Manuscript Offprint

arXiv:2608.30846

VFR-Audit: Verdict-Level Reliability for Fairness Audits in Hospital Length-of-Stay Prediction

Md Jannatul Rakib Joy, Viet Vo, Caslon Chua

Md Jannatul Rakib Joy

School of Science, Computing and

Emerging Technologies

Swinburne University of Technology

Hawthorn, Victoria, Australia

103799644@student.swin.edu.au

Viet Vo

School of Science, Computing and

Emerging Technologies

Swinburne University of Technology

Hawthorn, Victoria, Australia

vvo@swin.edu.au

Caslon Chua

School of Science, Computing and

Emerging Technologies

Swinburne University of Technology

Hawthorn, Victoria, Australia

cchua@swin.edu.au

Abstract

Fairness audits in clinical Artificial Intelligence convert continuous fairness metrics into binary pass-or-fail verdicts against operational thresholds, where hospital governance boards, payers, and regulators act on the resulting verdicts. Such audits are repeated over time and across hospital sites, thus the same verdict can flip between pass and fail across audits. Existing uncertainty methods such as Bayesian posteriors, bootstrap confidence intervals, and permutation tests address verdict instability only at the continuous-metric level. Converting metric-level uncertainty into a verdict-stability claim remains a manual step that scales poorly across the (model, metric, attribute) cells an audit covers. Existing uncertainty methods also leave open whether bias-mitigation steps, such as reweighing or per-group threshold shifts, yield a stable passing verdict at the cost of model discrimination measured as AUROC or AUPRC.

To address this verdict-stability gap, we propose VFR-Audit, a framework built around the Verdict Flip Rate (VFR), a scalar bounded between 0 and 0.5 that measures the probability of verdict reversal under stratified bootstrap resampling. VFR-Audit reports VFR alongside three reliability axes, namely within-cohort resampling stability, audit-size sensitivity, and cross-hospital verdict agreement via Fleiss' kappa. The framework was evaluated on 925,128 administrative discharge records from 441 Texas hospitals, against an intersectional adaptation of Kamiran and Calders' reweighing. On the unintervened baseline, the audit detects verdict reversal in 43.5% of cells in the cross-model audit grid. After the canonical intervention, 11 of 28 cells continue to flip. Intersectional reweighing fails the four-fifths rule on this cohort regardless of regularisation strength, while per-cell threshold shifting is the main effective component of the canonical intervention. VFR translates continuous metric uncertainty into a probability of binary-verdict reversal, and a derived-baseline comparison attributes the verdict outcome to specific intervention components, so audit reliability and intervention effects can be reported together rather than as separate claims.

CC BY NC ND

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

CIKM '26, November 7–11, 2026, Rome, Italy

© 2026 Copyright held by the owner/author(s).

ACM ISBN 979-8-4007-2539-5/2026/11

https://doi.org/10.1145/3799682.3840827

CCS Concepts

• Applied computing → Health informatics; • Computing methodologies → Machine learning; • Social and professional topics → Computing / technology policy; • Information systems → Data mining.

References (43)