPR). Our contributions are as follows:

  1. We provide the first systematic comparison between state-of-the-art open-source LLMs and domain-specific language models for oncology PET/CT report error checking.

  2. We introduce a controlled synthetic benchmark spanning five clinically motivated PET/CT reporting errors and evaluate robustness to synthetic lexical artefacts, unseen perturbation terminology, prompt design, and model confidence.

  3. We show that compact models pre-trained on in-domain PET/CT reports substantially outperform much larger generic LLMs, with a 15M-parameter BERT achieving 94.4% balanced accuracy and a 5.8% false-positive rate.

References (15)

  • Alotaibi et al
  • doi: 10.48550/arXiv.2506.02153 (opens arXiv in a new tab)
  • A Benchmark for Medical Error Detection and Correction in Clinical Notes
  • Rapid Chest X-ray Report Evaluation by Predicting Multi-category Error Counts
  • efficient finetuning of quantized llms
  • Pre-training of Deep Bidirectional Transformers for Language Understanding
  • Implications for Reporting Accuracy
  • LoRA: Low-Rank Adaptation of Large Language Models
  • Sci Data, 6, 2019
  • Radiology, 314, 2025
  • Framework Development and Validation
  • Mayes et al
  • A Radiology Report Error Detector based on Deep Learning Framework
  • Radiology, 325(2), 2025
  • A large-scale empirical analysis