arXiv:2608.30298physics.opticsAug 2026

Manuscript Offprint

arXiv:2608.30298

Sensitivity Comparison of Microwave-Frequency and Optical Fibre Interferometry Based on State-of-the-Art Components

Georgios Aias Karydis, Marco Fasano, Paola Parolari, Pierpaolo Boffi, Charis Mesaritakis, Adonis Bogris

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

We compare the sensitivity of fibre interferometers to vibrations using microwave oscillators and state-of-the-art lasers over distances up to 70 km. High spectral purity lasers outperform only above 10 Hz, highlighting microwave advantages at low frequencies and the potential of hybrid microwave-optical interferometry systems. ©2026 The Author(s)

Introduction

Fibre optics sensing techniques that are incorporated in already installed cable networks have gained significant traction the last decade due to their multiple potential applications spanning from optical network surveillance, smart cities applications to geophysical and environmental monitoring [1-3]. The dominant way to implement fibre sensing is with the use of a stable laser oscillator either in reflectometry or interferometry configurations. The former approach has given rise to a large number of distributed acoustic sensing (DAS) implementations, such coherent optical time domain reflectometry (C-OTDR), phase-OTDR and optical frequency domain reflectometry (OFDR) [4,5]. The use of interferometry has been promoted in submarine cables for interrogating very long links mostly targeting geophysical monitoring in the deep ocean [5,6]. In all implementations, the sensitivity of the interrogator is determined by the capability of the technique in acquiring phase changes over the phase noise of the laser source. This is why fibre lasers with sub-kHz linewidth are employed in all commercially available DAS systems, whilst in long-haul implementations, even more sophisticated lasers, with sub-Hz linewidth, are preferred to expand the coherence length of the source to thousands of km [6].

Recently, the use of microwave sources in fibre interferometry and DAS experiments has been proposed [7-9]. The sensitivity of phase acquisition in the microwave domain is lower compared to optical phase measurements as phase changes are proportional to the interrogation frequency. Despite the much lower phase signal offered by the interrogation in the microwave domain, the use of microwave sources has critical advantages. On one hand, the low phase noise of state-of-the-art microwave oscillators guarantees better noise performance at low frequencies especially if geophysical monitoring is targeted [7,8]. On the other hand, DAS systems employing microwave carriers have a much higher saturation limit in large strain rate variations compared to typical DAS approaches which make them an interesting candidate for early warning systems [9]. Despite the parallel implementations of DAS and interferometry systems based on laser and microwave carriers in the literature, a systematic work comparing their sensitivity is missing with the exception of very recent theoretical paper focused on submarine cables [10].

In this work, we implement microwave frequency fibre interferometers (MFFI) and optical

(a)

(b)

(c)

Figure

Fig. 1: (a) MFFI setup, (b) fibers used in the experiment, (c) OFI setup. MZM: Mach-Zehnder modulator, MO: Microwave oscillator, FS: Fibre Stretcher, DFB: Distributed Feedback Laser, PD: Photodiode, NKT: NKT Koheras Laser E15, AOM: Acousto-optic modulator, PC: Polarization Controller, OSC: Oscilloscope.

interferometers (OFI) with path lengths ranging from 300 m to 70 km, using state of the art commercially available oscillators, namely 10-GHz microwave generators and a fibre laser with 100-Hz linewidth. We compare MFFI and OFI in terms of phase noise and sensitivity to well controlled stimuli generated by a fibre stretcher. The analysis clearly shows the superiority of OFI at frequencies above > 10 Hz in all studied paths and the trend of MFFI to provide equal or even better sensitivity at frequencies below 5 Hz. These results clearly demonstrate that MFFI and OFI are complementary modalities, and that their integration into a hybrid system enables a highly powerful interrogator with exceptional sensitivity and a broad dynamic range spanning sub-mHz to kHz acoustic sensing.