arXiv:2608.31073cs.CVAug 2026

Manuscript Offprint

arXiv:2608.31073

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

Jiacheng Wang, Ivana Isgum, Ipek Oguz

Jiacheng Wang 1^{1}, Ivana Isgum 2^{2}, and Ipek Oguz 1∗^{1*}

1^{1} Vanderbilt University, Nashville, TN, USA

jiacheng.wang.1, ipek.oguz@vanderbilt.edu

2^{2} Mayo Clinic, Rochester, MN, USA

isgum.ivana@mayo.edu

Abstract. Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

Keywords: Whole-heart segmentation · Label-to-image synthesis · Synthetic data augmentation · Cross-modality learning · Cardiac imaging

1 Introduction

Whole-heart segmentation (WHS) from computed tomography (CT) and magnetic resonance imaging (MRI) requires a model to delineate seven connected structures: left ventricular myocardium (Myo), left atrium (LA), left ventricle (LV), right atrium (RA), right ventricle (RV), ascending aorta (AO), and pulmonary artery (PA). The CARE Whole-Heart track makes the heterogeneity across scanners, protocols, and centers explicit: images differ in contrast, voxel

∗^{*} Corresponding author

J. Wang et al.

Figure

Fig. 1. Representative sources of heterogeneity in CARE-WHS CT and MRI. From left to right: pulmonary artery (PA, yellow) annotation limited to the proximal trunk versus extending into both branches beyond the bifurcation; ascending aorta (AO, pink) annotation limited to the ascending segment versus continuing through the arch; thinner versus thicker myocardium at the Myo-LV boundary; and cardiac-focused CT versus wider thoracoabdominal MRI coverage.

spacing, orientation, and field of view [3,13]. Another source of heterogeneity is variation in the field of view of the scans and in the extent of the manual annotations, which can especially affect the great vessels (AO and PA). The CARE challenge defines the AO target as the segment from the aortic valve to the superior level of the atria, and the PA target as the segment from the pulmonary valve to its bifurcation [3]. Owing to the practical difficulty of consistently delineating distal vessel endpoints, the released CARE labels show some variation: the AO annotation can terminate near the proximal ascending segment or continue through the arch, and the PA annotation can end before or after its bifurcation. Thus, predictions for these structures must be evaluated over standardized lengths to account for this variability. Figure 1 illustrates representative variation in scan coverage, AO and PA annotation extent, and Myo-LV boundary geometry across the released cases.

Most WHS methods address heterogeneity by modifying the segmentation pipeline. Common baselines include 3D U-Net [4], UNETR [7], SwinUNETR [6], and nnU-Net [9]. Recent CARE submissions have further explored transfer learning with intensity transformations [2] and implicit-representation modules [11]. These approaches modify the model or its training procedure, but they do not explicitly expand the cardiac label geometries or annotation extents represented by the supervision. Rather than introducing another segmentation architecture, we investigate whether cross-modality WHS can be improved by changing the images and supervision used during training.

Label-to-image synthesis provides one such intervention while retaining the same segmentation architecture. This strategy has two requirements. First, the synthetic images must span the appearance variation induced by the target acquisitions. We adopt SynthSeg, which samples training images from deformed label maps using class-specific intensity distributions and simulated acquisition effects [1]. Second, the label maps must represent the anatomical variability of the target task. SIAM addresses this requirement through high-resolution, anatomy-specific label transformations rather than only global affine or elastic deformation [10]. BabySeg further combines synthetic contrast variation with information from real scans [8]. Together, these studies motivate using synthesis for appearance variation and designing label operations around the structures that vary in the target task.

CARE-WHS presents two specific difficulties: incomplete context for image synthesis and structure-specific label variability. The seven target classes do not describe surrounding thoracic tissues, so images synthesized from labels alone omit context present in real scans. Meanwhile, label variability differs by structure: myocardial wall thickness changes the Myo-LV boundary, whereas the distal extents of the AO and PA reflect differences in both anatomy and manual labeling practice (Fig. 1). Global deformation changes pose and overall shape, but it does not directly model either the Myo-LV interface or variable great-vessel endpoints. A cardiac adaptation should therefore use synthesis to complement rather than replace real-image supervision, calibrate appearance variation to observed acquisitions, and apply label operations to the structures that vary in this task.

LISynSeg follows these design choices. Real CT and MRI examples are mixed with images synthesized from labels using cohort-calibrated acquisition parameters. Shape variation is introduced at the Myo-LV boundary, and supervision is relaxed in distal vessel regions whose annotated extent varies across cases. Figure 2 contrasts images generated by LISynSeg and a SynthSeg-style baseline from the same CT and MRI label maps. The controlled comparisons use a common segmentation architecture and inference pipeline to isolate the effect of training data construction. Separately, we report the result of our submitted ensemble in the official CARE 2026 validation phase, where it ranked top five on the combined CT and MRI leaderboard at the time of writing.

Our main contributions are as follows:

– We investigate whether cross-modality WHS can be improved by changing the training data and supervision while keeping the segmentation architecture and inference procedure fixed.

– We propose LISynSeg, a real-synthetic training framework that combines cohort-calibrated image synthesis with Myo-LV boundary transformations and partial supervision at variable distal vessel endpoints.

– We show that real-synthetic training improves over real-only and synthetic-only baselines, particularly on the more challenging MRI cases.